IS-44340LED-US
We’re here to help 866-558-5706
Hrs: M-F 9am to 5pm EST
1) Pass wire through stems[A] and small threaded tubes[B]
and screw stems into couplings[G] on top of xture body[H].
NOTE: Thread locking compound must be applied to all stem
threads as noted with symbol (4) to prevent accidental
rotaon of xture during cleaning,relamping, etc.
2) Pass xture wire through remaining stems and screw stems
together.
3) On one side of xture, pass xture wire through one small
threaded pipe[K]. Screw each small threaded pipe onto top of
stem on each side.
4) On one side of xture, pass xture wires through each hole in
canopy[F]. Lower canopy down towards stems. Pass each hole
in canopy over end of each threaded pipe on top of stems.
5) On one side of xture, pass xture wire through
lockwasher[P]. Thread lockwasher onto end of threaded
pipe protruding from inside canopy. Pass xture wire through
hexnut[Q]. Thread hexnut onto end of threaded pipe.
6) Repeat to other threaded pipe.
7) Aach mounng plate[D] to outlet box[C] using the strap
mounng screws[E]. Mounng strap can be adjusted to suit
posion of xture.
8) Grounding instrucons: (See Illus. a or b).
a) On xtures where mounng strap is provided with a hole
and two raised dimples, wrap ground wire from outlet
box around green ground screw, and thread into hole.
b) On xtures where a cupped washer is provided, aach
ground wire from outlet box under cupped washer and
green ground screw, and thread into mounng strap.
If xture is provided with ground wire, connect xture ground
wire to outlet box ground wire with wire connector (not
provided.) aer following the above steps. Never connect
ground wire to black or white power supply wires.
9) Cut the wire to length for wiring and make wire connecons
to the driver aer stems[A] have been installed per wiring
Diagram “A’ in view above the canopy[F] using supplied wire
nuts[R].
10) Make wire connecon. Reference chart below for correct
connecons and wire accordingly.
Connect Black or Red
Supply Wire to:
Connect White Supply Wire
to:
Black White
*Parallel cord (round &
smooth)
*Parallel cord (square &
ridged)
Clear, Brown, Gold or Black
without Tracer
Clear, Brown, Gold or Black
with Tracer
Insulated wire (other
than green) with copper
conductor
Insulated wire (other than
green) with silver conductor
*Note: When parallel wire (SPT 1 &
SPT 2) are used. The neutral wire
is square shaped or ridged and the
other wire will be round in shape or
smooth (See illus.)
Neutral Wire
11) Push xture to ceiling, carefully passing mounng screws
through holes in canopy. NOTE: Be certain wires do not get
pinched between mounng strap and canopy.
12) Secure xture to ceiling with the four (4) at head machine
screws[L] through the sides of the canopy as shown.
13) Install the six (6) glass spacers[M] with pads on the top as
shown.
14) Carefully install the glass[N] by raising up to the sides and
using the decorave knobs[O] secure the glass into place as
shown.
Installaon Instrucons – Loop/Chain Link Mount
1) Follow steps 1 and 4 from Rigid Stem Mount Instrucons.
2) Thread one small threaded pipe[K] into end of each small
loop[J].
3) Pass xture wire through rst loop. Thread rst loop onto end
of each last stem.
4) On one side of xture, pass xture wire through second loop
and through hole in canopy[F]. Pass threaded pipe at end of
second loop through hole in canopy.
5) Pass xture wire through lockwasher[P]. Thread lockwasher
onto end of threaded pipe protruding from inside canopy.
6) Pass xture wire through hexnut[Q]. Thread hexnut onto end
of threaded pipe.
7) On other side of xture, pass xture wire through second
loop and through hole in canopy. Pass threaded pipe at end of
second loop through hole in canopy.
8) Pass xture wire through lockwasher. Thread lockwasher onto
end of threaded pipe protruding from inside canopy.
9) Pass xture wire through hexnut. Thread hexnut onto end of
threaded pipe.
10) Aach locking link[I] to small loop at end of each stem and to
each loop on canopy.
11) Follow steps 7 - 14 from Rigid Stem Mount Instrucons.
GREEN GROUND
SCREW
CUPPED
WASHER
OUTLET BOX
GROUND
FIXTURE
GROUND
DIMPLES
WIRE CONNECTOR
OUTLET BOX
GROUND
GREEN GROUND
SCREW
FIXTURE
GROUND
a
b
Fixture Diagram
Parts List
Cauons
CAUTION – RISK OF SHOCK –
Disconnect Power at the main circuit breaker panel or main
fusebox before starng and during the installaon.
WARNING:
This xture is intended for installaon in accordance
with the Naonal Electrical Code (NEC) and all local code
specicaons. If you are not familiar with code requirements,
installaon by a cered electrician is recommended.
Installaon Instrucons – Rigid Stem Mount
Installaon Instrucons – Rigid Stem Mount (connued)
[A] Stems
[B] Small
Threaded
Tubes
[C] Outlet Box
[D] Mounting
Plate
[E] Strap
Mounting
Screws
[F] Canopy
[G] Couplings
[H] Fixture Body
[I] Chain Locking
Link
[J] Small Loop
[K] Small
Threaded Pipe
[L] Flat Head
Screws
[M] Glass Spacers
[N] Glass
[O] Decorative
Knobs
[P] Lockwasher
[Q] Hexnut
WIRING DIAGRAM "A"
DC+:RED
DC-: BLUE
INPUT:
120Vac, 50/60HZ
C
D
►
K
J
A
B
►
►
►
►
►
►
►
►
►
F
G
O
N
M
E
I
L
RED
BLUE
Q
P
R
H