Roland M-300 User manual

Type
User manual
1
Functionality added in M-300 version 1.11
Delay time can be set in sample units (p. 2).
A function has been added to exclusively switch off sends to MAIN L/R or to MAIN C when sends to MAIN L/R and
MAIN C are on (p. 3).
Functions that can be assigned to user buttons have been added (p. 3).
A function has been added that automatically applies the channel names on the M-300 to the track names on the
R-1000 when an R-1000 48-track recorder/player is connected and the M-300 is used as a recording source (p. 4).
The following RS-232C commands have been added.
For more information, refer to "V-Mixer RS-232C Reference."
Control commands
Display blackout/cancel blackout
Display brightness setting
Panel brightness setting
Lamp brightness setting
Request command
REAC connection status request
Display blackout status request
Display brightness request
Panel brightness request
Lamp brightness request
Reply-use commands
Error status
Connection-destination REAC device error status
1PS
2
Functionality added in M-300 version 1.11
Delays for MAIN L/R/C, AUX1 to 8, MTX1 to 4, and the delays provided for monitoring can be set using sample units.
1. At the SETUP section, press [SYSTEM].
The SYSTEM screen appears.
2. Use the DELAY UNIT selection button to select Sample.
Delay times can now be set using sample units.
Setting delay time in sample units
3
Functionality added in M-300 version 1.11
A function has been added to exclusively switch off sends to MAIN L/R or MAIN C when sends from CH1 to 32 and
AUX1 to 8 to MAIN L/R and MAIN C are on.
Switching on sends to MAIN L/R MAIN C switched off sends to MAIN C.
Switching on sends to MAIN C automatically switches off sends to MAIN L/R.
1. At the SETUP section, press [SYSTEM].
The SYSTEM screen appears.
2. At the MAIN OPTION selection buttons, select the check box for Mutually Exclusive LR/C
Assign.
Exclusion control is performed for sends to MAIN L/R and MAIN C.
The following functions can be assigned to user buttons.
Exclusion control of sends to MAIN L/R and MAIN C
Addition of functions assignable to user buttons
FUNCTION PARAM1 BUTTON Description
SYSTEM DISPLAY BLACKOUT
Flashing when the unit's display is
blacked out
Blacks out the unit's display
4
Functionality added in M-300 version 1.11
A function has been added that automatically applies the channel names on the M-300 to the track names on the R-
1000 when an R-1000 48-track recorder/player is connected via REAC and the M-300 is used as a recording source.
This function does not work when the version of the R-1000's system program is earlier than 1.100.
1. Display the R-1000 CONTROL popup.
2. At PREFERENCE, select the Name sync check box.
When recording is performed on the R-1000, the channel names on the M-300 used as the recording source are
applied to the track names on the R-1000.
The following rules are used to assign the track names according to the settings for the recording-use INPUT
patchbay on the R-1000 (the input connector assigned to the recording track) and the M-300's patchbay settings.
Automatic application of M-300 channel names to R-1000 track names
Assignment to R-1000 recording track Applied track name
MAIN L, R, C Channel name
MAIN MONO MAIN M
AUX 1 – 8
Channel name
MTX 1 – 4
MONITOR L, R MON L, MON R
REC L, R REC L, REC R
CH1 to 32 direct out Channel name
TALKBACK/OSCILLATOR TB/OSC
REAC A IN 1 – 40
When the corresponding input port is patched to the input channel,
the channel name.
When not patched, A IN1 to A IN40
REAC B IN 1 – 40
When the corresponding input port is patched to the input channel,
the channel name.
When not patched, B IN1 to B IN40
CONSOLE IN 1 – 12
When the corresponding input port is patched to the input channel,
the channel name.
When not patched, C IN1 to C IN12
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4