Honeywell SS360PT/SS460P High Sensitivity Latching Digital Hall-Effect Sensors ICs Installation guide

Type
Installation guide
Installation Instructions for the
SS360PT/SS460P High Sensitivity Latching Digital
Hall-Effect Sensor ICs with Built-in Pull-Up Resistor
Sensing and Control
Issue 1
50085570
Table 1. SS360PT/SS460P Performance Specications (At 3 Vdc to 24 Vdc supply, 20 mA load, T
A
= -40 ºC to 125 ºC [-40 ºF to
257 ºF] except where otherwise specied.)
Characteristic Condition MIn. Typ. Max. Unit
Supply voltage:
SS360PT
SS360PT
SS460P
-40 °C to 110 °C [-40 °F to 230 °F]
125 °C [257 °F]
-40 °C to 125 °C [-40 °F to 257 °F]
3
3
3
24
16
24
Vdc
Supply current
V
supply
= 3 V at 25 °C [77 °F]
3.5
6
10
mA
Vsat Gauss >55 0.6 V
Output leakage current Gauss >55 10 µA
Internal pull-up resistor 7. 5 10.0 12.5 kOhm
Rise/fall time V
supply
= 12 V at 25 °C [77 °F] 1. 5 µs
Thermal resistance:
SS360PT (SOT-23)
SS460P (at TO-92-style)
303
233
°C/W
Operate -40 °C to 125 °C [-40 °F to 257 °F] 5 30 55 Gauss
Release -40 °C to 125 °C [-40 °F to 257 °F] -55 -30 -5 Gauss
Differential -40 °C to 125 °C [-40 °F to 257 °F] 40 60 80 Gauss
Operating temperature V
supply
= 3 Vdc to 24 Vdc -40 [-40] 125 [257] °C [°F]
Storage temperature:
SS360PT
SS460P
-40 [-40]
-40 [-40]
150 [302]
165 [329]
°C [°F]
Table 2. SS360PT/SS460P Absolute Maximum Ratings
1
Characteristic MIn. Typ. Max. Unit
Supply voltage -26.0 26.0 V
Applied output voltage -0.5 26.0 V
Output current 20 mA
Magnetic ux no limit Gauss
Note 1: Absolute maximum ratings are the extreme limits that the
device will withstand without damage to the device. However, the
electrical and mechanical characteristics are not guaranteed as
the maximum limits (above recommended operating conditions)
are approached, nor will the device necessarily operate at abso-
lute maximum ratings.
NOTICE
Bipolar Hall-effect sensor ICs may have an initial output in either
the ON or OFF state if powered up with an applied magnetic
eld in the differential zone (applied magnetic eld >Brp and
<Bop). Honeywell recommends allowing 10 µs for output voltage
to stabilize after supply voltage has reached its normal operating
value.
NOTICE
The magnetic eld strength (Gauss) required to cause the switch
to change state (operate and release) will be as specied in the
magnetic characteristics. To test the switch against the specied
magnetic characteristics, the switch must be placed in a uniform
magnetic eld.
CAUTION
ELECTROSTATIC DISCHARGE DAMAGE
Ensure proper ESD precautions are followed when handling this
product.
Failure to comply with these instructions may result in
product damage.
CAUTION
IMPROPER SOLDERING
• Ensure leads are adequately supported during any
forming/shearing operation so that they are not stressed
inside the plastic case.
• Limit exposure to high temperatures.
• Do not wave solder the SS360PT.
Failure to comply with these instructions may result in
product damage.
SS360PT: Use an infrared reow process with temperatures of
245 °C [473 °F] peak for 10 s max.
SS460P: PC board wave soldering temperature is 250 °C to
260 °C [482°F to 500 °F] peak for 3 s max.
GENERAL INFORMATION
SOLDERING/ASSEMBLY
2 Honeywell Sensing and Control
SS360PT/SS460P Series
ISSUE 1 50085570
South Pole toward IC:
Output = High
N
S
North Pole toward IC:
Output = Low
S
N
SN
NS
North Pole toward IC:
Output = High
South Pole toward IC:
Output = Low
Label SideLabel Side
Figure 1. Sensor IC Block Diagram
Figure 2. Typical Magnetic Characteristics vs Ambient Temperature at
Supply Voltages
Figure 4. Magnetic Activation
Programming
Circuit
ESD
Clamp
Comparator
V
S
GND
OUT
V
REG
Hall
ESD
Clamp
Current
Sinking
Output
+
+
Amplifier
+
Rpull-up
10 kΩ
SS360PT SS460P
Figure 3. SS360PT Maximum Rated Supply
Voltage vs Temperature
Honeywell Sensing and Control 3
SS360PT/SS460P Series
ISSUE 1 50085570
Figure 5. SS360PT Mounting and Tape/Reel Dimensions (For reference only. mm/[in].)
Figure 6. SS460P Mounting Dimensions (For reference only. mm/[in].)
2,5
[0.100]
1,6
[0.062]
3X 0,3
[0.015]
0,76
[0.03]
4,1
[0.161]
2X 1,3
[0.050]
3X 0,43
[0.017]
3X 0,38
[0.015]
3.0
[0.118]
GNDVS OUT
14,61
[0.575]
1
6
1,83
[0.072]
0,46
[0.018]
NOMINAL
TO IC
SENSING
SURFACE
NOMINAL
IC CENTER
 
>@
 
>@
1,45
[0.057]
1,20
[0.047]
6
1
0,787
[0.031]
0,413
[0.016]
0,77
[0.030]
NOMINAL
TO IC
SENSING
SURFACE
3
GND
(-)
2,90
[0.114]
1
VCC
(+)
2
OUTPUT
3X 0,50
[0.20]
1,90
[0.075]
0,95
[0.037]
NOMINAL
IC CENTER
0,60
[0.024]
Tape
Reel
Honeywell Sensing and Control
1985 Douglas Drive North
Golden Valley, MN 55422
sensing.honeywell.com
50085570-1-EN
September 2013
© 2013 Honeywell International Inc. All rights reserved.
SS360PT/SS460P Series
ISSUE 1 50085570
WARRANTY
Honeywell warrants goods of its manufacture as being free of
defective materials and faulty workmanship. Honeywell’s standard
product warranty applies unless agreed to otherwise by Honeywell
in writing; please refer to your order acknowledgement or consult
your local sales office for specic warranty details. If warranted
goods are returned to Honeywell during the period of coverage,
Honeywell will repair or replace, at its option, without charge those
items it nds defective. The foregoing is buyers sole remedy
and is in lieu of all warranties, expressed or implied, including
those of merchantability and tness for a particular purpose.
In no event shall Honeywell be liable for consequential,
special, or indirect damages.
While we provide application assistance personally, through our
literature and the Honeywell web site, it is up to the customer to
determine the suitability of the product in the application.
Specications may change without notice. The information we
supply is believed to be accurate and reliable as of this printing.
However, we assume no responsibility for its use.
WARNING
PERSONAL INJURY
DO NOT USE these products as safety or emergency stop
devices or in any other application where failure of the product
could result in personal injury.
Failure to comply with these instructions could result in
death or serious injury.
SALES AND SERVICE
Honeywell serves its customers through a worldwide network
of sales offices, representatives and distributors. For application
assistance, current specications, pricing or name of the nearest
Authorized Distributor, contact your local sales office or:
E-mail: info.sc@honeywell.com
Internet: sensing.honeywell.com
Phone and Fax:
Asia Pacic +65 6355-2828
+65 6445-3033 Fax
Europe +44 (0) 1698 481481
+44 (0) 1698 481676 Fax
Latin America +1-305-805-8188
+1-305-883-8257 Fax
USA/Canada +1-800-537-6945
+1-815-235-6847
+1-815-235-6545 Fax
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

Honeywell SS360PT/SS460P High Sensitivity Latching Digital Hall-Effect Sensors ICs Installation guide

Type
Installation guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI