Intrigue 42

Ambiance Intrigue 42 Installation guide

  • Hello! I am an AI chatbot trained to assist you with the Ambiance Intrigue 42 Installation guide. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Front view
Intrigue®
GAS COLLECTION
Model: Intrigue®42
Ambiance® Fireplaces & Grills www.ambiance replaces.com
BTU
EFFICIENCY
VENTING GLASS
Max NG Max PG Min NG Min PG Energuide
Steady State
Type Max. Height In & Out Diameter Type Dimensions Area sq in
39,500 39,500 18,500 18,500 70.9% 75.5% Directe 50 pieds 5” & 8”
Pure vision Robax
26” x 35” 910
DIMENSIONS MINIMUM FRAMING DIMENSIONS BLOWING MANTEL SHELF CLEARANCES
Height Depth Width Height Depth Width Type PCM 9-inch shelf
34.5” 20” 40.875” 44.5” 20” 41.875”
Variable speed
150
12.5’’
Right view
Left view
3
4
1
2
"
8
7
6
m
m
6
5
8
"
6
7
6
m
m
1
0
"
5
4
m
m
3
5
1
2
"
9
0
2
m
m
4
0
7
8
"
1
0
3
8
m
m
2
1
8
"
5
4
m
m
2
7
8
"
7
3
m
m
1
6
1
8
"
4
1
0
m
m
6
1
2
"
1
6
5
m
m
23
3
16
"
589
m
m
3
3
3
8
"
8
4
8
m
m
4
4
1
2
"
1
1
3
0
m
m
4
1
4
"
1
0
8
m
m
8
5
8
"
2
1
9
m
m
30.48in
5.18in
7.80in
19.98in
20in
30-1/2in
Ambiance® Fireplaces & Grills www.ambiancereplaces.com
Framing and Clearances
Refer to vent manufacturer installation instructions to determine
vent framing dimensions.
Figure 11.1.01
41-7/8”
(1064mm)
44 -1/2”
(1130mm)
Heart
Height
Minimum
21 - 1/2” (546mm)
CLEARANCES
Top of unit face to header (cement board may be used in this area). 10’’ (254mm)
From unit left & right sides and back 1/2’’ (13mm)
To ooring 0’’ (0mm)
Unit top to ceiling 31’’ (787mm)
Side of unit face to adjacent sidewall 3’’ (76mm)
Mantel 9’’ (229mm) deep from top of replace 12-1/2’’ (318mm)
Top of replace to 1’’ (25 mm) trim 10’’ (254mm)
Intrigue®
GAS COLLECTION
Model: Intrigue® 42
Ambiance® Fireplaces & Grills www.ambiancereplaces.com
WARNING
TOP STAND-OFF BRACKETS MUST BE ASSEMBLED AND ATTACHED TO FIREPLACE. DO NOT REMOVE. STAND-OFF
BRACKETS ARE NOT LOAD BEARING
12.0 Mantel Requirements
Non-Combustible Zone:
Rigid Pipe: 1’’ (25 mm) above elbow for entire width and depth (behind header) of replace.
Flexible Venting: 1’’ (25 mm) above elbow for entire width and depth (behind header) of replace.
CLEARANCES
Top of unit face to header (cement board may be used in this area). 10’’ (254mm)
From unit left & right sides and back 1/2’’ (13mm)
To ooring 0’’ (0mm)
Unit top to ceiling 31’’ (787mm)
Side of unit face to adjacent sidewall 3’’ (76mm)
Mantel 9’’ (229mm) deep from top of replace 12-1/2’’ (318mm)
Top of replace to 1’’ (25 mm) trim 10’’ (254mm)
Figure 12.1.01
Intrigue®
GAS COLLECTION
Model: Intrigue® 42
Ambiance® Fireplaces & Grills www.ambiancereplaces.com
11.4 Typical Installation Options
IMPORTANT
The horizontal heat shield included with this replace must be installed when incorporating minimum horizontal venting.
This applies to Nat. and LP minimum horizontal venting congurations.
Horizontal vent heat shield not shown in illustrations below for clarity purposes only.
Typical Horizontal Installation
Figure 11.4.01
Typical Corner Installation
Figure 11.4.02
Typical Vertical Installation
Figure 11.4.03
Intrigue®
GAS COLLECTION
Model: Intrigue® 42
/