biOrb Biorb Life Owner's manual

Type
Owner's manual
LIFE / FLOW / TUBE / CLASSIC / CUBE
48039_GA_bi_LIFE_FLOW_TUBE_CLASSIC_CUBE_A5.indd 1 14.06.17 09:27
2 biOrb CLASSIC / FLOW / CUBE / LIFE / TUBE
A
BOB0001
3
B
BOB0002
4 biOrb CLASSIC / FLOW / CUBE / LIFE / TUBE
C
BOB0003
D
BOB0004
5
E
BOB0005
6 biOrb CLASSIC / FLOW / CUBE / LIFE / TUBE
F
BOB0006
G
BOB0007
7
H
BOB0008
8 biOrb CLASSIC / FLOW / CUBE / LIFE / TUBE
I
BOB0009
J
BOB0010
9
K
BOB0011
- DE -
15
TECHNISCHE DATEN
Beschreibung
biOrb
CLASSIC
FLOW
CUBE
LIFE
TUBE
Bemessungsspannung Steckertrafo Primär
V AC
230
230
230
230
230
Spannung Steckertrafo Sekundär
V AC
12
12
12
12
12
Netzfrequenz
Hz
50
50
50
50
50
Schutzart
IP20
IP20
IP20
IP20
IP20
Leistung Belüfterpumpe
W
0,8
0,8
0,8
0,8
0,8
Bemessungsspannung Belüfterpumpe
V AC
12
12
12
12
12
Länge Anschlussleitung Belüfterpumpe
m
1,5
1,5
1,5
1,5
1,5
SYMBOLE AUF DEM GERÄT
Geschützt vor Berührung mit den Fingern
Schutzklasse II, sichere elektrische Trennung vom Netz durch verstärkte oder doppelte Isolierung
Im Innenraum verwenden
Nicht mit normalem Hausmüll entsorgen
Gebrauchsanleitung lesen und beachten
- EN -
16 biOrb CLASSIC / FLOW / CUBE / LIFE / TUBE
- EN -
Translation of the original Operating Instructions
WARNING
This unit can be used by chil-
dren aged 8  and above and by
persons with reduced physical,
sensory or mental capabilities
or lack of experience and
knowledge if they are super-
vised or have been instructed
on how to use the unit in a safe
way and they understand the
hazards involved.
Do not allow children to play
with the unit.
Only allow children to carry
out cleaning and user mainte-
nance under supervision.
Do not use the unit if electrical
cables or housings are dam-
aged.
Only connect the unit if the
electrical data of the unit and
the power supply correspond.
The unit data is to be found on
the unit type plate, on the
packaging or in this manual.
Switch off all units in the
aquarium or disconnect the
power plugs of all units before
reaching into the water.
Disconnect the power plug be-
fore carrying out any work on
the unit.
SAFETY INFORMATION
Never operate the unit if the housing is defective!
Never operate the unit if any electrical cables are
defective!
Never carry or pull the unit by the electrical cable.
Route cables such that they are protected from
damage and do not present a tripping hazard.
Only open the unit housing or its attendant compo-
nents if this is explicitly specified in the operating in-
structions.
Only carry out work on the unit that is described in
this manual. If problems cannot be overcome,
please contact an authorised customer service point
or, if in doubt, the manufacturer.
Only use original spare parts and accessories for the
unit.
Never carry out technical changes to the unit.
When using heaters, ensure that they are approved
for use in the aquarium and that they do not come
into contact with the acrylic wall of the aquarium.
Suitable heaters meet the requirements in ac-
cordance with EN 60335-2-55.
Protect the plug connection from moisture.
Only connect the unit to a correctly fitted socket.
Symbols used in these instructions
Warnings
The warning information is categorised by signal
words, which indicate the extent of the hazard.
WARNING
Indicates a possibly hazardous situation.
Non-observance may lead to death or serious inju-
ries.
NOTE
Information for the purpose of clarification or for pre-
venting possible damage to assets or to the environ-
ment.
Additional information
A Reference to a figure, e.g. Fig. A.
- EN -
17
PRODUCT DESCRIPTION
Check that the delivery scope is correct, complete
and undamaged.
A
biOrb CLASSIC / FLOW / CUBE / LIFE / TUBE
1
Lighting unit with connection cable and ON/OFF
switch*
2
Cover insert
3
Bubble tube
4
Air hose with integrated non-return valve
5
Filter unit
6
Aerator pump with connection cable
7
Plug-in transformer
8
Bag with Water Conditioner and/or Biological Booster
9
Ceramic substrate**
10
biOrb aquarium operating manual
11
Lighting unit operating manual*
*Supply and version are product-specific.
**Quantity is product-specific.
WARNING
Danger of suffocation.
Keep plastic bags and small parts out of reach of babies
and young children.
Intended use
biOrb CLASSIC / FLOW / CUBE / LIFE / TUBE may only
be used as follows:
As an aquarium.
The supplied components may only be used for the bi-
Orb products as specified in the following:
The aerator pump: For aeration and supplying oxy-
gen to the aquarium.
The lighting unit: For lighting the aquarium.
The plug-in transformer: For connecting the aerator
pump and lighting unit to the mains.
Operation under observance of the technical data.
The following restrictions apply to the aquarium and
its components:
Only operate with water at a water temperature of
+4 °C to +35 °C.
Function description
Aquarium with LED lighting, filter unit and external
aerator pump for circulating the water.
INSTALLATION AND CONNECTION
Setting up the aquarium
How to proceed:
Carefully unpack the acrylic aquarium.
Do not expose to direct sunlight.
For indoor use only.
Do not move the aquarium when it is filled.
Do not place on or near electrical devices.
Do not place on or near heat sources.
Operation under observance of the technical data.
Fitting the filter unit
How to proceed:
Remove the packaging from the filter medium.
B
1. Release the bubble tube from the filter housing by
a quarter turn counterclockwise (bayonet closure)
and lift out.
2. Place the bubble tube onto the filter cartridge and
fasten the bubble tube by a quarter turn counter-
clockwise.
3. Insert the bubble tube into the aquarium and fasten
it to the filter housing by a quarter turn clockwise.
Using the ceramic substrate
NOTE
Remove the packaging from the filter medium. Thor-
oughly rinse the ceramic substrate with warm tap wa-
ter before using for the first time to remove any soil-
ing.
NOTE
Do not use aquarium gravel as it could clog the filter
cartridge.
Only use the ceramic substrate provided.
Do not tip the ceramic substrate into the aquarium
from a height as it could scratch the acrylic.
Only use ceramic substrate particles that are at least
pea-sized. Remove and dispose of any particles that
are smaller.
How to proceed:
C
Wash and then place the supplied ceramic substrate
carefully into the aquarium and arrange it around
the filter housing.
- EN -
18 biOrb CLASSIC / FLOW / CUBE / LIFE / TUBE
Installing and connecting the aerator pump
NOTE
When installing the unit, ensure that it
is located outside the aquarium
is not placed on or over the aquarium
cannot fall into the water or move out of position.
Damage resulting from incorrect installation is not ba-
sis for a claim within the framework of the guarantee
or warranty.
How to proceed:
D
1. Connect the air hose leading out of the aquarium to
the air connection of the aerator pump and fit the
aerator pump above the subsequent level of the
aquarium water.
This prevents water from leaking or damage to
the pump in case the integrated non-return valve
should fail.
2. Connect the connection cable of the aerator pump
to the separate socket of the plug-in transformer so
that it forms a drip loop.
Always connect the aerator pump to the plug-in
transformer first, then connect the plug-in trans-
former to the power socket.
(→ Commissioning/start-up)
Connecting the lighting unit
See the separately included operating manual.
COMMISSIONING/START-UP
Filling with and preparing the water
It is necessary to prepare the aquarium water by add-
ing "Water Conditioner" and "Biological Booster".
How to proceed:
E, F
1. Fill the aquarium with 2 litres of tap water.
2. Insert the plug-in transformer into the socket to
switch on the aerator pump.
3. Fill the aquarium with more tap water up to about
5 cm below the cover.
4. Cut open the "Water Conditioner" bag and sprinkle
the contents into the water.
5. Once the pump has been running for at least 24 h,
sprinkle the contents of the "Biological Booster" bag
into the water.
Switching the aerator pump on/off
NOTE
Never operate the aerator pump by itself, i. e. without
the air hose and air stone connected.
How to proceed:
F
Switching on: Connect plug-in transformer to the
socket. The unit switches on immediately when the
power connection is established.
Switching off: Disconnect the plug-in transformer.
Switching the lighting unit on/off
See the separately included operating manual.
REMEDY OF FAULTS
Malfunction
Cause
Remedy
The water becomes soiled within a
short time.
The filter cartridge is exhausted.
Replace the filter cartridge.
Overfeeding
Reduce the amount of food.
Too many fish
Reduce the number of fish.
Aerator pump doesn't start up.
No mains voltage
Check the connection of the aerator pump at
the transformer
Check the mains voltage.
Aerator pump defective
Replace the aerator pump.
Aerator pump is noisy.
Aerator pump is vibrating.
Place the aerator pump onto a softer sur-
face.
Fewer air bubbles in the air tube than
normal
Air stone is exhausted.
Replace the air stone.
The aerator pump is noisy and there
are still fewer air bubbles even after
replacement of the air stone.
The aerator pump is only functioning to a
limited extent.
Replace the aerator pump immediately.
- EN -
19
MAINTENANCE AND CLEANING
Cleaning and maintenance work:
Area
Tasks to be carried out
Lighting unit
Clean when necessary.
Change the batteries in the
remote control when neces-
sary.
Aquarium water
Partially change every 4 to 6 weeks.
Together with the filter cartridge.
Filter cartridge.
Replace every 4 to 6 weeks depend-
ing on the number of fish.
Air stone
Replace every 6 months.
Aerator pump
Replace every 12 months if neces-
sary.
Filter cartridge, water treatment sachets and a clean-
ing pad are available as OASE biOrb Service Kit (46014).
Preparing the water
Prerequisite:
Fresh water has been treated with "Water Condi-
tioner" 24 h beforehand and has reached room tem-
perature. Required quantity: Approx. one third of the
aquarium volume.
How to proceed:
G
1. Remove the water to be replaced and clean the
aquarium with the cleaning pad for acrylic glass if
necessary.
OASE recommends:
biOrb cleaner pump (46025)
Cleaning pads (46027, only use the rough side for
particularly stubborn deposits).
2. Top up the aquarium with the treated water.
Replacing the filter cartridge
NOTE
Switch off the aerator pump before commencing
with this maintenance work.
Switch on the aerator pump again after completing
the work.
How to proceed:
Remove the packaging from the filter medium.
H
1. Release the bubble tube from the filter housing by
a quarter turn counterclockwise (bayonet closure)
and remove and dispose of the old filter cartridge.
2. Release the bubble tube from the filter cartridge by
a quarter turn clockwise and lift out.
3. Place the bubble tube onto the new filter cartridge
and fasten by a quarter turn counterclockwise.
4. Insert the bubble tube into the aquarium and fasten
by a quarter turn clockwise.
Replacing the air stone
How to proceed:
I
1. Remove the bubble tube and filter cartridge.
2. Pull off the air stone and replace.
3. Insert the filter cartridge into the bubble tube and
install the bubble tube.
Checking the non-return valve
A non-return valve is defective if water can flow out of
the aquarium into the air hose.
How to proceed:
J
1. Switch off the aerator pump and pull the air hose
from the aerator pump.
2. Hold this end lower than the water level in the
aquarium.
3. If any water emerges, it is necessary to replace the
non-return valve. (→ Replacing the non-return
valve)
Replacing the non-return valve
Prerequisite:
The aerator pump is switched off and the air hose
has been removed from the aerator pump.
How to proceed:
K
1. If the defective valve cannot be removed, cut open
the air hose as near as possible to the defective non-
return valve and fit the new non-return valve there.
2. Replace the defective non-return valve.
The non-return valve is supplied with the air hose
fitted.
Ensure that it is correctly positioned.
3. Fit the air hose onto the aerator pump again before
switching on the aerator pump again.
WEAR PARTS
Aerator pump
Ceramic substrate
Air stone
Filter cartridge.
- EN -
20 biOrb CLASSIC / FLOW / CUBE / LIFE / TUBE
DISPOSAL
NOTE
Do not dispose of this unit with domestic waste.
Render the unit unusable beforehand by cutting the
cables and dispose of the unit via the return system
provided for this purpose.
GUARANTEE
For this OASE unit purchased by you, OASE GmbH as-
sumes a 24 month manufacturer's guarantee in ac-
cordance with the guarantee conditions laid down in
the following. The guarantee period starts with the
first purchase from an OASE specialist dealer. In other
words, in the event of a resale, the guarantee period
will not start again. If services are provided under the
terms of this guarantee, this does not lead to exten-
sion or renewal of the guarantee period. Your legal
rights as a purchaser, especially those ensuing from
the warranty, persist. They are not restricted by this
guarantee.
Guarantee conditions
OASE GmbH guarantees impeccable, purpose-related
properties and workmanship, expert assembly and
proper functionality. Subject to our discretion, the
guarantee refers to free-of-charge repair or free-of-
charge supply of spare parts or of a replacement unit
respectively. Should the unit type concerned no longer
be manufactured, we reserve the right, at our discre-
tion, to supply a replacement unit from our range that
is closest to the type subject to complaint. Claims, the
origin of which can be traced back to installation and
operating faults as well as lack of care, e.g. the use of
unsuitable cleaning materials or negligent mainte-
nance, use other than that intended, damage due to
accidents, falls, impact, effect of frost, cutting plugs,
shortening cables, calcium deposits or improper at-
tempts to repair the unit, are not covered by our guar-
antee. We hereby refer to the proper use as specified
in the instructions of use that form an integral part of
the guarantee. Wear parts such as bulbs etc. are ex-
empted from the guarantee.
The refund of costs for removal and installation,
checks, claims for lost profit and damages are ex-
empted from the guarantee together with further
reaching claims for damages and loss of whatever na-
ture caused by the unit or its use.
The guarantee is only valid in the country in which the
unit was purchased from an OASE dealer. This guaran-
tee is governed by German law under the exclusion of
the agreement of the United Nations covering con-
tracts governing the international sale of goods (CISG)
regulations.
Guarantee claims can only be brought forward by pre-
senting the sales receipt to us, OASE GmbH, Tecklen-
burger Straße 161 in D-48477 Hörstel, Germany by re-
turning to us the unit or part of the unit subject to
complaint, freight free, at your own risk, accompanied
by a copy of the original purchase receipt from the
OASE specialist dealer, this guarantee document and
written information of the fault encountered.
SPARE PARTS
The use of original parts from OASE ensures continued
safe and reliable operation of the unit.
Please visit our website for spare parts drawings and
spare parts.
www.oase-livingwater.com/spareparts-ia
- EN -
21
TECHNICAL DATA
Description
biOrb
CLASSIC
FLOW
CUBE
LIFE
TUBE
Primary rated voltage of plug-in transformer
V AC
230
230
230
230
230
Secondary voltage of plug-in transformer
V AC
12
12
12
12
12
Mains frequency
Hz
50
50
50
50
50
Protection type
IP20
IP20
IP20
IP20
IP20
Aerator pump rating
W
0.8
0.8
0.8
0.8
0.8
Aerator pump rated voltage
V AC
12
12
12
12
12
Length of connection cable of the aerator pump
m
1.5
1.5
1.5
1.5
1.5
SYMBOLS ON THE UNIT
Protected from contact with fingers.
Protection class II, reliable electrical isolation from the mains by reinforced or double insulation.
For use indoors.
Do not dispose of with household waste.
Read and adhere to the instructions for use.
- FR -
27
CARACTERISTIQUES TECHNIQUES
Description
biOrb
CLASSIC
FLOW
CUBE
LIFE
TUBE
Tension de référence adaptateur secteur primaire
V AC
230
230
230
230
230
Tension de référence adaptateur secteur secon-
daire
V AC
12
12
12
12
12
Fréquence de réseau
Hz
50
50
50
50
50
Indice de protection
IP20
IP20
IP20
IP20
IP20
Puissance de la pompe d'oxygénation
W
0,8
0,8
0,8
0,8
0,8
Tension de référence pompe d'oxygénation
V AC
12
12
12
12
12
Longueur câble de raccordement pompe d'oxygé-
nation
m
1,5
1,5
1,5
1,5
1,5
SYMBOLES SUR L'APPAREIL
Protégé du contact avec les doigts
Classe de protection II, isolation renforcée et doublée pour une séparation électrique fiable avec le ré-
seau
Pour une utilisation en intérieur
A ne pas évacuer dans les ordures ménagères
Lire et respecter la notice d'utilisation
- NL -
30 biOrb CLASSIC / FLOW / CUBE / LIFE / TUBE
Luchtpomp opstellen en aansluiten
OPMERKING
Waarborg bij het opstellen van het apparaat, dat het
apparaat
zich buiten het aquarium bevindt.
niet op of boven het aquarium is geplaatst.
niet in het water kan vallen of terecht kan komen.
Schade door verkeerde plaatsing valt niet onder de ga-
rantie of aansprakelijkheid.
Zo gaat u te werk:
D
1. De luchtslang die uit het aquarium komt met de
luchtaansluiting op de luchtpomp verbinden en de
luchtpomp boven het beoogde waterpeil van het
aquarium opstellen.
Zo wordt het uitlopen van het water of schade
aan de pomp verhinderd, mocht de terugslagklep
falen.
2. Aansluitsnoer van de luchtpomp in de aparte aan-
sluiting in de netadapter steken en zo aanleggen dat
deze een druppellus vormt.
Altijd eerst de luchtpomp met de netadapter ver-
binden, dan de netadapter in de contactdoos ste-
ken. (→ Inbedrijfstelling)
Verlichtingsunit aansluiten
Zie extra bijgesloten gebruiksaanwijzing.
INBEDRIJFSTELLING
Water in aquarium doen en voor vissen geschikt ma-
ken
Het aquariumwater moet door toevoeging van “Water
Conditioner” of. “Biological Booster” geschikt gemaakt
worden.
Zo gaat u te werk:
E, F
1. Doe 2 liter leidingwater in het aquarium.
2. Plaats de stekkertrafo in de contactdoos, om de
luchtpomp in te schakelen.
3. Vul het aquarium verder met leidingwater tot ca.
5 cm onder het deksel vullen.
4. Het zakje met “Water Conditioner” openknippen en
de inhoud daarvan in het water strooien.
5. Na minimaal 24 h looptijd de inhoud van het zakje
Biological Booster” in het water strooien.
Luchtpomp inschakelen / uitschakelen
OPMERKING
Nooit de luchtpomp zonder aangesloten slang en
luchtuitstromer laten werken.
Zo gaat u te werk:
F
Inschakelen: Plaats de stekkertrafo in de contactdoos.
Het apparaat schakelt zichzelf onmiddellijk in, als de
elektrische aansluiting tot stand is gebracht.
Uitschakelen: Trek de stekkertrafo uit de contactdoos.
Verlichtingsunit inschakelen / uitschakelen
Zie extra bijgesloten gebruiksaanwijzing.
STORING VERHELPEN
Storing
Oorzaak
Oplossing
Water raakt snel vervuild
Filterelement niet langer effectief
Filterelement reinigen
Voervolume te hoog
Minder voeren
Vissenbestand te groot
Vissenbestand verkleinen
Luchtpomp start niet
Er is geen netspanning
Aansluiting luchtpomp op netadapter controle-
ren
Netspanning controleren
Luchtpomp defect
Luchtpomp vervangen
Luchtpomp maakt lawaai
Luchtpomp trilt
Luchtpomp op zachtere ondergrond plaat-
sen
Minder luchtbellen uit luchtbuis dan
normaal
Luchtuitstromer verstopt
Luchtuitstromer vervangen
Luchtpomp maakt lawaai en produ-
ceert zelfs na vervanging van de
luchtuitstromer minder bellen dan
normaal
Luchtpomp werkt niet goed
Luchtpomp meteen vervangen
- NL -
33
TECHNISCHE GEGEVENS
Omschrijving
biOrb
CLASSIC
FLOW
CUBE
LIFE
TUBE
Nominale spanning stekkertrafo primair
V~AC
230
230
230
230
230
Spanning stekkertrafo secundair
V~AC
12
12
12
12
12
Netfrequentie
Hz
50
50
50
50
50
Beschermingsgraad
IP20
IP20
IP20
IP20
IP20
Vermogen luchtpomp
W
0,8
0,8
0,8
0,8
0,8
Nominale spanning luchtpomp
V~AC
12
12
12
12
12
Lengte aansluitsnoer luchtpomp
m
1,5
1,5
1,5
1,5
1,5
SYMBOLEN OP HET APPARAAT
Beschermd tegen aanraking met de vingers
Beschermingsklasse II, veilige scheiding van het net door versterkte of dubbele isolatie
Binnen gebruiken.
Niet verwijderen samen met het normale huishoudelijke afval.
Gebruikshandleiding lezen en aanhouden
- ES -
39
DATOS TÉCNICOS
Descripción
biOrb
CLASSIC
FLOW
CUBE
LIFE
TUBE
Tensión asignada transformador con enchufe pri-
mario
V AC
230
230
230
230
230
Tensión asignada transformador con enchufe se-
cundario
V AC
12
12
12
12
12
Frecuencia de red
Hz
50
50
50
50
50
Categoría de protección
IP20
IP20
IP20
IP20
IP20
Potencia de la bomba de aireación
W
0,8
0,8
0,8
0,8
0,8
Tensión asignada de la bomba de aireación
V AC
12
12
12
12
12
Longitud línea de conexión de la bomba de airea-
ción
m
1,5
1,5
1,5
1,5
1,5
SÍMBOLOS EN EL EQUIPO
Protegido contra contacto con los dedos.
Categoría de protección II, separación eléctrica segura de la red mediante aislamiento reforzado o doble.
Emplear en interiores
No desechar el equipo en la basura doméstica.
Leer y tener en cuenta las instrucciones de uso
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108
  • Page 109 109
  • Page 110 110
  • Page 111 111
  • Page 112 112
  • Page 113 113
  • Page 114 114
  • Page 115 115
  • Page 116 116
  • Page 117 117
  • Page 118 118
  • Page 119 119
  • Page 120 120
  • Page 121 121
  • Page 122 122
  • Page 123 123
  • Page 124 124
  • Page 125 125
  • Page 126 126
  • Page 127 127
  • Page 128 128
  • Page 129 129
  • Page 130 130
  • Page 131 131
  • Page 132 132
  • Page 133 133
  • Page 134 134
  • Page 135 135
  • Page 136 136
  • Page 137 137
  • Page 138 138
  • Page 139 139
  • Page 140 140
  • Page 141 141
  • Page 142 142

biOrb Biorb Life Owner's manual

Type
Owner's manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI