SURFACE MOUNTING 4137ADK137AD CONSOLES
1. Mark the positions on the wall for the screw mounting holes and the
cut-out for the wiring.
2. Pull the interface wiring in the wall through the cut-out.
3. Remove the console’s back cover. The securing screw at the front
of the console (under the nameplate) must be removed to release
the back cover.
4. Pass tha interface wiring through the opening in the back cover,
then mount the back cover to the wall surface with screws.
5. Splice the interface wiring to the console harness wires and plug in
the harness connector. Insulated solderless wire splices (e.g., 311)
may be used for splicing.
6. Attach the main body of the console to the wall-mounted back
cover. The console is properly attached when it snaps into place.
Use the securing screw (previously removed) to secure the console
to the back cover.
Back cover of VISTA Console
that IS mounted to the wall
Pull interface wr!ng through hole
\ and splice to Console wres.
\
.
\
VISTA Console
SPECIFICATIONS
4137AD, 5137AD REMOTE CONSOLES
1. Physical: 8.4”W x 4.75”l-l x 1 .l “D
(213mm x 121 mm x 28mm)
2. Electrical: Voltage Input: 12VDC
Current Drain: 60mA (4137AD)
9OmA (5137AD)
3. Interface Wiring:
RED: 12VDC input (+)
BLUE: See Control’s instructions
GREEN: Data Out to Control
YELLOW: Data In from Control
BLACK: Ground,-and if used,
(-) connection from
supplementary power supply
(see Control’s instructions)
www.PDF-Zoo.com