Enterasys Networks C2RPS-CHAS2 User manual

Category
Switchboard equipment
Type
User manual

This manual is also suitable for

SecureStack C2
Redundant Power Supply Chassis
C2RPS-CHAS2
Installation Guide
C2RPS-CHAS2
Caution: Do not use this product with SecureStack PoE devices. Any
SecureStack device with a “P” suffix in the model number (C2xxxx-xxP)
indicates a SecureStack PoE-compliant device and is not compatible with
this power system
Precaución: El RPS no es compatible con switches SecureStack C2 con
PoE. No intente conectar el cable de corriente del RPS a ningún switch
SecureStack C2 que tenga el sufijo “P” en el nombre del modelo, tal como
C2xxxxx-xxP. De lo contrario, el dispositivo puede dañarse.
9034091-01
i
Notice
Enterasys Networksreservestherighttomakechangesinspecificationsandotherinformationcontainedinthis
documentanditswebsitewithoutpriornotice.ThereadershouldinallcasesconsultEnterasys Networksto
determinewhetheranysuchchangeshavebeenmade.
Thehardware,firmware,orsoftwaredescribedinthisdocumentissubject
tochangewithoutnotice.
INNOEVENTSHALLENTERASYS NETWORKSBELIABLEFORANYINCIDENTAL,INDIRECT,SPECIAL,OR
CONSEQUENTIALDAMAGESWHATSOEVER(INCLUDINGBUTNOTLIMITEDTOLOSTPROFITS)ARISING
OUTOFORRELATEDTOTHISDOCUMENT,WEBSITE,ORTHEINFORMATIONCONTAINEDINTHEM,EVEN
IFENTERASYS NETWORKSHASBEENADVISEDOF,KNEWOF,ORSHOULDHAVEKNOWNOF,THE
POSSIBILITYOFSUCHDAMAGES.
Enterasys Networks, Inc.
50MinutemanRoad
Andover,MA01810
©2005Enterasys Networks, Inc.Allrightsreserved.
PartNumber: 903409101 April2005
ENTERASYS,ENTERASYS NETWORKS,ENTERASYSMATRIX,LANVIEW,MATRIX,NETSIGHT,WEBVIEW,and
anylogosassociatedtherewith,aretrademarksorregisteredtrademarksofEnterasys Networks, Inc.,intheUnited
Statesandother
countries.
Allotherproductnamesmentionedinthismanualmaybetrademarksorregisteredtrademarksoftheirrespective
companies.
DocumentationURL:http://www.enterasys.com/support/manuals
DocumentacionURL:http://www.enterasys.com/support/manuals
Dokumentationhttp://www.enterasys.com/support/manuals
Electrical Hazard: Only qualified personnel should perform installation procedures.
Advertencia eléctrica: Solamente personal calificado debe realizar procedimientos de instalacion.
Elektrischer Gefahrenhinweis: Installationen sollten nur durch ausgebildetes und qualifiziertes Personal
vorgenommen werden.
ii
Regulatory Compliance Information
Federal Communications Commission (FCC) Notice
ThisdevicecomplieswithPart15oftheFCCrules.Operationissubjecttothefollowingtwoconditions:(1)thisdevice
maynotcauseharmfulinterference,and(2)thisdevicemustacceptanyinterferencereceived,includinginterference
thatmaycauseundesiredoperation.
NOTE: Thisequipmenthasbeentestedandfoundtocomply
withthelimitsforaclassAdigitaldevice,pursuantto
Part15oftheFCCrules.Theselimitsaredesignedtoprovidereasonableprotectionagainstharmfulinterferencewhen
theequipmentisoperatedinacommercialenvironment.Thisequipmentuses,generates,andcanradiateradio
frequencyenergyandifnot
installedinaccordancewiththeoperatorsmanual,maycauseharmfulinterferenceto
radiocommunications.Operationofthisequipmentinaresidentialareaislikelytocauseinterferenceinwhichcase
theuserwillberequiredtocorrecttheinterferenceathisownexpense.
WARNING: Changesormodificationsmadetothisdevicewhicharenotexpresslyapprovedbytheparty
responsibleforcompliancecouldvoidtheusersauthoritytooperatetheequipment.
Industry Canada Notice
ThisdigitalapparatusdoesnotexceedtheclassAlimitsforradionoiseemissionsfromdigitalapparatussetoutinthe
RadioInterferenceRegulationsoftheCanadianDepartmentofCommunications.
Leprésentappareilnumériquen’émetpasdebruitsradioélectriquesdépassantleslimitesapplicablesauxappareils
numériquesdelaclassAprescrites
dansleRèglementsurlebrouillageradioélectriqueédictéparleministèredes
CommunicationsduCanada.
Class A ITE Notice
WARNING: ThisisaClassAproduct.Inadomesticenvironmentthisproductmaycauseradiointerferenceinwhich
casetheusermayberequiredtotakeadequatemeasures.
Clase A. Aviso de ITE
ADVERTENCIA:Estees unproductodeClaseA.Enunambientedomésticoesteproductopuedecausarinterferencia
deradioencuyocasopuedeserrequeridotomarmedidasadecuadas.
Klasse A ITE Anmerkung
WARNHINWEIS:DiesesProduktzähltzurKlasseA(Industriebereich).InWohnbereichenkanneshierdurchzu
Funkstörungenkommen,dahersolltenangemesseneVorkehrungenzumSchutzgetroffenwerden.
Product Safety
Thisproductcomplieswiththefollowing:UL60950,CSAC22.2No.60950,73/23/EEC,EN60950,IEC60950.
Seguridad del Producto
ElproductodeEnterasyscumpleconlosiguiente:UL60950,CSAC22.2No.60950,73/23/EEC,EN 60950.
Produktsicherheit
DiesesProduktentsprichtdenfolgendenRichtlinien:UL60950,CSAC22.2No.60950,73/23/EEC,EN60950.
iii
Electromagnetic Compatibility (EMC)
Thisproductcomplieswiththefollowing:47CFRParts2and15,CSAC108.8,89/336/EEC,EN55022,EN6100032,
EN 6100033,EN55024,AS/NZSCISPR22,VCCIV3.
Compatibilidad Electromágnetica (EMC)
EsteproductodeEnterasyscumpleconlosiguiente:47CFRPartes2y15,CSAC108.8,89/336/EEC,EN55022,
EN 55024,EN6100032,EN6100033,AS/NZSCISPR22,VCCIV3.
Elektro- magnetische Kompatibilität ( EMC )
DiesesProduktentsprichtdenfolgendenRichtlinien:47CFRParts2and15,CSAC108.8,89/336/EEC,EN55022,
EN 6100032,EN6100033,EN55024,AS/NZSCISPR22,VCCIV3.
VCCI Notice
ThisisaclassAproductbasedonthestandardoftheVoluntaryControlCouncilforInterferencebyInformation
TechnologyEquipment(VCCI).Ifthisequipmentisusedinadomesticenvironment,radiodisturbancemayarise.
Whensuchtroubleoccurs,theusermayberequiredtotakecorrectiveactions.
BSMI EMC Statement — Taiwan
ThisisaclassAproduct.Inadomesticenvironmentthisproductmaycauseradiointerferenceinwhichcasetheuser
mayberequiredtotakeadequatemeasures.
iv
Declaration of Conformity
ApplicationofCouncilDirective(s): 89/336/EEC
73/23/EEC
Manufacturer’sName: Enterasys Networks, Inc.
ManufacturersAddress: 50MinutemanRoad
Andover,MA01810
USA
EuropeanRepresentativeAddress: Enterasys Networks,Ltd.
NexusHouse,NewburyBusinessPark
LondonRoad,Newbury
BerkshireRG142PZ,England
ConformancetoDirective(s)/ProductStandards: ECDirective89/336/EEC
EN55022
EN6100032
EN6100033
EN55024
ECDirective73/23/EEC
EN60950
EquipmentType/Environment: Networking
Equipment,foruseinaCommercial
orLightIndustrialEnvironment.
Enterasys Networks, Inc.declaresthattheequipmentpackagedwiththisnoticeconformstotheabovedirectives.
v
Enterasys Networks, Inc.
Firmware License Agreement
BEFOREOPENINGORUTILIZINGTHEENCLOSEDPRODUCT,
CAREFULLYREADTHISLICENSEAGREEMENT.
Thisdocumentisanagreement(“Agreement”)betweentheenduser(“You”)andEnterasys Networks, Inc.onbehalf
ofitselfanditsAffiliates(ashereinafterdefined)(“Enterasys”)thatsetsforthYourrightsandobligationswithrespect
totheEnterasyssoftwareprogram/firmw areinstalledon
theEnterasysproduct(includinganyaccompanying
documentation,hardwareormedia)(“Program”)inthepackageandprevailsoveranyadditional,conflictingor
inconsistenttermsandconditionsappearingonanypurchaseorderorotherdocumentsubmittedbyYou.Affiliate”
meansanyperson,partnership,corporation,limitedliabilitycompany,orotherformofenterprise
thatdirectlyor
indirectlythroughoneormoreintermediaries,controls,oriscontrolledby,orisundercommoncontrolwiththeparty
specified.ThisAgreementconstitutestheentireunderstandingbetweentheparties,andsupersedesallprior
discussions,representations,understandingsoragreements,whetheroralorinwriting,betweenthepartieswith
respect
tothesubjectmatterofthisAgreement.TheProgrammaybecontainedinfirmware,chipsorothermedia.
BYINSTALLINGOROTHERWISEUSINGTHEPROGRAM,YOUREPRESENTTHATYOUAREAUTHORIZEDTO
ACCEPTTHESETERMSONBEHALFOFTHEENDUSER(IFTHEENDUSERISANENTITYONWHOSEBEHALF
YOUAREAUTHORIZEDTOACT,“YOU”AND“YOUR”SHALLBEDEEMEDTOREFERTOSUCHENTITY)AND
THATYOUAGREETHATYOUAREBOUNDBYTHETERMSOFTHISAGREEMENT,WHICHINCLUDES,
AMONGOTHERPROVISIONS,THELICENSE,THEDISCLAIMEROFWARRANTYANDTHELIMITATIONOF
LIABILITY.IFYOUDONOT
AGREETOTHETERMSOFTHISAGREEMENTORARENOTAUTHORIZEDTO
ENTERINTOTHISAGREEMENT,ENTERASYSISUNWILLINGTOLICENSETHEPROGRAMTOYOUANDYOU
AGREETORETURNTHEUNOPENEDPRODUCTTOENTERASYSORYOURDEALER,IFANY,WITHINTEN
(10)DAYSFOLLOWINGTHEDATEOFRECEIPTFORA
FULLREFUND.
IFYOUHAVEANYQUESTIONSABOUTTHISAGREEMENT,CONTACTENTERASYS NETWORKS,LEGAL
DEPARTMENTAT(978)6841000.
YouandEnterasysagreeasfollows:
1. LICENSE. Youhavethenonexclusiveandnontransferablerighttouseonlytheone(1)copyoftheProgram
providedinthispackagesubjecttothetermsandconditionsofthisAgreement.
2. RESTRICTIONS. ExceptasotherwiseauthorizedinwritingbyEnterasys,Youmaynot,normayYoupermitany
thirdpartyto:
(i) Reverseengineer,decompile,disassembleormodifytheProgram,inwholeorinpart,includingforreasons
oferrorcorrectionorinteroperability,excepttotheextentexpressly
permittedbyapplicablelawandtothe
extentthepartiesshallnotbepermittedbythatapplicablelaw,suchrightsareexpresslyexcluded.
InformationnecessarytoachieveinteroperabilityorcorrecterrorsisavailablefromEnterasysuponrequest
anduponpaymentofEnterasys’applicablefee.
(ii) IncorporatetheProgram,inwholeorinpart,inanyotherproductorcreatederivativeworksbasedonthe
Program,inwholeorinpart.
(iii) Publish,disclose,copy,reproduceortransmittheProgram,inwholeorinpart.
(iv) Assign,sell,license,sublicense,rent,lease,encumberbywayofsecurityinterest,pledgeorotherwisetransfer
theProgram,inwhole
orinpart.
(v) Removeanycopyright,trademark,proprietaryrights,disclaimerorwarningnoticeincludedonorembedded
inanypartoftheProgram.
vi
3. APPLICABLELAW. ThisAgreementshallbeinterpretedandgovernedunderthelawsandinthestateand
federalcourtsoftheCommonwealthofMassachusettswithoutregardtoitsconflictsoflawsprovisions.Youacceptthe
personaljurisdictionandvenueoftheCommonwealthofMassachusettscourts.Noneofthe1980UnitedNations
ConventiononContractsfortheInternationalSaleofGoods,theUnitedNationsConventionontheLimitationPeriod
intheInternationalSaleofGoods,andtheUniformComputerInformationTransactionsActshallapplytothis
Agreement.
4. EXPORTRESTRICTIONS. YouunderstandthatEnterasysanditsAffiliatesaresubjecttoregulationbyagencies
oftheU.S.Government,includingtheU.S.DepartmentofCommerce,whichprohibitexportordiversionofcertain
technicalproductstocertaincountries,unlessalicensetoexporttheProgramisobtainedfromtheU.S.Governmentor
anexceptionfromobtainingsuchlicensemayberelieduponbytheexportingparty.
If
theProgramisexportedfromtheUnitedStatespursuanttotheLicenseExceptionCIVundertheU.S.Export
AdministrationRegulations,YouagreethatYouareacivilenduseroftheProgramandagreethatYouwillusethe
Programforcivilendusesonlyandnotformilitarypurposes.
If
theProgramisexportedfromtheUnitedStatespursuanttotheLicenseExceptionTSRundertheU.S.Export
AdministrationRegulations,inadditiontotherestrictionontransfersetforthinSections1or2ofthisAgreement,You
agreenotto(i)reexportorreleasetheProgram,thesourcecode
fortheProgramortechnologytoanationalofacountry
inCountryGroupsD:1orE:2(Albania,Armenia,Azerbaijan,Belarus,Bulgaria,Cambodia,Cuba,Estonia,Georgia,
Iraq,Kazakhstan,Kyrgyzstan,Laos,Latvia,Libya,Lithuania,Moldova,NorthKorea,thePeople’sRepublicofChina,
Romania,Russia,Rwanda,Tajikistan,Turkmenistan,Ukraine,Uzbekistan,Vietnam,orsuch
othercountriesasmaybe
designatedbytheUnitedStatesGovernment),(ii)exporttoCountryGroupsD:1orE:2(asdefinedherein)thedirect
productoftheProgramorthetechnology,ifsuchforeignproduceddirectproductissubjecttonationalsecurity
controlsasidentifiedontheU.S.CommerceControl
List,or(iii)ifthedirectproductofthetechnologyisacomplete
plantoranymajorcomponentofaplant,exporttoCountryGroupsD:1orE:2thedirectproductoftheplantoramajor
componentthereof,ifsuchforeignproduceddirectproductissubjecttonationalsecuritycontrols
asidentifiedonthe
U.S.CommerceControlListorissubjecttoStateDepartmentcontrolsundertheU.S.MunitionsList.
5. UNITEDSTATESGOVERNMENTRESTRICTEDRIGHTS. TheenclosedProgram(i)wasdevelopedsolelyat
privateexpense;(ii)contains“restrictedcomputersoftware”submittedwithrestrictedrightsinaccordancewithsection
52.22719(a)
through(d)oftheCommercialComputerSoftwareRestrictedRightsClauseanditssuccessors,and(iii)in
allrespectsisproprietarydatabelongingtoEnterasysand/oritssuppliers.ForDepartmentofDefenseunits,the
ProgramisconsideredcommercialcomputersoftwareinaccordancewithDFARSsection227.72023anditssuccessors,
and
use,duplication,ordisclosurebytheGovernmentissubjecttorestrictionssetforthherein.
6. DISCLAIMEROFWARRANTY. EXCEPTFORTHOSEWARRANTIESEXPRESSLYPROVIDEDTOYOUIN
WRITINGBYEnterasys,EnterasysDISCLAIMSALLWARRANTIES,EITHEREXPRESSORIMPLIED,INCLUDING
BUTNOTLIMITEDTOIMPLIEDWARRANTIESOFMERCHANTABILITY,SATISFACTORYQUALITY,FITNESS
FORAPARTICULARPURPOSE,TITLEANDNON‐INFRINGEMENTWITHRESPECTTOTHEPROGRAM.IF
IMPLIEDWARRANTIESMAYNOTBEDISCLAIMEDBYAPPLICABLELAW,THENANYIMPLIEDWARRANTIES
ARELIMITEDINDURATIONTOTHIRTY(30)DAYSAFTERDELIVERYOFTHEPROGRAMTOYOU.
7. LIMITATIONOFLIABILITY. INNOEVENTSHALLENTERASYSORITS
SUPPLIERSBELIABLEFORANY
DAMAGESWHATSOEVER(INCLUDING,WITHOUTLIMITATION,DAMAGESFORLOSSOFBUSINESS,
PROFITS,BUSINESSINTERRUPTION,LOSSOFBUSINESSINFORMATION,SPECIAL,INCIDENTAL,
CONSEQUENTIAL,ORRELIANCEDAMAGES,OROTHERLOSS)ARISINGOUTOFTHEUSEORINABILITYTO
USETHEPROGRAM,EVENIFENTERASYSHASBEENADVISEDOFTHEPOSSIBILITY
OFSUCHDAMAGES.
THISFOREGOINGLIMITATIONSHALLAPPLYREGARDLESSOFTHECAUSEOFACTIONUNDERWHICH
DAMAGESARESOUGHT.
THECUMULATIVELIABILITYOFENTERASYSTOYOUFORALLCLAIMSRELATINGTOTHEPROGRAM,IN
CONTRACT,TORTOROTHERWISE,SHALLNOTEXCEEDTHETOTALAMOUNTOFFEESPAIDTO
ENTERASYSBYYOUFORTHERIGHTSGRANTEDHEREIN.
vii
8. AUDITRIGHTS. YouherebyacknowledgethattheintellectualpropertyrightsassociatedwiththeProgramare
ofcriticalvaluetoEnterasysand,accordingly,Youherebyagreeto maintaincompletebooks,recordsandaccounts
showing(i)licensefeesdueandpaid,and(ii)theuse,copyinganddeploymentoftheProgram.Youalsograntto
Enterasysanditsauthorizedrepresentatives,uponreasonablenotice,therightto auditandexamineduringYour
normalbusinesshours,Yourbooks,records,accountsandhardwaredevicesuponwhichtheProgrammaybedeployed
toverifycompliancewiththisAgreement,includingtheverificationofthelicensefeesdueandpaidEnterasys
andthe
use,copyinganddeploymentoftheProgram.Enterasys’rightofexamination shallbeexercisedreasonably,ingood
faithandinamannercalculatedtonotunreasonablyinterferewithYourbusiness.Intheeventsuchauditdiscovers
noncompliancewiththisAgreement,includingcopiesoftheProgrammade,usedordeployed
inbreachofthis
Agreement,YoushallpromptlypaytoEnterasystheappropriatelicensefees.Enterasys reservestheright,tobe
exercisedinitssolediscretionandwithoutpriornotice,toterminatethislicense,effectiveimmediately,forfailureto
complywiththisAgreement.Uponanysuchtermination,Youshallimmediatelycease
alluseoftheProgramandshall
returntoEnterasystheProgramandallcopiesoftheProgram.
9. OWNERSHIP. Thisisalicenseagreementandnotanagreementforsale.Youacknowledgeandagreethatthe
Programconstitutestradesecretsand/orcopyrightedmaterialofEnterasysand/oritssuppliers.Youagreeto
implementreasonablesecuritymeasurestoprotectsuchtradesecretsandcopyrightedmaterial.Allright,titleand
interestinandtotheProgramshallremainwithEnterasysand/oritssuppliers.Allrightsnotspecificallygrantedto
YoushallbereservedtoEnterasys.
10. ENFORCEMENT. YouacknowledgeandagreethatanybreachofSections2,4,or9ofthisAgreementbyYoumay
causeEnterasysirreparabledamageforwhichrecoveryofmoneydamageswouldbeinadequate,andthatEnterasys
maybeentitledtoseektimelyinjunctiverelieftoprotectEnterasys’rightsunderthisAgreementinadditiontoanyand
allremediesavailableatlaw.
11. ASSIGNMENT. Youmaynotassign,transferorsublicensethisAgreementoranyofYourrightsorobligations
underthisAgreement,exceptthatYoumayassignthisAgreementtoanypersonorentitywhichacquiressubstantially
allofYourstockorassets.EnterasysmayassignthisAgreement initssolediscretion.
ThisAgreementshallbebinding
uponandinuretothebenefitoftheparties,theirlegalrepresentatives,permittedtransferees,successorsandassignsas
permittedbythisAgreement.Anyattemptedassignment,transferorsublicenseinviolationofthetermsofthis
AgreementshallbevoidandabreachofthisAgreement.
12. WAIVER. AwaiverbyEnterasysofabreachofanyofthetermsandconditionsofthisAgreementmustbein
writingandwillnotbeconstruedasawaiverofanysubsequentbreachofsuchtermorcondition.Enterasys’failureto
enforceatermuponYourbreachofsuchtermshallnotbeconstruedasawaiverofYourbreachorpreventenforcement
onanyotheroccasion.
13. SEVERABILITY. IntheeventanyprovisionofthisAgreementisfoundtobeinvalid,illegalorunenforceable,the
validity,legalityandenforceabilityofanyoftheremainingprovisionsshallnotinanywaybeaffected
orimpaired
thereby,andthatprovisionshallbereformed,construedandenforcedtothemaximumextentpermissible.Anysuch
invalidity,illegalityorunenforceabilityinanyjurisdictionshallnotinvalidateorrenderillegalorunenforceablesuch
provisioninanyotherjurisdiction.
14. TERMINATION. EnterasysmayterminatethisAgreementimmediatelyuponYourbreachof
anyoftheterms
andconditionsofthisAgreement.Uponanysuchtermination,YoushallimmediatelyceasealluseoftheProgramand
shallreturntoEnterasystheProgramandallcopiesoftheProgram.
viii
ix
Contents
About This Guide
Who Should Use This Guide ................................................................................................................ xi
How to Use This Guide ........................................................................................................................ xi
Related Documents ............................................................................................................................ xii
Conventions Used in This Guide ........................................................................................................xiii
Chapter 1: Introduction
RPS Overview ....................................................................................................................................1-1
C2RPS-CHAS2 Chassis ....................................................................................................................1-2
C2RPS-PSM Power Supply Module ..................................................................................................1-3
RPS Deployment Strategies ..............................................................................................................1-4
Chapter 2: Installation
Required Tools ...................................................................................................................................2-1
Unpacking Chassis and Power Supply Module(s) .............................................................................2-1
Installing C2RPS-PSMs .....................................................................................................................2-2
Replacing an Installed C2RPS-PSM ...........................................................................................2-3
Installing C2RPS-CHAS2 into the Rack .............................................................................................2-4
Guidelines for Rackmount Installation .........................................................................................2-4
Rack Mounting the Chassis .........................................................................................................2-5
Connecting the PSM Cables and AC Power Cords ...........................................................................2-6
Appendix A: Specifications
C2RPS-CHAS2 Chassis Specifications ............................................................................................ A-1
C2RPS-PSM Specifications .............................................................................................................. A-2
C2RPS-PSM Redundant Power Supply Output Connector .............................................................. A-2
Compliance Standards ...................................................................................................................... A-3
Figures
1-1 SecureStack C2RPS-CHAS2 (front view without PSM).........................................................1-2
1-2 SecureStack C2RPS-CHAS2 (front view with two PSMs) .....................................................1-2
1-3 SecureStack C2RPS-CHAS2 (rear view with two PSMs) ......................................................1-2
1-4 C2RPS-PSM (front view) .......................................................................................................1-3
1-5 C2RPS-PSM (rear view) ........................................................................................................1-3
1-6 RPS Supporting Two SecureStack Switches.........................................................................1-4
2-1 C2RPS-PSM Installation........................................................................................................2-3
2-2 Fastening the C2RPS-CHAS2 to the Rack............................................................................2-5
2-3 C2RPS-PSM Cable................................................................................................................2-6
2-4 Power Connectors on C2RPS-PSM (rear view).....................................................................2-6
2-5 C2RPS-PSM Cable and AC Power Cord Connections..........................................................2-7
A-1 C2RPS-PSM Redundant Power Supply Connector Pin Locations ....................................... A-2
x
Tables
2-1 Contents of C2RPS-CHAS2 Carton.......................................................................................2-2
2-2 Contents of C2RPS-PSM Carton ...........................................................................................2-2
A-1 C2RPS-CHAS2 Specifications.............................................................................................. A-1
A-2 C2RPS-PSM Specifications .................................................................................................. A-2
A-3 C2RPS-PSM Redundant Power Supply Connector Pin Functions ....................................... A-3
A-4 Compliance Standards.......................................................................................................... A-3
SecureStack C2 Installation Guide xi
About This Guide
Thisguideprovidesanoverview,installationandtroubleshootinginstructions,and
specificationsfortheEnterasysNetworks™SecureStackC2redundantpowersupply
chassis(C2RPSCHAS2),powersupplymodule(C2RPSPSM),DCpowercables
(C2RPSPSMCable),andACpowercords.
Who Should Use This Guide
Thisguideisintendedforanetworkadministrator responsible forinstallingandsetting
upthestackableswitch.
How to Use This Guide
Readthroughthisguidecompletelytofamiliarizeyourselfwithitscontentsandgainan
understandingofthefeaturesandcapabilitiesoftheRPScomponents.Ageneralworking
knowledgeofdatacommunicationsnetworksishelpfulwhensettingupanRPS
(C2RPSCHAS2chassiswithoptionalpowersupplymodules).
Note: In this document, the following terms are used:
RPS refers to a complete redundant power system, which includes a C2RPS-CHAS2
chassis and optional power supply modules.
Chassis refers to the C2RPS-CHAS2 chassis.
PSM refers to the C2RPS-PSM power supply module.
PSM cable refers to the C2RPS-PSM Cable (12 Vdc power cable).
Electrical Hazard: Only qualified personnel should perform installation procedures.
Riesgo Electrico: Solamente personal calificado debe realizar procedimientos de
instalacion.
Elektrischer Gefahrenhinweis: Installationen sollten nur durch ausgebildetes und
qualifiziertes Personal vorgenommen werden.
Related Documents
xii About This Guide
ThisprefaceprovidesanoverviewofthisguideandtheSecureStackC2manualset,anda
briefsummaryofeachchapter,andtheconventionsusedthroughoutthisguide.Tolocate
informationinthisguide,refertothefollowingtable:
Related Documents
OthermanualshavebeendevelopedfortheSecureStackC2nonPoEswitchdevicesthat
canbeconnectedtotheRPSforpowerredundancy.
TheSecureStackC2switchmanualsexplainhowtoinstalltheswitchdevi ce,connect
networkcablesegmentstotheSecureStackC2switchdevice,andconfiguretheswitch
deviceusing
thecommandlineinterfacecommandsdescribedintheSecureStackC2
ConfiguratonGuide.
Eachmanualiswrittenforqualifiedpersonnelresponsibleforinstallingtheswitchdevice
andalsohaveageneralworkingknowledgeofdatacommunicationsnetworksandtheir
physicallayercomponents.
For... Refer to...
The features and capabilities of the C2RPS-CHAS2
chassis and optional power supply modules. This
chapter also provides the instructions for obtaining help
from Enterasys Networks, if needed.
Chapter 1, Introduction
Instructions to install an RPS into a standard 19-inch
rack. This involves installing the C2RPS-CHAS2 chassis,
one or two PSMs, PSM interconnecting cables, and AC
power cords.
Chapter 2, Installation
Specifications for the C2RPS-CHAS2 chassis, PSM,
PSM cable, Redundant Power Supply connector pinout
descriptions, and Compliance Standards.
Appendix A, Specifications
Caution: The RPS does not support PoE-compliant C2 switches. Do not try to connect the
power cable from this RPS to any C2 switch with a “P” suffix in the model name, such as
C2xxxxx-xxP. Otherwise, damage to the device may result.
Precaución: El RPS no es compatible con switches SecureStack C2 con PoE. No intente
conectar el cable de corriente del RPS a ningún switch SecureStack C2 que tenga el sufijo
“P” en el nombre del modelo, tal como C2xxxxx-xxP. De lo contrario, el dispositivo puede
dañarse.
Note: Connection of the RPS system does not require reconfiguration of the connected
Ethernet Switch.
Conventions Used in This Guide
SecureStack C2 Installation Guide xiii
Conventions Used in This Guide
Thefollowingconventionsareusedinthisguide:
Note: Calls the reader’s attention to any item of information that may be of special
importance.
Caution: Contains information essential to avoid damage to the equipment.
Precautión: Contiene información esencial para prevenir dañar el equipo.
Achtung: Verweißt auf wichtige Informationen zum Schutz gegen Beschädigungen.
Electrical Hazard: Warns against an action that could result in personal injury or death
due to an electrical hazard.
Riesgo Electrico: Advierte contra una acción que pudiera resultar en lesión corporal o la
muerte debido a un riesgo eléctrico.
Elektrischer Gefahrenhinweis: Warnung vor sämtlichen Handlungen, die zu Verletzung
von Personen oder Todesfällen – hervorgerufen durch elektrische Spannung – führen
können!
Warning: Warns against an action that could result in personal injury or death.
Advertencia: Advierte contra una acción que pudiera resultar en lesión corporal o la
muerte.
Warnhinweis: Warnung vor Handlungen, die zu Verletzung von Personen oder gar
Todesfällen führen können!
Conventions Used in This Guide
xiv About This Guide
SecureStack C2 Installation Guide 1-1
1
Introduction
ThischapterprovidesafunctionaloverviewofaRedundantPowerSystem(RPS).
RPSOverview
AnRPS(redundantpowersystem)consistingofaC2RPSCHAS2chassisand
C2RPSPSMpowersuppliesisasimpleandeconomicalsolutiontoprovidebackup
powerforoneortwoSecureStackC2Ethernetswitchdevices(oneforeachswitchdevice).
WhenaC2RPSPSMisconnectedtoaswitchdevice,it
continuouslymonitorstheinternal
powersupplyoftheswitchdevice.Ifapowerinterruptionisdetected,theC2RPSPSMis
automaticallytriggeredtoprovidepowerfortheswitchdevice,preventingan
interruptioninnetworktraffic.Theendresultisamorereliablenetworkinfrastructure,
protectingthenetworkfromasingle
sourceoffailurefromanetworkdevicepower
supply.
Dependingonyoursystemrequirements,theC2RPSCHAS2chassiscanconsistofthe
followingcomponentstoprovideredundantpowerforoneortwoswitchdevices:
•OneC2RPSCHAS2chassis
•OneortwoC2RPSPSMs(oneperSecureS tackswitchdevice)
•OneortwoACpower
cords(oneperC2RPSPSM)
•OneortwoC2RPSPSMCables(oneperC2RPSPSM)
For information about... Refer to page...
RPS Overview 1-1
C2RPS-CHAS2 Chassis 1-2
C2RPS-PSM Power Supply Module 1-3
RPS Deployment Strategies 1-4
Getting Help 1-5
Note: The chassis is shipped without a PSM. The PSMs are ordered separately. Each
PSM is shipped with an interconnecting C2RPS-PSM Cable and an AC power cord.
C2RPS-CHAS2 Chassis
1-2 Introduction
C2RPS-CHAS2 Chassis
ThechassisisatwoslotframewithoutACpowerconnectionsorelectronics.Thechassis
canbeinstalledinastandard19inchrackandpopulatedwithoneortwoPSMs.Each
PSMoperatesindependently.Figure 11showsthefrontviewofthechassiswithout
PSMs.Figure 12andFigu re 13
showthefrontandrearviewsofafullypopulated
chassis.
Figure 1-1 SecureStack C2RPS-CHAS2 (front view without PSM)
_______________________________________________________________________________
Figure 1-2 SecureStack C2RPS-CHAS2 (front view with two PSMs)
_______________________________________________________________________________
Figure 1-3 SecureStack C2RPS-CHAS2 (rear view with two PSMs)
_______________________________________________________________________________
C2RPS-CHAS2
C2RPS-CHAS2
C2RPS-PSM
Power
C2RPS-PSM
Power
AC LINE
100-240 VAC
50-60 Hz
2A MAX
Redundant Power Supply
AC LINE
100-240 VAC
50-60 Hz
2A MAX
Redundant Power Supply
C2RPS-PSM Power Supply Module
SecureStack C2 Installation Guide 1-3
C2RPS-PSM Power Supply Module
TheC2RPSPSMprovidesthefollowing:
•Hotswapcapability.
•One12Vdc,150Wattsofmaximumcontinuouspoweroutputtoaconnected
SecureStackC2switchdevice.
FrontpanelStatusLEDthatindicatesifthePSMisoperatingcorrectly.
Figures14and15showthefrontand rearviewofthe
C2RPSPSM.
Figure 1-4 C2RPS-PSM (front view)
Figure 1-5 C2RPS-PSM (rear view)
1 Intake cooling fans 3 Captive screws (2)
2 AC power LED
1 Redundant Power Supply connector
(12 Vdc inputs and PSM status outputs)
2 AC input connector
À
C2RPS-PSM
Power
 Â
Á
AC LINE
100-240 VAC
50-60 Hz
2A MAX
Redundant Power Supply
À Á
RPS Deployment Strategies
1-4 Introduction
RPS Deployment Strategies
TheRPScanbedeployedinavarietyofsituationswithmissioncriticalapplications.
For example:
•ForuseinavoiceanddatanetworkwhereswitchesareconnectedtoIPphonesand
PCs.ConnectinganRPStotheswitchescanpreventvoicenetworkfailurescausedby
switchpowerfailures.
•Forusein
traditionaldata10/100/1000Ethernetswitchescarryingmissioncritical
data.
Figure 16showsanexampleoftheRPSprovidingredundantpowerbackupfortwo
SecureStackC2switches.IfaSecureStackC2switchdeviceexperiencesaninternalpower
supplyfailure,thefollowingoccurs:
1. TheinternalDCpowersourceoftheswitchdeviceis
immediatelyswitchedover
fromtheinternalDCpowersupplytotheRPSDCpowerinput.
2. Theswitchdevicesavesthisstatusinformationforfutureretrieval,ifnecessary.
Figure 1-6 RPS Supporting Two SecureStack Switches
1 C2RPS-CHAS2 chassis (front view with two PSMs) 3 SecureStack C2 Ethernet switches
2 C2RPS-PSM Cables for 12 Vdc and status
information from PSMs
Note: The C2RPS-PSMs used in C2RPS-CHAS2 are interchangeable with those used in
the C2RPS-CHAS8 chassis available from Enterasys Networks.
CONSOLE
1
2
23
24
21 22 23 24
CPU
UP
RPS
MASTER
DOWN
C2G124-24
CONSOLE
1
2
23
24
21 22 23 24
CPU
UP
RPS
MASTER
DOWN
C2G124-24
C2RPS-CHAS2
C2RPS-PSM
Power
C2RPS-PSM
Power
À
Á
Â
Á
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34

Enterasys Networks C2RPS-CHAS2 User manual

Category
Switchboard equipment
Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document