Greenlee H8508 / 48901 Impact Wrench Trigger Spool Kit User manual

Type
User manual
35887
LOAD CELL
Read and understand this material before operating
or servicing this equipment. Failure to understand how
to safely operate this tool could result in an accident
causing serious injury or death.
INSTRUCTION MANUAL
999 9983.8 © 1997 Greenlee Textron IM 1092 REV 2 9/97
500
5000
1000
12 TON/14 TON
TOOL LOAD CELL
PROPER PRESSURE
RANGE SHOWN
15000
20000
10000
12T
14T
1400
0
BAR
PSI
35887 Load Cell
Description
The Greenlee 35887 Load Cell is a liquid-filled pressure
gauge intended to check the relief valve setting of Greenlee
and Greenlee Fairmont crimpers like models 1984, 1985
and our line of low pressure hydraulic crimpers.
A person who has not read and does
not understand all operating instructions
is not qualified to operate this tool.
Failure to read and understand
safety instructions could result in
injury or death.
Keep hands away from closing dies.
Failure to observe this warning could
result in an injury.
500
5000
1000
12 TON/14 TON
TOOL LOAD CELL
PROPER PRESSURE
RANGE SHOWN
15000
20000
10000
12T
14T
1400
0
BAR
PSI
NEEDLE
PRESSURE GAGE
14T RANGE SECTOR (1985 CRIMPER)
12T RANGE SECTOR (1984 CRIMPER)
TEST DIE SET
PRESSURE PAD
Greenlee Textron / Subsidiary of Textron Inc.
4455 Boeing Drive, Rockford, IL 61109-2988 USA
General Offices: 815/397-7070
Customer Center and Field Service: 800/435-0786
International Customer Service: 815/397-7070
Fax (24 Hour) Customer Center: 800/451-2632 815/397-1865
Canada Fax (24 Hour) Customer Center: 800/524-2853
International Fax (24 Hour) Customer Service: 815/397-1391
Purpose
This instruction manual is intended to familiarize opera-
tors and maintenance personnel with the safe operation
and maintenance procedures for the Greenlee 35887
Load Cell. This manual should be kept available to all
operating and maintenance personnel.
SAVE THESE INSTRUCTIONS
Additional copies of this manual are available
upon request at no charge.
Before using this load cell, read and understand
the manual supplied with your crimper.
Operation
1. Disconnect crimper from the hydraulic power source.
2. Remove crimping dies from the crimper.
3. Install the test dies.
4. Connect crimper to a hydraulic power source.
5. Position the load cell so that the pressure pad is
centered between the test dies.
6. Activate the crimper.
7. Continue to operate the crimper while monitoring the
gauge on the load cell. Note the reading on the
gauge when the relief valve activates. Make five
consecutive tests and record all of the readings.
8. See the manual supplied with your crimper for the
proper relief valve pressure range. If the highest
pressure displayed by the load cell is outside of this
range, adjust the relief valve setting as described in
the crimper manual or send the crimper to an
authorized service station for adjustment.
  • Page 1 1
  • Page 2 2

Greenlee H8508 / 48901 Impact Wrench Trigger Spool Kit User manual

Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI