GE AKCQ08ACA Owner's manual

Type
Owner's manual
Write the model and serial
numbers here:
Model # _________________
Serial # _________________
You can find the rating label on the
side of the air conditioner.
GE is a trademark of the General Electric Company. Manufactured under trademark license.
OWNER’S MANUAL
AIR CONDITIONER
ROOM
49-7845 Rev. 0 08-18 GEA
SAFETY INFORMATION .........3
USING THE AIR CONDITIONER
Controls ..............................4
Starting the Air Conditioner .............5
Using the Remote Control ..............6
Air Direction ..........................7
CARE AND CLEANING
Grille and Case ........................7
Air Filter ..............................7
Annual Maintenance ....................7
INSTALLATION INSTRUCTIONS
Before You Begin ......................8
Electrical Requirements ................8
Tools You will Need ....................8
Installation Requirements ...............8
Parts Included .........................9
Installing the Air Conditioner ...........10
TROUBLESHOOTING
Normal Operating Sounds ............. 11
Troubleshooting Tips ..................12
LIMITED WARRANTY ...........13
CONSUMER SUPPORT ..........14
AKCQ08ACA
AKCQ10ACA
AKCQ10DCA
AKCQ12ACA
AKCQ12DCA
ENGLISH/FRANÇAIS/
ESPAÑOL
2 49-7845 Rev. 0
THANK YOU FOR MAKING GE APPLIANCES A PART OF YOUR HOME.
Whether you grew up with GE Appliances, or this is your first, we’re happy to have you in the family.
We take pride in the craftsmanship, innovation and design that goes into every GE Appliances
product, and we think you will too. Among other things, registration of your appliance ensures that we
can deliver important product information and warranty details when you need them.
Register your GE appliance now online. Helpful websites and phone numbers are available in the
Consumer Support section of this Owner’s Manual.
49-7845 Rev. 0 3
SAFETY INFORMATION
IMPORTANT SAFETY INFORMATION
READ ALL INSTRUCTIONS BEFORE USING THE APPLIANCE
For your safety, the information in this manual must be followed to minimize the risk of
fire, electric shock or personal injury.
Use this appliance only for its intended purpose as
described in this Owner’s Manual.
This air conditioner must be properly installed in accordance
with the Installation Instructions before it is used.
Never unplug your air conditioner by pulling on the
power cord. Always grip plug firmly and pull straight
out from the receptacle.
Replace immediately all electric service cords that
have become frayed or otherwise damaged. A
damaged power supply cord must be replaced with a
new power supply cord obtained from the manufacturer
and not repaired. Do not use a cord that shows cracks
or abrasion damage along its length or at either the
plug or connector end.
Turn the unit OFF and unplug your air conditioner
before cleaning.
To avoid risk of injury or property damage, the air
conditioner should only be serviced by a qualified
servicer, who should hold a current valid certificate
from an industry-accedited assessment authority,
which authorizes their competence to handle
refrigerants safely in accordance with an industry
recognized assessment specification.
For your safety…do not store or use combustible
materials, gasoline or other flammable vapors or
liquids in the vicinity of this or any other appliance.
All air conditioners contain refrigerants, which under federal
law must be removed prior to product disposal. If you are
getting rid of an old product with refrigerants, check with
the company handling disposal about what to do.
If the receptacle does not match the plug, the receptacle
must be changed out by a qualified electrician.
These R410A air conditioning systems require
contractors and technicians to use tools, equipment
and safety standards approved for use with this
refrigerant. DO NOT use equipment certified for R22
refrigerant only.
WARNING
USE OF EXTENSION CORDS
RISK OF FIRE. Could cause serious injury or death.
DO NOT use an extension cord with this Built-In Air
Conditioner.
DO NOT use surge protectors or multi-outlet adaptors
with this Built-In Air Conditioner.
HOW TO CONNECT ELECTRICITY
Do not, under any circumstances, cut or remove the third
(ground) prong from the power cord. For personal safety,
this appliance must be properly grounded.
DO NOT use an adapter plug with this appliance.
The power cord of this appliance is equipped with a
3-prong (grounding) plug which mates with a standard
3-prong (grounding) wall outlet to minimize the possibility
of electric shock hazard from this appliance.
Power cord includes a current interrupter device. A test
and reset button is provided on the plug case. The device
should be tested on a periodic basis by first pressing the
TEST button and then the RESET button while plugged
into the outlet. If the TEST button does not trip or if the
RESET button will not stay engaged, discontinue use of the
air conditioner and contact a qualified service technician.
Have the wall outlet and circuit checked by a qualified
electrician to make sure the outlet is properly grounded.
Where a 2-prong wall outlet is encountered, it is your
personal responsibility and obligation to have it replaced
with a properly grounded 3-prong wall outlet.
The air conditioner should always be plugged into its
own individual electrical outlet which has a voltage rating
that matches the rating plate.
This provides the best performance and also prevents
overloading house wiring circuits which could cause a
fire hazard from overheated wires.
See the Installation Instructions, Electrical
Requirements section for specific electrical connection
requirements.
WARNING
WARNING
Chemical Burn Hazard. Keep batteries away from children.
This product contains a lithium button/coin cell battery.
If a new or used lithium button/coin cell battery is
swallowed or enters the body, it can cause severe
internal burns and can lead to death in as little
as 2 hours. Always completely secure the battery
compartment. If the battery compartment does not
close securely, stop using the product, remove the
batteries, and keep it away from children.
If you think batteries might have been swallowed or
placed inside any part of the body, seek immediate
medical attention.
The cells shall be disposed of properly, including
keeping them away from children.
Even used cells may cause injury.
READ AND SAVE THESE INSTRUCTIONS
4 49-7845 Rev. 0
USING THE AIR CONDITIONER
Controls
Controls
1. Power Pad
Turns air conditioner on and off. When turned on,
the display will show the room temperature.
2. Display
Shows the room temperature or time remaining on
the Delay timer. Shows the Set temperature while
setting the temperature in Cool or Eco modes.
3. Temp and Delay Increase + /Decrease Pads
Use to set temperature or delay time. Temperature
can be set in Cool and Eco mode.
4. Mode Pad
Use to set the air conditioner to Fan, Energy Save,
Cool or Dehum mode.
5. Fan Speed Pad
Use to set the fan speed to High, Med, or Low
on the unit.
6. Timer
Use to set the air conditioner to turn on or off
automatically.
7. Filter Reset Pad
This feature automatically notifies you that the air
filter must be cleaned.
Features and appearance will vary.
Lights below the touch pads on the air conditioner control panel indicate the selected settings.
Unit power
on/off
Mode select
Fan speed
Delay 1–24hr
Temperature
set/Delay
Timer Increase
and Decrease
Air Conditioner Controls Remote Control
1
2 34 5
6
7
ON/OFF
MODE
SPEED
DELAY
TEMP/TIME
TEMP/TIME
49-7845 Rev. 0 5
Operating your air conditioner properly helps you to obtain
the best possible results. This section explains how to
operate this air conditioner.
IMPORTANT:
When you turn off the air conditioner , either at the control
panel or with the remote control, wait at least 3 minutes
before turning it back on. This prevents the compressor
from overloading. This 3 minute delay also applies when
switching from cool mode to fan and back.
Do not operate your air conditioner in the Cool mode
when the outside temperature is below 61°F (16° C).
The inside evaporator coil will freeze up, and the air
conditioner will not operate properly.
Using the Air Conditioner
USING THE AIR CONDITIONER
Starting the Air Conditioner
1. Carefully remove the clear plastic film from the control
panel.
2. Press POWER once to turn on the air conditioner.
NOTE: When the air conditioner is first plugged in, the
LED display will show “88” for 3 seconds.
After the air conditioner is turned on for the first time,
the display will show the temperature 72 F and the
fan is automatically set to Low speed and the Mode
indicator will show ECO.
NOTE: To switch the temperature display between
Fahrenheit (F) and Celsius(C), the air conditioner
must be plugged in, and turned ON. On the control
panel on the front of the AC, press the UP and DOWN
button at the same time and hold for 3 seconds. The
change cannot be done using the remote control.
3. Select Mode. Refer to “Mode.”
4. Select Speed. Refer to “Speed.”
5. Set Timer. Refer to “Temp/Time.”
6. Reset the filter. Refer to “Filter Reset.”
MODE
1. Press mode until you see the indicator light come on
next to the desired setting.
2. Choose Fan, Eco, Cool, or Dehum.
FAN - Only the fan runs. Press SPEED to select High,
Med or Low fan speed. The display shows the current
room temperature.
ECO - In this mode the fan runs only when cooling
is needed. The fan will run for 3 minutes after the
compressor shuts off. The fan then cycles on for 2
minutes at 10 minute intervals until the temperature
in the room is above the set temperature. The
compressor then turns back on.
COOL - Cools the room. Press SPEED to select High,
Med, Low Fan speed. Press the TEMP/TIME up or
down arrow button to adjust the temperature.
DEHUM - Aids in removing humidity from the room.
This setting will NOT cool the room. NOTE: Dehum
mode cannot be used to cool the room.
SPEED
1. Press FAN SPEED until you see the indicator light
come on next to the desired setting.
2. Choose High, Med, Low
HIGH - For maximum cooling
MED - For normal cooling
LOW - For minimum cooling
TIMER
To set the air conditioner to turn off between 1 hour and
24 hours (The air conditioner must be ON to set):
1. Press TIMER. Timer Off indicator light will be on. The
display will show the remaining hours before the air
conditioner will turn off.
2. Press the TEMP/TIME up or down arrow button to
change the delay time from 1 hour to 24 hours.
3. After 5 seconds, Timer Off indicator light will remain
on. The display will show the remaining time to Timer
Off.
To set the air conditioner to turn on between 1 hour and
24 hours:
1. Press TIMER. Timer On indicator light will be on. The
display will show the remaining hours before the air
conditioner will turn on.
2. Press the TEMP/TIME up or down arrow button to
change the delay time from 1 hour to 24 hours.
3. After 5 seconds, Timer On indicator light will remain
on. The display will show the remaining time to Timer
On.
To clear timer program:
NOTE: Air conditioner can be either on or off.
Press TIMER until Timer indicator light turns off.
To view or change the remaining time (in hours):
TIMER OFF
1. Press the TEMP/TIME up or down arrow button to
increase or decrease the time.
2. After 5 seconds, the display will show the remaining
time to Timer OFF.
TIMER ON
1. The display will show the remaining time.
2. Press the TEMP/TIME up or down arrow button to
increase or decrease the time.
3. After 5 seconds, the display will show the remaining
time to Timer ON.
6 49-7845 Rev. 0
Using the Air Conditioner
Starting the Air Conditioner (Cont.)
TEMP/TIME
1. Press the TEMP/TIME up arrow button to raise the
temperature. Each time you press the TEMP/TIME up
arrow button, the temperature will go up 1°F until it
reaches 86°F (30°C).
2. Press the TEMP/TIME down arrow button to lower the
temperature. Each time you press the TEMP/TIME
down arrow button, the temperature will go down 1°F
until it reaches 61°F (16°C).
NOTE: After 5 seconds, under Fan mode, the display
will show the current temperature. Under Cool, Eco or
Dehum mode, the display will show the set temperature.
FILTER RESET
This feature automatically notifies you that the air filter
must be cleaned. The indicator light will come on after
240 hours of operation. Clean the air filter (refer to Care
and Cleaning), place it back in the front panel, and press
the Filter Reset button. The light will turn off.
USING THE AIR CONDITIONER
Using the Remote Control
NOTE: The raised dots are Braille for the
visually impaired.
Remote control may differ in appearance
from the image shown.
NOTE: Remove and discard protective film
prior to use. The remote control runs on
one CR2025 battery (included). Replace
battery after 6 months of use, or when the
remote control starts to lose power. To
change battery, remove screw on back
panel of remote to remove cover.
POWER
Press ON/OFF to turn on the air
conditioner.
Mode
Press MODE to choose Fan, Eco, Cool or Dehum.
Speed
Press SPEED to choose High, Med, Low.
TIMER
To set the air conditioner to turn off after a set amount
between 1 hour and 24 hours (unit must be ON):
1. Press TIMER. Timer OFF indicator light on the air
conditioner control panel will be on.
2. Press the TEMP/TIME up or down arrow button to
change the delay time from 1 hour to 24 hours.
3. After 5 seconds, Timer OFF indicator light on the air
conditioner control panel will remain on.
TO SET THE AIR CONDITIONER TO TURN ON
BETWEEN 1 HOUR AND 24 HOURS:
1. Press TIMER. Timer On indicator light on the air
conditioner control panel will be on.
2. Press the TEMP/TIME up or down arrow button to
change the delay time from 1 hour to 24 hours.
3. After 5 seconds, Timer On indicator light on the air
conditioner control panel will remain on.
TO CLEAR TIMER PROGRAM:
NOTE: Air conditioner can be either on or off.
Press TIMER until Timer indicator light turns off.
TO VIEW OR CHANGE THE REMAINING TIME (IN
HOURS):
TIMER OFF
1. Press the TEMP/TIME up or down arrow button to
increase or decrease the time.
2. After 5 seconds, the display will show the remaining
time to Timer OFF.
TIMER ON
1. The display will show the remaining time.
2. Press the TEMP/TIME up or down arrow button to
increase or decrease the time.
TEMP/TIME
1. Press the TEMP/TIME up arrow button to raise the
temperature. Each time you press the TEMP/TIME up
arrow button, the temperature will go up 1°F until it
reaches 86°F (30°C).
2. Press the TEMP/TIME down arrow button to lower the
temperature. Each time you press the TEMP/TIME
down arrow button, the temperature will go down 1°F
until it reaches 61°F (16°C).
ON/OFF
MODE
SPEED
DELAY
TEMP/TIME
TEMP/TIME
49-7845 Rev. 0 7
USING THE AIR CONDITIONER / CARE AND CLEANING
Using the Air Conditioner
Air Direction
Use the lever to adjust the air direction left, right, up and
down.
Care and Cleaning
Grille and Case
Turn the air conditioner off and remove the plug from the
wall outlet before cleaning.
To clean, use water and a mild detergent. Do not use
bleach or abrasives.
Annual Maintenance
Your air conditioner needs annual maintenance to help
ensure steady, top performance throughout the year.
Call your local authorized dealer to schedule an annual
checkup. The expense of an annual inspection is your
responsibility.
Air Filter
The air filter behind the front grille should be checked
and cleaned at least every 2 weeks or more often if
necessary.
CAUTION
DO NOT operate the air conditioner
without a filter because dirt and lint will clog it and
reduce performance.
Cleaning the Air Filter
1. Turn off the air conditioner.
2. Remove the air filter by pulling the front panel to open
and removing the air filter.
3. Use a vacuum cleaner to clean air filter. If the air
filter is very dirty, wash it in warm water with a mild
detergent. Do not wash the air filter in the dishwasher
or use any chemical cleaners. Air dry the air filter
completely before replacing to ensure maximum
efficiency.
4. Replace the air filter.
5. Close the front panel.
6. Turn on the air conditioner.
Cleaning the Front Panel
1. Turn off the air conditioner.
2. Clean the front panel with a soft, damp cloth.
3. Air dry the front panel completely.
4. Turn on the air conditioner.
Air Filter
Front Panel
8 49-7845 Rev. 0
Installation Instructions
BEFORE YOU BEGIN
Read these instructions completely and carefully.
IMPORTANT – Save these
instructions for local inspector’s use.
IMPORTANT – Observe all governing
codes and ordinances.
Note to Installer – Be sure to leave these
instructions with the Consumer.
Note to Consumer – Keep these instructions for
future reference.
Skill level – Installation of this appliance requires
basic mechanical skills.
Completion time Approximately 1 hour
We recommend that two people install this product.
Proper installation is the responsibility of the
installer.
Product failure due to improper installation is not
covered under the Warranty.
You MUST use all supplied parts and use proper
installation procedures as described in these
instructions when installing this air conditioner.
Questions? Call 800.GE.CARES (800.432.2737) or Visit our Website at: GEAppliances.com
ELECTRICAL REQUIREMENTS
These models require a 115/120-volt AC or a
230-volt AC, 60-Hz grounded outlet protected
with a 15-amp time-delay fuse or circuit
breaker.
The 3-prong grounding plug minimizes the possibility
of electric shock hazard. If the wall outlet you plan to
use is only a 2-prong outlet, it is your responsibility to
have it replaced with a properly grounded 3-prong wall
outlet.
Power cord includes a current interrupter device. A
test and reset button is provided on the plug case. The
device should be tested on a periodic basis by first
pressing the TEST button and then the RESET button
while plugged into the outlet. If the TEST button does
not trip or if the RESET button will not stay engaged,
discontinue use of the air conditioner and contact a
qualified service technician.
INSTALLATION REQUIREMENTS
For new construction, install the Haier Wall Sleeve
HTTWSB.
Remove old air conditioner and inspect sleeve for
the following:
Installation - Make sure that sleeve is securely
installed and in sound structural condition.
Dimensions - Measure the size to make sure the air
conditioner will fit.
Slope - Ensure wall sleeve is level or has a rearward
slope for condensate to drain from the unit.
If pre-existing wall sleeve is suspect, it is
recommended to install Haier Wall Sleeve, model
HTTWSB, in its place.
TOOLS YOU WILL NEED
Phillips head screwdriver
Ruler or tape measure
Pencil
Level
Scissors or knife
Drill and 1/8” drill bit
CAUTION
Do not, under any circumstances, cut or remove
the third (ground) prong from the power cord.
Do not change the plug on the power cord of this
air conditioner.
Aluminum house wiring may present special
problems—consult a qualified electrician.
CAUTION
There are sharp edges that can cause serious cuts.
When lifting the air conditioner, it is HEAVY. Use 2
peoples to lift.
INSTALLATION INSTRUCTIONS
REAR
Wall Sleeve
UNIT
LEVEL
FRONT
to
ARRIÈRE
Compartiment mural
APPAREIL
NIVEAU
AVANT
1/4 po à 5/16 po
PARTE
TRASERA
Forro para pared
UNIDAD
NIVEL
PARTE
FRONTAL
a
49-7845 Rev. 0 9
INSTALLATION INSTRUCTIONS
Installation Instructions
Check the contents of the accessories supplied with your air conditioner as shown below:
7
5
10
2
1
3
4
6
8
9
Number Part name QTY.
1 Wide Top/Bottom Trim Frame 2
2 Wide Side Trim Frame 2
3 Narrow Top/Bottom Trim Frame 2
4 Narrow Side Trim Frame 2
5 Foam Seal 1
6 Universal Fit Rear Grille 1
7 Rubber Clamp 4
8 Tapered Spacer Block 2
9 Board 1
10 Retaining Bracket 1
10 49-7845 Rev. 0
Installing the Air Conditioner
1. Identify the existing wall sleeve before installing
the unit from the list below:
NOTE: All wall sleeves used to mount the new Air
Conditioner must be in sound structural condition
and have a rear grille that securely attaches to
sleeve,or rear flange that serves as a stop for the
Air conditioner.
2. Clean the interior of the sleeve (do not disturb
seals).
3. Repaint the sleeve if needed.
4. For best performance and energy efficiency,
replace the existing rear louver grille with the
plastic mesh supplied in the package. Measure
and cut the plastic grille to fit and place inside
the wall sleeve against the rear flange.
Installing the Air Conditioner (Cont.)
If your existing sleeve has a rear grille and you
wish to retain: redirect the louvers to 60 angle
as shown below.
5. If the depth of your existing wall sleeve is less
than or equal to 20”,skip to step 7. Otherwise,
cut the baffles and the support blocks according
to length “A” in the table below.
6. Remove the backing from the support blocks
and attach them to the inside of the wall sleeve
as shown below. Slide the baffle into slots of the
support blocks.
7. Install unit into the wall sleeve, leaving enough
of the unit exposed to access bracket location.
8. Install retaining bracket at front left corner by
removing and reusing screw. Push unit fully into
sleeve
Brand
Wall Sleeve Dimensions
Width Height Depth
Haier Amana 25-13/32” 15-3/4” 17-1/2”
Haier Amana 25-7/8” 15-9/16” 16-3/4”
White-
Westinghouse
Frigidare Carrier
(52F series)
25-1/2” 15-1/4” 16, 17-1/2”
or 22
GE Appliances/
Hotpoint
26” 15-5/8” 16-7/8”
Whirlpool 25-7/8” 16-1/2” 17-1/8”
Sears/Kenmore 25-7/8” 15-17/32” 16-23/32”
Carrier (51S
series)
25-3/4” 16-7/8” 18-5/8”
LG 25-7/8” 15-17/32” 16-23/32”
Plastic
Clamp
Plastic
Clamp
Plastic
Clamp
Plastic
Clamp
Serrage
En Caoutchouc
Serrage
En Caoutchouc
Serrage
En Caoutchouc
Serrage
En Caoutchouc
Abrazadera
de Goma
Abrazadera
de Goma
Abrazadera
de Goma
Abrazadera
de Goma
Pales arrieres
Rejillas traseras
Vista desde arriba
A
A
Depth “D” of the
existing wall sleeve
(inches)
Length “A”
(inches)
20 < D ≤ 20-5/8” 3/4
20-5/8 < D ≤ 21-3/4 1-3/4
21-3/4 < D ≤ 24 4
Tapered Spacer
Block Board
FRONT
Wall
Sleeve
Wall
Tapered Spacer
Block
6
1
2
Plaque de bloc
d'espacement
en biseau
AVANT
Compartiment
Mural
Bloc d'espacement
en biseau
6
1
2
po
Tablilla del bloque
espaciador cónico
FRONTAL
Forro aislante
pared
Pared
Bloque espaciador
cónico
6
1
2
Installation Instructions
INSTALLATION INSTRUCTIONS
Retaining
Bracket
Screw
49-7845 Rev. 0 11
Installing the Air Conditioner (Cont.)
9. Install the 1” x 1-1/2” x 84” long stuffer seal
between the wall sleeve and the unit.
10. To assemble trim, snap the tab of each piece
into the slot of the other piece as shown below.
Two different trim frames are supplied with unit.
Use the trim frame that best fits your sleeve.
Slide trim over the front of the air conditioner
until trim is flush with sleeve as shown below.
NOTE: Be sure to route the cord through the trim
frame before placing the trim frame on the unit. Do
not trap the cord between the trim frame and the
wall.
Installation Instructions
Assemble Trim
Ensamblar moldura
Assembler la garniture
Normal Operating Sounds
When your air conditioner is operating normally, you may hear sounds such as:
Droplets of water hitting the condenser, causing a pinging or clicking sound. The water droplets help cool the
condenser.
Air movement from the fan.
Clicks from the thermostat cycle.
Vibrations or noise due to poor wall or window construction.
A high-pitched hum or pulsating noise caused by the modern high-efficiency compressor cycling on and off.
INSTALLATION INSTRUCTIONS / TROUBLESHOOTING
12 49-7845 Rev. 0
Troubleshooting Tips... Before you call for service
Save time and money! Review the charts on the following pages first and you may not need to call for service.
Problem Possible Cause What To Do
Air conditioner
does not operate.
The unit is unplugged. Plug into a grounded 3 prong outlet. See “Electrical
Requirements.”
The power supply cord has tripped
(Reset button has popped out).
Press and release RESET (listen for click; Reset button will latch and
on some devices, a green light will turn on) to resume operation.
A household fuse has blown, or circuit
breaker has tripped.
Replace the fuse or reset the circuit breaker. If the problem
continues, call an electrician. See “Electrical Requirements.”
The Power button has not been pressed
or the Mode control knob is turned to Off.
Press POWER or turn the Mode control knob to an active
setting.
The local power has failed. Wait for power to be restored.
Air conditioner
blows fuses
or trips circuit
breakers
Too many appliances are being used on
the same circuit.
Unplug or relocate appliances that share the same circuit.
Time-delay fuse or circuit breaker of the
wrong capacity is being used.
Replace with a time-delay fuse or circuit breaker of the correct
capacity. See “Electrical Requirements.”
An extension cord is being used. Do not use an extension cord with this or any other appliance.
You are trying to restart the air
conditioner too soon after turning off the
air conditioner.
Wait at least 3 minutes after turning off the air conditioner before
trying to restart the air conditioner.
Air conditioner
power supply cord
trips (Reset button
pops out)
Disturbances in your electrical current
can trip (Reset button will pop out) the
power supply cord.
Press and release RESET (listen for click; Reset button will
latch and on some devices, a green light will turn on) to resume
operation.
Electrical overloading, overheating, cord
pinching or aging can trip (Reset button
will pop out) the power supply cord.
After correcting the problem, press and release RESET (listen
for click; Reset button will latch and on some devices, a green
light will turn on) to resume operation.
NOTE: A damaged power supply cord must be replaced with a
new power supply cord obtained from the product manufacturer
and must not be repaired.
Air conditioner
seems to run too
much
The current air conditioner replaced an
older model.
The use of more efficient components may cause the air
conditioner to run longer than an older model, but the total
energy consumption will be less. Newer air conditioners do not
emit the “blast” of cold air you may be accustomed to from older
air conditioners, but this is not an indication of lesser cooling
capacity or efficiency. Refer to the efficiency rating (EER) and
capacity rating (in Btu/h) marked on the air conditioner.
The air conditioner is in a heavily
occupied room, or heat-producing
appliances are in use in the room.
Use exhaust vent fans while cooking or bathing and try not to
use heatproducing appliances during the hottest part of the day.
A higher capacity air conditioner may be required, depending on
the size of the room being cooled.
Air conditioner
cycles on and off
too much or does
not cool room in
cooling mode
The air conditioner is not properly sized
for your room.
Check the cooling capabilities of your room air conditioner.
Room air conditioners are not designed to cool multiple rooms.
The filter is dirty or obstructed by debris.
Clean the filter.
There is excessive heat or moisture
(open container cooking, showers, etc.)
in the room.
Use a fan to exhaust heat or moisture from the room. Try not to
use heat-producing appliances during the hottest part of the day.
The louvers are blocked. Install the air conditioner in a location where the louvers are free
from curtains, blinds, furniture, etc.
The outside temperature is below 65°F
(18°C).
Do not try to operate your air conditioner in the cooling mode
when the outside temperature is below 65°F (18°C).
The temperature of the room you are
trying to cool is extremely hot.
Allow extra time for the air conditioner to cool off a very hot
room.
Windows or doors to the outside are open.
Close all windows and doors.
The Temperature control is not at a cool
enough setting.
Adjust the TEMP/TIME control to a cooler setting by pressing
the minus button to reduce the temperature. Set the Fan Speed
control to the highest setting.
Water drips from
cabinet into your
house
The air conditioner is not properly
leveled.
The air conditioner should slope slightly downward toward
the outside. Level the air conditioner to provide a downward
slope toward the outside to ensure proper drainage. See the
Installation Instructions.
NOTE: Do not drill a hole into the bottom of the metal base and
condensate pan.
TROUBLESHOOTING
49-7845 Rev. 0 13
LIMITED WARRANTY
GE Appliances Air Conditioner Limited Warranty
Service trips to your home to teach you how to use
the product.
Improper installation, delivery or maintenance. If you
have an installation problem, or if the air conditioner
is of improper cooling capacity for the intended use,
contact your dealer or installer. You are responsible
for providing adequate electrical connecting facilities.
Failure of the product resulting from modifications
to the product or due to unreasonable use including
failure to provide reasonable and necessary
maintenance.
In commercial locations, labor necessary to move the
unit to a location where it is accessible for service by
an individual technician.
Replacement of house fuses or resetting of circuit
breakers.
Failure due to corrosion on models not corrosion-
protected.
Damage to the product caused by improper power
supply voltage, accident, fire, floods or acts of God.
Incidental or consequential damage caused by
possible defects with this air conditioner.
Damage caused after delivery.
What GE Appliances Will Not Cover:
This limited warranty is extended to the original purchaser and any succeeding owner for products purchased
for home use within the USA. If the product is located in an area where service by a GE Appliances Authorized
Servicer is not available, you may be responsible for a trip charge or you may be required to bring the product to an
Authorized GE Service location for service. In Alaska, the limited warranty excludes the cost of shipping or service
calls to your home.
Some states do not allow the exclusion or limitation of incidental or consequential damages. This limited warranty
gives you specific legal rights, and you may also have other rights which vary from state to state. To know what your
legal rights are, consult your local or state consumer affairs office or your state’s Attorney General.
Warrantor: GE Appliances, a Haier company
Louisville, KY 40225
All warranty service must be provided by our Factory Service Centers, or an authorized Customer Care
®
technician.
To schedule service, visit us on-line at GEAppliances.com/service, or call 800.GE.CARES (800.432.2737). Have
serial number and model number available when calling for service.
EXCLUSION OF IMPLIED WARRANTIES—Your sole and exclusive remedy is product repair as provided in this
Limited Warranty. Any implied warranties, including the implied warranties of merchantability or fitness for a
particular purpose, are limited to two years or the shortest period allowed by law.
For The Period Of: GE Appliances Will Replace:
Two Years
From the date of the
original purchase
Any part of the air conditioner which fails due to a defect in materials or workmanship.
During this limited two-year warranty, GE Appliances will also provide, free of charge, all
labor and related service to replace the defective part.
Staple your receipt here. Proof of the original purchase
date is needed to obtain service under the warranty.
14 49-7845 Rev. 0
Printed in China
Consumer Support
CONSUMER SUPPORT
GE Appliances Website
Have a question or need assistance with your appliance? Try the GE Appliances Website 24 hours a day, any day
of the year! You can also shop for more great GE Appliances products and take advantage of all our on-line support
services designed for your convenience. In the US: GEAppliances.com
Register Your Appliance
Register your new appliance on-line at your convenience! Timely product registration will allow for enhanced
communication and prompt service under the terms of your warranty, should the need arise. You may also mail in
the pre-printed registration card included in the packing material. In the US: GEAppliances.com/register
Schedule Service
Expert GE Appliances repair service is only one step away from your door. Get on-line and schedule your service at
your convenience any day of the year. In the US: GEAppliances.com/service or call 800.432.2737 during normal
business hours.
Extended Warranties
Purchase a GE Appliances extended warranty and learn about special discounts that are available while your
warranty is still in effect. You can purchase it on-line anytime. GE Appliances Services will still be there after your
warranty expires. In the US: GEAppliances.com/extended-warranty or call 800.626.2224 during normal
business hours.
Remote Connectivity
For assistance with wireless network connectivity (for models with remote enable),
visit our website at GEAppliances.com/connected-home-smart-appliances or call 800.220.6899 in the US.
Parts and Accessories
Individuals qualified to service their own appliances can have parts or accessories sent directly to their homes
(VISA, MasterCard and Discover cards are accepted). Order on-line today 24 hours every day.
In the US: GEApplianceparts.com or by phone at 877.959.8688 during normal business hours.
Instructions contained in this manual cover procedures to be performed by any user. Other servicing
generally should be referred to qualified service personnel. Caution must be exercised, since improper
servicing may cause unsafe operation.
Contact Us
If you are not satisfied with the service you receive from GE Appliances, contact us on our Website with all the
details including your phone number, or write to:
General Manager, Customer Relations | GE Appliances, Appliance Park | Louisville, KY 40225
GEAppliances.com/contact
49-7845 Rev. 0 9
INSTRUCCIONES DE INSTALACIÓN
Instrucciones de instalación
Número Nombre de la parte CANT.
1 Moldura ancha uperior/inferior 2
2 Moldura ancha lateral 2
3 Moldura estrecha superior/inferior 2
4 Moldura estrecha lateral 2
5 Cinta de espuma 1
6 Rejilla posterior de ajuste universal 1
7 Abrazadera De Goma 4
8 Bloque espaciador cónico 2
9 Placa 1
10 Soporte de Retención 1
7
5
10
2
1
3
4
6
8
9
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44

GE AKCQ08ACA Owner's manual

Type
Owner's manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI