Dryer Electrical Supply Grounding
Instructions for 3-Wire Power Cord
2018-08
Mike Peebles
2018-08-13
Dryer Electrical Supply Grounding Instructions for 3-Wire Power Cord
Page 2
Dryer Installation Manual:
Current Dryer installation manuals have the following instructions for installing a 3-Wire Power Cord.
BSH Dryer Electrical Supply Grounding Instructions for 3-Wire Power Cord
Alternate Grounding Method:
As BSH condensate dryers have no internal Neutral, the following installation is permitted IF ALL instructions are
completed and confirmed.
1. Neutral wire of 3-Wire cord (usually white or middle
conductor) can be connected directly to PE as
shown.
2. BEFORE plugging power cord into the receptacle,
the continuity between the Neutral (center) pin of the
power cord and the metal frame of the appliance
MUST be confirmed.
Use of a self-energized circuit tester must be used.
Continuity
tester
NEMA
10-30P
Plug
3. A 4-conductor cord must be used when the appliance is installed where
grounding through the Neutral conductor is prohibited! Grounding through the
Neutral conductor is prohibited for (1) new branch-circuit installations, (2)
mobile homes, (3) recreational vehicles, and (4) areas where local codes
prohibit grounding through the Neutral conductors.
*8001013017*
8001013017 (9507)
$
$
%
&
&
PD[FP
$
PD[FP
PLQFPPD[FP
&
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

Bosch WTG86402UC Installation guide

Category
Cable network testers
Type
Installation guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI