Commercial Electric CER407943AK50WH Installation guide

Type
Installation guide

This manual is also suitable for

Connecting the wires
USE AND CARE GUIDE
____________________________________
THANK YOU
We appreciate the trust and confidence you have placed in Commercial Electric through the purchase of
this LED 4 inch downlight. We strive to continually create quality products designed to enhance your
home. Visit us online to see our full line of products available for your home improvement needs. Thank
you for choosing Commercial Electric!
PACKAGE CONTENTS
Questions, problems, missing parts? Before returning to the store,
call Commercial Electric Customer Service
8 a.m. 7 p.m., PST, Monday Friday
9 a.m. 6 p.m., PST, Saturday
1-877-527-0313
HOMEDEPOT.COM/COMMERCIALELECTRIC
Part Description Quantity
A Downlight 1
B Hole Template 1
C Wire Connector 3
WHAT IS COVERED
The manufacturer warrants this lighting fixture to be free from defects in materials and
workmanship for a period of five (5) years from date of purchase. This warranty applies
only to the original consumer purchaser and only to products used in normal use and
service. If this product is found to be defective, the manufacturer’s only obligation, and
your exclusive remedy, is the repair or replacement of the product at the manufacturer’s
discretion, provided that the product has not been damaged through misuse, abuse,
accident, modifications, alterations, neglect or mishandling.
WHAT IS NOT COVERED
This warranty shall not apply to any product that is found to have been improperly installed,
set-up, or used in any way not in accordance with the instructions supplied with the
product. This warranty shall not apply to a failure of the product as a result of an accident,
misuse, abuse, negligence, alteration, or faulty installation, or any other failure not relating
to faulty material or workmanship. This warranty shall not apply to the finish on any portion
of the product, such as surface and/or weathering, as this is considered normal wear and
tear.
The manufacturer does not warrant and specially disclaims any warranty, whether
expressed or implied, of fitness for a particular purpose, other than the warranty contained
herein. The manufacturer specifically disclaims any liability and shall not be liable for any
consequential or incidental loss or damage, including but not limited to any labor/expense
costs involved in the replacement or repair of said product.
Contact the Customer Service Team at 1-877-527-0313 or visit
HOMEDEPOT.COM/COMMERCIALELECTRIC.
Move the position of the switch on the fixture (A) to the desired color temperature.
Raise the fixture (A) to the ceiling hole while pushing the excess NM cable into the hole.
Flip the spring-loaded wings up and squeeze them until the wings reach the edge of
the hole.
Release the wings and push the fixture (A) up until both wings flip down onto the
ceiling surface.
Pre-Installation
WARNING: Disconnect the power prior to
removing or installing a light fixture.
Safety Information
All electrical connections must
be in accordance with local and
National Electrical Code
(N.E.C.) standards.
WARNING: Do not install in
a ceiling with spray foam
insulation.
Check if the power source is suitable for the
added electrical load. Power should be
supplied by a 110/120 volt, 60 Hz single
circuit. A standard 120 volt, 15 amp branch
circuit carries a maximum load of 1800 watts.
The total wattage of all the lights and
appliances on that circuit, should not exceed
80% (1440 watts) of the maximum electrical
capacity.
Pre-Installation (continued)
TOOLS REQUIRED
A
B
C
Installation
NOTE: Do not make the hole
larger than specified by the
template. An oversize hole
may not allow for proper
installation.
NOTE: Do not install this
fixture in ceiling surfaces
thicker than 0.75 in.
WARNING: Use only cables
that are rated for 90°C or
higher.
NM
or BX
This is an IC type fixture and may safely come in direct contact or completely covered
with thermal insulation that has an R-value of 3.85 or less. Some insulation types that
meet this requirement are blanket batting/roll and blown-in loose fill. Any part of this
fixture may safely come in direct contact with combustible materials such as ceiling
joists or floor boards.
To install this power supply wiring (NM cable) needs to be installed from the power
source to the hole.
This fixture is designed for ceiling surfaces that are 0.75 in. thick or less.
This fixture is suitable for wet or damp locations such as a shower stall or bathtub
enclosure, but the area above the ceiling surface must be a dry location.
To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or
other sharp objects.
Dimming
This device complies with part 15 of the FCC Rules. Operation is subject to the
following two conditions:
1. This device may not cause harmful interference, and
2. This device must accept any interference received, including interference that
may cause undesired operation.
NOTE: This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference in a residential installation.
This equipment generates, uses and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause harmful interference
to radio communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful interference to
radio or television reception, which can be determined by turning the equipment off
and on, the user is encouraged to try to correct the interference by one or more of the
following measures:
Reorient or relocate the receiver antenna.
Increase the separation between the equipment and receiver.
Install the product onto on a circuit different from that to which the receiver is
connected.
Consult with the dealer or an experienced radio/TV technician for help.
CAUTION: Any changes made to the electronics circuit will void this equipment’s
compliance with Part 15 of the FCC Rules and should not be operated.
____________________________________
Complies with CAN ICES-005 (B) / NMB-005 (B)
For a complete list of compatible dimmers, please look up the item number listed on
the cover of this instruction manual at HOMEDEPOT.COM.
FCC Notice
Installation (continued)
1
2
Preparing the location
Choose the location for the fixture, taking into
consideration the 6” depth clearance requirement,
the location of ceiling joists and the accessibility
for the electrical supply. Mark the selected location
with a circle using the provided template.
Using a keyhole saw make a 4.25 in. hole in the
ceiling surface.
Run non-metallic (NM) cable (Romex) or an
armored cable (BX) from your circuit breaker or
fuse panel to the hole.
Provide 6 to 8 inches (15.2 20.3 cm) of slack
below the hole. Wires between 0 AWG and 12
AWG may be used instead of NM or BX.
Open the side door of the fixture’s (A) junction box by loosening the bottom screw.
Remove one of the round knockouts located on the top or sides of the junction box if
you are using BX cable or a rectangular knockout on the back of the junction box if you
are using NM cable.
Insert about 5 or 6 in. of the NM cable into the junction box through one of the provided
strain-relief slots.
Remove 3 in. of the cable’s outer sheath and the plastic or paper over-wrap.
Strip approximately 3/8 in. of insulation from the ends of all supply wires.
Attach the black supply wire to the black fixture wire using wire nuts (C).
Attach the white supply wire to the white fixture wire using wire nuts (C).
Connect the fixture ground wire and the supply ground wire together using a wire nut
(C).
Tuck all the wires and the wire connections into the junction box and close the side
door by tightening the bottom screw.
LED 4 Inch Downlight
Warranty Operation
Care and Cleaning
Turn on power at the circuit breaker or fuse box.
Turn the light switch on to activate the fixture.
Use a dry or slightly dampened clean
cloth and wipe the surface of the fixture.
NOTE: Do not use any cleaners with
chemicals, solvents, or harsh abrasives.
Use only a dry soft cloth to dust or wipe
carefully.
Installation (continued)
Light Distribution
Item:
Model:
1003 240 056
CER407943K50WH
3
Securing the fixture
C
A
A
A
SYMPTOM SOLUTION
Lights flicker during
dimming.
If dimmer is not on list, replace it with a dimmer from
the list.
Fuse blows or circuit
breaker trips when light is
turned on.
If wiring connections are loose or disconnected, redo
connections. Make sure there are no exposed wire
conductors.
If wiring connections are good, the trim may be
defective and will need to be replaced.
Troubleshooting
Ladder
Phillips
Screwdriver
Safety
Goggles
Keyhole
Saw
WARNING: Changes or modifications not
expressly approved by the party
responsible for compliance could void the
user’s authority to operate the equipment.
  • Page 1 1
  • Page 2 2
  • Page 3 3

Commercial Electric CER407943AK50WH Installation guide

Type
Installation guide
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI