Danfoss WP75-RF Installation guide

Category
Thermostats
Type
Installation guide
WP75
-
RF
7 day electronic
programmable hot
water controller
Installation & User Instructions
®
Certification Mark
2
Index
Index
Installation
Product specifi cation 3
Thermostat (WP75-RF) installation 4-5
Sensor (CS1) installation 5-7
Wiring 7
Commissioning 8
User
What is a Cylinder Thermostat? 9
Your programmer 10
How to read the display 10
Preset programmes 11
Resetting the unit 11
Setting the Time and Day 12
Running your programme 12
Before changing the preset programmes 13
Programming the unit (7-day mode) 14
Programming the unit (5/2-day mode) 15
Running your programme 16
BOOST function 17
Hot Water Available function 17-18
Changing clocks forward/back 18
Battery backup 19
Contact details 20
3
Product Specifi cation
Product Specifi cation
Please Note:
This product should only be installed by a qualifi ed
electrician or competent heating installer and
should be in accordance with the current edition of
the IEEE wiring regulations.
Important note RF products: Ensure that there are no large metal objects, such as boiler cases
or other large appliances, in line of sight between the transmitter and receiver as these will
prevent communication between thermostat and receiver.
Thermostat features WP75-RF
Power supply 2 x AA/MN1500/LR alkaline cells
Memory back-up 1 min for battery change
Transmission frequency (RF model) 433.92MHz
Transmitter range (RF model) 30m max
Max. ambient temperature 45°C
Temperature range 35 - 65°C
Dimensions, mm (W x H x D) Unit - 110 x 88 x 28
Remote Sensor - 48 x 48 x 45
Design standard EN60730-2-9 (EN300220 for RF)
Ball hardness test 75°C
Control pollution situation Degree 2
Time accuracy ± 1 min
Temperature accuracy ± 1°C
Installation Instructions
4
Thermostat Installation
Installation
WP75-RF installation
Select a position for the WP75-RF that provides easy access to
the unit (it could be used on a daily basis by the user, so the
display needs to be clearly visible) and bearing in mind that
the maximum distance between the thermostat and sensor is
10 metres.
Prepare the fi xing position to provide access for the sensor
cable through the rear of the wallplate.
If the cable is to be surface fi xed note that it can only enter
the WP75-RF from the bottom through the positions shown
below.
Fix the wallplate so that the control module can be easily
attached or removed. Make the sensor wiring connections as
shown in the wiring diagram on page 7.
Before attaching the control module to the wallplate set the
DIL switch, located in a recess on the rear of the module, to
select whether the WP75-RF will be a 7 day controller or a 5/2
day (weekday/weekend) controller. Move both switches to the
desired position.
A
B
30mm min
Wall or plaster
box mounting
holes
Aperture for
rear entry
Clearance for
screwdriver access
Knockout for bottom
cable entry
Terminals
Outline of entry
5
Attach the control module to the wallplate by placing the
slots in the top of the module over the lugs on the top edge
of the wallplate and hinging down until the slot in the bottom
edge of the module locates over the screw attached to the
wallplate. Tighten the screw.
CS1 Sensor installation
Gas or Oil fi red Boiler Systems
The sensor should be fi tted to the side of the domestic hot
water cylinder, half way up from the bottom.
Select the fi xing position and remove suffi cient insulation to
ensure that the sensor element can make close contact with
the surface of the cylinder wall.
Clean away all traces of insulation and ensure both cylinder
wall and sensor are clean.
Before mounting the sensor, coat the copper foil on the contact
surface of the sensor with the heat conducting paste supplied.
The sensor must be connected to the WP75-RF using double
insulated cable greater than 0.75mm
2
.
For insulation thicker than 25mm
and up to 55mm thick, use the
extra cover supplied as a spacer to
ensure that the sensor is held in
firm contact with the cylinder wall.
1/2 cylinder
height
Sensor Installation
IMPORTANT
1. Ensure cylinder wall is clean
2. Use heat transfer paste
provided
6
Connect the cable to the sensor terminals and replace the
cover. Place the sensor on the cylinder and clamp tightly to
the cylinder using the strap provided.
Cable entry is from behind if fi tted to a single gang fl ush box,
or from above, below or from the left if surface fi xed cable is
used.
Fast Recovery Cylinder Heater Systems
The sensor should be fi tted to the side of the domestic hot
water cylinder just below the top seam.
Select the fi xing position and remove suffi cient insulation to
ensure that the sensor element can make close contact with the
surface of the cylinder wall (see opposite).
Clean away all traces of insulation and ensure both cylinder
wall and sensor are clean.
Before mounting the sensor, coat the copper foil on the
contact surface of the sensor with the heat conducting paste
supplied.
Sensor Installation
For insulation thicker than 25mm
and up to 55mm thick, use the
extra cover supplied as a spacer
to ensure that the sensor is held
in firm contact with the cylinder wall.
IMPORTANT
1. Ensure cylinder wall is clean
2. Use heat transfer paste
provided
7
Thermostat Wiring
Wiring
Receiver
NL1234
L N
L N
Boiler
Pump
2-port zone valve
L
N
Transmitter
A B
WP75-RF
RX1 Receiver
RX1 & RX2
RX3
RX1 & 2 (3055 12/01)
COM
ZONE
2 ON
ZONE
1 ON
ZONE
1 OFF
TERMINAL 1
RX2 ONLY
ELECTRONICS
RX Receiver Wiring
Note 1) For mains voltage operated systems link terminal 2 to mains live supply.
2) Power supply to unit must not be switched by timeswitch
The sensor must be connected to the WP75-RF using double
insulated cable greater than 0.75mm
2
.
Connect the cable to the sensor terminals and replace the
cover. Place the sensor on the cylinder and clamp tightly to
the cylinder using the strap provided.
8
Commissioning
Commissioning
If the thermostat and the receiver have been supplied together
in a combined pack, the units have been paired in the factory
and no commissioning is required (RX1 only).
To tune the RX receiver to the frequency of the thermostat signal,
follow steps 1-5 below.
1. WP75-RF
Press the recessed RESET button, using
a non-metallic object, to reset the unit.
2. Press & hold the recessed LEARN
button for 3 seconds, using a non-
metallic object.
NOTE: Thermostat now transmits
continuously for 5 minutes.
3. RX1
Press and hold buttons PROG and CH1
for 3 seconds until green light fl ashes
once.
4. RX2 (if applicable)
Stat 1 - perform steps 1-3
Stat 2 - wait 5 mins, perform steps 1-2,
then press PROG + CH2 on RX2
RX3 (if applicable)
Stat 1 - repeat step 2-3 for CH1
Stat 2 - wait 5 mins, perform steps 1-2, then press PROG + CH2
on RX3
Stat 3 - wait 5 mins, perform steps 1-2, then press PROG + CH3
on RX3
5. WP75-RF
Press or - the unit will revert to
normal operation.
(1)
(2)
9
What is a cylinder thermostat?
... an explanation for householders.
A cylinder thermostat switches on and off the heat supply from the
boiler to the hot-water cylinder. It works by sensing the temperature
of the water inside the cylinder, switching on the water heating
when the temperature falls below the thermostat setting, and
switching it off once this set temperature has been reached.
Turning a cylinder thermostat to a higher setting will not make the
water heat up any faster. How quickly the water heats up depends
on the design of the heating system, for example, the size of boiler
and the heat exchanger inside the cylinder.
The water heating will not work if a time switch or programmer has
switched it off. And the cylinder thermostat will not always switch the
boiler off, because the boiler sometimes needs to heat the radiators.
Cylinder thermostats are usually fi tted between one quarter and
one third of the way up the cylinder. The cylinder thermostat will
have a temperature scale marked on it, and it should be set at
between 60°C and 65°C, then left to do its job. This temperature is
high enough to kill off harmful bacteria in the water, but raising the
temperature of the stored hot water any higher will result in wasted
energy and increase the risk of scalding.
If you have a boiler control thermostat, it should always be set
to a higher temperature than that of the cylinder thermostat. In
most boilers, a single boiler thermostat controls the temperature
of water sent to both the cylinder and radiators, although in some
there are two separate boiler thermostats.
The text below has been edited and approved by the Plain English
Campaign, who has issued a Crystal Mark to be displayed with it.
What is a cylinder thermostat?
Please note: The WP75-RF is a programmable cylinder thermostat.
10
Your programmer
The WP75-RF is a wireless programmable thermostat, designed to
control the temperature of the water in your hot water cylinder.
Heating water to a temperature which is higher than necessary
is wasteful of energy. The WP75-RF lets you heat your water to a
temperature you require, just at the times you need it. You can
programme up to three ON times and temperatures per day.
It also features a BOOST function, to provide an instant tank of hot
water, as well as a Hot Water Available function, which tells you
how much hot water you have available in your cylinder.
How to read the display
Overview & reading the display
User Instructions
11
Weekdays (Mon-Fri) Weekend (Sat-Sun)
Event Time Temp °C Event Time Temp °C
1 06:30 55.0 1 07:30 55.0
2 08:30 OFF 2 09:30 OFF
3 12:30 45.0 3 11:30 45.0
4 13:30 OFF 4 13:30 OFF
5 16:00 55.0 5 16:30 55.0
6 22:00 OFF 6 22:30 OFF
Preset Programmes
Your WP75-RF comes ready programmed with a set of operating
times and temperatures which often suit most people.
Please note: In order to reduce the risk of Legionella infection, it is
recommended that water temperature be set to not less than 60°C for
at least one event each day.
If you want to change any of these settings you can do so by
following the instructions on pages 13-15.
First, follow the steps on page 11-12 to set the correct time and date.
Before you start
Open the fl ap on the front of your
programmer. Using a non-metallic
object, press the recessed RESET button,
until you hear a click and the display
goes momentarily blank.
This will reinstate the preset programmes
and will set the time to 12:00 on Day 1.
Preset Programmes & Resetting the unit
BOOST
ON
OFF
AUTO
ALLDAY
12
Setting the Time/Day & Running the programme
Setting the Time & Day
Press PROG until the time and day number
begin to blink in the display.
DAY - Press DAY until correct day is shown
(1=Monday, 2=Tuesday etc).
TIME - Press + and - to change time (press
and hold to change in 10 min increments).
Press PROG again to accept the settings.
If you are happy to use the preset
programmes on page 11, you don’t need to
do anything else.
Press PROG until colon fl ashes in display.
Your unit is in RUN mode and your hot
water will be heated according to the preset
programmes.
Running your programme
To
change
DAY
To change TIME
13
!
Changing the programmes
Please Note
The unit must be programmed in sequence and ON/OFF
times cannot be programmed out of sequence.
If you want to leave a preset time as it is, simply press
PROG to move on to the next setting.
If at any time you get confused and need to reset the
unit to the preset programmes, press and hold the
recessed RESET button, using a non-metallic object
(see page 11).
Before you change the preset programme
Your installer will have set your unit to operate in either 7-day
mode or 5/2 day mode.
To tell which mode your unit is set press PROG until Event 1 fl ashes
in the display.
If your display looks like this, your unit is
in 7-day mode and you can programme
different settings for each day of the week
(see page 14).
If your display looks like this, your unit is in
5/2 day mode and you can enter one set
of programmes for weekdays and another
set for weekends (see page 15).
14
a) Press PROG until Event 1 fl ashes, then
press DAY to move from current day to
Day 1 (Event 1, Day 1).
b) Amend the time and temperature as
follows:
i) Use + and – buttons to alter time
(press and hold to change in 10 min
increments).
ii) Use and buttons to alter the water
temperature in 0.5°C (1°F) steps.
iii) Press NEXT to advance to next preset time
and temperature (Event 2, Day 1).
iv) Repeat steps i, ii & iii above for Events 2,
3, 4, 5 & 6.
c) When all 6 events are correct, press DAY
to programme events for Day 2.
(If you wish to repeat the previous days
programme, simply press COPY) .
d) Repeat steps i-iii above to programme
(or COPY) events for Days 3, 4, 5, 6 & 7.
Press PROG until the colon in the LCD display
starts to fl ash.
The unit is now in RUN mode and your
hot water will come on and go off at the
programmed times.
Proceed to page 16.
Programming in 7-day mode
(separate programmes for each day of the week)
Programming in 7-day mode
15
For Days 1-5 (weekdays)
a) Press PROG until Event 1 fl ashes in
display (Event 1, Days 1,2,3,4,5).
b) Use + and – buttons to alter time
(press and hold to change in 10 min
increments).
c) Use and buttons to alter the water
temperature in 0.5°C (1°F) steps.
d) Press NEXT to move to next preset time &
temperature (Event 2, Days 1,2,3,4,5).
e) Repeat steps b, c & d for programming
Events 3, 4, 5 & 6.
For Days 6-7 (weekends)
Press PROG until Event 1 fl ashes in
display (Event 1 Days 6-7).
Repeat steps b, c and d above to
programme time and temperature
events for the weekend.
Press PROG until the colon in the LCD display
starts to fl ash.
The unit is now in RUN mode and your
hot water will come on and go off at the
programmed times.
Proceed to page 16.
Programming in 5/2 day mode
(one set of programmes for weekdays, another set for weekends)
Programming in 5/2-day mode
16
Running your programme
Running your programme
To run the hot water programme press
the SELECT button.
As you press the SELECT button a bar in
the display will move to indicate which
RUN mode has been selected.
The four available functions and their meanings are as follows:
Select the option you require, depending on your circumstances,
time of year, etc.
BOOST
ON
OFF
AUTO
ALLDAY
ON = the water will be heated continuously to the
highest temperature set for the day shown on the
display.
OFF = the water will not be heated at all (unless the
BOOST button is pressed - then the water will be
heated to the highest temperature set for the day.
When this temperature is achieved the thermostat
with revert to OFF.)
AUTO = the water will come on and go off at the
programmed times.
ALLDAY = the water will remain on from setting 1
(1st ON) through to setting 6 (last OFF), at the highest
temperature set for the day.
17
BOOST Function and Hot Water Available Function
BOOST function
Sometimes you may have an immediate requirement for hot water
which is outside the set programme.
For instant hot water press the BOOST button.
If the system is OFF when you press BOOST - the water
will heat up to the highest setting of the day and then turn
itself off again.
If the system is ON when you press BOOST - the water will
heat up to the highest setting of the day (but only if the
current programmed temperature is lower).
Hot Water Available function
Sometimes you may need to know how much hot water there is in
your tank. With the WP75-RF a simple ‘hot water available function
is included.
To see an approximate indication of how much hot
water is currently stored press the and buttons
simultaneously.
The number of horizontal bars displayed indicates approximately
how much hot water is available at the temperature shown.
18
Hot Water Available function and Changing Clocks
Cylinder more than full of
hot water.
Cylinder between and
full of hot water.
Cylinder less than full of
hot water.
Open the fl ap on the front of the unit to
reveal the programming buttons.
To change from Summer to Winter
(clocks back) -
press and hold - button
To change from Winter to Summer
(clocks forward) -
press and hold + button
Changing clocks forward & back
Take care when making this change for the fi rst time. If
it is made in the wrong direction the unit will have to be
reset and any user-settings re-entered.
(See pages 11-12 on how to Reset the unit and how to set
the Time & Day)
!
NOTE: After the fi rst time this change has been made this
feature will only allow the clock to be changed in the opposite
direction.
19
Battery Replacement
When batteries are low a battery
symbol will fl ash in the LCD display.
You have 2 weeks to replace the
battery before the unit will switch off.
When changing batteries, remove old batteries and insert new
ones within one minute and programming will not be lost.
IMPORTANT: use 2 x AA size (LR6) high quality alkaline dry
cell batteries.
NB. If the display ever goes blank during normal operation, the
batteries will need to be renewed, the unit reset and the time and
programmes reset.
!
Battery replacement
20
Danfoss Randall Ltd
Ampthill Road
Bedford
MK42 9ER
Tel: 01234 364621
Fax: 01234 219705
Part No 34248 Issue 5 06/06
Still having problems?
Call your local heating engineer:
Name:
Tel:
For problems relating to your heating controls ...
Visit our website:
www.danfoss-randall.co.uk
Email our technical department:
drl_technical@danfoss.com
Call our technical department
0845 121 7505
(8.45-5.15 Mon-Thurs, 8.45-4.45 Fri)
For a large print version of these instructions
please contact the Marketing Services
Department on 0845 121 7400.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12