Table 8: LMU30CHV with Non-Ducted, Ducted and Mixed Indoor Units — Rated Cooling Combination Table.
Cooling Capacity
No. of
Indoor
Units
Indoor Unit Combination
(kBtu/h)
Room Capacity
(Btu/h)
Total Capacity Input (W)
EER SEER
IDU
1
IDU
2
IDU
3
IDU
4
Total Unit 1 Unit 2 Unit 3 Unit 4
Minimum Rated Maximum
Min. Rated Max.
Btu/h kW Btu/h kW Btu/h kW
Non-Ducted Indoor Units
Four
Units
7 7 7 7 28 7,000 7,000 7,000 7,000 16,800 4.92 28,000 8.21 33,600 9.85 1,514 2,163 3,028 12.9 21.9
7 7 7 9 30 7,000 7,000 7,000 9,000 18,000 5.28 30,000 8.79 36,000 10.55 1,617 2,310 3,234 13.0 22.0
7 7 9 9 32 6,563 6,563 8,438 8,438 18,000 5.28 30,000 8.79 36,000 10.55 1,617 2,310 3,234 13.0 22.0
7 7 7 12 33 6,364 6,364 6,364 10,909 18,000 5.28 30,000 8.79 36,000 10.55 1,617 2,310 3,234 13.0 22.0
7 9 9 9 34 6,176 7,941 7,941 7,941 18,000 5.28 30,000 8.79 36,000
10.55 1,617 2,310 3,234 13.0 22.0
7 7 9 12 35 6,000 6,000 7,714 10,286 18,000 5.28 30,000 8.79 36,000 10.55 1,617 2,310 3,234 13.0 22.0
7 7 7 15 36 5,833 5,833 5,833 12,500 18,000 5.28 30,000 8.79 36,000 10.55 1,617 2,310 3,234 13.0 22.0
9 9 9 9 36 7,500 7,500 7,500 7,500 18,000 5.28 30,000 8.79 36,000 10.55 1,617 2,310 3,234 13.0 22.0
7 9 9 12 37 5,676 7,297 7,297 9,730 18,000 5.28 30,000 8.79 36,000 10.55 1,617 2,310 3,234 13.0 22.0
7 7 9 15 38 5,526 5,526 7,105 11,842 18,000 5.28 30,000 8.79 36,000 10.55 1,617 2,310 3,234 13.0 22.0
7 7 12 12 38 5,526 5,526 9,474 9,474 18,000 5.28 30,000 8.79 36,000 10.55 1,617 2,310 3,234 13.0 22.0
7 7 7 18 39 5,385 5,385 5,385
13,846 18,000 5.28 30,000 8.79 36,000 10.55 1,617 2,310 3,234 13.0 22.0
9 9 9 12 39 6,923 6,923 6,923 9,231 18,000 5.28 30,000 8.79 36,000 10.55 1,617 2,310 3,234 13.0 22.0
7 9 9 15 40 5,250 6,750 6,750 11,250 18,000 5.28 30,000 8.79 36,000 10.55 1,617 2,310 3,234 13.0 22.0
7 9 12 12 40 5,250 6,750 9,000 9,000 18,000 5.28 30,000 8.79 36,000 10.55 1,617 2,310 3,234 13.0 22.0
Ducted Indoor Units
Two
Units
9 9 - - 18 7,809 7,809 - - 9,371 2.75 15,618 4.58 17,336 5.08 1,276 1,823 2,552 8.6 14.2
9 12 - - 21 7,809 10,412 - - 10,933 3.20 18,221 5.34 20,225 5.93 1,462 2,088 2,923 8.7 14.4
12 12 - - 24 10,412 10,412 - - 12,494 3.66 20,824 6.10 23,115 6.77 1,618 2,311 3,235 9.0
14.9
9 18 - - 27 7,809 15,618 - - 14,056 4.12 23,427 6.87 26,004 7.62 1,796 2,565 3,591 9.1 15.1
12 18 - - 30 10,412 15,618 - - 15,618 4.58 26,030 7.63 28,893 8.47 1,951 2,788 3,903 9.3 15.4
18 18 - - 36 13,700 13,700 - - 16,440 4.82 27,400 8.03 30,414 8.91 1,951 2,788 3,903 9.8 16.3
Three
Units
9 9 9 - 27 7,809 7,809 7,809 - 14,056 4.12 23,427 6.87 26,941 7.90 1,707 2,438 3,413 9.6 15.9
9 9 12 - 30 7,809 7,809 10,412 - 15,618 4.58 26,030 7.63 29,935 8.77 1,825 2,608 3,651 10.0 16.5
9 12 12 - 33 7,473 9,964 9,964 - 16,440 4.82 27,400 8.03 31,510 9.24 1,825 2,608 3,651 10.5 17.4
9 9 18 - 36 6,850 6,850 13,700 - 16,440 4.82
27,400 8.03 31,510 9.24 1,825 2,608 3,651 10.5 17.4
12 12 12 - 36 9,133 9,133 9,133 - 16,440 4.82 27,400 8.03 31,510 9.24 1,825 2,608 3,651 10.5 17.4
9 12 18 - 39 6,323 8,431 12,646 - 16,440 4.82 27,400 8.03 31,510 9.24 1,825 2,608 3,651 10.5 17.4
Four
Units
9 9 9 9 36 6,850 6,850 6,850 6,850 16,440 4.82 27,400 8.03 32,880 9.64 1,744 2,491 3,487 11.0 18.2
9 9 9 12 39 6,323 6,323 6,323 8,431 16,440 4.82 27,400 8.03 32,880 9.64 1,744 2,491 3,487 11.0 18.2
Mixed Indoor Units
Two
Units
7 9 - - 16 6,537 8,405 - - 8,965 2.63 14,941 4.38 16,585 4.86 1,094 1,563 2,188 9.6 16.1
9 9 - - 18 8,405 8,405 - - 10,085 2.96 16,809 4.93 18,658 5.47 1,230 1,757 2,460 9.6 16.1
7 12 - - 19 6,537 11,206 - - 10,646 3.12 17,743 5.20 19,695 5.77 1,287 1,839 2,574 9.6 16.2
9 12 - - 21 8,405 11,206 - - 11,766 3.45 19,611 5.75 21,768 6.38 1,409 2,012 2,817 9.7 16.4
9 15 - - 24 8,405 14,008 - - 13,447 3.94 22,412 6.57 24,877 7.29 1,559 2,227 3,118 10.1 16.9
12 12 - - 24 11,206 11,206 - - 13,447 3.94 22,412 6.57 24,877 7.29 1,559 2,227 3,118 10.1 16.9
7 18 - - 25 6,537 16,809 - - 14,008 4.11 23,346 6.84 25,914 7.59 1,616 2,309 3,232 10.1 17.0
9 18 - - 27 8,405 16,809 - - 15,128 4.43 25,214 7.39 27,987 8.20 1,730 2,472 3,461 10.2 17.2
12 15 - - 27 11,206 14,008 - - 15,128 4.43 25,214 7.39 27,987
8.20 1,730 2,472 3,461 10.2 17.2
12 18 - - 30 11,206 16,809 - - 16,809 4.93 28,015 8.21 31,097 9.11 1,881 2,686 3,761 10.4 17.6
7 24 - - 31 6,403 21,954 - - 17,015 4.99 28,358 8.31 31,477 9.23 1,881 2,686 3,761 10.6 17.8
9 24* - - 33 7,827 20,873 - - 17,220 5.05 28,700 8.41 31,857 9.34 1,881 2,686 3,761 10.7 18.0
15 18 - - 33 13,045 15,655 - - 17,220 5.05 28,700 8.41 31,857 9.34 1,881 2,686 3,761 10.7 18.0
18 18 - - 36 14,350 14,350 - - 17,220 5.05 28,700 8.41 31,857 9.34 1,881 2,686 3,761 10.7 18.0
12 24* - - 36 9,567 19,133 - - 17,220 5.05 28,700 8.41 31,857 9.34 1,881 2,686 3,761 10.7 18.0
15 24* - - 39 11,038 17,662 -
- 17,220 5.05 28,700 8.41 31,857 9.34 1,881 2,686 3,761 10.7 18.0
COMBINATION TABLES
1. Capacity as rated: 0 ft. above sea level with 25 ft. of refrigerant piping.
0 ft. level difference between outdoor and indoor units.
2. Cooling capacity rating obtained with air entering the indoor unit at 80°F dry bulb (DB) and 67°F wet bulb
(WB), and outdoor ambient conditions of 95°F dry bulb (DB) and 75°F wet bulb (WB).
3. Wiring cable size must comply with the applicable local and national codes.
4. The specification may be subject to change without prior notice for purpose of improvement.
5. At least two indoor units must be connected.
6.
Combination tables with calculated SEER and HSPF are outside the scope of AHRI 1230 test standard.
*
The indoor unit must be a non-ducted type.
Note:
FOR PROPER SYSTEM OPERATION:
1. At least two operable indoor units must be connected to the outdoor unit.
2. Total connected indoor unit nominal capacity must be a minimum 40% and a maximum of 133% of outdoor unit nominal capacity.
3. To calculate the connected total indoor unit nominal capacity, simply sum up the nominal capacities of all indoor units.
· For 24,000 and 36,000 Btu/h high static duct and vertical-horizontal air handling indoor units, a 1.3 multiplier must first be applied before adding to the sum of
other smaller indoor units.
· When high static duct and/or vertical-horizontal air handling indoor units are the only connected indoor units, the multiplier is 1.2.
MULTI ZONE
LMU30CHV
Table 9: LMU30CHV with Mixed Indoor Units — Rated Cooling Combination Table.
Cooling Capacity
No. of
Indoor
Units
Indoor Unit Combination
(kBtu/h)
Room Capacity (Btu/h) Total Capacity Input (W)
EER SEER
IDU
1
IDU
2
IDU
3
IDU
4
Total Unit 1 Unit 2 Unit 3 Unit 4
Minimum Rated Maximum
Min. Rated Max.
Btu/h kW Btu/h kW Btu/h kW
Mixed Indoor Units
Three
Units
7 7 9 - 23 6,537 6,537 8,405 - 12,887 3.78 21,478 6.29 24,700 7.24 1,473 2,104 2,946 10.2 17.2
7 9 9 - 25 6,537 8,405 8,405 - 14,008 4.11 23,346 6.84 26,848 7.87 1,587 2,268 3,175 10.3 17.3
7 7 12 - 26 6,537 6,537 11,206 - 14,568 4.27 24,280 7.12 27,922 8.18 1,616 2,309 3,232 10.5 17.7
9 9 9 - 27 8,405 8,405 8,405 - 15,128 4.43 25,214 7.39 28,996 8.50 1,645 2,349 3,289 10.7 18.1
7 9 12 - 28 6,537 8,405 11,206 - 15,688 4.60 26,147 7.66 30,069
8.81 1,680 2,400 3,361 10.9 18.3
9 9 12 - 30 8,405 8,405 11,206 - 16,809 4.93 28,015 8.21 32,217 9.44 1,759 2,513 3,518 11.1 18.8
7 9 15 - 31 6,326 8,133 13,556 - 16,809 4.93 28,015 8.21 32,217 9.44 1,759 2,513 3,518 11.1 18.8
7 12 12 - 31 6,403 10,977 10,977 - 17,015 4.99 28,358 8.31 32,611 9.56 1,759 2,513 3,518 11.3 19.0
7 7 18 - 32 6,278 6,278 16,144 - 17,220 5.05 28,700 8.41 33,005 9.67 1,759 2,513 3,518 11.4 19.2
9 9 15 - 33 7,827 7,827 13,045 - 17,220 5.05 28,700 8.41 33,005 9.67 1,759 2,513 3,518 11.4 19.2
9 12 12 - 33 7,827 10,436 10,436 - 17,220 5.05 28,700 8.41 33,005 9.67 1,759 2,513 3,518 11.4 19.2
7 9 18 - 34 5,909 7,597 15,194
- 17,220 5.05 28,700 8.41 33,005 9.67 1,759 2,513 3,518 11.4 19.2
7 12 15 - 34 5,909 10,129 12,662 - 17,220 5.05 28,700 8.41 33,005 9.67 1,759 2,513 3,518 11.4 19.2
9 9 18 - 36 7,175 7,175 14,350 - 17,220 5.05 28,700 8.41 33,005 9.67 1,759 2,513 3,518 11.4 19.2
9 12 15 - 36 7,175 9,567 11,958 - 17,220 5.05 28,700 8.41 33,005 9.67 1,759 2,513 3,518 11.4 19.2
12 12 12 - 36 9,567 9,567 9,567 - 17,220 5.05 28,700 8.41 33,005 9.67 1,759 2,513 3,518 11.4 19.2
7 12 18 - 37 5,430 9,308 13,962 - 17,220 5.05 28,700 8.41 33,005 9.67 1,759 2,513 3,518 11.4 19.2
7 7 24* - 38 5,287 5,287 18,126 - 17,220 5.05 28,700 8.41 33,005 9.67 1,759 2,513 3,518 11.4 19.2
9 12
18 - 39 6,623 8,831 13,246 - 17,220 5.05 28,700 8.41 33,005 9.67 1,759 2,513 3,518 11.4 19.2
9 15 15 - 39 6,623 11,038 11,038 - 17,220 5.05 28,700 8.41 33,005 9.67 1,759 2,513 3,518 11.4 19.2
12 12 15 - 39 8,831 8,831 11,038 - 17,220 5.05 28,700 8.41 33,005 9.67 1,759 2,513 3,518 11.4 19.2
7 9 24* - 40 5,023 6,458 17,220 - 17,220 5.05 28,700 8.41 33,005 9.67 1,759 2,513 3,518 11.4 19.2
7 15 18 - 40 5,023 10,763 12,915 - 17,220 5.05 28,700 8.41 33,005 9.67 1,759 2,513 3,518 11.4 19.2
Four
Units
7 7 7 9 30 6,537 6,537 6,537 8,405 16,809 4.93 28,015 8.21 33,618 9.85 1,680 2,400 3,361 11.7 19.6
7 7 9 9 32 6,278 6,278 8,072 8,072 17,220 5.05 28,700 8.41 34,440
10.09 1,680 2,400 3,361 12.0 20.1
7 7 7 12 33 6,088 6,088 6,088 10,436 17,220 5.05 28,700 8.41 34,440 10.09 1,680 2,400 3,361 12.0 20.1
7 9 9 9 34 5,909 7,597 7,597 7,597 17,220 5.05 28,700 8.41 34,440 10.09 1,680 2,400 3,361 12.0 20.1
7 7 9 12 35 5,740 5,740 7,380 9,840 17,220 5.05 28,700 8.41 34,440 10.09 1,680 2,400 3,361 12.0 20.1
9 9 9 9 36 7,175 7,175 7,175 7,175 17,220 5.05 28,700 8.41 34,440 10.09 1,680 2,400 3,361 12.0 20.1
7 9 9 12 37 5,430 6,981 6,981 9,308 17,220 5.05 28,700 8.41 34,440 10.09 1,680 2,400 3,361 12.0 20.1
7 7 9 15 38 5,287 5,287 6,797 11,329 17,220 5.05 28,700 8.41 34,440 10.09 1,680 2,400 3,361 12.0 20.1
7 7 12 12 38 5,287 5,287 9,063
9,063 17,220 5.05 28,700 8.41 34,440 10.09 1,680 2,400 3,361 12.0 20.1
7 7 7 18 39 5,151 5,151 5,151 13,246 17,220 5.05 28,700 8.41 34,440 10.09 1,680 2,400 3,361 12.0 20.1
9 9 9 12 39 6,623 6,623 6,623 8,831 17,220 5.05 28,700 8.41 34,440 10.09 1,680 2,400 3,361 12.0 20.1
7 9 9 15 40 5,023 6,458 6,458 10,763 17,220 5.05 28,700 8.41 34,440 10.09 1,680 2,400 3,361 12.0 20.1
7 9 12 12 40 5,023 6,458 8,610 8,610 17,220 5.05 28,700 8.41 34,440 10.09 1,680 2,400 3,361 12.0 20.1
COMBINATION TABLES
1. Capacity as rated: 0 ft. above sea level with 25 ft. of refrigerant piping.
0 ft. level difference between outdoor and indoor units.
2. Cooling capacity rating obtained with air entering the indoor unit at 80°F dry bulb (DB) and 67°F wet bulb
(WB), and outdoor ambient conditions of 95°F dry bulb (DB) and 75°F wet bulb (WB).
3. Wiring cable size must comply with the applicable local and national codes.
4. The specification may be subject to change without prior notice for purpose of improvement.
5. At least two indoor units must be connected.
6.
Combination tables with calculated SEER and HSPF are outside the scope of AHRI 1230 test standard.
*The indoor unit must be a non-ducted type.
Note:
FOR PROPER SYSTEM OPERATION:
1. At least two operable indoor units must be connected to the outdoor unit.
2. Total connected indoor unit nominal capacity must be a minimum 40% and a maximum of 133% of outdoor unit nominal capacity.
3. To calculate the connected total indoor unit nominal capacity, simply sum up the nominal capacities of all indoor units.
· For 24,000 and 36,000 Btu/h high static duct and vertical-horizontal air handling indoor units, a 1.3 multiplier must first be applied before adding to the sum of
other smaller indoor units.
· When high static duct and/or vertical-horizontal air handling indoor units are the only connected indoor units, the multiplier is 1.2.