Daikin J Series Engineeiring Data

Category
Split-system air conditioners
Type
Engineeiring Data
EDUS041016
J-Series
- Cooling Only / Heat Pump -
SEER 13 Models
EDUS041016
Room Air Conditioners J-Series 1
Split-System
Room Air Conditioners
J-Series
1. Power Supply..........................................................................................3
2. Functions ................................................................................................4
3. Specifications..........................................................................................5
3.1 Cooling Only.............................................................................................5
3.2 Heat Pump ...............................................................................................6
4. Dimensions .............................................................................................7
4.1 Indoor Units..............................................................................................7
4.2 Outdoor Units...........................................................................................8
5. Wiring Diagrams .....................................................................................9
5.1 Indoor Units..............................................................................................9
5.2 Outdoor Units...........................................................................................9
6. Piping Diagrams....................................................................................10
6.1 Indoor Units............................................................................................10
6.2 Outdoor Units.........................................................................................11
7. Capacity Tables ....................................................................................12
7.1 Cooling Only...........................................................................................12
7.2 Heat Pump .............................................................................................14
7.3 Capacity correction factor by the length of refrigerant piping
(Reference) 18
8. Operation Limit......................................................................................19
9. Sound Level ..........................................................................................20
9.1 Measuring Location................................................................................20
9.2 Octave Band Level.................................................................................21
10.Electric Characteristics .........................................................................23
11.Installation Manual ................................................................................24
11.1 Indoor Units - Safety Considerions ........................................................24
11.2 Indoor Unit Installation Instructions ........................................................26
11.3 Outdoor Units - Safety Considerions......................................................37
11.4 Outdoor Units Installation Instructions ...................................................39
12.Operation Manual .................................................................................49
The Single Split Duct-Free System
Cooling Only
FTKN09JEVJU
FTKN12JEVJU
RKN09JEVJU
RKN12JEVJU
Heat Pump
FTXN09JEVJU
FTXN12JEVJU
RXN09JEVJU
RXN12JEVJU
EDUS041016
2 Room Air Conditioners J-Series
12.1 Safety Considerations ............................................................................49
12.2 Operation Instructions ............................................................................52
13.Optional Accessories ............................................................................77
13.1 Option List ..............................................................................................77
13.2 <BRC944B2> Wired Remote Controller.................................................78
13.3 <KRP980B1> Interface Adaptor for Wired Remote Controller ...............92
13.4 <KPW937A4> Air Direction Adjustment Grille........................................96
EDUS041016 Power Supply
Room Air Conditioners J-Series 3
1. Power Supply
Note:
Power Supply Intake ; Outdoor Unit
Indoor Units Outdoor Units Power Supply
The Single Split
Duct-Free System
FTKN09JEVJU RKN09JEVJU
1
, 208-230V, 60Hz
FTKN12JEVJU RKN12JEVJU
FTXN09JEVJU RXN09JEVJU
FTXN12JEVJU RXN12JEVJU
Functions EDUS041016
4 Room Air Conditioners J-Series
2. Functions
Category Functions
FTKN09/12JEVJU
RKN09/12JEVJU
FTXN09/12JEVJU
RXN09/12JEVJU
Category Functions
FTKN09/12JEVJU
RKN09/12JEVJU
FTXN09/12JEVJU
RXN09/12JEVJU
Basic
Function
Inverter (with Inverter Power Control) Health &
Clean
Air-Purifying Filter
Operation Limit for Cooling (°FDB)
50~
114.8
50~
114.8
Photocatalytic Deodorizing Filter
Operation Limit for Heating (°FWB) 5~68
Air-Purifying Filter with Photocatalytic
Deodorizing Function
——
PAM Control 
Titanium Apatite Photocatalytic
Air-Purifying Filter

Compressor Oval Scroll Compressor Air Filter (Prefilter) 
Swing Compressor  Wipe-clean Flat Panel 
Rotary Compressor Washable Grille
Reluctance DC Motor  Filter Cleaning Indicator
Comfortable
Airflow
Power-Airflow Louver (Horizontal Blade)
 Good-Sleep Cooling Operation
Power-Airflow Dual Louvers Timer 24-Hour ON/OFF Timer 
Power-Airflow Diffuser NIGHT SET Mode 
Wide-Angle Fins (Vertical Blades) Worry Free
“Reliability &
Durability”
Auto-Restart (after Power Failure) 
Vertical Auto-Swing (Up and Down)  Self-Diagnosis (Digital, LED) Display 
Horizontal Auto-Swing (Right and Left) Wiring Error Check
3-D Airflow
Anti-Corrosion Treatment of Outdoor
Heat Exchanger

COMFORT AIRFLOW Operation 
Flexibility Multi-Split / Split Type Compatible
Indoor Unit
——
Comfort
Control
Auto Fan Speed  Flexible Voltage Correspondence
Indoor Unit Quiet Operation  High Ceiling Application
NIGHT QUIET Mode (Automatic) Chargeless 32.8ft 32.8ft
Outdoor Unit Quiet Operation (Manual) Either Side Drain (Right or Left) 
INTELLIGENT EYE Operation Power Selection
Quick Warming Function
Remote
Control
5-Rooms Centralized Controller
(Option)
——
Hot-Start Function
Remote Control Adaptor
(Normal Open-Pulse Contact) (Option)
——
Automatic Defrosting
Remote Control Adaptor
(Normal Open Contact) (Option)
——
Operation Automatic Operation DIII-NET Compatible (Adaptor) (Option)
Program Dry Function Remote
Controller
Wireless 
Fan Only  Wired 
Lifestyle
Convenience
New POWERFUL Operation
(Non-Inverter)
——
Inverter POWERFUL Operation 
Priority-Room Setting
COOL / HEAT Mode Lock
HOME LEAVE Operation
ECONO Operation 
Indoor Unit ON/OFF Button 
Signal Receiving Sign 
Temperature Display
Another Room Operation
Note: : Holding Functions
— : No Functions
EDUS041016 Specifications
Room Air Conditioners J-Series 5
3. Specifications
3.1 Cooling Only
The data are based on the conditions shown in the table below.
Models
60Hz 208-230V
Indoor Units FTKN09JEVJU FTKN12JEVJU
Outdoor Units RKN09JEVJU RKN12JEVJU
Capacity
Rated (Min.~Max.)
kW 2.49 (1.30~2.78) 2.93 (1.3~3.52)
Btu/h 8,500 (4,400~9,500) 10,000 (4,400~12,000)
kcal/h 2,140 (1,120~2,390) 2,520 (1,120~3,030)
Running Current (Rated) A 4.6-4.1 4.8-4.4
Power Consumption Rated
(Min.~Max.)
W 795 (330~890) 945 (330~1,310)
Power Factor % 83.1-84.3 94.7-93.4
COP (Rated) (Min.~Max.) W/W 3.13 (3.94~3.12) 3.10 (3.94~2.69)
EER (Rated) (Min.~Max.)
Btu/h·W
10.69 (13.33~10.67) 10.58 (13.33~9.16)
Piping
Connections
Liquid inch 1/4 1/4
Gas inch 3/8 3/8
Drain inch 5/8 5/8
Heat Insulation Both Liquid and Gas Pipes Both Liquid and Gas Pipes
Max. Interunit Piping Length feet 49.2 49.2
Max. Interunit Height Difference feet 39.3 39.3
Chargeless feet 32.8 32.8
Amount of Additional Charge of Refrigerant oz/ft 0.22 0.22
Indoor Units FTKN09JEVJU FTKN12JEVJU
Front Panel Color White White
Airflow Rate
m³/min (cfm)
H 9.2 (325) 9.3 (328)
M 7.4 (261) 7.7 (272)
L 5.3 (187) 5.6 (198)
SL 4.0 (141) 4.4 (155)
Fan
Type Cross Flow Fan Cross Flow Fan
Motor Output W 16 16
Speed Steps 5 Steps, Quiet, Auto 5 Steps, Quiet, Auto
Air Direction Control Right, Left, Horizontal, Downward Right, Left, Horizontal, Downward
Air Filter Removable / Washable / Mildew Proof Removable / Washable / Mildew Proof
Running Current (Rated) A 0.20-0.18 0.20-0.18
Power Consumption (Rated) W 40 40
Power Factor % 96.2-96.6 96.2-96.6
Temperature Control Microcomputer Control Microcomputer Control
Dimensions (H×W×D) inch 11-9/64×30-5/16×7-51/64 11-9/64×30-5/16×7-51/64
Packaged Dimensions (H×W×D) inch 10-17/64×33-7/32×13-15/32 10-17/64×33-7/32×13-15/32
Weight Lbs 16 16
Gross Weight Lbs 24 24
Operation Sound H/M/L/SL dBA 40 / 33 / 26 / 22 41 / 34 / 27 / 23
Sound Power dBA 56 57
Outdoor Units RKN09JEVJU RKN12JEVJU
Casing Color Ivory White Ivory White
Compressor
Type Hermetically Sealed Swing Type Hermetically Sealed Swing Type
Model 1YC23AEXD 1YC23AEXD
Motor Output W 750 750
Refrigerant Oil
Type FVC50K FVC50K
Charge oz 12.5 12.5
Refrigerant
Type R-410A R-410A
Charge Lbs 2.20 2.20
Airflow Rate
m³/min (cfm)
H
29.0 (1,024) 29.0 (1,024)
Fan
Type Propeller Propeller
Motor Output W 59 59
Running Current (Rated) A 4.40-3.92 4.60-4.22
Power Consumption (Rated) W 755 905
Power Factor % 82.5-83.7 94.6-93.2
Starting Current A 4.6 4.8
Dimensions (H×W×D) inch 21-21/32×25-29/32×10-13/16 21-21/32×25-29/32×10-13/16
Packaged Dimensions (H×W×D) inch 23-5/16×30-23/64×13-45/64 23-5/16×30-23/64×13-45/64
Weight Lbs 66 66
Gross Weight Lbs 76 76
Operation Sound dBA 49 50
Sound Power dBA 63 64
Drawing No. 3D066714 3D066715
Cooling Piping Length
Indoor ; 80°FDB/67°FWB
Outdoor ; 95°FDB/75°FWB
25 ft
Conversion Formulae
kcal/h=kW×860
Btu/h=kW×3412
cfm=m³/min×35.3
Specifications EDUS041016
6 Room Air Conditioners J-Series
3.2 Heat Pump
The data are based on the conditions shown in the table below.
Models
60Hz 208-230V
Indoor Units FTXN09JEVJU FTXN12JEVJU
Outdoor Units
RXN09JEVJU RXN12JEVJU
Cooling Heating Cooling Heating
Capacity
Rated (Min.~Max.)
kW 2.49 (1.30~2.78) 2.93 (1.3~3.4) 2.93 (1.3~3.52) 3.52 (1.3~4.8)
Btu/h 8,500 (4,400~9,500) 10,000 (4,400~11,600) 10,000 (4,400~12,000) 12,000 (4,400~16,400)
kcal/h 2,140 (1,120~2,390) 2,520 (1,120~2,920) 2,520 (1,120~3,030) 3,030 (1,120~4,130)
Running Current (Rated) A 4.6-4.1 4.6-4.2 4.8-4.4 5.4-4.9
Power Consumption Rated
(Min.~Max.)
W 795 (330~890) 865 (320~930) 945 (330~1,310) 1,050 (320~1,650)
Power Factor % 83.1-84.3 90.4-89.5 94.7-93.4 93.5-93.2
COP (Rated) (Min.~Max.) W/W 3.13 (3.94~3.12) 3.39 (4.06~3.66) 3.10 (3.94~2.69) 3.35 (4.06~2.91)
EER (Rated) (Min.~Max.)
Btu/h·W
10.69 (13.33~10.67) 11.56 (13.75~12.47) 10.58 (13.33~9.16) 11.43 (13.75~9.94)
Piping
Connections
Liquid inch 1/4 1/4
Gas inch 3/8 3/8
Drain inch 5/8 5/8
Heat Insulation Both Liquid and Gas Pipes Both Liquid and Gas Pipes
Max. Interunit Piping Length feet 49.2 49.2
Max. Interunit Height Difference feet 39.3 39.3
Chargeless feet 32.8 32.8
Amount of Additional Charge of
Refrigerant
oz/ft 0.22 0.22
Indoor Units FTXN09JEVJU FTXN12JEVJU
Front Panel Color White White
Airflow Rate m³/min (cfm)
H 9.2 (325) 9.7 (342) 9.3 (328) 10.1 (357)
M 7.4 (261) 8.1 (286) 7.7 (272) 8.4 (297)
L 5.3 (187) 6.4 (226) 5.6 (198) 6.7 (237)
SL 4.0 (141) 5.6 (198) 4.4 (155) 5.9 (208)
Fan
Type Cross Flow Fan Cross Flow Fan
Motor Output W 16 16
Speed Steps 5 Steps, Quiet, Auto 5 Steps, Quiet, Auto
Air Direction Control Right, Left, Horizontal, Downward Right, Left, Horizontal, Downward
Air Filter Removable / Washable / Mildew Proof Removable / Washable / Mildew Proof
Running Current (Rated) A 0.20-0.18 0.20-0.18
Power Consumption (Rated) W 40 40
Power Factor % 96.2-96.6 96.2-96.6
Temperature Control Microcomputer Control Microcomputer Control
Dimensions (H×W×D) inch 11-9/64×30-5/16×7-51/64 11-9/64×30-5/16×7-51/64
Packaged Dimensions (H×W×D) inch 10-17/64×33-7/32×13-15/32 10-17/64×33-7/32×13-15/32
Weight Lbs 16 16
Gross Weight Lbs 24 24
Operation Sound H/M/L/SL dBA 40 / 33 / 26 / 22 40 / 34 / 28 / 25 41 / 34 / 27 / 23 41 / 35 / 29 / 26
Sound Power dBA 56 57
Outdoor Units RXN09JEVJU RXN12JEVJU
Casing Color Ivory White Ivory White
Compressor
Type Hermetically Sealed Swing Type Hermetically Sealed Swing Type
Model 1YC23AEXD 1YC23AEXD
Motor Output W 750 750
Refrigerant Oil
Type FVC50K FVC50K
Charge oz 12.5 12.5
Refrigerant
Type R-410A R-410A
Charge Lbs 2.20 2.20
Airflow Rate m³/min (cfm) H 29.0 (1,024) 28.1 (992) 29.0 (1,024) 28.1 (992)
Fan
Type Propeller Propeller
Motor Output W 59 59
Running Current (Rated) A 4.40-3.92 4.40-4.02 4.60-4.22 5.20-4.72
Power Consumption (Rated) W 755 825 905 1,010
Power Factor % 82.5-83.7 90.1-89.2 94.6-93.2 93.4-93.0
Starting Current A 4.6 5.4
Dimensions (H×W×D) inch 21-21/32×25-29/32×10-13/16 21-21/32×25-29/32×10-13/16
Packaged Dimensions (H×W×D) inch 23-5/16×30-23/64×13-45/64 23-5/16×30-23/64×13-45/64
Weight Lbs 68 68
Gross Weight Lbs 78 78
Operation Sound dBA 49 50 50 51
Sound Power dBA 63 64 64 65
Drawing No. 3D066712 3D066713
Cooling Heating Piping Length
Indoor ; 80°FDB/67°FWB
Outdoor ; 95°FDB/75°FWB
Indoor ; 70°FDB/60°FWB
Outdoor ; 47°FDB/43°FWB
25 ft
Conversion Formulae
kcal/h=kW×860
Btu/h=kW×3412
cfm=m³/min×35.3
EDUS041016 Dimensions
Room Air Conditioners J-Series 7
4. Dimensions
4.1 Indoor Units
FTKN09/12JEVJU
FTXN09/12JEVJU
AIRFLOW (INDOOR)
THE MARK () SHOWS PIPING DIRECTION
REAR
30-5/16(770mm)
RIGHTLEFT
1-3/16(30mm)MIN.
INCLUDING
MOUNTING PLATE
(SPACE FOR
PERFORMANCE)
7-7/8(200mm)
1-15/16(50mm)MIN.
1-15/16(50mm)MIN.
7-51/64(198mm)
(SPACE FOR
(SPACE FOR
FRONT PANEL FIXING SCREWS
REQUIRED SPACE
MAINTENANCE)
MAINTENANCE)
(INSIDE)
GENERAL RATING
NAME PLATE
SIGNAL RECEIVER
TERMINAL BLOCK
OPERATION LAMP
WITH EARTH
TIMER LAMP
TERMINAL
F
F
O
O
N
INDOOR UNIT ON/OFF SWITCH
(INSIDE)
11-9/64(283mm)
BOTTOM
ROOM TEMP. THERMISTOR
FLAPS
GAS PIPE
φ
3/8(
φ
9.5mm) CuT
(INSIDE)
DRAIN HOSE
(THE LENGTH OF PIPE OUTSIDE
(CONNECTING PART
THE UNIT : ABOUT 15-23/64(390mm))
I.D.
F
F
O
O
N
LIQUID PIPE
φ
1/4(
φ
6.4mm) CuT
O.D.
φ
9/16(
φ
14mm)
φ
5/8(
φ
16mm)
(THE LENGTH OF PIPE OUTSIDE
THE HOSE LENGTH OF OUTSIDE
THE UNIT : ABOUT 17-21/64(440mm))
THE UNIT IS ABOUT 17-23/32(450mm))
30-5/16(770mm)
MODEL NAME
SIGNAL TRANSMITTER
15/64(6mm)
21-39/64(549mm)
5/8(16mm)
PLATE
3-31/32(101mm)
11/16(18mm)2-5/16(58mm)
BLADE ANGLE
6-49/64(172mm)
UP/DOWN (AUTOMATIC)
11-9/64(283mm)
1-5/8(41.3mm)
COOLING DRY FAN
45˚ 45˚45˚
2-9/64(54.5mm) 2-1/8(54mm)
1-5/8(41.3mm)
7-3/8(187mm)
WALL HOLE FOR EMBEDDED PIPING
RIGHT/LEFT (MANUAL)
φ
2-9/16(
φ
65mm) HOLE
WALL HOLE
φ
2-9/16(
φ
65mm) HOLE
STANDARD LOCATIONS OF WALL HOLES
WIRELESS REMOTE CONTROLLER
45˚
45˚
(ARC452A14)
3D065952B
AIRFLOW (INDOOR)
THE MARK () SHOWS PIPING DIRECTION
REAR
30-5/16(770mm)
RIGHT
LEFT
1-3/16(30mm)MIN.
INCLUDING
MOUNTING PLATE
(SPACE FOR
PERFORMANCE)
7-7/8(200mm)
1-15/16(50mm)MIN.
1-15/16(50mm)MIN.
7-51/64(198mm)
(SPACE FOR
(SPACE FOR
FRONT PANEL FIXING SCREWS
REQUIRED SPACE
MAINTENANCE)
MAINTENANCE)
(INSIDE)
GENERAL RATING
NAME PLATE
SIGNAL RECEIVER
TERMINAL BLOCK
OPERATION LAMP
WITH EARTH
TIMER LAMP
TERMINAL
F
F
O
O
N
INDOOR UNIT ON/OFF SWITCH
(INSIDE)
11-9/64(283mm)
BOTTOM
ROOM TEMP. THERMISTOR
FLAPS
GAS PIPE
φ
3/8(
φ
9.5mm) CuT
(INSIDE)
DRAIN HOSE
(THE LENGTH OF PIPE OUTSIDE
(CONNECTING PART
THE UNIT : ABOUT 15-23/64(390mm))
I.D.
F
F
O
O
N
LIQUID PIPE
φ
1/4(
φ
6.4mm) CuT
O.D.
φ
9/16(
φ
14mm)
φ
5/8(
φ
16mm)
(THE LENGTH OF PIPE OUTSIDE
THE HOSE LENGTH OF OUTSIDE
THE UNIT : ABOUT 17-21/64(440mm))
THE UNIT IS ABOUT 17-23/32(450mm))
30-5/16(770mm)
MODEL NAME
SIGNAL TRANSMITTER
15/64(6mm)
21-39/64(549mm)
5/8(16mm)
PLATE
3-31/32(101mm)
11/16(18mm)2-5/16(58mm)
BLADE ANGLE
6-49/64(172mm)
UP/DOWN (AUTOMATIC)
11-9/64(283mm)
1-5/8(41.3mm)
COOLING HEATING DRY
15˚
45˚
45˚
2-9/64(54.5mm) 2-1/8(54mm)
45˚
1-5/8(41.3mm)
7-3/8(187mm)
FAN
WALL HOLE FOR EMBEDDED PIPING
RIGHT/LEFT (MANUAL)
φ
2-9/16(
φ
65mm) HOLE
WALL HOLE
φ
2-9/16(
φ
65mm) HOLE
STANDARD LOCATIONS OF WALL HOLES
WIRELESS REMOTE CONTROLLER
45˚
45˚
45˚
(ARC452A12)
3D065951B
Dimensions EDUS041016
8 Room Air Conditioners J-Series
4.2 Outdoor Units
RKN09/12JEVJU, RXN09/12JEVJU
DRAIN OUTLET
4-HOLES FOR ANCHOR BOLTS
(I.D5/8 [
φ
15.9] HOSE FOR CONNECTION
(M8 OR M10)
WITH DRAIN JOINT [ OPTION ] )
18-1/2(470) 3-25/32(96)
1-9/16(40)
7/16(11)
14-29/32(379)
11-11/16(297)
OUTDOOR AIR THERMISTOR
BRAND NAME LABEL
MANUFACTURE'S LABEL
HANDLE
5/16(8)
5/16(8) 1-31/32(50)
10-13/16(275)
15/32(12) 25-29/32(658)
LIQUID
STOP VALVE
1/4(φ6.4)CuT
SERVICE
PORT
21-21/32(550)
6-5/8(168)
6-3/32(155)
WALL HEIGHT ON AIR OUTLET SIDE
MINIMUM SPACE FOR AIR PASSAGE
4-1/4(108)
=LESS THAN 47-3/16(1200)
IN CASE OF REMOVING
GAS ST
OP VALVE
STOP VALVE
3/8(
φ
9.5)CuT
5-7/8(150)
5-7/8(150)
1-15/16(50)1-15/16(50)1-15/16(50)
3-15/16(100)
1-15/16(50)
UNIT = INCH(mm)
3-15/16(100)
11-13/16(300)
3D065923A
EDUS041016 Wiring Diagrams
Room Air Conditioners J-Series 9
5. Wiring Diagrams
5.1 Indoor Units
FTKN09/12JEVJU, FTXN09/12JEVJU
5.2 Outdoor Units
RKN09/12JEVJU, RXN09/12JEVJU
PCB 2
PCB 1
S26S27
FIELD WIRING.
BLK
19
BLK
TRANSMISSION
BLK
GRN/YLW
LED1 H1P
CIRCUIT
BLK
BLK
3
FG
LED2 H2P
BLK
GRN
BLK
2
RECTIFIER
H3
BLK
+
RED
3
1
BLK
OUTDOOR
9
MR10
1
V1
H2
WHT
2
H1
CAUTION
BLK
S1W
1
NOTE THAT OPERATION WILL
F1U
RESTART AUTOMATICALLY IF
X1M
3.15A
THE MAIN POWER SUPPLY IS
+
R1T
TURNED OFF AND THEN BACK
IPM200
SIGNAL
ON AGAIN.
RECEIVER
11125 10S40312916
S32
S200
S6
INDOOR
BLK BLK
BLK
BLK
BLK
BLK
BLK
BLK
BLK
BLK
BLKBLK
YLW
BLKBLKBLK
WIRELESS
BLU
BLK
RED
WHT
ORG
FG
REMOTE
F1U
1416
S601S602
CONTROLLER
H1~H3
MM
H1P~H2P
M1S
M1F
M1F
R2T
M1S
PCB1~PCB3
R1T, R2T
NOTE)
S6~S602
S21
S1W
1.PCB3 SHOWS THE CASE OF
X1M
OPTION CONNECTION.
PCB 3
OPTION
: FRAME GROUND
: FUSE
: HARNESS
: PILOT LAMP
: FAN MOTOR
: SWING MOTOR
: PRINTED CIRCUIT BOARD
: THERMISTOR
: CONNECTOR
: OPERATION SWITCH
: TERMINAL STRIP
: PROTECTIVE EARTH
3D065939A
Piping Diagrams EDUS041016
10 Room Air Conditioners J-Series
6. Piping Diagrams
6.1 Indoor Units
FTKN09/12JEVJU FTXN09/12JEVJU
INDOOR UNIT
HEAT EXCHANGER
9/32CuT
3/16CuT
9/32CuT
THERMISTOR
ON HEAT EXCH.
9/32CuT
9/32CuT
CROSS FLOW FAN
FIELD PIPING
(1/4CuT)
M
FAN MOTOR
3/8CuT
FIELD PIPING
(3/8CuT)
REFRIGERANT FLOW
COOLING
4D066315
INDOOR UNIT
HEAT EXCHANGER
9/32CuT
3/16CuT
9/32CuT
THERMISTOR
ON HEAT EXCH.
9/32CuT
9/32CuT
CROSS FLOW FAN
FIELD PIPING
(1/4CuT)
M
FAN MOTOR
3/8CuT
FIELD PIPING
(3/8CuT)
REFRIGERANT FLOW
COOLING
HEATING
4D066211
EDUS041016 Piping Diagrams
Room Air Conditioners J-Series 11
6.2 Outdoor Units
RKN09/12JEVJU
RXN09/12JEVJU
OUTDOOR UNIT
HEAT EXCHANGER
9/32CuT
9/32CuT
3/8CuT
CAPILLARY
TUBE
3/16CuT
1/4CuT
1/4CuT
3/16CuT
THERMSTOR
MUFFLER
HEAT EXCHANGER
FAN
WITH
FILTER
MOTOR
M
PROPELLER FAN
1/4CuT
3/8CuT
STRAINER
FIELD PIPING
3/16CuT
(1/4CuT)
LIQUID STOP
3/8CuT
VALVE
1/4CuT
REFRIGERANT FLOW
MUFFLER MUFFLER
FIELD PIPING
3/8CuT
DISCHARGE PIPE
COOLING
COMPRESSOR
THERMISTOR
(3/8CuT)
GAS STOP
VALVE
ACCUMULATOR
3D066384
OUTDOOR UNIT
OUTDOOR TEMPERATURE
HEAT EXCHANGER
9/32CuT
THERMISTOR
9/32CuT
3/8CuT
CAPILLARY
CHECK VALVE
TUBE 1
3/16CuT
1/4CuT1/4CuT
3/16CuT
MUFFLER
THERMISTOR
WITH
HEAT EXCHANGER
FAN
CAPILLARY
FILTER
MOTOR
TUBE 2
M
PROPELLER FAN
1/4CuT
3/8CuT
3/8CuT
FOUR WAY
VALVE
ON: HEATING
FIELD PIPING
3/16CuT
(1/4CuT)
LIQUID STOP
3/8CuT
VALVE
1/4CuT
REFRIGERANT FLOW
MUFFLER MUFFLER
FIELD PIPING
3/8CuT
DISCHARGE PIPE
COOLING
COMPRESSOR
THERMISTOR
(3/8CuT)
GAS STOP
HEATING
VALVE
ACCUMULATOR
3D066383
Capacity Tables EDUS041016
12 Room Air Conditioners J-Series
7. Capacity Tables
7.1 Cooling Only
FTKN09JEVJU + RKN09JEVJU
(60Hz 208/230V)
3D066771
AFR 9.2
BF 0.23
Temp: Celsius / TC, SHC, PI: kW
INDOOR OUTDOOR TEMPERATURE (°CDB)
EWB EDB 20.0 25.0 30.0 32.0 35.0 40.0
°C °C TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI
14.0 20.0 2.32 1.85 0.58 2.32 1.85 0.65 2.32 1.85 0.73 2.27 1.83 0.75 2.20 1.80 0.79 2.09 1.74 0.84
16.0 22.0 2.67 1.93 0.61 2.55 1.88 0.67 2.43 1.83 0.73 2.39 1.81 0.75 2.32 1.77 0.79 2.20 1.72 0.85
18.0 25.0 2.78 2.03 0.62 2.66 1.99 0.68 2.55 1.94 0.73 2.50 1.92 0.76 2.43 1.89 0.79 2.32 1.84 0.85
19.4 26.7 2.84 2.16 0.62 2.72 2.11 0.68 2.61 2.06 0.74 2.56 2.04 0.76
2.49 2.01 0.80 2.37 1.97 0.85
22.0 30.0 3.01 2.08 0.62 2.89 2.04 0.68 2.78 2.00 0.74 2.73 1.98 0.77 2.66 1.96 0.80 2.55 1.92 0.86
24.0 32.0 3.12 2.03 0.63 3.01 1.99 0.69 2.89 1.96 0.75 2.85 1.94 0.77 2.78 1.92 0.80 2.66 1.88 0.86
Temp: Fahrenheit / TC, SHC: kBtu / PI: kW
INDOOR OUTDOOR TEMPERATURE (°FDB)
EWB EDB 68.0 77.0 86.0 90.0 95.0 104.0
°F °F TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI
57.2 68.0 7.92 5.43 0.58 7.92 5.43 0.65 7.92 5.43 0.73 7.76 5.30 0.75 7.52 5.11 0.79 7.13 4.80 0.79
60.8 71.6 9.10 6.05 0.61 8.70 5.71 0.67 8.31 5.39 0.73 8.15 5.27 0.75 7.91 5.08 0.79 7.52 4.79 0.80
64.4 77.0 9.49 6.09 0.62 9.10 5.78 0.68 8.70 5.47 0.73 8.54 5.35 0.76 8.30 5.17 0.79 7.91 4.89 0.80
67.0 80.0 9.69 6.18 0.62 9.29 5.86 0.68 8.90 5.56 0.74 8.74 5.45 0.76
8.50 5.27 0.80 8.10 5.00 0.80
71.6 86.0 10.27 5.93 0.62 9.88 5.64 0.68 9.48 5.36 0.74 9.32 5.26 0.77 9.09 5.10 0.80 8.69 4.84 0.81
75.289.610.675.720.6310.275.450.699.875.190.759.725.090.779.484.940.809.084.700.81
Symbols Note:
AFR : Airflow rate (m
3
/min.) 1. Ratings shown are net capacities which include a deduction for indoor fan
motor heat.
2. shows nominal (rated) capacities and power input.
3. TC, PI and SHC must be calculated by interpolation using the figures in
the above tables. (Figures out of the tables should not be used for
calculation.)
4. About SHC which are not mentioned on the table, please calculate them
with around values in direct proportion.
5. Capacities are based on the following conditions.
Corresponding refrigerant piping length : 25 ft
Level difference : 0 ft
6. Airflow rate (AFR) and Bypass factor (BF) are tabulated above table.
BF : Bypass factor
EWB : Entering wet bulb temp. (°C) / (°F)
EDB : Entering dry bulb temp. (°C) / (°F)
TC : Total capacity (kW) / (kBtu/h)
SHC : Sensible heating capacity (kW) / (kBtu/h)
PI : Power input (kW)
EDUS041016 Capacity Tables
Room Air Conditioners J-Series 13
FTKN12JEVJU + RKN12JEVJU
(60Hz 208/230V)
3D066772
AFR 9.3
BF 0.26
Temp: Celsius / TC, SHC, PI: kW
INDOOR OUTDOOR TEMPERATURE (°CDB)
EWB EDB 20.0 25.0 30.0 32.0 35.0 40.0
°C °C TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI
14.0 20.0 2.28 1.82 0.63 2.28 1.82 0.71 2.28 1.82 0.80 2.28 1.82 0.84 2.28 1.82 0.89 2.28 1.82 0.98
16.0 22.0 3.05 2.10 0.72 3.00 2.08 0.80 2.86 2.01 0.87 2.81 1.99 0.90 2.73 1.95 0.94 2.59 1.89 1.01
18.0 25.0 3.27 2.24 0.73 3.14 2.17 0.80 3.00 2.11 0.87 2.94 2.09 0.90 2.86 2.06 0.94 2.73 2.00 1.01
19.4 26.7 3.34 2.35 0.74 3.20 2.29 0.81 3.07 2.23 0.88 3.01 2.21 0.90
2.93 2.18 0.95 2.79 2.12 1.01
22.0 30.0 3.54 2.26 0.74 3.41 2.21 0.81 3.27 2.16 0.88 3.21 2.14 0.91 3.13 2.11 0.95 3.00 2.06 1.02
24.0 32.0 3.68 2.20 0.75 3.54 2.16 0.82 3.40 2.11 0.89 3.35 2.09 0.91 3.27 2.06 0.96 3.13 2.02 1.03
Temp: Fahrenheit / TC, SHC: kBtu / PI: kW
INDOOR OUTDOOR TEMPERATURE (°FDB)
EWB EDB 68.0 77.0 86.0 90.0 95.0 104.0
°F °F TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI
57.2 68.0 7.78 5.33 0.63 7.78 5.33 0.71 7.78 5.33 0.80 7.78 5.33 0.84 7.78 5.33 0.89 7.78 5.33 0.92
60.871.610.417.290.7210.247.130.809.776.690.879.596.510.909.316.260.948.845.860.95
64.4 77.0 11.17 7.64 0.73 10.70 7.20 0.80 10.24 6.77 0.87 10.05 6.60 0.90 9.77 6.36 0.94 9.30 5.97 0.95
67.0 80.0 11.40 7.72 0.74 10.93 7.28 0.81 10.47 6.86 0.88 10.28 6.70 0.90
10.00 6.46 0.95 9.53 6.08 0.95
71.6 86.0 12.09 7.45 0.74 11.62 7.04 0.81 11.16 6.65 0.88 10.97 6.50 0.91 10.69 6.28 0.95 10.23 5.92 0.96
75.2 89.6 12.55 7.20 0.75 12.08 6.82 0.82 11.62 6.45 0.89 11.43 6.31 0.91 11.15 6.10 0.96 10.69 5.76 0.96
Symbols Note:
AFR : Airflow rate (m
3
/min.) 1. Ratings shown are net capacities which include a deduction for indoor fan
motor heat.
2. shows nominal (rated) capacities and power input.
3. TC, PI and SHC must be calculated by interpolation using the figures in
the above tables. (Figures out of the tables should not be used for
calculation.)
4. About SHC which are not mentioned on the table, please calculate them
with around values in direct proportion.
5. Capacities are based on the following conditions.
Corresponding refrigerant piping length : 25 ft
Level difference : 0 ft
6. Airflow rate (AFR) and Bypass factor (BF) are tabulated above table.
BF : Bypass factor
EWB : Entering wet bulb temp. (°C) / (°F)
EDB : Entering dry bulb temp. (°C) / (°F)
TC : Total capacity (kW) / (kBtu/h)
SHC : Sensible heating capacity (kW) / (kBtu/h)
PI : Power input (kW)
Capacity Tables EDUS041016
14 Room Air Conditioners J-Series
7.2 Heat Pump
FTXN09JEVJU + RXN09JEVJU
(60Hz 208/230V)
Cooling
Heating
AFR 9.2
BF 0.23
Temp: Celsius / TC, SHC, PI: kW
INDOOR OUTDOOR TEMPERATURE (°CDB)
EWB EDB 20.0 25.0 30.0 32.0 35.0 40.0
°C °C TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI
14.0 20.0 2.32 1.85 0.58 2.32 1.85 0.65 2.32 1.85 0.73 2.27 1.83 0.75 2.20 1.80 0.79 2.09 1.74 0.84
16.0 22.0 2.67 1.93 0.61 2.55 1.88 0.67 2.43 1.83 0.73 2.39 1.81 0.75 2.32 1.77 0.79 2.20 1.72 0.85
18.0 25.0 2.78 2.03 0.62 2.66 1.99 0.68 2.55 1.94 0.73 2.50 1.92 0.76 2.43 1.89 0.79 2.32 1.84 0.85
19.4 26.7 2.84 2.16 0.62 2.72 2.11 0.68 2.61 2.06 0.74 2.56 2.04 0.76
2.49 2.01 0.80 2.37 1.97 0.85
22.0 30.0 3.01 2.08 0.62 2.89 2.04 0.68 2.78 2.00 0.74 2.73 1.98 0.77 2.66 1.96 0.80 2.55 1.92 0.86
24.0 32.0 3.12 2.03 0.63 3.01 1.99 0.69 2.89 1.96 0.75 2.85 1.94 0.77 2.78 1.92 0.80 2.66 1.88 0.86
Temp: Fahrenheit / TC, SHC: kBtu / PI: kW
INDOOR OUTDOOR TEMPERATURE (°FDB)
EWB EDB 68.0 77.0 86.0 90.0 95.0 104.0
°F °F TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI
57.2 68.0 7.92 5.43 0.58 7.92 5.43 0.65 7.92 5.43 0.73 7.76 5.30 0.75 7.52 5.11 0.79 7.13 4.80 0.79
60.8 71.6 9.10 6.05 0.61 8.70 5.71 0.67 8.31 5.39 0.73 8.15 5.27 0.75 7.91 5.08 0.79 7.52 4.79 0.80
64.4 77.0 9.49 6.09 0.62 9.10 5.78 0.68 8.70 5.47 0.73 8.54 5.35 0.76 8.30 5.17 0.79 7.91 4.89 0.80
67.0 80.0 9.69 6.18 0.62 9.29 5.86 0.68 8.90 5.56 0.74 8.74 5.45 0.76
8.50 5.27 0.80 8.10 5.00 0.80
71.6 86.0 10.27 5.93 0.62 9.88 5.64 0.68 9.48 5.36 0.74 9.32 5.26 0.77 9.09 5.10 0.80 8.69 4.84 0.81
75.289.610.675.720.6310.275.450.699.875.190.759.725.090.779.484.940.809.084.700.81
AFR 9.7
Temp: Celsius / TC, SHC, PI: kW
INDOOR OUTDOOR TEMPERATURE (°CWB)
EDB –15.0 –10.0 –5.0 0 6.0 10.0
°C TC PI TC PI TC PI TC PI TC PI TC PI
15.0 1.40 0.56 1.68 0.59 1.96 0.61 2.63 0.80 3.03 0.85 3.30 0.87
21.1 1.31 0.57 1.59 0.60 1.87 0.63 2.53 0.82
2.93 0.87 3.19 0.89
22.0 1.27 0.58 1.56 0.61 1.84 0.64 2.49 0.83 2.89 0.87 3.15 0.90
24.0 1.24 0.58 1.52 0.61 1.80 0.64 2.45 0.84 2.85 0.88 3.11 0.91
25.0 1.22 0.59 1.50 0.62 1.79 0.64 2.43 0.84 2.83 0.88 3.09 0.91
27.0 1.19 0.59 1.47 0.62 1.75 0.65 2.39 0.85 2.79 0.89 3.05 0.92
Temp: Fahrenheit / TC, SHC: kBtu / PI: kW
INDOOR OUTDOOR TEMPERATURE (°FWB)
EDB 5.0 14.0 23.0 32.0 43.0 50.0
°F TC PI TC PI TC PI TC PI TC PI TC PI
59.0 4.76 0.56 5.72 0.59 6.68 0.61 8.99 0.80 10.35 0.85 11.25 0.87
70.0 4.47 0.57 5.43 0.60 6.39 0.63 8.64 0.82
10.00 0.87 10.90 0.89
71.6 4.35 0.58 5.31 0.61 6.27 0.64 8.51 0.83 9.86 0.87 10.77 0.90
75.2 4.23 0.58 5.19 0.61 6.15 0.64 8.37 0.84 9.72 0.88 10.63 0.91
77.0 4.18 0.59 5.14 0.62 6.10 0.64 8.30 0.84 9.65 0.88 10.56 0.91
80.6 4.06 0.59 5.02 0.62 5.98 0.65 8.16 0.85 9.52 0.89 10.42 0.92
EDUS041016 Capacity Tables
Room Air Conditioners J-Series 15
3D066769
Symbols Note:
AFR : Airflow rate (m
3
/min.) 1. Ratings shown are net capacities which include a deduction for indoor fan
motor heat.
2. shows nominal (rated) capacities and power input.
3. TC, PI and SHC must be calculated by interpolation using the figures in
the above tables. (Figures out of the tables should not be used for
calculation.)
4. About SHC which are not mentioned on the table, please calculate them
with around values in direct proportion.
5. Capacities are based on the following conditions.
Corresponding refrigerant piping length : 25 ft
Level difference : 0 ft
6. Airflow rate (AFR) and Bypass factor (BF) are tabulated above table.
BF : Bypass factor
EWB : Entering wet bulb temp. (°C) / (°F)
EDB : Entering dry bulb temp. (°C) / (°F)
TC : Total capacity (kW) / (kBtu/h)
SHC : Sensible heating capacity (kW) / (kBtu/h)
PI : Power input (kW)
Capacity Tables EDUS041016
16 Room Air Conditioners J-Series
FTXN12JEVJU + RXN12JEVJU
(60Hz 208/230V)
Cooling
Heating
AFR 9.3
BF 0.26
Temp: Celsius / TC, SHC, PI: kW
INDOOR OUTDOOR TEMPERATURE (°CDB)
EWB EDB 20.0 25.0 30.0 32.0 35.0 40.0
°C °C TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI
14.0 20.0 2.28 1.82 0.63 2.28 1.82 0.71 2.28 1.82 0.80 2.28 1.82 0.84 2.28 1.82 0.89 2.28 1.82 0.98
16.0 22.0 3.05 2.10 0.72 3.00 2.08 0.80 2.86 2.01 0.87 2.81 1.99 0.90 2.73 1.95 0.94 2.59 1.89 1.01
18.0 25.0 3.27 2.24 0.73 3.14 2.17 0.80 3.00 2.11 0.87 2.94 2.09 0.90 2.86 2.06 0.94 2.73 2.00 1.01
19.4 26.7 3.34 2.35 0.74 3.20 2.29 0.81 3.07 2.23 0.88 3.01 2.21 0.90
2.93 2.18 0.95 2.79 2.12 1.01
22.0 30.0 3.54 2.26 0.74 3.41 2.21 0.81 3.27 2.16 0.88 3.21 2.14 0.91 3.13 2.11 0.95 3.00 2.06 1.02
24.0 32.0 3.68 2.20 0.75 3.54 2.16 0.82 3.40 2.11 0.89 3.35 2.09 0.91 3.27 2.06 0.96 3.13 2.02 1.03
Temp: Fahrenheit / TC, SHC: kBtu / PI: kW
INDOOR OUTDOOR TEMPERATURE (°FDB)
EWB EDB 68.0 77.0 86.0 90.0 95.0 104.0
°F °F TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI
57.2 68.0 7.78 5.33 0.63 7.78 5.33 0.71 7.78 5.33 0.80 7.78 5.33 0.84 7.78 5.33 0.89 7.78 5.33 0.92
60.871.610.417.290.7210.247.130.809.776.690.879.596.510.909.316.260.948.845.860.95
64.4 77.0 11.17 7.64 0.73 10.70 7.20 0.80 10.24 6.77 0.87 10.05 6.60 0.90 9.77 6.36 0.94 9.30 5.97 0.95
67.0 80.0 11.40 7.72 0.74 10.93 7.28 0.81 10.47 6.86 0.88 10.28 6.70 0.90
10.00 6.46 0.95 9.53 6.08 0.95
71.6 86.0 12.09 7.45 0.74 11.62 7.04 0.81 11.16 6.65 0.88 10.97 6.50 0.91 10.69 6.28 0.95 10.23 5.92 0.96
75.2 89.6 12.55 7.20 0.75 12.08 6.82 0.82 11.62 6.45 0.89 11.43 6.31 0.91 11.15 6.10 0.96 10.69 5.76 0.96
AFR 10.1
Temp: Celsius / TC, SHC, PI: kW
INDOOR OUTDOOR TEMPERATURE (°CWB)
EDB –15.0 –10.0 –5.0 0 6.0 10.0
°C TC PI TC PI TC PI TC PI TC PI TC PI
15.0 1.68 0.68 2.01 0.71 2.35 0.74 3.16 0.97 3.64 1.03 3.96 1.06
21.1 1.57 0.69 1.91 0.73 2.25 0.76 3.04 1.00
3.52 1.05 3.84 1.08
22.0 1.53 0.70 1.87 0.74 2.21 0.77 2.99 1.01 3.47 1.06 3.79 1.09
24.0 1.49 0.71 1.83 0.74 2.17 0.78 2.95 1.02 3.42 1.07 3.74 1.10
25.0 1.47 0.71 1.81 0.75 2.15 0.78 2.92 1.02 3.40 1.07 3.72 1.11
27.0 1.43 0.72 1.77 0.76 2.10 0.79 2.87 1.03 3.35 1.08 3.67 1.12
Temp: Fahrenheit / TC, SHC: kBtu / PI: kW
INDOOR OUTDOOR TEMPERATURE (°FWB)
EDB 5.0 14.0 23.0 32.0 43.0 50.0
°F TC PI TC PI TC PI TC PI TC PI TC PI
59.0 5.71 0.68 6.87 0.71 8.02 0.74 10.79 0.97 12.41 1.03 13.50 1.06
70.0 5.36 0.69 6.51 0.73 7.67 0.76 10.37 1.00
12.00 1.05 13.08 1.08
71.6 5.22 0.70 6.37 0.74 7.53 0.77 10.21 1.01 11.83 1.06 12.92 1.09
75.2 5.08 0.71 6.23 0.74 7.38 0.78 10.04 1.02 11.67 1.07 12.75 1.10
77.0 5.01 0.71 6.16 0.75 7.31 0.78 9.96 1.02 11.59 1.07 12.67 1.11
80.6 4.87 0.72 6.02 0.76 7.17 0.79 9.79 1.03 11.42 1.08 12.50 1.12
EDUS041016 Capacity Tables
Room Air Conditioners J-Series 17
3D066770
Symbols Note:
AFR : Airflow rate (m
3
/min.) 1. Ratings shown are net capacities which include a deduction for indoor fan
motor heat.
2. shows nominal (rated) capacities and power input.
3. TC, PI and SHC must be calculated by interpolation using the figures in
the above tables. (Figures out of the tables should not be used for
calculation.)
4. About SHC which are not mentioned on the table, please calculate them
with around values in direct proportion.
5. Capacities are based on the following conditions.
Corresponding refrigerant piping length : 25 ft
Level difference : 0 ft
6. Airflow rate (AFR) and Bypass factor (BF) are tabulated above table.
BF : Bypass factor
EWB : Entering wet bulb temp. (°C) / (°F)
EDB : Entering dry bulb temp. (°C) / (°F)
TC : Total capacity (kW) / (kBtu/h)
SHC : Sensible heating capacity (kW) / (kBtu/h)
PI : Power input (kW)
Capacity Tables EDUS041016
18 Room Air Conditioners J-Series
7.3 Capacity correction factor by the length of refrigerant piping (Reference)
The cooling and the heating capacity of the unit has to be
corrected in accordance with the length of refrigerant piping. (The
distance between the indoor unit and the outdoor unit)
Note:
The graph shows the factor when additional refrigerant of the
proper quantity is charged.
<— line : cooling capacity>
<--- line : heating capacity>
Capacity correction factor
1
16.4 32.8 49.2
0.9
0.8
R-410A (09/12 class)
Piping length (ft)
(R11493)
Range of the refrigerant
additional charge
EDUS041016 Operation Limit
Room Air Conditioners J-Series 19
8. Operation Limit
RKN09/12JEVJU
RXN09/12JEVJU
122
114.8
104
86
68
Pull-down period
Continuous operation
Outdoor temp. (˚FDB)
50
32
866857.250 73.4 82.4
Indoor temp. (˚FWB)
Notes:
The graphs are based
on the following conditions.
• Equivalent piping length 25ft
• Level difference 0ft
• Air flow rate High
4D066173A
Heating
Cooling
68
122
114.8
59
104
50
86
41
32
68
Pull-down period
Outdoor temp. (˚FWB)
23
Continuous operation
Outdoor temp. (˚FDB)
50
Continuous operation
14
32
5
82.468 8673.457.250
(5˚FDB)
Indoor temp. (˚FWB)
50 8668
Notes:
Indoor temp. (˚FDB)
The graphs are based
on the following conditions.
• Equivalent piping length 25ft
• Level difference 0ft
• Air flow rate High
3D066174A
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98

Daikin J Series Engineeiring Data

Category
Split-system air conditioners
Type
Engineeiring Data

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI