Triax TMB 100-1 User manual

Type
User manual

This manual is also suitable for

Model Item no.
TMB 100, 100-1 & TMB 100S
Version 2.1 10 - 2015 EN
triax.com
TMB 100, 100-1 & TMB 100S
Programmable Multiband Amplier
Pregrammable Amplifier
TMB 100, 100-1 & TMB 100S
General information ........................................................................................................................... 3
Safety instructions............................................................................................................................. 3
Installing the unit ............................................................................................................................... 4
Programming the unit........................................................................................................................ 5
Configuring the unit........................................................................................................................... 6
Operating principle ...................................................................................................................... 6
Menus : ........................................................................................................................................ 6
Flow chart ........................................................................................................................................... 7
Menus .................................................................................................................................................. 8
Config menu .................................................................................................................................... 8
Configuration of filter distribution ..................................................................................................... 8
Input amplifier setting. ..................................................................................................................... 9
Selection of remote power supply voltage. ...................................................................................... 9
Remote power supply setup. ......................................................................................................... 10
LTE function ................................................................................................................................. 10
Import and export menu ................................................................................................................ 11
PIN Code ....................................................................................................................................... 12
Language selection and Temperature display .............................................................................. 12
UHF filters setup. ........................................................................................................................... 13
Setting the levels. .......................................................................................................................... 14
AGC ............................................................................................................................................... 14
Auto level ....................................................................................................................................... 14
SAT Menu ...................................................................................................................................... 15
TMB 100S Diagram .......................................................................................................................... 16
Pregrammable Amplifier
TMB 100, 100-1 & TMB 100S
G
G
G
e
e
e
n
n
n
e
e
e
r
r
r
a
a
a
l
l
l
i
i
i
n
n
n
f
f
f
o
o
o
r
r
r
m
m
m
a
a
a
t
t
t
i
i
i
o
o
o
n
n
n
The processing units in the TMB100 range are used to selectively filter digital and analogue UHF
channels. These units also couple and amplify VHF programmes according to the satellite band
model (IF).
TMB100 units have 10 UHF filters, distributed over 3 inputs with programmable bandwidth from 1 to
7 channels (8 to 56 MHz), making it suitable for most situations.
An individual setting for each filter or frequency band, and automatic control of the UHF output level,
for aligning service plan levels.
TMB-100 part no. 360223 with wall-plug PSU
TMB-100-1 part no 360227 with desktop PSU
5 inputs:
BI + FM, BIII-DAB, UHF1, UHF2, UHF3
Gain UHF = 55 dB
Gain BIII = 48 dB
Gain BI-FM = 32 dB
Output level (max.) UHF = 117 dBµV @ IMR -60 dBc
TMB-100S part no. 324580
6 inputs:
BI + FM, BIII, UHF1, UHF2, UHF3, SAT
Gain Sat-IF = 40 dB
Gain UHF = 55 dB
Gain BIII = 48 dB
Gain BI-FM = 32 dB
Output level SAT (max.) = 118 dBµV @ IMR -35 dBc
Output level UHF (max.) = 115 dBµV @ IMR -60 dBc
S
S
S
a
a
a
f
f
f
e
e
e
t
t
t
y
y
y
i
i
i
n
n
n
s
s
s
t
t
t
r
r
r
u
u
u
c
c
c
t
t
t
i
i
i
o
o
o
n
n
n
s
s
s
Important: The unit should only be opened by a qualified technician.
Disconnect the unit before carrying out any work on it, as some powered components are
dangerous (risk of electrical shock).
To maintain the temperature of the unit within its normal operating range, ensure the free
circulation of air around the unit (avoid placing it in enclosed spaces). The ventilation grids
must be free of any obstruction.
Ensure that no liquids can penetrate inside the unit (splashes and/or run off).
Do not install the unit in a damp place. If there are traces of condensation on the unit, do not
use it until it has dried completely.
The mains power cable and the HF connection cables must be in good condition and free to
move (neither crushed nor obstructed).
The mains plug, easily accessible for the technician, must be out of reach of children.
Grounding of the unit
Your aerial installation must comply with the requirements specified by the European
provisions EN 50083-11 (conformity of collective installations) and EN 60065 (standards in
force for electrical protection).
Replacing fuses
Only a qualified technician can replace defective fuses.
Electromagnetic compatibility (EMC)
Ensure that the screws on the box are properly tightened.
Cables and connection terminals should show no signs of rust.
Pregrammable Amplifier
TMB 100, 100-1 & TMB 100S
I
I
I
n
n
n
s
s
s
t
t
t
a
a
a
l
l
l
l
l
l
i
i
i
n
n
n
g
g
g
t
t
t
h
h
h
e
e
e
u
u
u
n
n
n
i
i
i
t
t
t
We recommend you install the unit in a sufficiently ventilated place. Natural ventilation must be able
to occur through the ventilation grids; leave a minimum space of 15 cm around the unit to ensure
maximum ventilation. When installing or cabling the unit, we recommend you disconnect the
mains power cable.
Connecting the unit
Note: UHF inputs are remotely supplied and protected against short circuits. The power available is
12 or 24V, 50mA max. The preamplifier is detected automatically; only the remote power voltage
can be programmed.
Output
Entradas
UHF1 UHF2
Entrée
BI/FM
Conector
D
atos
Entrada
BIII/DA
Sat input
Keypad
Display
Inputs BI-FM BIII UHF Interface RS232
Earthing
connector
Pregrammable Amplifier
TMB 100, 100-1 & TMB 100S
P
P
P
r
r
r
o
o
o
g
g
g
r
r
r
a
a
a
m
m
m
m
m
m
i
i
i
n
n
n
g
g
g
t
t
t
h
h
h
e
e
e
u
u
u
n
n
n
i
i
i
t
t
t
A 4-digit display and a keypad are all you need to programme the unit. Follow the procedure below
for configuring the various parameters.
When the unit is powered on:
the programme mode is in standby:
by default, the system is configured as follows:
o UHF1 3 UHF filters
o UHF2 0 UHF filters
o UHF3 7 UHF filters
all the UHF filters are deactivated (display "
- -"),
the attenuators are at zero.
Factory reset
If necessary, to revert to factory settings, follow the procedure below:
1. Disconnect the power cable
2. Press the
esc button and hold it
3. Connect the power cable
The unit erases all the programming parameters, including the PIN code, and switches to standby
mode.
You can release the
esc button when the display shows "Default Settings".
- Running through the menus ,
- Decrement the value "-"
Back to previous menu (
^
)
Save the value (
V
)
- scrolling through the menus ,
- Increment the value "+"
Pregrammable Amplifier
TMB 100, 100-1 & TMB 100S
C
C
C
o
o
o
n
n
n
f
f
f
i
i
i
g
g
g
u
u
u
r
r
r
i
i
i
n
n
n
g
g
g
t
t
t
h
h
h
e
e
e
u
u
u
n
n
n
i
i
i
t
t
t
On powering on, the unit is in standby mode, a light segments flashes across the display.
Operating principle
To access the configuration menus, press a button
To summarize:
To scroll through the menus, use the + / - buttons.
To enter a menu, press enter.
To exit a menu, press the esc button
Press the Menu button to have a quick access to the CONFIG menu
Note:
If the button is not pressed for one minute, the unit switches to standby mode.
Menus :
Pregrammable Amplifier
TMB 100, 100-1 & TMB 100S
F
F
F
l
l
l
o
o
o
w
w
w
c
c
c
h
h
h
a
a
a
r
r
r
t
t
t
Pregrammable Amplifier
TMB 100, 100-1 & TMB 100S
M
M
M
e
e
e
n
n
n
u
u
u
s
s
s
Config menu
This menu allows:
Configuration of filter distribution on UHF1, 2 and 3 inputs. Comb 0010
Switch on/off the input amplifiers Ampx on/off
Selection of remote power supply (12 or 24 VDC). 12 or 24 VDC
Select the remote power for the UHF inputs VDCx on/off
To limit the UHF channels at channel 60 LTE on / off
Import or export a configuration file Import/Export
Activate the PIN code menu
Select the language Ang/Esp
Display the internal temperature
Configuration of filter distribution
Unit in standby mode, push a button to reach the CONFIG menu.
Press the enter button to reach the Comb menu.
Press enter again to change the configuration of the UHF inputs (part of the
display flashes)
Press the buttons + or - to select the distribution of the filters over the UHF inputs.
Confirm by pressing enter
Notes:
Each UHF filter can be deactivated. Just configure the filter in question to the value "off".
Input UHF1 UHF2 UHF3
352
172
082
307
109
0 0 10
Number of filters per
UHF input
Pregrammable Amplifier
TMB 100, 100-1 & TMB 100S
Input amplifier setting.
Unit in standby mode, push a button to reach the CONFIG menu.
Press the enter button to select the Comb menu.
Press the button to reach the AmpX menu.
Press enter to activate the menu
Press the buttons + or - to change the configuration of the UHF input amplifiers (on/off)
Confirm by pressing enter
Selection of remote power supply voltage.
Unit in standby mode, push a button to reach the CONFIG menu.
Press the enter button to select the Comb menu.
Press the button 2 times to reach Vdcx menu.
Press the enter to activate the menu
Press the buttons + or - to select the Voltage (12 or 24 VDC)
Confirm by pressing enter
Enter
Enter
CONFIG
Comb 0010
CONFIG
Vdc 12V
CONFIG
Comb 0010
Enter
CONFIG
Vdc 12V/24V
Enter
<CONFIG>
Enter
2x
Pregrammable Amplifier
TMB 100, 100-1 & TMB 100S
Remote power supply setup.
Enter
Enter
CONFIG
Comb 0010
CONFIG
Vdc 12V
CONFIG
Comb 0010
CONFIG
Amp3 on/off
CONFIG
Amp2 on/off
CONFIG
Amp3 on
CONFIG
Amp2 on
CONFIG
Amp1 on/off
CONFIG
Amp1 on
Enter
Enter
Enter
CONFIG
Vdc 12V/24V
Enter
<CONFIG>
Enter
CONFIG
VDC1 on/off
CONFIG
VDC1 off
Enter
Enter
CONFIG
VDC2 on
CONFIG
VDC3 on
CONFIG
VDC2 on/off
Enter
Enter
CONFIG
VDC3 on/off
Enter
Enter
Unit in standby mode, push a button to reach the CONFIG menu.
Press the enter button to select the Comb menu.
Press the button 3 times to reach VDCx menu.
Press enter to activate the menu
Press the buttons + or - to change the configuration (on/off)
Confirm by pressing enter
Press the button to reach the other inputs and repeat the process.
LTE function
This function limits the filter setting on channel 60.
<CONFIG>
Enter
Enter
Enter
CONFIG
Comb 0010
CONFIG
Comb 0010
CONFIG
LTE on
Enter
CONFIG
LTE on/off
Enter
X times
Unit in standby mode, push a button to reach the CONFIG menu.
Press the enter button to select the Comb menu.
Press the several times to reach LTE menu.
Press enter to activate the menu
Press the buttons + or - to change the configuration (on/off)
Confirm by pressing enter
LTE = off 21 - 60
Pregrammable Amplifier
TMB 100, 100-1 & TMB 100S
Import and export menu
Unit in standby mode, push a button to reach the CONFIG menu.
Press the enter button to select the Comb menu.
Press the several times to reach Import or Export menu.
Press enter to activate the menu
Press the buttons + or - to select the file (SE00x)
Confirm by pressing enter
The TMB units are equiped with RS232 interface, please used an RS232/SD adapter to store your
configuration files.
Important.
When using these menus and no SD card is available the display shows NoSD.
The SD/MMC card should be in FAT16 format. Files should be in root directory.
Pregrammable Amplifier
TMB 100, 100-1 & TMB 100S
PIN Code
Unit in standby mode, push a button to reach the CONFIG menu.
Press the enter button to select the Comb menu.
Press the several times to reach PIN menu.
Press enter to activate the menu
Press the buttons + or - to change the configuration (on/off)
Confirm by pressing enter
Choose your PIN code (only if on is selected)
o
Press enter to activate the menu
o Press the buttons + or - to change the number
o Confirm by pressing enter
o Do the same for the other digits
Language selection and Temperature display
Default PIN code: 2312
Pregrammable Amplifier
TMB 100, 100-1 & TMB 100S
UHF filters setup.
Unit in standby mode, push a button to reach the CONFIG menu.
Press the button to reach the CHAN menu.
Press enter to activate the menu
Press enter again to setup the UHF filter
Press the buttons + or - to select the start channel
Confirm by pressing enter
Press the buttons + or - to select the end channel
Confirm by pressing enter
Press the button to setup the next channel
Notice:
The number of filter is according to the configuration of filter distribution
In LTE mode = off only channel 21 to 60 are available.
=
CHAN
xP off
CHAN
3P off
CHAN
1P off
Enter
Enter
Enter
CHAN
1P 21-21
When channel is
always used
Err
Enter
CHAN
1P 21-21
CHAN
2P off
<CONFIG>
< CHAN >
Pregrammable Amplifier
TMB 100, 100-1 & TMB 100S
Setting the levels.
There are three types of level setting:
“Manual” setting of output levels (Gain menu)
automatic alignment of UHF filter output levels to a value entered by the user. (Auto menu,
sub-menu Level)
automatic UHF gain control (Menu Auto, sub-menu AGC)
Unit in standby mode, push a button to reach the CONFIG menu.
Press the button several times to reach the Gain menu.
Press enter to activate the menu
Press the or button to setup the VHF, UHF or Filter gain
Confirm by pressing enter
Press the buttons + or - to change the value
Confirm by pressing enter
Press the or button to setup the next gain
Notice:
The number of filter is according to the on/off filter setting
AGC
Unit in standby mode, push a button to reach the CONFIG menu.
Press the button several times to reach the Auto/AGC menu.
Press enter to activate the AGC menu
Press the buttons + or - to change the value
Confirm by pressing enter
Press the buttons + or - to change the value
Confirm by pressing enter
Auto level
Unit in standby mode, push a button to reach the CONFIG menu.
Press the button several times to reach the Auto/Level menu.
Press enter to activate the Level menu
Press the buttons + or - to change the value
Confirm by pressing enter
Press the buttons + or - to change the value
Confirm by pressing enter
Pregrammable Amplifier
TMB 100, 100-1 & TMB 100S
IMPORTANT!
AGC: The unit memorizes the average output level. A variation of ± 1 dB triggers the
function and compensates the variation within gain and attenuation limits
AGC mode hides all other menus. To modify the parameters, switch the AGC mode to OFF
.
Auto Level: The unit memorizes the selected output level, the function try to reach the value
within input, gain and attenuation limits.
Note: Setting of the levels BI-II / BIII is not automatic.
SAT Menu
TMB 100S models have one IF amplification path. The Sat menu is used to configure the remote
power supply of the LNB (OFF / 13 /17 V
DC), to activate the 22kHz generator and the 9dB equalizer.
Unit in standby mode, push a button to reach the CONFIG menu.
Press the button several times to reach the SAT menu.
Press enter to activate the SAT menu
Press the or button to select the Supp, Gain, Eq, Pol or Band menu.
o Supp (power on or off)
o Gain
o Eq (Equalizer 0dB_off or 9dB_on)
o Pol (H or V polarization)
o Band (Lo/H Band)
Press enter to activate the selected menu
Press the buttons + or - to change the value
Confirm by pressing enter
Pregrammable Amplifier
TMB 100, 100-1 & TMB 100S
T
T
T
M
M
M
B
B
B
1
1
1
0
0
0
0
0
0
S
S
S
D
D
D
i
i
i
a
a
a
g
g
g
r
r
r
a
a
a
m
m
m
Note: Model TMB 100 does not have impmented the SAT path
Make a note of your filter setup:
Gain AGC Level
BI - FM 47 .,. 108 MHz
BIII 174 ... 230 MHz
Filter 1
(1
..
7 K
an
äl
e
) 8
..
56 MH
z
Filter
2
(1 .. 7 Kanäle) 8 .. 56 MHz
Filter
3
(1
..
7 K
an
äl
e
) 8
..
56 MH
z
Filter 4
(1
..
7 K
an
äl
e
) 8
..
56 MH
z
Filter 5
(1
..
7 K
an
äl
e
) 8
..
56 MH
z
Filter
6
(1
..
7 K
an
äl
e
) 8
..
56 MH
z
Filter7
(1 .. 7 Kanäle) 8 .. 56 MHz
Filter
8
(1
..
7 K
an
äl
e
) 8
..
56 MH
z
Filter 9
(1
..
7 K
an
äl
e
) 8
..
56 MH
z
Filter 1
(1
..
7 K
an
äl
e
) 8
..
56 MH
z
V
alue
UHF1
2 filter
UHF2
8, 7 oder 5 filter
UHF3
0, 1 ou 3 filter
Bandwidth of the filter
S1
0/12/24V 0/12/24V
BI/FM UHF1 VHF UHF3
OUT
S2 S3
P
P
P
P
P
P
P
P
P
P1
SU3
SU1
AGC
0-20dB
0/12/24V
UHF2
S4
SU2
0/9dB
SAT
0-20dB
0-20dB 0-20dB 0-20dB
0/13/17V
0/22kHz
Pregrammable Amplifier
TMB 100, 100-1 & TMB 100S
Technical Specifications
Type
Part nr.
Units
Number of inputs
AMPLIFICATION
Max. BI+FM / BIII / UHF / SAT input level
dB
BI+FM (47 .. 108 MHz) gain
dB
BIII (174 .. 230 MHz) gain
dB
UHF ("LTE on": 470 .. 790 MHz; "LTE off": 47 .. 862 MHz) gain
dB
SAT (950 .. 2150 MHz) gain
dB
Pre-emphasis SAT path
dB
BI+FM / BIII / UHF / SAT Noise Figure
dB
Attenuator per input
dB
Global UHF attenuator
dB
M
ax. Output level BI / BIII / UHF (IM
3
-60dB) / SAT (IM
3
-35 dBc)
dBµV
FILTERING
Selectable filter allocations UHF1 / UHF2 / UHF3 3 5 2 3 5 2
172172
-82 - 82
3-73-7
1-91-9
- - 10 - - 10
Bandidth of filtering channels
MHz
Filter selectivity @ ± 16 MHz
dB
BI+FM / BIII / UHF / SAT Input return loss
dB
Output return loss
dB
CONDITIONS of OPERATION
Power supply (50-60 Hz)
VAC
P
ower consumption at 230VAC (dependent on remote supplying)
W
External PSU with Euro plug TMB 100 // TMB 100-1, 100S
V / A
Remote supply UHF 1, 2 or 3
V / mA
Input equiped with remote supply
LNB power supply
V / mA
22 kHz generator on Sat input
Operating temperature
°C
MECHANICS
Input/output connectors
Dimensions (H xW x D)
mm
CONFORMITY
CE 2004/108/EC (EMC Directive) und
2006/95/EC (Low Voltage Directive)
ROHS 2011/65/EC (RoHS Directive)
>14
> 8 / 10 / 8 / -
0 ... 20
0 ... 20
120/120 / 117 / -
// Desktop 12 / 2,5Wall-plug 12/1,25
-5 ... +40
> 8 / 8 / 8 / -
UHF 1, 2 and 3
100…240
9…16
90 / 80 / 95 / -
32
48
55
9 / 5 / 7 / -
8 .. 56 (1…7 Ch)
12 or 24 / 80
0 /13or 17
ON / OFF
>14
> 8 / 10 / 8 / 6
12 or 24 / 80
12…18
8 .. 56 (1…7 Ch)
UHF 1, 2 and 3
5
TMB 100, 100-1
360223, 360227
TMB 100S
324580
6
55
32
48
90 / 80 / 95 / 80
120 / 120 / 115 / 118
-5 ... +40
"F" femal
225 x 220 x 50
0/9 (switchable)
40
0 ... 20
9 / 5 / 7 / 7
0 ... 20
> 8 / 8 / 8 / 8
100...240
TRIAX A/S
Bjoernkaervej 3
DK-8783 Hornsyld
Tel. +45 76 82 00
Fax +45 88 20 04 20
www.triax.com
Copyright © 2016 TRIAX. All rights reserved. The TRIAX Logo and TRIAX, TRIAX Multimedia
are registered trademarks or trademarks of the TRIAX Company or its afliates.
All specications in this guide are subject to change without further notice.
TRIAX A/S | Bjørnkærvej 3 | DK-8783 Hornsyld | Denmark
triax.com/support
your ultimate connection10-2015 - V 2.1
TRIAX A/S
Bjørnkærvej 3 • DK-8783 Hornsyld
Tel: +45 76 82 22 00 • Fax: +45 88 20 04 20
mail: [email protected] • www.triax.com
User Manual • Notice d’utilisation • Manual de usuario • Betriebsanleitung
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18

Triax TMB 100-1 User manual

Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI