evoheat EVO0150-1 Hot Water Heat Pump User manual

Type
User manual

evoheat EVO0150-1 Hot Water Heat Pump can efficiently provide clean and economical hot water for your home all year round. With a 150L storage capacity, this heat pump features advanced energy-saving technology and built-in smart functions for efficient heating. It operates at a maximum temperature of 60°C and has a heating output of 1.7kW.

evoheat EVO0150-1 Hot Water Heat Pump can efficiently provide clean and economical hot water for your home all year round. With a 150L storage capacity, this heat pump features advanced energy-saving technology and built-in smart functions for efficient heating. It operates at a maximum temperature of 60°C and has a heating output of 1.7kW.

info@evoheat.com.au
1300 859 933
www.evoheat.com.au
Evo150-1 Manual
Page 1
Contents
1. Introduction ................................................................................................................................................. 2
2. Dimensions ................................................................................................................................................. 2
3. Quick Start Guide ....................................................................................................................................... 3
4. Safety Instructions ...................................................................................................................................... 4
5. Installation ................................................................................................................................................... 5
5.1 System Installation ................................................................................................................................ 5
5.2 Handing & Transportation ..................................................................................................................... 5
5.3 Location of Installation .......................................................................................................................... 6
5.3.1 Indoor Installation ........................................................................................................................... 6
5.4 Airflow Clearances ................................................................................................................................ 6
5.5 Cable Connection .................................................................................................................................. 6
5.6 Filling the Tank ...................................................................................................................................... 6
5.7 Initial Start-Up ....................................................................................................................................... 6
6. Operation .................................................................................................................................................... 7
6.1 The Controller ....................................................................................................................................... 7
6.2 Operating Functions .............................................................................................................................. 8
6.2.1 Startup & Shutdown ........................................................................................................................ 8
6.2.2 Switching Modes ............................................................................................................................ 8
6.2.3 Locking the Controller ..................................................................................................................... 8
6.2.4 Setting & Checking the Target Temperature .................................................................................. 9
6.2.5 Hydroboost Setting ......................................................................................................................... 9
6.2.6 Force Defrost .................................................................................................................................. 9
6.2.7 Fan/Ventilation Function ............................................................................................................... 10
6.2.8 System Date & Time ..................................................................................................................... 10
6.2.9 Setting & Cancelling Timers ......................................................................................................... 11
6.2.10 Vacation Mode ............................................................................................................................ 12
6.2.11 Sanitech System ......................................................................................................................... 12
7. Troubleshooting ........................................................................................................................................ 13
8. Appendix ................................................................................................................................................... 14
8.1 Wiring Diagram ................................................................................................................................... 14
8.2 Wi-Fi Module Connection (Optional) ................................................................................................... 14
8.3 Use of the P&T Valve .......................................................................................................................... 15
8.4 Using the Overheating Protector ......................................................................................................... 15
8.5 Draining the Water Tank ..................................................................................................................... 15
9. Maintenance ............................................................................................................................................. 16
10. Warranty ................................................................................................................................................. 17
info@evoheat.com.au
1300 859 933
www.evoheat.com.au
Evo150-1 Manual
Page 2
1. Introduction
This manual contains information relating to the installation, troubleshooting, operation, and maintenance of this
EvoHeat unit. Instructions in this manual must always be followed. Failure to comply with these recommendations will
invalidate the warranty. Should you have any questions or require technical support, call the EvoHeat office on 1300
859 933 to speak to our team.
The data and information contained in this manual is correct at the time of publishing and is subject to change without
notice. For the most up to date manual, contact EvoHeat directly.
TECHNICAL DATA Evo150-1
The EVO 150-1 is the next evolution in water heating with
advanced energy efficiency technologies and built-in
smart features to ensure you’re provided with clean, safe,
and economical hot water all year round.
Conforms to AS 3498-2020 Australia and New Zealand
Measurement conditions: Instant heating: Ambient air temperature
20°C/15°C, water inlet 15°C, water outlet 55°C, highest setting
temperature: 75°C
Working Temp Range
1. Ambient temperature is -5°C ~ 43°C (Heat Pump)
2. The max temperature of water tank is 70
Operating parameters: The range of the operating water pressures:
0.15~0.85MPa
Storage Capacity L 150
Max Temperature Setting ˚C 60
Power Input kW 0.45
Heating Output kW 1.7
C.O.P at 20˚C Air 3.76
Noise Rating dB(A) 45
Running Current A 1.88
Power Supply 220-240V/1/50Hz
Water Inlet/Outlet Size mm 20 (3/4”)
Auxiliary Heating kW 1.5
Operating Temperature Range ˚C -5 to 43
Hot Water Recovery L/hr 36
With Hydro Boost L/hr 66
Net Weight kg 91
2. Dimensions
Evo150-1
A
B
C
D
E
DIAMETER
1623.5
1118
427
895
795
568
info@evoheat.com.au
1300 859 933
www.evoheat.com.au
Evo150-1 Manual
Page 3
3. Quick Start Guide
DO NOT DRILL
Do not drill any fixings or attachments into the outer casing of the tank. Drilling into the outer casing of the
tank may damage the heating coil and WILL VOID WARRANTY.
INITIAL STARTUP
1. Press and hold for one second to power on the unit.
2. To set the time:
a. Press once so the hour digit starts flashing,
b. Use to adjust the hour and press to confirm,
c. Repeat for the minute, day, month and year,
d. Press at any stage to cancel.
3. Press until is displayed. This will activate “Eco Heating” (Heat Pump only) mode and will provide
the most efficient heating.
4. During periods of unusually high hot water demand (such as additional occupants staying with you), you can
activate “High Requirement” mode by pressing until is displayed.
5. In any event where there is a failure within the system, the Electric Element (Hydroboost Mode) can be
engaged with “one push activation” of the button until is displayed. This will provide emergency
water heating until service can be attended.
6. For adjustment of timers or activating vacation mode, please refer to our online tutorials at:
www.evoheat.com.au/tech-support
info@evoheat.com.au
1300 859 933
www.evoheat.com.au
Evo150-1 Manual
Page 4
4. Safety Instructions
Ensure that all safety instructions and recommendations are always adhered to. Failure to comply with these
recommendations could void the warranty and cause injury or death.
fully qualified technician.
The Evo150-1 must be installed to conform to all relevant
Australian Standards and Industry Codes including but
not limited to: Electrical & Electrical Safety, Plumbing &
Hot Water Storage, Heat Pump Installation & Operation
A circuit breaker must be installed for the unit.
Ensure the unit has a good power connection and
earthing to avoid the risk of electrical shocks.
Ensure that there are no leaks on both the plumbing and
drainage fittings.
The unit must not be installed near flammable gas or have
flammable aerosols sprayed in the vicinity.
The base that the unit is installed on must be level and
stable.
If the supply cord is damaged, it must be replaced by a
qualified service agent.
This appliance must be installed in accordance with
national wiring regulations.
Installation must also comply with any local, state or
federal codes at the installation site. Failure to comply can
void your warranty, damage your unit or possible cause
injury or death. Plumbing must comply with
AS/NZS3500.4
Before obtaining access to terminals all supply circuits
must be disconnected.
A P&T valve MUST be installed in the tank. When the
tank pressure reaches 0.85MPa or when the tank
temperature reaches 99°C, the P&T valve will open
automatically so as to reduce the pressure or temperature
decrease.
In the event of the unit malfunctioning, shut off the
power supply and contact your supplier or EvoHeat.
In order to use the unit correctly, run the unit at
environment temperature -5°C - 43°C
The unit contains sophisticated electronic devices, do
not use unsafe water sources such as lake or
groundwater.
The unit produces hot water and will also have hot
fittings, therefore should not be touched to avoid injury.
Do not drill any fixings or attachments into the outer
casing of the tank. Drilling into the outer casing of the
tank may damage the heating coil and WILL VOID
WARRANTY.
If the unit stops and you restart the unit or turn it on
manually, the unit will not start to run again for
approximately 3 minutes. This is a protection feature to
safeguard the compressor.
The handle of the P&T safety valve should be tested
once every six months to remove the calcium
carbonate deposits and guarantee there is no blockage
in the device.
Once installation is complete, check that all
connections are secure before the power is turned on.
The installer is to explain to the end user how to
operate and maintain the unit in accordance with this
instruction manual.
Evo Industries Australia Pty Ltd will not be held
responsible for any damages or injuries caused by the
incorrect installation of this hot water system.
A maintenance programme must be carried out as
recommended in this manual to ensure ongoing
reliability.
To reduce the risk of excessive pressures and temperatures in this water heater, install temperature and pressure protective
equipment required by local codes and no less than a combination temperature and pressure relief valve certified by a nationally
recognized testing laboratory that maintains periodic inspection of production of listed equipment or materials, as meeting the
requirements for Relief Valves and Automatic Gas Shutoff Devices for Hot Water Supply Systems, ANSIZ21.22. This valve must be
marked with a maximum set pressure not to exceed the marked maximum working pressure of the water heater. Install the valve
into an opening provided and marked for this purpose in the water heater, and orient it or provide tubing so that any discharge from
the valve exits only within 6 inches above, or at any distance below, the structural floor, and does not contact any live electrical
part. The discharge opening must not be blocked or reduced in size under any circumstances.
Hydrogen gas is produced in a hot water system served by this heater that has not been used for a long period of time (2 weeks or
more). Hydrogen gas is extremely flammable. To reduce the risk of injury under these conditions, it is recommended that the hot
water faucet be opened for several minutes at the kitchen sink before using
any electrical appliance.
The appliance is fitted with means for disconnection from the supply mains
having a contact separation in all poles that provide full disconnection under
overvoltage category lll conditions, and these means must be incorporated in
the fixed wiring in accordance with the wiring rules.
info@evoheat.com.au
1300 859 933
www.evoheat.com.au
Evo150-1 Manual
Page 5
5. Installation
5.1 System Installation
Upon receiving the unit, check the packaging for any obvious signs of damage. Inform EvoHeat immediately if there is
any evidence of rough handling.
Do not drill any fixings or attachments into the outer
casing of the tank. Drilling into the outer casing of the
tank may damage the heating coil and WILL VOID
WARRANTY.
The P&T valve attached with the unit must be installed.
Failure to do so will cause damage to the unit and
possible personal injury.
Drain the water tank through the drain valve at the
bottom part of the unit.
Do not use stainless steel fittings to connect directly with
other metals to prevent galvanic corrosion.
Note: A pressure releasing valve is to be fitted within the installation. Spec of P&T valve: Pressure: 0.85MP Temperature: 99°C
Water Inlet or Outlet Pipes: The specification of
the water inlet and outlet thread is BSP3/4 (internal
thread). Pipes must be heat-resistant and durable.
Piping for the P&T Valve: The spec of the valve
connecting thread is BSP3/4 (internal thread). After
installation, confirm that the drainpipe outlet is
exposed in the air. When the flexible drainpipe is
joined to the pressure relief orifice of this valve,
ensure that the flexible drainpipe is pointing
downwards and exposed in the air.
5.2 Handing & Transportation
The unit should be stored and/or transported in its shipping container in an upright position and without water charge.
For transport over short distances, and provided due care is exercised, an inclination angle of up to 30 degrees is
permitted. During transport and storage, ambient temperatures of -10 to +60 degrees Celsius are permissible.
Forklift Transportation Manual Transportation
The unit must remain mounted on the pallet
and lifted at minimal speed. Due to its top
heaviness, the unit must be secured against
tipping over and placed on a level surface.
Ensure that the maximum permissible inclination angle of 60
degrees is not exceeded. If transport in an inclined position
cannot be avoided, the unit should be left to rest at least one hour
after it has been moved into final position before operation.
info@evoheat.com.au
1300 859 933
www.evoheat.com.au
Evo150-1 Manual
Page 6
5.3 Location of Installation
The Evo150-1 is designed for external installation, however, where possible installing the unit under the house eaves
or in a sheltered environment may help prolong the life of the system.
Heat pumps operate most efficiently with warmer air temperatures, and the outlet air from the unit will always be
colder than the inlet air. Therefore, it is advisable to install the unit so it receives the warmest air temperatures
possible and that the cold air is not able to recirculate back into the unit.
5.3.1 Indoor Installation
The unit may be able to be installed in an unventilated room exceeding 25m3 in volume.
Venting of cold air is advised to prevent the air temperature dropping and lowering the efficiency of the unit.
Think of the unit as a 3kW air conditioner for the effect it will have on a closed room.
TO COOL A ROOM
TO MAINTAIN NORMAL ROOM TEMPERATURE
Install the unit so the outlet from the heat pump is
blowing INTO the room. The room MUST have some
form of air outlet otherwise the performance of the unit
will suffer significantly.
Install the unit so the outlet from the heat pump is
blowing OUTSIDE the room. The room MUST have
some form of air inlet otherwise the performance of the
unit will suffer significantly.
5.4 Airflow Clearances
The Evo150-1 must be installed with sufficient clearances to allow airflow to
circulate through the unit, it is advised to keep a minimum gap between
walls/fences etc of:
300mm on the air inlet side
500mm on the air outlet side
100mm overhead & rear clearance
Without sufficient airflow, discharged cold air will recirculate into the unit and
consequently lower the heating efficiency.
If the installation location does not comply with these suggested clearances,
contact EvoHeat’s Tech Support to discuss possible solutions.
5.5 Cable Connection 5.6 Filling the Tank
The power cable for power supply of the unit is stored in
the back of the unit
. The unit requires an isolating switch
as required by local
laws. If the power cord is damaged,
it must be replaced by a qualified electrician.
Open a hot water tap inside the house. Open the
cold-water inlet valve into the Evo150-1 to fill the
tank. When water begins flowing out of the hot water
tap inside the premises, turn off the hot water tap.
5.7 Initial Start-Up
PRE-INSPECTION
Check the water supply to the tank and pipe connections for possible
leaks.
Check that the following devices are installed and operating correctly:
Drainpipes
P&T Valve
Filter on inlet
Water softening and pressure reducing devices if required.
Check that all power connections are secure before switching on.
Check that the installation space is adequate.
TRIAL OPERATION
Switch on the unit by using the
controller.
If any unusual noises occur, switch the
power off and consult your provider.
The parameters have been pre-set to
a temperature of 60 degrees. Check
that the unit is operating by looking for
an increase in water temperature over
time.
info@evoheat.com.au
1300 859 933
www.evoheat.com.au
Evo150-1 Manual
Page 7
6. Operation
6.1 The Controller
ON/OFF Turn the unit on or off.
UP Select options to increase values
DOWN Select options to decrease values
CLOCK Set the clock or the timer.
HYDROBOOST Turn on/off the electric heater
MODE Switch unit running modes or save setting
parameters
TOUCH TIMING Touch timing settings
HEATING
MODE
The unit will start according to the water temperature and target temperature. The
electric heater will not start immediately. After 200 minutes, the unit will judge if it has
reached target temperature. If not, the electric heater will start.
ECO HEATING
MODE
The heat pump system will start according to the water temperature and target
temperature. The electric heater always will be off.
INTELLIGENT
MODE
The unit will automatically judge the operation mode according to the ambient
temperature.
HIGH
REQUIREMENT
MODE
The difference between heating mode and high requirement mode is the delay time of
electric heater. In the high demand mode, the electric heater will start without delay,
which can help the user to heat water quickly in a short time.
VACATION
MODE Enable Vacation mode
SET TEMP
REACHED
Set temperature has been reached
and the unit will shut off
automatically
FAN Fan is on
HYDROBOOST The Hydroboost setting is on
LOWER
TANK TEMP Temperature of the lower tank
DEFROST The unit is defrosting
MINUTE Minute value is being set
LOCK Keyboard is locked
SECOND Second value is being set
PARAMETER
SETTING Parameter is adjustable WI-FI State of Wi-Fi connection
*Only available as an optional upgrade
info@evoheat.com.au
1300 859 933
www.evoheat.com.au
Evo150-1 Manual
Page 8
6.2 Operating Functions
EvoHeat have developed a YouTube Channel with video
walkthroughs of the different controller
functions.
Scan the QR code or head to our channel to view the video
s we have available
https://www.youtube.com/@evoheatpumps
6.2.1 Startup & Shutdown
Press
and hold for 0.5 seconds in the
standby screen of the controller to turn the
unit on. The main display will now show the
water outlet temperature.
Press
and hold for 0.5 seconds in the
running screen of the controller to turn the
unit off. The main disp
lay will now show
“OFF”.
The unit will dim the screen and display the
standby screen when the controller has not
been touched for a minute. Touch the power
button to wake it.
Note: The ON/OFF button can only be used to turn
the unit on/off in standby or o
n the running screen
of the controller.
6.2.2 Switching Modes
We recommend running the unit in Eco Heating mode where possible for maximum energy efficiency.
From the running screen, press to select one of the modes: Heating, Eco Heating, Intelligent, High requirement,
Vacation.
6.2.3 Locking the Controller
To both lock and unlock the controller, press and hold the button for 5 seconds.
When the controller is locked, a lock symbol will appear on the bottom right.
info@evoheat.com.au
1300 859 933
www.evoheat.com.au
Evo150-1 Manual
Page 9
6.2.4 Setting & Checking the Target Temperature
In the standby or running interface, press or once to check the target temperature of the outlet water.
Press or again to change the target temperature.
After making changes to the desired temperature, press to confirm or to cancel, then return to the previous
screen.
If the keypad is left idle for 5 seconds, the controller will exit the menu automatically and apply any changes that were
made.
Example: The target temperature is 40°C, the actual outlet water temperature is 18°C.
6.2.5 Hydroboost Setting
Also known as the Electric heater, the Hydroboost setting allows higher levels of hot water to be
produced. When there are high hot water usage requirements (such as guests staying), this function may
come in useful.
The Hydroboost setting can be turned on when the unit
is in heating or in standby mode.
Press once to turn on Hydroboost on or off.
When activated, will light up on the main display.
6.2.6 Force Defrost
In the extremely unlikely circumstance of the unit icing up (for example, if the unit was installed inside with
no ventilation), this function can be applied.
When the unit is off, press and hold for 10 seconds to enable the forced defrosting function. The defrosting
symbol will light up. Press for 10 seconds again to exit the forced defrosting function.
info@evoheat.com.au
1300 859 933
www.evoheat.com.au
Evo150-1 Manual
Page 10
6.2.7 Fan/Ventilation Function
This function may come in useful if the system is installed inside and the fan settings need to be adjusted
to suit ducting or external ventilation.
The fan speed (High Speed, Low Speed or Off) can be controlled by the fan mode on the controller.
Fan mode symbols:
High Speed
Low speed
No Fan Icon: off
Note: When H02 is set to 0, there is no ventilation function.
Note: when the compressor is on, the fan will always run at high speed.
When the parameter HO2 is set to 1, press the for 2s.
Once you hear a beep you can set the ventilation mode. Press for 2s, this will change the fan speed.
Continue to press for 2s until you reach your preferred speed.
6.2.8 System Date & Time
In the standby or running interface, press once, the hour digit will flash indicating it is being altered.
Press the or to change the hour setting, then press to confirm. Repeat this to change the minute value.
info@evoheat.com.au
1300 859 933
www.evoheat.com.au
Evo150-1 Manual
Page 11
6.2.9 Setting & Cancelling Timers
Timers can be set in standard mode, economic mode, auto mode & fast heating mode. They can be set by using
buttons or using the touch timing circle. The unit will run during the lit time periods and stop in the dim areas.
Touch Method
Button Method
Press and hold for 2 seconds (the timer
display will flash)
When the timer display flashes, choose your
start-up time (A) and end time (B).
Press to save the setting and exit back
to the main interface.
Press and hold for 2 seconds (the timer display will
flash)
When the timer display flashes, choose the start-up time (C)
and end time (D) by pressing or and .
Press to save the setting and exit back to the main
interface.
Example: Setting the unit to run from 7-11am & 4pm-6pm using Touch mode.
To cancel a timer once it has been set, hold down the CLOCK button for 2 seconds until the timer display begins
flashing (as you would set the timer).
Press the POWER button while the timer is flashing to cancel it. The yellow timing periods will disappear when the
timer has been cancelled.
info@evoheat.com.au
1300 859 933
www.evoheat.com.au
Evo150-1 Manual
Page 12
6.2.10 Vacation Mode
Vacation Mode allows you to turn the unit off to conserve power for an extended period of time, and
restart operation on a date you specify. This ensures you have hot water waiting for you upon your return.
Ensure the unit is ‘OFF before setting vacation mode. The date you set in this mode will determine what date the unit
starts back up.
After selecting vacation mode, press and hold for 2 seconds, the ‘month’ value will begin to flash in the display
area. Press the UP or DOWN arrows to display the desired month, then press to confirm and move to altering the
‘day’ value.
The ‘day’ value will flash when it is selected, use the arrow keys to select your desired start day, then press to
save all changes and exit back to the main interface.
Note: Format is mm/dd
Example: The unit will start up on September the 28th.
6.2.11 Sanitech System
The Sanitech feature’s purpose is to keep the water free of bacteria such as Legionella by heating the tank
water to 70°C for one 30-minute period every week at midnight.
An instance when you may want to alter the Sanitech function is if you have solar and would prefer the
Sanitech to run during the day, for example at 12pm, rather than midnight.
If you would like to change this function, contact EvoHeat’s service department for guidance. Incorrectly
attempting to adjust these settings yourself could significantly disrupt the unit’s operation.
info@evoheat.com.au
1300 859 933
www.evoheat.com.au
Evo150-1 Manual
Page 13
7. Troubleshooting
Malfunction
Fault
Display
Reason Elimination Methods
Bottom water temp. failure P01 The water bottom temp. sensor is
open or short circuit.
Check or change the water bottom
temp. sensor
Top tank water temp.
failure P02 The water top tank temp. sensor
is open or short circuit
Check or change the water top tank
temp. sensor
Ambient temp. failure P04 The ambient temp. sensor is open
or short circuit
Check or change the ambient temp.
sensor
Coil temp. failure P05 The pipe temp. sensor is open or
short circuit Check or change the pipe temp. sensor
Refrigerant absorb temp.
failure P07 The evaporator temp. sensor is
open or short circuit
Check or change the evaporator temp.
sensor
Anti-freeze temp. failure P09 The anti-freeze temp. sensor is
open or short circuit
Check or change the anti-freeze temp.
sensor
Solar temp. failure P034 The solar temp sensor is open or
short circuit Check or change the solar temp sensor
High pressure protection E01 The exhaust pressure is high,
high pressure switch action
Check high pressure switch and cooling
return circuit
Low pressure protection E02 The suction pressure is low, low
pressure switch action
Check low pressure switch and cooling
return circuit
Water flow failure E03 No water or little water in water
system
Water, check for flow volume pump
failure
Electric-heater overheat
protection E04
Water flow volume not enough,
water system pressure difference
is small
Water, check if the flow volume system
is jammed
Anti-freeze protection E07
Water flow volume not enough,
water system pressure difference
is small
Water, check if the flow volume system
is jammed
Communication failure E08 Wired remote control with master
signal failure
Check the connection line between the
wired remote control and mother board
Winter defrost protection E09 Ambient temperature is too low
info@evoheat.com.au
1300 859 933
www.evoheat.com.au
Evo150-1 Manual
Page 14
8. Appendix
8.1 Wiring Diagram
8.2 Wi-Fi Module Connection (Optional)
Note: If you do not have a Wi-Fi module to install, simply
push the cord
entirely behind the front panel.
The optional Wi
-fi Control upgrade can be purchased to allow
you to remotely control your EvoHeat hot water heat pump from
your phone.
Newly installed units will have a small cable that protruding out
from behind the front
panel with a small waterproof cover.
If you are installing the Wi
-Fi module, simply connect the cable
of the Wi
-Fi module to the one that protrudes.
Once the Wi
-Fi module has been connected, ensure that the
connection part of the cable is placed behind the
front cover.
The module must be placed with the cord coming downwards to
protect it from water.
info@evoheat.com.au
1300 859 933
www.evoheat.com.au
Evo150-1 Manual
Page 15
8.3 Use of the P&T Valve
The P&T valve is used to prevent the temperature or pressure becoming too high inside the tank. When
the temperature or pressure reaches the set value, the valve will open automatically to force the pressure
or temperature to decrease
The handle of the safety valve should be tested once every six months to remove the calcium carbonate deposits and
guarantee there is no blockage in the device. Take care to avoid burns as the temperature of the discharging water is
very high.
Vent pipes should be thermally insulated to prevent safety risks caused by freezing pipes in winter.
P&T valve: Model: PTR-20, action temperature: 99˚C, action pressure:0.85MPa
WARNING: Failing to operate the relief valve easing gear at least once every six months may result in
the water heater exploding. Continuous leakage of water from the valve may indicate a problem with the
water heater.
8.4 Using the Overheating Protector
The overheating protector is used to turn the power off in an emergency
or with power supply issues
, preventing the water from being heated too
high.
A thermal cut
-out could indicate a possibly dangerous situation. Do not
reset the thermal cutout until the unit has been serviced by a qualified
technician. Contact EvoHeat for a service if this occurs
before
attempting to reset.
To return the unit to its normal operation status
by resetting manually:
a) To access the overheat protector, remove the front dark grey
controller panel.
b) Remove the 3 screws on the front panel and push the front
cover upwards.
c) Remove the remaining screws which cover the overheat
protector panel.
Remove the screws and open the cover
Press the red button to reset
8.5 Draining the Water Tank
1. Close the cold-water inlet valve into the Evo150-1.
2. Open a hot water tap inside the premises.
3. Undo the drain plug on the base of the unit to drain
the water from the system.
8.6 Earthing Methodology
The water from the hot water tap and the drain plug
will be hot. Be careful of burns and scalds. Wear
protective clothing.
info@evoheat.com.au
1300 859 933
www.evoheat.com.au
Evo150-1 Manual
Page 16
9. Maintenance
Your Evo150-1 will operate most efficiently if regularly inspected as part of your home maintenance schedule.
MINOR ANNUAL MAINTENANCE
It is recommended that the minor maintenance be performed every 12 months by the dwelling occupant.
The minor maintenance includes:
Operate the easing lever on the temperature pressure relief valve. It is very important you raise and lower the
lever gently. Exercise care to avoid any splashing of water, as water discharged from the drain line will be hot.
Stand clear of the drain lines point of discharge when operating the valve’s lever.
Operate the easing level on the expansion control valve (if fitted). It is very important you raise and lower the
lever gently.
Conduct a visual inspection of all plumbing and electrical connections.
Check the condensate drain line to ensure it is not blocked.
Check that air vents are not blocked or obstructed, and if necessary clean with a damp cloth or air blower.
Conduct a general external clean of the unit with a damp cloth.
MAJOR FIVE-YEAR SERVICE
It is recommended a major five (5) year service be conducted on the Evo150-1.
Warning: Servicing of a water heater must only be carried out by qualified EvoHeat personnel.
Phone EvoHeat Service on 1300 859 933 for our closest Accredited Service Agent.
Note: The five-year service and routine replacement of any components such as the anode and relief valve(s) are not
included in the EvoHeat warranty. Only genuine replacement parts should be used on this water heater.
The major service includes the following actions:
Replace the temperature limiting valve.
Replace the temperature pressure relief valve.
Inspect the anode and if required, replace the anode. If the anode is not replaced, it should be replaced within
three years of this service.
Check the heating cycle of the unit.
Visually check the unit for any potential problems.
Inspect the plumbing and electrical all connections.
Check the condensate on drain line to ensure it is not blocked.
Note: The water heater may need to be drained during this service. After the completion of the service, the water
heater will take some time to reheat the water. Depending upon the power supply connect on, hot water may not be
available until the next day.
info@evoheat.com.au
1300 859 933
www.evoheat.com.au
Evo150-1 Manual
Page 17
10. Warranty
Refer to the EvoHeat website for warranty details
Australia: https://evoheat.com.au/warranty-terms/
South East Asia: http://evoheat.com.sg/warranty/
1. Warranty terms are from date of purchase.
2. This warranty excludes any defect or injury caused by or resulting from misuse, abuse, neglect, accidental
damage, improper voltage, vermin infestation, incompetent installation, any fault not attributable to faulty
manufacture or parts, any modifications which affect the reliability or performance of the unit.
3. This warranty does not cover the following:
a. Natural Disasters (hail, lightening, flood, fire etc.)
b. Rust or damage to paintwork caused by a corrosive atmosphere
c. When serviced by an unauthorized person without the permission of Evo Industries
d. When a unit is installed by an unqualified person
e. Where a unit is incorrectly installed
f. When failure occurs due to improper or faulty installation
g. Failure due to improper maintenance (refer Operating Instructions)
h. ‘No Fault Found’ service calls where the perceived problem is explained within the operation
instructions.
i. Costs associated with delivery, handling, freighting, or damage to the product in transit.
4. If warranty service is required, you should:
a. contact Evo Industries Australia on 1300 859 933 or via our Contact page on our web site
b. provide a copy of your receipt as proof of purchase
c. have completed the online Warranty Registration Form
5. Onsite technical service is available within the normal operating area of your Evo Authorised Service Agents.
Service outside this area will incur a traveling fee.
6. Unless otherwise specified to the purchaser, the benefits conferred by this express warranty and additional to all
other conditions, warranties, rights and remedies expressed or implied by the Trade Practices Act 1974 and
similar consumer protection provisions contained in legislation of the States and Territories and all other
obligations and liabilities on the part of the manufacturer or supplier and nothing contained herein shall restrict or
modify such rights, remedies, obligations or liabilities.
EvoHeat highly recommend customers complete their warranty details online to
ensure efficient warranty claim processing.
To register your warranty, scan our QR Code or head to our website and fill in
the Warranty Registration Form: https://evoheat.com.au/warranty-registration/
REGISTER YOUR WARRANTY
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18

evoheat EVO0150-1 Hot Water Heat Pump User manual

Type
User manual

evoheat EVO0150-1 Hot Water Heat Pump can efficiently provide clean and economical hot water for your home all year round. With a 150L storage capacity, this heat pump features advanced energy-saving technology and built-in smart functions for efficient heating. It operates at a maximum temperature of 60°C and has a heating output of 1.7kW.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI