3M IL-IM-01 Operating instructions

Category
Sanitary ware
Type
Operating instructions

This manual is also suitable for

Installation and Operating Instructions For
IL-IM-01 In-line Refrigerator &
Ice-Maker Filter
Installer: Please leave manual with homeowner.
Homeowner: Please retain for operation and
future maintenance instructions.
SAFETY INFORMATION
EXPLANATION OF SIGNAL WORD CONSEQUENCES
WARNING
Read, understand, and follow all safety information contained in these instructions prior
to installation and use of the IL-IM-01 In-line Refrigerator & Ice-Maker Filter. Retain these
instructions for future reference.
Intended use:
The IL-IM-01 In-line Refrigerator & Ice-Maker Filters are intended for use in filtering potable water in
homes and have not been evaluated for other uses. The system is typically connected to a refrig-
erator, and should be installed by a qualified installer according to these installation instructions.
WARNING
Indicates a potentially hazardous situation, which, if not avoided,
could result in death or serious injury and/or property damage.
Indicates a potentially hazardous situation, which, if not avoided,
may result in property damage.
To reduce the risk associated with choking:
• Do not allow children under 3 years of age to have access to small parts during the installation of
this product.
To reduce the risk associated with ingestion of contaminants:
• Do not use with water that is microbiologically unsafe or of unknown quality without adequate
disinfection before or after the system.
To reduce the risk of physical injury:
• Depressurize system as shown in manual prior to cartridge removal.
To reduce the risk associated with property damage due to water leakage:
Read and follow Use Instructions before installation and use of this system.
Installation and Use MUST comply with all state and local plumbing codes.
Protect from freezing. Drain system when room temperature drops below 40°F (4.4°C).
Do not install systems in areas where ambient temperatures may go above 110° F (43.3° C).
Do not install on hot water supply lines. The maximum operating water temperature of this
lter system is 100°F (37.8°C).
Do not install if water pressure exceeds 125 psi (862 kPa). If your water pressure exceeds 80
psi, you must install a pressure limiting valve. Contact a plumbing professional if you are uncer-
tain how to check your water pressure.
Do not install where water hammer conditions may occur. If water hammer conditions exist you
must install a water hammer arrester. Contact a plumbing professional if you are uncertain how
to check for this condition.
Where a backow prevention device is installed on a water system, a device for controlling pres-
sure due to thermal expansion must be installed.
Do not use torch or other high temperature sources near filter or plastic fittings.
Take care when using pliers or pipe wrenches to tighten plastic ttings, as damage may occur if
over tightening occurs.
Mount lter in rear of refrigerator, adjacent cabinets, etc.
On plastic ttings, never use pipe sealant or pipe dope. Use PTFE thread sealing tape only.
Do not install in direct sunlight or outdoors.
Do not install unit if collet is missing. Contact 3M Purication Inc. if collets are missing from
any fittings.
Ensure all tubing and fittings are secure and free of leaks.
The disposable lter cartridge MUST be replaced every 6 months, at the rated capacity or
sooner if a noticeable reduction in ow rate occurs.
NOTICE
NOTICE
GETTING STARTED
Your new Aqua-Pure® In-Line Refrigerator & Ice-maker Filter is designed to be installed on the 1/4” diam-
eter cold water supply line to the refrigerator/icemaker. These filters come complete with all the necessary
hardware for installation. A shut off valve is recommended, but not provided. Each filter is rated for 2,500
gallons (9,464 liters). Filters should be changed after 6 months of use.
For use on 1/4” copper or plastic tubing.
1. Please depressurize the refrigerator in one of these three ways:
1) Shut off water flow to refrigerator/filter. Place a cup under
the dispenser area to catch water and depress the dispenser
activator.
2) Shut off water at the main water valve to the home and open
any faucet within the home.
3) Shut off water to the refrigerator/filter. Remove the automatic
ice-maker tray/bucket and empty its contents. Replace the
ice-maker tray/bucket. When the ice-maker calls for ice, the
system will be depressurized.
2. Locate an easily accessible section of tubing. Shut-off valve (not
included) must be on inlet side of filter.
3. Cut and remove a 6” (15.24 cm) section of tubing making sure
ends are cut square.
4. Connect the inlet port of the filter to incoming water line as
shown in Figure 2.
5. Flush 4 gallons (or approx. 8 minutes) through filter before use.
7. Connect the outlet port of the filter to the water line going to the
refrigerator.
8. Turn on water supply line. If leak occurs, tighten fittings or rein-
sert tubing until leak stops. If leak does not stop, turn off water
supply to refrigerator and recheck all connections.
IMPORTANT INSTALLATION INSTRUCTIONS
Figure 1 — Suggested Installation
1/4”
Tubing
1/4”
Tubing
From Cold
Water Supply
To Refrigerator/
Ice Maker
Figure 2
To attach tubing:
O-Ring
Collet
1) Push tubing in as far as it will go. Tubing must
be inserted past o-ring and hit backstop.
2) Pull tube to ensure it is secured.
3) Push in collet to release tubing.
4) With Collet held, pull tubing straight out.
To release tubing:
To reduce the risk associated with property damage due to
water leakage:
Ensure all tubing and fittings are secure and free of leaks;
Do not install unit if collet is missing. Contact 3M Purication
Inc. if collets are missing from any fittings.
IMPORTANT NOTES
• Failure to follow instructions will void warranty.
• Install with the inlet and outlet ports as labeled. Make sure not to reverse connections.
NOTICE
FILTER CARTRIDGE REPLACEMENT INSTRUCTIONS
1. Please depressurize the refrigerator in one of these three ways:
1) Shut off water flow to refrigerator/filter. Place a cup under the dispenser area to catch water and depress the
dispenser activator. You can now change-out the cartridge.
2) Shut off water at the main water valve to the home and open any faucet within the home. You can now
change-out the cartridge.
3) Shut off water to the refrigerator/filter. Remove the automatic ice-maker tray/bucket and empty its contents.
replace the ice-maker tray/bucket. When the ice-maker calls for ice, the system will be depressurized and you
can now change-out the cartridge.
2. Remove old filter by following instructions shown in Figure 2.
3. Connect the inlet port of the filter to incoming water line as shown in Figure 2.
4. Turn on water supply line. Flush 4 gallons (or approx. 8 minutes) through filter before use.
5. Connect the outlet port of the filter to the water line going to the appliance being served.
6. If leak occurs, tighten fittings or reinsert tubing until leak stops.
3M Purification Inc. warrants this Product will be free from defects in material and manufacture for one year from the
date of purchase. This warranty does not cover failures resulting from abuse, misuse, alteration or damage not caused
by 3M Purification Inc. or failure to follow installation and use instructions. No warranty is given as to the service life of
any filter cartridge or membrane as it will vary with local water conditions and water consumption. 3M PURIFICATION
INC. MAKES NO OTHER WARRANTIES OR CONDITIONS, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED
TO, ANY IMPLIED WARRANTY OR CONDITION OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE
OR ANY IMPLIED WARRANTY OR CONDITION ARISING OUT OF A COURSE OF DEALING, CUSTOMER OR USAGE OF
TRADE. If the Product fails to satisfy this Limited Warranty during the warranty period, 3M Purification Inc. will replace
the Product or refund your Product purchase price. This warranty does not cover labor. The remedy stated in this
paragraph is Customer’s sole remedy and 3M Purification Inc.’s exclusive obligation.
This warranty gives you specific legal rights, and you may have other rights which may vary from state to state, or
country to country. For any warranty questions, please call 1-800-222-7880 or mail your request to: Warranty Claims,
3M Purification Inc., 400 Research Parkway, Meriden, CT 06450. Proof of purchase (original sales receipt) must
accompany the warranty claim, along with a complete description of the Product, model number and alleged defect.
Limitation of Liability. 3M Purification Inc. will not be liable for any loss or damage arising from this 3M Purification
Inc. product, whether direct, indirect, special, incidental, or consequential, regardless of the legal theory asserted,
including warranty, contract, negligence or strict liability. Some states and countries do not allow the exclusion of limi-
tation of incidental or consequential damages, so the above limitation or exclusion may not apply to you.
LIMITED WARRANTY
SPECIFICATIONS
Model
Service
Flow Rate
Service Life Max. Pressure
Max.
Temperature
Replacement
Cartridge
IL-IM-01
0.5 gpm
(1.89 lpm)
2,500 gallons
(9,464 liters)
125 psi
(862 kPa)
100°F
(37.8°C)
5617202
To reduce the risk associated with property damage due to water leakage:
The disposable lter cartridge MUST be replaced every 6 months, at the rated capacity or sooner if a noticeable reduc-
tion in ow rate occurs.
NOTICE
3M and Aqua-Pure are trademarks of 3M Company.
© 2014 3M Company. All rights reserved.
3M Purification Inc.
400 Research Parkway
Meriden, CT 06450 USA
Toll Free: 1-800-222-7880
Worldwide: 203-237-5541
Fax: 203-238-8701
www.aquapure.com • www.3Mpurication.com
34-8715-7709-3
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12

3M IL-IM-01 Operating instructions

Category
Sanitary ware
Type
Operating instructions
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI

in other languages