  • Hello! I am an AI chatbot trained to assist you with the Broan-NuTone QTREN110FLT Installation guide. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
  • What are the electrical requirements for the Broan-NuTone QTREN110FLT?
    How do I install the Broan-NuTone QTREN110FLT?
    How do I clean the Broan-NuTone QTREN110FLT?
    What is the warranty for the Broan-NuTone QTREN110FLT?
    What are the dimensions of the Broan-NuTone QTREN110FLT?
Page 1
MODELS QTREN080FLT • QTREN110FLT
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR IN-
JURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer.
If you have questions, contact the manufacturer at the address
or telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service
panel and lock the service disconnecting means to prevent
power from being switched on accidentally. When the service
disconnecting means cannot be locked, securely fasten a
prominent warning device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by a
qualified person(s) in accordance with all applicable codes
and standards, including fire-rated construction codes and
standards.
4. Sufficient air is needed for proper combustion and exhausting
of gases through the flue (chimney) of fuel burning equip-
ment to prevent backdrafting. Follow the heating equipment
manufacturer’s guideline and safety standards such as those
published by the National Fire Protection Association (NFPA),
and the American Society for Heating, Refrigeration and Air
Conditioning Engineers (ASHRAE), and the local code authori-
ties.
5. When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. Acceptable for use over a tub or shower when connected to
a GFCI (Ground Fault Circuit Interrupter) - protected branch
circuit.
8. This unit must be grounded.
CAUTION
1. For general ventilating use only. Do not use to exhaust hazard-
ous or explosive materials and vapors.
2. This product is designed for installation in ceilings up to a
12/12 pitch (45 degree angle). Duct connector must point up.
DO NOT MOUNT THIS PRODUCT IN A WALL.
3. To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off power
unit.
4. Please read specification label on product for further informa-
tion and requirements.
QTREN SERIES
FAN / LIGHT / NIGHT LIGHTS
READ AND SAVE THESE INSTRUCTIONS
CLEANING & MAINTENANCE
For quiet and efficient operation, long life, and attractive appear-
ance - lower or remove grille and vacuum interior of unit with the
dusting brush attachment.
The motor is permanently lubricated and never needs oiling. If the
motor bearings are making excessive or unusual noises, replace
the blower assembly (includes motor and impeller).
OPERATION
The fan, light, and night light can be operated separately. Use a
3-function wall control. Do not use a dimmer switch to operate
the light. See “Connect Wiring” for details. Use of speed controls
other than the NuTone Models 78V and 78W may cause a motor
humming noise.
WARRANTY
Installer: Leave this manual with
the homeowner.
BROAN-NUTONE THREE YEAR LIMITED WARRANTY
Broan-NuTone warrants to the original consumer purchaser of its products
that such products will be free from defects in materials or workmanship
for a period of three years from the date of original purchase. THERE ARE
NO OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT
NOT LIMITED TO, IMPLIED WARRANTIES OF MERCHANTABILITY OR
FITNESS FOR A PARTICULAR PURPOSE.
During this three-year period, Broan-NuTone will, at its option, repair or
replace, without charge, any product or part which is found to be defective
under normal use and service.
THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP
STARTERS, TUBES, HALOGEN AND INCANDESCENT BULBS, FUSES,
FILTERS, DUCTS, ROOF CAPS, WALL CAPS AND OTHER ACCESSO-
RIES FOR DUCTING. This warranty does not cover (a) normal maintenance
and service or (b) any products or parts which have been subject to mis-
use, negligence, accident, improper maintenance or repair (other than by
Broan-NuTone), faulty installation or installation contrary to recommended
installation instructions.
The duration of an implied warranty is limited to the three-year period as
specified for the express warranty. Some states do not allow limitation on how
long an implied warranty lasts, so the above limitation may not apply to you.
BROAN-NUTONE’S OBLIGATION TO REPAIR OR REPLACE, AT BROAN-
NUTONE’S OPTION, SHALL BE THE PURCHASER’S SOLE AND EX-
CLUSIVE REMEDY UNDER THIS WARRANTY. BROAN-NUTONE SHALL
NOT BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL OR SPECIAL
DAMAGES ARISING OUT OF OR IN CONNECTION WITH PRODUCT
USE OR PERFORMANCE. Some states do not allow the exclusion or
limitation of incidental or consequential damages, so the above limitation
may not apply to you.
This warranty gives you specific legal rights, and you may also have other
rights, which vary from state to state. This warranty supersedes all prior
warranties.
To qualify for warranty service, you must (a) notify Broan-NuTone at the
address or telephone number stated below, (b) give the model number and
part identification and (c) describe the nature of any defect in the product or
part. At the time of requesting warranty service, you must present evidence
of the original purchase date.
Broan-NuTone LLC, 926 W. State Street, Hartford, Wisconsin 53027
www.nutone.com 888-336-3948
Register your product online at: www.nutone.com/register
Page 2
MODELS QTREN080FLT • QTREN110FLT
TYPICAL INSTALLATIONS
Housing mounted to I-joists.
Housing mounted anywhere
between trusses using hanger
bars.
PLAN THE INSTALLATION
The unit will operate most quietly and efficiently when located
where the shortest possible duct run and minimum number
of elbows will be needed.
Use a roof cap or wall cap that has a built-in damper to
reduce backdrafts.
Plan to supply the unit with proper line voltage and appropri-
ate power cable.
Housing mounted anywhere be-
tween I-joists using hanger bars.
Housing mounted to joists.
Housing mounted anywhere be-
tween joists using hanger bars.
Housing mounted anywhere be-
tween trusses using hanger bars.
INSTALL HOUSING & DUCT
1a. Mount
housing
to joist or
I-joist.
Use a pliers to
bend housing
TABS out
to 90
0
. Hold
housing in
place so that
the housing
tabs contact
the bottom
of the joist.
The housing
mounts with
four (4) screws
or nails. Screw
or nail housing
to joist through
lowest holes in
each mounting
flange, then
through
highest holes.
SPACER
(use for mounting to I-Joist)
I-JOIST
NOTE: Mounting to I-JOIST (shown) requires use of
SPACERS (included) between the highest hole of
each mounting flange and the I-joist.
OR
Cooking
Equipment
Floor
COOKING AREA
Do not install above or
inside this area.
45
o
45
o
NOT FOR USE IN
A COOKING AREA.
TABS
*Purchase
separately.
INSULATION*
(Place around and
over Fan Housing.)
ROOF CAP*
(with built-in
damper)
FAN
HOUSING
POWER
CABLE*
4-IN. ROUND
DUCT*
4-IN.
ROUND
ELBOWS*
Seal gaps
around
Housing.
Seal duct
joints with
tape.
OR
Keep duct
runs short.
WALL CAP*
(with built-in
damper)
Page 3
MODELS QTREN080FLT • QTREN110FLT
4. Connect electrical wiring.
Run 120 VAC house wiring to installation location. Use
proper UL approved connector to secure house wiring to
wiring plate. Connect wires as shown in wiring diagrams.
CONNECT WIRING
1b. Mount housing anywhere between
trusses, joists, or I-joists using hanger
bars.
Sliding hanger bars are provided to allow for accurate posi-
tioning of housing anywhere between framing. They can be
used on all types of framing (I-joist, standard joist, and truss
construction) and span up to 24”.
Attach the MOUNTING CHANNELS to the housing using
the SCREWS supplied. Make sure TABS face “up” as shown.
Use the set of channel mounting holes (marked “STD”) to
mount the housing flush with the bottom of the drywall. Use
the other set of holes (not marked) to mount the housing
flush with the top of the drywall.
HANGER
BAR (4)
SCREWS (4)
TAB
Extend HANGER BARS to the width of the framing.
Hold ventilator in place with the hanger bar tabs wrapping
around the BOTTOM EDGE OF THE FRAMING.
NAIL ventilator to framing or fasten with screws (not provided)
through HOLES near nails.
*
To ensure a noise-free mount: Secure hanger bars together
with SCREWS or use a pliers to crimp mounting channels
tightly around hanger bars.
HOLE FOR OPTIONAL
SCREW MOUNTING (4)
STD
MOUNTING
CHANNEL (2)
NAIL (4)
BOTTOM EDGE
OF FRAMING
2. Attach
damper/duct
connector.
Snap damper /
duct connector
onto housing.
Make sure con-
nector is flush with
top of housing and
damper flap falls
closed.
3. Install
4-inch round
ductwork.
Connect 4-inch
round ductwork
to damper / duct
connector. Run
ductwork to a roof
cap or wall cap.
Tape all ductwork
connections to
make them se-
cure and air tight.
*
SCREW (2)
Page 4
MODELS QTREN080FLT • QTREN110FLT
SERVICE PARTS
99044457C
Key No. Part No. Description
1 97016466 Housing
2 97016449 Duct Connector-4”
3 98010102 Wiring Plate
4 99170245 Screw, #8-18 X .375
5 97018011 Wire Panel/Harness Assembly
6 97017855 Blower Assembly (QTREN080FLT)
97017856 Blower Assembly (QTREN110FLT)
7 97018274 Grille Assembly (includes key nos. 8, 9 & 10)
8 99140199 Grille Spring (2 reqd)
9 99111401 Lens
10 99271381 Bulb, GU24, 18W Fluorescent (2 req’d)
11 99420665 Thumbscrew, #8-18 x .375
12 97018014 Spacer (2 supplied)
13 QTNHB1 Hanger Bar Kit
Order service parts by “Part No. - not by “Key No.
8. Remove
light
lens.
Carefully
insert
a small
flat-blade
screwdriver
between
grille and
lens. Pry lens
out.
7. Push
grille
against
ceiling.
9. Install light
bulbs.
Fluorescent bulbs
supplied.
Purchase a 4W
incandescent night
light bulb.
Insert bulbs into
their sockets.
Replace lens.
INSTALL GRILLE
5. Finish ceiling.
Install ceiling material. Cut out around housing.
6. Attach
grille to
housing.
Squeeze
grille springs
and insert
them into
tabs on
each side of
housing.
SERVICE NOTE
To remove Blower
Assembly: Unplug
motor. Remove
thumbscrew (11)
from motor plate
flange. Find the
single TAB on
the motor plate
(located next to the
receptacle). Push up
near motor plate tab
while pushing out
on side of housing.
Or insert a straight-
blade screwdriver
into slot in housing
(next to tab) and
twist screwdriver.
Replacement parts can
be ordered on our web-
site. Please visit us at
www.nutone.com
Página 8
MODELOS QTREN080FLT • QTREN110FLT
99044457C
7. Empuje
la rejilla
contra
el cielo
raso.
9. Instale las
bombillas.
Se incluye
las
bombillas
fluorescente.
Compre una bombilla
incandescente para
lámpara de noche (de
4 W).
Inserte las bombillas
en sus receptáculos.
Vuelva a colocar la
lente.
8. Saque la
lente de la
lámpara.
Con cuidado,
inserte un
destornillador
plano pequeño
entre la parilla
y la lente de
lámpara. Haga
palanca con el
destornillador y
saque la lente.
INSTALE LA REJILLA
5. Termine el cielo raso.
Instale el material del cielo raso. Recorte alrededor de la cubierta.
6. Acople
la rejilla
a la
cubierta.
Apriete los
resortes de
la rejilla e
insértelos en
las lengüetas
que se
encuentran a
cada lado de
la cubierta.
PIEZAS DE REPUESTO
Clave n.
o
Pieza n.
o
Descripción
1 97016466
2 97016449
3 98010102
4 99170245
5 97018011
6 97017855
97017856
7 97018274
8 99140199
9 99111401
10 99271381
11 99420665
12 97018014
13 QTNHB1
Al hacer el pedido de una pieza de servicio se debe especificar el número de la
pieza (no el número de la clave).
NOTA DE SERVICIO
Para desmontar el
conjunto del ventilador:
Desenchufe el motor.
Saque el tornillo de
mariposa (11) de la
brida de la placa del
motor. Localice la
LENGÜETA única de
la placa del motor (se
encuentra junto al
receptáculo). Empuje
hacia arriba cerca de la
lengüeta de la placa del
motor al mismo tiempo
que empuja hacia afuera
el costado de la cubi-
erta. O bien, introduzca
un destornillador de
punta recta en la ranura
de la cubierta (junto a la
lengüeta) y haga girar el
destornillador.
Las piezas de recambio se
pueden ahora pedir en nuestro
Web site. Visítenos por favor
en www.nutone.com
Cubierta
Conector de conductor, 4 pulg.
Placa de cableado
Tornillo n.
o
8-18 x 0.375
Conjunto del panel de cableado/arnés
Conjunto del ventilador (QTREN080FLT)
Conjunto del ventilador (QTREN110FLT)
Conjunto de la rejilla
(incluyen las piezas de las claves n.
o
8, 9 y 10)
Resorte de la rejilla (se requieren 2)
Lente
Bombilla fluorescente, GU24, 18 W (se requieren 2)
Tornillo de mariposa n.
o
8-18 x 0.375
Separador (provisto 2)
Juego de barra de suspención
/