Symantec J5300 40T Quick start guide

Type
Quick start guide
Quick Start Guide
Security Analytics J5300 40T Direct-Attached Storage
Page 1
Date of Publication: 15 August 2017
SA-J5300-DAS-40T
Security Analytics appliances that have two RAID controllers can support up to three storage
modules per RAID controller. Attach the storage modules to the head unit in the order shown
below, using SAS-3 to SAS-3 cables:
Extend the rail to the front post and insert the studs into the corresponding mounting posts.
a. Use the rail screws to anchor the rail to the
front post.
b. After verifying that the rails are aligned,
secure, and stable, place the enclosure on
therails.
c. Insert the screws through the mounting holes
on either side of the enclosure and then
secure them with the cage nuts.
d. Replace the drives in the enclosure.
Two sets of cables are included with the J5300: one set for a SAS-3 environment and another for a
mixed SAS-2 and SAS-3 environment.
Orient each rail so that the L-shaped shelf is at the bottom and toward the front of therack.
a. Press the spring lock on the other end of the
rail, insert the studs into the holes on the
rear post, and release the lock so that it grips
the rail.
b. Use the rail screws to anchor the rail to the
rear post.
01
Unpack the shipment container and verify the contents of the box. Security Analytics J5300 40T
Direct-Attached Storage ships with the following components:
Before installing the J5300 enclosure in the rack, perform these steps:
a. Peel off the protective plastic sheet from the top and the bottom of the enclosure.
b. Remove the drives from the enclosure to reduce the weight:
o Press the release button on each drive to
unlock the drive carrier. The drive-carrier
handle swings out.
o Grasp the handle and gently pull the
drive carrier out of the J5300 and place it
on a static-free surface.
To install the J5300 enclosure into a rack with the supplied mounting rails:
a. Determine where to install the enclosureThree holes are required for the rear posts and five
for the front.
b. For square holes, insert a cage nut into the top mounting hole of the front posts.
Insert Cage Nut
Front Rail Mount
Rear Rail Mount
Module 5
Module 3
Module 1
Module 2
Module 4
Module 6
SAS-3 RAID Controller 2
SAS-3 RAID Controller 1
CAUTION: Adding storage modules is a destructive process, because all of the capture and
indexing drive arrays must be recongured. Do not begin to add new storage to an existing
system until after you have backed up all capture and indexing data.
SAS-3 to SAS-3
SFF-8644 to
SFF-8644
SAS-2 to SAS-3
SFF-8088 to
SFF-8644
Diagram
Symbol
Diagram
Symbol
o When attaching a SAS-3 cable to the J5300, the
release pull-tab must be on the underside of the
plug. You should hear a distinct click when it is
seated properly.
o When attaching SAS-2 or SAS-3 cables to the head
unit, the release pull-tab should be on the top side of
the plug.
Unpack the Storage Module
o J5300 Storage Module
o Two AC Power Cords
o Two SFF-8644 to SFF-8644 cables
o Two SFF-8644 to SFF-8088 cables
o Adjustable rack-mounting rail assembly
o Lift/carry reminder insert
o
Quick Start Guide
(this document)
o Safety and regulatory compliance inserts
02
Prepare the Enclosure for Rack-Mounting
03
Prepare to Install the Rails
Identify the SAS Cables
04
Properly Orient the Connectors
Attach the Rail to the Rear Post
05
06
Connecting the J5300 to SAS-3 RAID Controllers
08a
07
Attach the Rail to the Front Post; Secure the Enclosure
Copyright © 2017 Symantc Corp. All rights reserved. Symantec, the Symantec Logo, the Checkmark Logo, Blue Coat, and the Blue Coat logo are trademarks or registered trademarks of Symantec Corp. or its affiliates in the U.S. and other countries. Other names may be trademarks of their respective owners. This document is provided for informational purposes only and is
not intended as advertising. All warranties relating to the information in this document, either express or implied, are disclaimed to the maximum extent allowed by law. The information in this document is subject to change without notice. Part Number: 231-03280 Rev E.0
THE DOCUMENTATION IS PROVIDED “AS IS” AND ALL EXPRESS OR IMPLIED CONDITIONS, REPRESENTATIONS AND WARRANTIES, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE OR NON-INFRINGEMENT, ARE DISCLAIMED, EXCEPT TO THE EXTENT THAT SUCH DISCLAIMERS ARE HELD TO BE LEGALLY INVALID.
SYMANTEC CORPORATION SHALL NOT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES IN CONNECTION WITH THE FURNISHING, PERFORMANCE, OR USE OF THIS DOCUMENTATION. THE INFORMATION CONTAINED IN THIS DOCUMENTATION IS SUBJECT TO CHANGE WITHOUT NOTICE. SYMANTEC CORPORATION PRODUCTS, TECHNICAL SERVICES, AND ANY
OTHER TECHNICAL DATA REFERENCED IN THIS DOCUMENT ARE SUBJECT TO U.S. EXPORT CONTROL AND SANCTIONS LAWS, REGULATIONS AND REQUIREMENTS, AND MAY BE SUBJECT TO EXPORT OR IMPORT REGULATIONS IN OTHER COUNTRIES. YOU AGREE TO COMPLY STRICTLY WITH THESE LAWS, REGULATIONS AND REQUIREMENTS, AND ACKNOWLEDGE THAT
YOU HAVE THE RESPONSIBILITY TO OBTAIN ANY LICENSES, PERMITS OR OTHER APPROVALS THAT MAY BE REQUIRED IN ORDER TO EXPORT, RE-EXPORT, TRANSFER IN COUNTRY OR IMPORT AFTER DELIVERY TO YOU.
Page 2
Technical Support
o Contact Informationhttps://support.symantec.com/en_US/contact-support.html
o MySymantechttps://mysymantec.force.com/customer/s/
Documentation
o Go to https://support.symantec.com/en_US/Documentation.html and search for
"Security Analytics"
o Select Administration Guide or Hardware Guide for the document type.
When adding J5300 storage modules to an existing SAS-2 system keep the following in mind:
o Adding storage modules is a destructive process: Do not begin to add new storage until after
you have backed up all data.
o Contact Symantec support for assistance in calculating the new drive allocation.
231-03280 rev E.0
Module 5
Module 3
Module 1
Module 2
Module 4
Module 6
SAS-2 RAID Controller 1
SAS-2 RAID Controller 2
1 Controller Status
2 Internal Use Only
3 Not Used
4 SFF-8644 SAS Ports
5 Power Supply On/Off Switch
6 AC Power Indicator
7 Fault Indicator
8 Not Used
9 DC Power-Supply Status
10 Standby Power Indicator
1 AC Power Indicator
2 Global Enclosure Status
3 Controller 1 Activity
4 Controller 2 Activity
5 System Heartbeat
6 Drive Status
7 Drive Power/Activity
Existing
SAS-2 to
SAS-2
Cabling
Security Analytics appliances that have one RAID controller can support one storage
moduleonly. For SAS-2 RAID controllers, attach the storage module to the head unit using
SAS-2 to SAS-3cables.
SAS-2 RAID Controller SAS-3 RAID Controller
Integrating the J5300 with an Existing SAS-2 Environment
Module and Power-Supply Indicators
Front-Panel and Drive Indicators
Connecting a J5300 to a Single RAID Controller
08c
08b
If you are connecting only one storage module to a unit that has two RAID controllers, DO NOT
connect the module to both RAID controllers.
SAS-3 RAID ControllersSAS-2 RAID Controllers
  • Page 1 1
  • Page 2 2

Symantec J5300 40T Quick start guide

Type
Quick start guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI