YAMAHA POWER PRODUCTS EF2200ISY Operating instructions

Category
Power generators
Type
Operating instructions
Printed in China
2018.11×1
!
(E)
EF2200iS
OWNER’S MANUAL
Read this manual carefully before
operating this machine.
7PC-F8199-10LIT-19626-02-67
7PC-F8199-10_cover.indd 1-2 2018/11/27 11:35:06
Cover2
Read this manual carefully before operating this machine. This manual should
stay with this machine if it is sold.
7PC-F8199-10_cover.indd 3-4 2018/11/27 11:35:07
Introduction
Congratulations on your purchase of your new Yamaha.
This manual will provide you with a good basic understanding of the operation and main-
tenance of this machine.
If you have any questions regarding the operation or maintenance of your machine,
please consult a Yamaha dealer.
TIP
Yamaha continually seeks advancements in product design and quality.
Therefore, while this manual contains the most current product information available at
the time of printing, there may be minor discrepancies between your machine and this
manual. If there is any question concerning this manual, please consult a Yamaha
dealer.
This manual should be considered a permanent part of this machine and should
remain with this machine when resold.
* Product and specifications are subject to change without notice.
PLEASE READ AND UNDERSTAND THIS MANUAL COMPLETELY BEFORE OPER-
ATING THE MACHINE.
WARNING
EF2200iS
OWNER’S MANUAL
©2018 by Yamaha Motor Corporation, U.S.A.
1st Edition, November 2018
All rights reserved.
Any reprinting or unauthorized use
without the written permission of
Yamaha Motor Corporation, U.S.A.
is expressly prohibited.
Printed in China
P/N LIT-19626-02-67
7PC-F8199-10.book 1 ページ 2018年11月26日 月曜日 午後6時1分
Important manual information
Particularly important information is distinguished in this manual by the following nota-
tions.
This is the safety alert symbol. It is used to alert you to potential personal injury
hazards. Obey all safety messages that follow this symbol to avoid possible injury
or death.
A WARNING indicates a hazardous situation which, if not avoided, could result in
death or serious injury.
A NOTICE indicates special precautions that must be taken to avoid damage to the
machine or other property.
A TIP provides key information to make procedures easier or clearer.
WARNING
NOTICE
TIP
7PC-F8199-10.book 2 ページ 2018年11月26日 月曜日 午後6時1分
Contents
Safety information................. 1-1
General safety information ............... 1-1
Exhaust fumes are poisonous.......... 1-2
Fuel is highly flammable and
poisonous......................................... 1-2
Engine and muffler may be hot ........ 1-3
Electric shock prevention ................. 1-3
Connection notes ............................. 1-4
Connection ....................................... 1-4
Extension cord notes........................ 1-5
Location of important labels ............. 1-6
Controls and features ........... 2-1
Description ....................................... 2-1
Control function ................................ 2-4
Engine switch................................ 2-4
Oil level warning light (Red).......... 2-4
AC switch (N.F.B.) ........................ 2-4
Fuel tank cap ................................ 2-5
Ground (earth) terminal ................ 2-5
Economy control switch ................ 2-5
Power supply display .................... 2-6
Overload indicator light (Red) ....... 2-6
Fuel tank cap air vent lever........... 2-6
Fuel level gauge ........................... 2-7
Hour meter.................................... 2-7
Boost mode switch........................ 2-7
Twin Tech (parallel running
terminal)........................................ 2-8
Accessory socket.......................... 2-9
AC receptacle ............................... 2-9
Carburetor fuel drain cock ............ 2-9
Recoil starter................................. 2-9
Before operation.................... 3-1
Preparation....................................... 3-1
Fuel............................................... 3-1
Engine oil ...................................... 3-2
Pre-operation check ......................... 3-4
Operation................................ 4-1
Precautions for use .......................... 4-1
Starting the engine........................... 4-1
Stopping the engine ......................... 4-3
Connecting devices via Alternating
Current (AC) receptacles ................. 4-4
Connecting devices via the
accessory socket ............................. 4-5
Application range ............................. 4-7
High altitude operation ..................... 4-8
Periodic maintenance ...........5-1
The importance of maintenance ...... 5-1
Check before use............................. 5-1
Maintenance chart ........................... 5-1
Engine oil replacement .................... 5-3
Spark plug inspection....................... 5-4
Air filter cleaning .............................. 5-6
Muffler screen and spark arrester
cleaning............................................ 5-8
Fuel tank strainer cleaning............. 5-10
Carburetor adjustment ................... 5-10
Storage ...................................6-1
Drain the fuel.................................... 6-1
Engine.............................................. 6-3
Trouble recovery ...................7-1
Troubleshooting ............................... 7-1
Specifications ........................8-1
EF2200iS ......................................... 8-1
Consumer information .......... 9-1
Machine identification ...................... 9-1
Identification number records........... 9-1
7PC-F8199-10.book 1 ページ 2018年11月26日 月曜日 午後6時1分
Contents
Exhaust emission control
system and components .... 10-1
Wiring diagram .................... 11-1
Yamaha Extended Service
(Y.E.S.).................................. 12-1
Index..................................... 13-1
7PC-F8199-10.book 2 ページ 2018年11月26日 月曜日 午後6時1分
1-1
1
2
3
4
5
6
7
8
9
10
11
12
Safety information
General safety information
This generator is not designed for on-board use.
Do not use it while installed on the vehicle.
Do not modify the generator or use it with its parts
removed.
Do not allow children to operate the generator.
Be sure to carry the generator only by its carrying
handle.
Do not place any obstacles on the generator.
1
1. Carrying handle
7PC-F8199-10.book 1 ページ 2018年11月26日 月曜日 午後6時1分
1-2
Safety information
Exhaust fumes are poisonous
Using a generator indoors CAN KILL YOU IN MIN-
UTES. Generator exhaust contains carbon monox-
ide. This is a poison you cannot see or smell.
• NEVER use inside a home or garage, EVEN IF
doors and windows are open.
• Only use OUTSIDE and far away from windows,
doors, and vents.
Fuel is highly flammable and poison-
ous
Always turn off the engine when refuelling.
Never refuel while smoking or in the vicinity of an
open flame.
Take care not to spill any fuel on the engine or muf-
fler when refueling.
Do not leave the generator inside the vehicle or in the
trunk.
If you swallow any fuel, inhale fuel vapor, or allow any
to get in your eye(s), see your doctor immediately. If
any fuel spills on your skin or clothing, immediately
wash with soap and water and change your clothes.
When operating or transporting the generator, be
sure it is kept upright. If it tilts, fuel may leak from the
carburetor or fuel tank.
7PC-F8199-10.book 2 ページ 2018年11月26日 月曜日 午後6時1分
1-3
Safety information
Engine and muffler may be hot
Place the generator in a place where pedestrians or
children are not likely to touch the machine.
Avoid placing any flammable materials near the
exhaust outlet during operation.
In order to prevent overheating, ensure adequate air-
flow by keeping the machine at least 1 m (3 ft) from
objects or other equipment.
Do not operate the engine with a dust cover or other
objects covering it.
When covering the generator, be sure to do so only
after the engine and muffler have completely cooled
down.
Electric shock prevention
Never operate the engine in rain or snow.
7PC-F8199-10.book 3 ページ 2018年11月26日 月曜日 午後6時1分
1-4
Safety information
Never touch the generator with wet hands or electri-
cal shock will occur.
• Connect the ground (earth) terminal to a ground
source. In order to prevent electrical shock, the gen
-
erator must be grounded when using an electrical
device with a ground plug.
Connection notes
Avoid connecting the generator to commercial power
outlet.
Avoid connecting the generator in parallel with any
other generator.
Connection
1
1. Ground (earth) terminal
1. Correct
2. Incorrect
Before the generator can be connected to a build-
ing’s electrical system, a licensed electrician must
install an isolation (transfer) switch in the build-
ing’s main fuse box. The switch is the connection
point for generator power and allows selection of
generator or main line power to the building. This
will prevent the generator from charging the main
power line (backfeeding) when the main power
supply has failed or has been turned off for line
repair. Backfeeding can electrocute or injure line
maintenance personnel. Also, generator and build-
ing electrical system damage can occur when nor-
mal operating power returns if unit is used without
an isolation switch.
WARNING
7PC-F8199-10.book 4 ページ 2018年11月26日 月曜日 午後6時1分
1-5
Safety information
Extension cord notes
Extension cords should be protected by a tough flexible
rubber sheath (IEC 245) or the equivalent to withstand
mechanical stresses.
7PC-F8199-10.book 5 ページ 2018年11月26日 月曜日 午後6時1分
1-6
Safety information
Location of important labels
Please read the following labels carefully before operating this machine.
TIP
Maintain or replace safety and instruction labels, as necessary.
4
5
6
7
8
9
1
2
3
1
2
3
4
5
7PC-F8199-10.book 6 ページ 2018年11月26日 月曜日 午後6時1分
1-7
Safety information
6
7
8
9
AC output 60Hz
Rated
1.8kVA
120V
Phase Single
DC output 12V 3A
Fuel Gasoline
EF2200iS
7PC-F4164-10
****
************
************
************
7PC-F8199-10.book 7 ページ 2018年11月26日 月曜日 午後6時1分
2-1
1
2
3
4
5
6
7
8
9
10
11
12
13
14
Controls and features
Description
1 Carrying handle (p. 1-1) 7 Recoil starter (p. 2-9)
2 Fuel tank cap air vent lever (p. 2-6) 8 Fuel level gauge (p. 2-7)
3 Fuel tank cap (p. 2-5) 9 Muffler (p. 5-8)
4 Control panel (p. 2-1) 10 Carburetor fuel drain cock (p. 2-9)
5 Engine switch (p. 2-4) 11 Panel opener (p. 3-2)
6 Choke knob (p. 4-1)
1
3
4
5
6
7
2
8
9
10
11
7PC-F8199-10.book 1 ページ 2018年11月26日 月曜日 午後6時1分
2-2
Controls and features
Control panel
Multi-function LED meter
1 Accessory socket (p. 2-9) 5
Twin Tech (parallel running terminal)
(p. 2-8)
2 Economy control switch (p. 2-5) 6 Ground (earth) terminal (p. 2-5)
3 Multi-function LED meter (p. 2-1) 7 AC receptacle (p. 2-9)
4
Boost mode switch/Reset button
(p. 2-7/p. 2-6)
8 AC switch (N.F.B.) (p. 2-4)
1 Oil level warning light (Red) (p. 2-4) 3 Overload indicator light (Red) (p. 2-6)
2 Output indicator (Green) (p. 2-6)
1
234 5
6
778
2
3
1
7PC-F8199-10.book 2 ページ 2018年11月26日 月曜日 午後6時1分
2-3
Controls and features
This generator has an integrated multi-function LED meter. Its functions are described as
below.
Function Display Description Page
Power supply meter
Output indicator(s) come on
according to the current power
supply.
2-6
Operating time meter
Output indicator(s) flash ac-
cording to the accumulated
operation time.
2-7
Overload warning
Overload indicator light comes
on after output indicators
come on, when an overload or
some malfunctions of connect-
ed devices are detected.
2-6
Oil warning
Oil level warning light flashes
when the engine oil level is too
low.
2-4
Boost mode
Output indicators come on
consecutively when the gener-
ator is in boost mode.
2-7
7PC-F8199-10.book 3 ページ 2018年11月26日 月曜日 午後6時1分
2-4
Controls and features
Control function
Engine switch
The engine switch controls the ignition system and the
fuel cock.
TIP
The engine switch of this generator opens and closes
the fuel cock simultaneously. You don’t need to operate
the fuel cock separately.
” (RUN)
Ignition circuit is switched on, and the fuel cock opens.
The engine can be started.
” (STOP)
Ignition circuit is switched off, and the fuel cock closes.
The engine will not run.
Oil level warning light (Red)
When the oil level falls below the lower level, the oil
level warning light flashes and then the engine stops
automatically. If the light flashes, stop the engine imme
-
diately, and add engine oil up to the specified level.
Unless you refill with oil, the engine will not start again.
TIP
If the oil level warning light flashes even though the
engine oil level is sufficient, make sure to place the
generator horizontally.
AC switch (N.F.B.)
The AC switch (Non-Fuse Breaker) turns off automati-
cally when the load exceeds the generator rated out-
put.
1
3
2
1. Engine switch
2.
“” (RUN)
3.
“” (STOP)
1
1. Oil level warning light (Red)
1
1. AC switch (N.F.B.)
7PC-F8199-10.book 4 ページ 2018年11月26日 月曜日 午後6時1分
2-5
Controls and features
Fuel tank cap
Remove the fuel tank cap by turning it counterclock-
wise.
Ground (earth) terminal
Ground (earth) terminal connects the earth line for pre-
vention of electric shock.
When the electric device is grounded, be sure to
ground the generator, too.
For the grounding, consult a Yamaha dealer.
Economy control switch
In order to reduce fuel consumption and operating
noise, use the economy control switch.
” (ON)
When the economy control switch is turned to “ ” (ON),
the economy control unit regulates the engine speed
according to the connected load. The results are better
fuel consumption and less noise.
” (OFF)
When the economy control switch is turned to “
(OFF), the engine runs at the rated speed (4900 r/min)
regardless of whether a load is connected or not.
TIP
The economy control switch must be turned to “
(OFF) when using electric devices that require a
Reduce the load to the specified generator rated
output if the AC switch (N.F.B.) turns off. If it turns
off again, consult a Yamaha dealer.
NOTICE
1. Fuel tank cap
1
1. Ground (earth) terminal
1. Economy control switch
2.
“” (ON)
3.
“” (OFF)
7PC-F8199-10.book 5 ページ 2018年11月26日 月曜日 午後6時1分
2-6
Controls and features
large starting current, such as a compressor of a
submersible pump.
Economy control does not function when the genera-
tor is in warming-up period (See page 4-1).
Power supply display
The current power supply level is displayed by the out-
put indicators. According to the power supply level, the
output indicator(s) will come on.
Overload indicator light (Red)
The overload indicator light comes on when electricity
over the rated output is required by the connected elec-
trical devices, or when the inverter control unit over-
heats, or the AC output voltage rises. Then the AC
protector will trip, stopping power generation in order to
protect the generator and any connected electric
devices.
TIP
The overload indicator light may come on for a few sec-
onds at the first when using electric devices that
require a large starting current, such as a compressor
of a submersible pump. However, this is not a malfunc-
tion.
Fuel tank cap air vent lever
The fuel tank cap is provided with an air vent lever to
stop fuel flow.
The air vent lever must be turned to “ON” to run the
engine.
1
1. Output indicator (Green)
1
2
1. Overload indicator light (Red)
2. Reset button
1. Air vent lever
2. Fuel tank cap
3. “ON”
4. “OFF”
7PC-F8199-10.book 6 ページ 2018年11月26日 月曜日 午後6時1分
2-7
Controls and features
“ON”
This will allow fuel to flow to the carburetor and the
engine to run.
“OFF”
When the engine is not in use, turn the air vent lever to
“OFF” to stop fuel flow.
Fuel level gauge
The fuel level gauge shows the amount of the fuel in
the fuel tank. Make sure that sufficient fuel is in the fuel
tank before the operation.
Hour meter
The accumulated operation time is displayed by output
indicator lights “A” and “B”.
To see the time, push the reset button 3 times within 1
second in no-load running.
After one-second absence, the light “A” flashes every
1000 hours, and the light “B” flashes every 100 hours.
For example, if the light “A” flashes 2 times and the
light “B” flashes 3 times, it shows that the total opera
-
tion time is about 2300 hours.
TIP
Hour meter does not function when the generators are
in parallel operation (Twin Tech).
Boost mode switch
The boost mode switch raises up the number of rota-
tion of the engine temporarily (for approximately 60
seconds). When using devices that require a large
starting current, such as a compressor of a submers
-
ible pump or refrigerator, use this switch.
To enter the boost mode, push the boost mode switch
for 3 seconds. To exit the boost mode, push the boost
mode switch for 3 seconds again.
OFF
ON
1
FE
1. Fuel level gauge
2
3
1
1. Output indicator light “A”
2. Output indicator light “B”
3. Reset button
1. Boost mode switch
7PC-F8199-10.book 7 ページ 2018年11月26日 月曜日 午後6時1分
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62

YAMAHA POWER PRODUCTS EF2200ISY Operating instructions

Category
Power generators
Type
Operating instructions

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI