1 Quadra-Fire • Fogata Grande October 2006
Owners Manual
Installation and Operation
Installation and service of this appliance should be performed
by qualified personnel. Hearth & Home Technologies
suggests NFI certied or factory-trained
professionals, or technicians supervised
by an NFI certied professional.
If the information in these
instructions is not followed
exactly, are or explosion may
result causing property damage,
personal injury, or death.
• Donotstoreorusegasolineorotheram
-
mablevaporsandliquidsinthevicinityof
thisoranyotherappliance.
What to do if you smell gas:
- Do
nottrytolightanyappliance.
- Donottouchanyelectricalswitch.Donot
useanyphoneinyourbuilding.
- Immediatelycallyourgassupplierfrom
a neighbor’s phone. Follow the gas
supplier’sinstructions.
- Ifyoucannotreachyourgassupplier,call
theredepartment.
• Installationandservicemustbeperformed
byaqualiedinstaller,serviceagency,or
thegassupplier.
• ForOutdoorUseOnly.
WARNING
HOT! DO NOT TOUCH.
SEVERE BURNS MAY RESULT.
CLOTHING IGNITION MAY RESULT.
WARNING
• Keepchildrenaway.
• CAREFULLYSUPERVISEchildrenaroundtherepit.
• Alert children and adults to hazards of high
temperatures.
• Keep clothing, furniture, draperies and other
combustiblesaway.
Castironandothersurfacesarehotduring
operationandcooldown.
DO NOT DISCARD THIS MANUAL
CAUTION
• Important operating and
maintenanceinstructions
included.
Leavethismanualwith
party responsible for
useandoperation.
Read,understandandfollow
these instructions for safe
installationandoperation.
Models: FG21SP-NG
FG21SP-LP
Decorative Gas Log Set
For Use With The Fogata
Grande only
Improperinstallation,adjustment,alteration,serviceor
maintenancecancauseinjuryorpropertydamage.Read
theinstallation,operatingandmaintenanceinstructions
thoroughlybeforeinstallingorservicingthisequipment.
WARNING
HOT! DO NOT TOUCH.
SEVERE BURNS MAY RESULT.
CLOTHING IGNITION MAY RESULT.
WARNING
• Keepchildrenaway.
• CAREFULLYSUPERVISEchildrenaroundtherepit.
• Alert children and adults to hazards of high
temperatures.
• Keep clothing, furniture, draperies and other
combustiblesaway.
Castironandothersurfacesarehotduring
operationandcooldown.
HOT! DO NOT TOUCH.
SEVERE BURNS MAY RESULT.
CLOTHING IGNITION MAY RESULT.
WARNING
• Keepchildrenaway.
• CAREFULLYSUPERVISEchildrenaroundtherepit.
• Alert children and adults to hazards of high
temperatures.
• Keep clothing, furniture, draperies and other
combustiblesaway.
Castironandothersurfacesarehotduring
operationandcooldown.
2 Quadra-Fire • Fogata Grande October 2006
Read this manual before installing or operating this appliance.
Please retain this owners manual for future reference.
CongratulationsonselectingaQuadra-Firedecorativegas
logset.TheFogataGrandeyouhaveselectedisdesignedto
providetheutmostinsafety,reliability,andentertainment.
AstheownerofaFogataGrande,you’llwanttoreadand
carefullyfollowalloftheinstructionscontainedinthisowner’s
manual.Payspecialattentiontoallcautionsandwarnings.
Thisownersmanualshouldberetainedforfuturereference.
Wesuggestyoukeepitwithyourotherimportantdocuments
andproductmanuals.
The information contained in this owner’s manual, unless
noted otherwise, applies to all models and gas control
systems.
YournewFogataGrandewillgiveyouyearsofdurableuse
and trouble-free enjoyment. Welcome to the Quadra-Fire
familyofapplianceproducts!
Homeowner Reference Information
ModelName: Datepurchased/installed:
SerialNumber: Locationonappliance:
Dealershippurchasedfrom: Dealerphone:
Notes:
We recommend that you record the following pertinent
information about your appliance:
Listing Label Information/Location
Themodelinformationregardingyourspecicappliancecanbefoundontheratingplatelocatedinthecontrolareaofthe
appliance.
Congratulations
LISTED
OUTDOOR
GAS FIREPLACE
CSA4.96U.S.(3rdEd.),OutdoorGasFireplace
Quadra-Fire
20802 Kensington Blvd
Lakeville, MN 55044
Models:FG21SP-NG
FG21SP-LP
Outdoor Gas Fireplace
TypeofGas:
Min.GasSupplyforinputAdj.
Max.GasSupply:
ManifoldPressure:
Max180,000BTU’s/H
WARNING:MustNotBeUsedForCooking
WARNING:ForOutdoorUseOnly.If StoredIndoors,Detatchand Leave
CylindarOutdoors.
MINIMUMCLEARANCES:
Minimumclearancesfromsideandbackofunittoadjacentcombustibleconstruction10footfromsideand10footfromback.
Unitmustbeinstalledonanon-combustiblesurface
Thisapliancemustbeinstalledinaccordancewithlocalcodes,ifany.Ifnone,followANSIZ223.1installationcodes
Manufacturer:Hearth&HomeTechnologies,Decatur,GA30035
MFG.DATE:Serial#:
Report No. 324-L-01-5
3 Quadra-Fire•FogataGrande October2006
Table of Contents
1 Listing and Code Approvals
A. ApplianceCertication. . . . . . . . . . . . . . . . . . . . . . . . . 3
B. BTUSpecications
. . . . . . . . . . . . . . . . . . . . . . . . . . . 3
2 Getting Started
A. DesignandInstallationConsiderations. . . . . . . . . . . . 5
B. ToolsandSuppliesNeeded
. . . . . . . . . . . . . . . . . . . . . 5
C. InspecttheApplianceandComponents
. . . . . . . . . . . 6
3 Framing and Clearances
A. SelectApplianceLocation. . . . . . . . . . . . . . . . . . . . . . 7
B. Clearances . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
4 Appliance Setup
A. BurnerAssembly. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
B. LogAssembly
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
5 Gas Information
A. Fuel. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
B.
Gas Pressure . . . . . . . . . . . . . . . . . . . . . . . . .10
C. Gas Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
D. HighAltitudeInstallations . . . . . . . . . . . . . . . . . 11
6 Operating Instructions
A. BeforeLightingAppliance. . . . . . . . . . . . . . . . . . . . . 12
Lighting the Appliance
. . . . . . . . . . . . . . . . . . . . . . . . 13
B. AftertheApplianceisLit . . . . . . . . . . . . . . . . . . . . . . 14
7 Troubleshooting 15
8 Maintaining and Servicing the Appliance 16
9 Reference Materials
A. ServicePartsList............................ 17
B. Logs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
C. LimitedLifetimeWarranty
. . . . . . . . . . . . . . . . . . . . . 20
4 Quadra-Fire • Fogata Grande October 2006
1
Listing and Code Approvals
A. Appliance Certication
The Fogata Grande has been tested in accordance with
CSA International Requirement 4.96 U.S. for Outdoor
Gas Fireplaces, 2004 for the U.S. and Canada and has
beenlisted byOMNI-TestLaboratories,Inc.forinstallation
and operation as described in these installation and operat-
inginstructions.
Theinstallationmustconformwithlocalcodesor,intheab-
senceoflocalcodes,withtheNationalFuelGasCodeANSI
Z223.1orCSAB149.1,NaturalGasandPropaneInstalla-
tionCode.
MODELS: Fogata Grande
LABORATORY: OMNI-TestLaboratories,Inc.
TYPE: DecorativeGasLogSet
STANDARD: CSA International Requirement 4.96 U.S.
For Outdoor Gas Fireplaces, 2004
B. BTU Specications
Model
Max Input
BTUH Orice Size
FG21SP-NG
180,000 19/64
FG21SP-LP 180,000 20
5 Quadra-Fire•FogataGrande October2006
DoNOTusethisapplianceifanyparthasbeenunder
water.Immediatelycallaqualiedservicetechnician
toinspecttheapplianceandtoreplaceanypartofthe
controlsystemandanygas controlwhichhasbeen
underwater.
WARNING
Checkbuildingcodespriortoinstallation.
• Installation MUST comply with local, regional,
stateandnationalcodesandregulations.
• Consult insurance carrier, local building, fire
ofcials or authorities having jurisdiction about
restrictions,installationinspection,andpermits.
CAUTION
A. Design and Installation Considerations
When planning an appliance installation, it’s necessary to
determinethefollowinginformationbeforeinstalling:
• Wheretheapplianceistobeinstalled.See Sections 3
and 4.
• Gassupplypiping.See Section 5.
• Framingandnishingdetails.See Sections 3 and 4.
2
Getting Started
ThisapplianceisaDecorativeGasLogSetforOUTDOOR
USE ONLY and MUST NOTbeusedforcooking.
PlacetheFogataGrandeonaatandstablenon-combust-
able surface in an outdoor location such as a patio. This
locationmustbeadjacenttothegassupplyline.DO NOT
locate the appliance where it can get excessively wet
or submerged in water.(Normal Weather Precipitation is
acceptable)
Do NotBurnSolidFuelsinThisAppliance.
Asphyxiation Risk
• Thisgaslogsetisforoutdooruseinawell-
ventilatedspace.
• Log set must not be installed inside an
enclosedstructureorunventedappliance.
WARNING
Hearth&HomeTechnologiesdisclaimsany
responsibility for, and the warranty will be
voidedby,thefollowingactions:
• Installationanduseofanydamagedcomponents.
• Modicationoftheburnerorlogassemblies.
• InstallationotherthanasinstructedbyHearth&Home
Technologies.
• Improperpositioningofthegaslogs.
• Installation and/or use of any component part not
approvedbyHearth&HomeTechnologies.
Any such action may cause a re hazard.
WARNING
B. Tools and Supplies Needed
Beforebeginningtheinstallationbesurethatthefollowing
toolsandbuildingsuppliesareavailable.
Gloves
Safetyglasses
Flatbladescrewdriver
Non-corrosiveleakchecksolution
Wrenches
Drillandhexheaddrivers
Masonrydrillbit3/16
Sharp Edges
• Wear protective gloves
and safety glasses during
installation.
CAUTION
6 Quadra-Fire • Fogata Grande October 2006
Inspect appliance and components for
damage. Damaged parts may impair safe
operation.
• DoNOTinstalldamagedcomponents.
• DoNOTinstallincompletecomponents.
• DoNOTinstallsubstitutecomponents.
Reportdamagedpartstodealer.
WARNING
C. Inspect the Appliance and Components
• Carefullyremovetheapplianceandcomponentsfromthe
packaging
• Thegaslogsmaybepackagedseparatelyandmustbe
eldinstalled.
• Reporttoyourdealeranypartsdamagedinshipment.
Read all of the instructions before starting the
installation. Follow these instructions carefully
during the installation to ensure maximum safety and
benet.
Valve Control Box Assembly
Burner Assembly
7 Quadra-Fire • Fogata Grande October 2006
Note:
• Illustrations reect typical installations and are FOR
DESIGNPURPOSESONLY.
• Illustrations/diagramsarenotdrawntoscale.
• Actual installation may vary due to individual design
preference.
Fire Risk
Provideadequateclearance:
• Aroundairopenings.
• Forserviceaccess.
Locateapplianceawayfromtrafcareas.
WARNING
A. Select Appliance Location
Whenselectingalocationforyourapplianceitisimportant
toconsidertherequiredclearancestoallcombustibles.
3
Framing and Clearances
B. Clearances
PlacetheFogataGrandeonaatstablesurface.Theclear
-
ancerequirementstoanycombustiblematerial,toanyside,
isaminimumof24inches.
Combustible materials are not allowed over the top of the
FogataGrande.
10’
10’
Non-combustible
10’
10’
Non-combustible
8 Quadra-Fire • Fogata Grande October 2006
4
Appliance Set Up
1)AfterplacingtheFogataGrandeinthedesiredlocation,
locatetheovalholeintherebowlandbesureitisposi-
tioned towards the leg where the gas connection is to be
made.
2)Withthelettersprovided,usingtape,identifyleg“A”as
thelegtowhichthegasvalveassemblywillbeattached.
Movingcounterclockwise,labletheremaininglegs“B”,“C”
and“D”asshowninFigure1.Thiswillassityouininstalling
thelogsafterthegasconnectionshavebeenmade.
3)AsshowninFigure2,layleg“A”onitsface(onasmooth
nonabrasivesurfaceto prevent damaging thesurface)to
begintheassemblyofthegassystem.
Asshow,placethegasvalvecontrolboxontheinsideofleg
“A”.Locatetheopenendoftheboxassembly1/2inchback
fromtheedgeofthelegasshowninFigure1.
Nextpositionthetopangewiththetwokeyholeanchor
-
ing holes approximately 3/4 inch down from the seam as
shown.Pre-Drilltheholeswithamasonrydrillbitandse-
curethetwomasonryscrewsthroughthetopoftheholes
providedintotheleg.Donotcompletelytightensincethe
controlboxwillneedtoberemovedinordertocompletethe
nalinstallation.
Once the screws have been installed, remove the valve
controlboxinordertoassembletheothercomponenets.
Figure 2
4)Foryourconvenience,thePilotassembly,Figure3,may
have already been installed on burner. In the event that
thePilotassemblyisnotinstalled,locatethecrosssection
oftheburnerwiththecoloredhighlight.(thiswillbeonthe
innerringatthecrosssection.Notetheport-holeswillbe
facingdown).InsertthePilothoodbracketovertheburner
tubeandslideitforwardsothetopfrontclipslidesoverthe
tubeoftheburnerandcoversthehighlightedmarkingson
theburnertube.Inordertoassembletheunit,thePilothood
bracketmayneedtobeinsertedatanangleandtwistedinto
placetoensurethattheunitisinitsproperposition.
Figure 3
5)Placethestainlesssteelgrate(heavyroundbargrate,
suppliedwithrepit)inpositioninthelowerpartofthebowl.
Thisgratewillrestontopofthelowertabs.
Nextplacethescreenoverthegratesothattheovalopen-
inginthescreenlinesupwiththedirectionofthestainless
barsonthegrateasshowninFigure4.
Feedtheburnerex line, pilot tubeandpiezoignitor wire
downthroughthecenterofthescreenandgrateandthrough
theovalholeinthesideofthebowl
Theburnerwillrestatontheinsideofthebowl.
Figure 4
Figure 1
9 Quadra-Fire•FogataGrande October2006
6)Withthevalvecontrolboxundertheedgeofthebowl,
connectthepilottubetothetopofthevalveinthecontrol
box.
Thestainlesssteelexconnectoristobeconnectedtothe
brasselbowlocatedonthetopofthevalvecontrolbox.
Thepiezoignitorleadistobeconnectedtotheignitorlead
comingoutofthevalvecontrolbox.
7)Feedthethermopileupthroughtheovalholeinthebowl
andinsertitintotheopenholeinthepilotassembly.Ensure
thatthethermopilesnapsintoplaceandissecurlyinposi
-
tiontoensureproperconnection.
Figure 5
8)Replaceleg“A”undertheFogataGrandebowlandse-
curethevalvecontrolboxonthetwoscrewspreviouslyin-
stalledinstep3
9)Withallthegascomponetsnowsecurlyinplace,take
thelavarocksuppliedandspreaditoverthescreensothat
itcoversthesidesoftheburnerbutensureitdoesnotcover
thetopoftheburnerinordertoensureproperame
10)LogInstalationandplacementinstructionsforthelogset
areprovidedwiththelogset
Thermopile
10 Quadra-Fire • Fogata Grande October 2006
A. Fuel
Beforemakinggasconnectionsensureappliancebeingin-
stallediscompatiblewiththeavailablegastype.
B. Gas Pressure
Properinputpressuresarerequiredforoptimumappliance
performance.Gaslinesizingrequirementsneedtobemade
followingNFPA51.
5
Gas Information
Fire Risk
Explosion Risk
Verifyinletpressures.
• High pre ssure ma y c aus e o verfire
condition.
• Lowpressuremaycauseexplosion.
• Verify minimum pressures when other
householdgasappliancesareoperating.
Install regulator upstream of valve if line
pressureisgreaterthan1/2psig.
WARNING
Pressurerequirementsforapplianceareshownintablebe-
low.Minimumpressuresmustbemetwhenotherhousehold
gasappliancesareoperating.
Pressure Natural Gas Propane
MinimumInletPressure 5.0in.w.c. 11.0in.w.c.
MaximumInletPressure 7.0in.w.c. 14.0in.w.c.
Fire Risk
Explosion Risk
Highpressurewilldamagevalve.
• DisconnectgassupplypipingBEFORE
pressure testing gas line at test pressures
above1/2psig.
• ClosethemanualshutoffvalveBEFORE
pressure testing gas line at test pressures
equaltoorlessthan1/2psig.
WARNING
WARNING
CHECK FOR GAS LEAKS
Fire Risk
Explosion Risk
Asphyxiation Risk
• Checkallttingsandconnections.
• Donotuseopename.
• Afterthegaslineinstallationiscomplete,
all connectionsmust betightenedand
checked for leaks with a commercially
available, non-corrosive leak check
solution.Besuretorinseoffallleakcheck
solutionfollowingtesting.
Fittingsandconnectionsmayhaveloosened
duringshippingandhandling.
WARNING
Fire Risk
Explosion Risk
DoNOTchangethevalvesettings.
• This valve has been preset at the
factory.
• Changingvalvesettingsmayresultinre
hazardorbodilyinjury.
Shock Risk
Explosion Risk
DoNOTwire110Vtovalve.
WARNING
• GasSupplyPressure:Minimuminletgassupplypressure
mustbe5in.W.C.fornaturalgasor11in.W.C.forLP
gasforthepurposeofinputadjustment.Maximuminlet
gas pressure must not exceed 7.0 in. W.C. for natural
gasor14in.W.C.forLPgas.Thegaslinesupplyingthe
appliancemustbesufcientsizetofurnishtheappropriate
supplypressuretotheappliancewhileoperatinginthe
“High”setting.
ThesizeandcapacityoftheLPsupplytankmustbeable
tosupplyLPgas,pressureandcapacityforthe180,000
BTU’srequiredtooperatethisappliance.Checkwithyour
LPgassupplierforappropriatesizingoftankandsupply
lines.
• GasLinePressureTest:Performpressuretestaccording
tostateandlocalcode(ifpressureexceeds1/2in.psi[3.5
kPa])beforeapplianceisconnected.Besuretorelease
airpressurefromthegaslinebeforeconnectionismade
totheappliance.Excessivepressurewilldamagethegas
controlandmaycauseagasleak.
• GasLeakTest:Makesurethegasconnectionsaretight.
Turnonthegasandcoateachjointwithanon-corrosive
gasleakchecksolution.Airbubbleswillformindicating
anyleaks.DONOTUSEAFLAMEORANYTYPEOF
IGNITIONSOURCETOCHECKFORLEAKS.Allleaks
mustbecorrectedbeforeproceedingwithinstallation.
11 Quadra-Fire • Fogata Grande October 2006
C. Gas Connection
Note: Have the gas supply line installed in accordance
with local building codes, if any. If not, follow ANSI
223.1.Installationshouldbe donebyaqualiedinstaller
approvedand/orlicensed as required by the locality.(In
theCommonwealthofMassachusettsinstallationmustbe
performedbyalicensedplumberorgastter.)
Note: A listed (and Commonwealth of Massachusetts
approved)1/2in.(13mm)T-handlemanualshut-offvalve
and exible gas connector are connected to the 1/2 in.
(13mm)controlvalveinlet.
If substituting for these components, please consult
local codes for compliance.
WARNING
Fire Risk
Explosion Risk
• Gas build-up during line purge may
ignite.
• Purgeshouldbeperformedbyqualied
technician.
• Ensureadequateventilation.
Ensure there are no ignition sources such
assparksoropenames.
• Incoming gas line should be piped to the 1/2 in.
connection.
• Theapplianceanditsindividualshutoffvalvemustbe
disconnectedfromthegassupplypipingsystemduring
anypressuretestingofthatsystemattestpressures
inexcessof1/2psi(3.5kPa).
• Asmallamountofairwillbeinthegassupplylines.
Whenrstlightingapplianceitwilltakeashorttime
forairtopurgefromlines.Subsequentlightingofthe
logsetwillnotrequiresuchpurging.
WARNING
CHECK FOR GAS LEAKS
Fire Risk
Explosion Risk
Asphyxiation Risk
• Checkallttingsandconnections.
• Donotuseopename.
• Afterthegaslineinstallationiscomplete,
all connectionsmust betightenedand
checked for leaks with a commercially
available, non-corrosive leak check
solution.Besuretorinseoffallleakcheck
solutionfollowingtesting.
Fittingsandconnectionsmayhaveloosened
duringshippingandhandling.
D. High Altitude Installations
OMNIgasappliancesaretestedandapprovedwithoutre-
quiringchangesforelevationsfrom0to2000ftintheUSA
andCanada.
Wheninstallingthisapplianceatanelevationabove2000ft,
itmaybenecessarytodecreasetheinputratingbychang-
ing the existing burner orice to a smaller size. Input rate
shouldbereducedby4%foreach1000ftabovea2000ft
elevationintheU.S.A.,or10%forelevationsbetween2000
and4500ftinCanada.Iftheheatingvalueofthegashas
beenreduced,theserulesdonotapply.Toidentifytheprop-
eroricesize,checkwiththelocalgasutility.
Ifinstallingthisapplianceatanelevationabove4500ft(in
Canada),checkwithlocalauthorities.
12 Quadra-Fire • Fogata Grande October 2006
A. Before Lighting Appliance
• Beforelightingthisappliance,ensurethemanualshutoff
valveisopen.
Fire Risk
Burn Risk
HOT! DO NOT TOUCH.
SEVERE BURNS MAY RESULT.
CLOTHING IGNITION MAY RESULT
Glass and other surfaces are hot during
operationandcooldown.
WARNING
• Keepchildrenaway.
• CAREFULLYSUPERVISEchildreninsameroomas
appliance.
• Alert children and adults to hazards of high
temperatures.
• Keep clothing, furniture, draperies and other
combustiblesaway.
Improper installation, adjustment, alteration, service or
maintenancecancauseinjuryorpropertydamage.Refer
to the owner’s information manual provided with this
appliance.Forassistanceoradditionalinformationconsult
aqualiedinstaller,serviceagencyorthegassupplier.
WARNING
DoNOTusethisapplianceifanyparthasbeenunder
water. Immediately call a qualied service technician
toinspecttheapplianceandtoreplaceanypartofthe
control system and any gas control which has been
underwater.
WARNING
6
Operating Instructions
Before operating this appliance, have a qualied
technician:
• Inspecttheburnerbeforeeachuseofthegaslogset.If
thereisanyevidencethattheburnerisdamaged,itmust
bereplacedbeforeoperating.
• Reviewproperplacementoflogs.
• Ensurethattherearenogasleaks.
• Ensurethattheowofcombustionandventilationairis
notobstructed.
On/Off Switch
Piezo
Valve Control
Knob
The lighting instructions and operation of the unit are
describedonthefollowinginstructionalpageandMUSTbe
followedtoensurethesafeoperationofthisappliance.
WARNING
13 Quadra-Fire • Fogata Grande October 2006
LIGHTING INSTRUCTIONS
MILLIVOLT VALVE
1. STOP! Read the safety information previously listed above.
2. Turn gas control handle clockwise to the ‘OFF” position.
3. Waitve(5)minutestoclearoutanygas.Thensmellforgas,includingneartheoor.Ifyou
smellgas,STOP!Follow“B”inthesafetyinformationaboveonthislabel.Ifyoudon’tsmell
gas,gotothenextstep.
4. Locatepilot(Fig.10)–locatedatcenterofpanburnermountedontherearofthepanburner.
5. Makesuretoggleswitchisinthe“OFF”position(Fig.9)
6. Turn control handle counterclockwise
tothe“PILOT”position(Fig.9)
7. Placealitmatchatthepilotburner,andsimultaneouslypushinonthecontrolhandle.This
shouldignitethepilot.(ifyouhaveoptionalpiezoignitoronpilot,followinstructionsbelow)
8. Oncethepilotlights,continuetodepressthecontrolhandleforone(1)minute.
9. Afteroneminute,slowlyreleasecontrolhandleanditwillpopbackout.Pilotshouldremain
lit.Ifitgoesoutrepeatsteps1thru8.
• Ifthehandledoesnotpopoutwhenreleased,stopandimmediatelycallyourservicetechnician
or gas supplier
• Ifthepilotwillnotstaylitafterseveraltries,turnthegascontrolhandleto“OFF”andcallyour
service technician or gas supplier.
• LIGHTINGPILOTWITHOPTIONALPIEZOLIGHTER
1. Followsteps1thru5above.
2. Push the control handle in and at the same time press the push-button ignitor several times.
This should cause a spark at the pilot burner and ignite the pilot
3. Oncethepilotlights,continuetodepressthecontrolhandleforone(1)minute
4. Afteroneminute,releasecontrolhandleandthepilotshouldremainlit
5. Ifthepilotdoesnotremainlit,rotatecontrolhandleto“OFF”position(Fig.9)
6. Waitve(%)minutesandrepeatabovesteps
10.Turncontrolhandlecounterclockwiseto“ON”
11.Placetoggleswitchinthe“ON”position(Fig.9)
ON
OFF
PILOT
O
N
Pilot
Thermopile
Millivolt
Fig. 10
Turncontrolhandleclockwise to the OFFposition.Donotforce
TO TURN OFF GAS TO APPLIANCE
14 Quadra-Fire • Fogata Grande October 2006
Note: Thisapplianceshouldberunthreetofourhourson
theinitialstart-up.Turnitoffandletitcoolcompletely.This
willhelpcuretheproductsusedinthepaintandlogs.
Fire Risk
Keep combustible materials, gasoline and
otherammablevaporsandliquidsclearof
appliance.
• DoNOTstoreammablematerialsinthe
vicinityoftheappliance.
• Do NOT use gasoline, lantern fuel,
kerosene,charcoallighteruidorsimilar
liquidsinthisappliance.
Combustiblematerialsmayignite.
WARNING
Fire Risk
High Temperatures
Keep combustible household items away
fromappliance.
• Do NOT obstruct combustion and
ventilationair.
• DoNOTplacecombustibleitemsontop
ofornearappliance.
• Keep furniture, draperies away from
appliance.
WARNING
B. After the Appliance is Lit
Initial Break-in Procedure
When you light the appliance, you may notice that it pro-
ducesheatwhichmayhaveanodororsmell.Ifyoufeelthis
odorisexcessiveitmayrequiretheinitialthreetofourhour
continuous burn on high followed by a second burn up to
3hourstofullydriveoffanyodorfrompaintandlubricants
usedinthemanufacturingprocess.
C. Inspection Before Each Use
Beforeeachuseoftheappliance,checktobesurethatthe
logs are in proper locations and that the burner is not ob-
structedwithanyforeignorcombustiblematerials.Check
thattheburnerandallairpassagewaysarekeptclean.
Ifanypartoftheburnerisnotignitingproperly,turnoffthe
appliance.Letitcool,andcheckforanyobstructions.
15 Quadra-Fire • Fogata Grande October 2006
A. Troubleshooting
Withproperinstallationandmaintenance,yournewdecorativegasapplianceshouldprovideyearsoftrouble-freeservice.
Ifyoudoexperienceaproblem,refertothetroubleshootingguidebelow.Thisguidewillassistyouoraqualiedservice
technicianinthediagnosisofproblemsandthecorrectiveactiontobetaken.
Symptoms Possible Causes Corrective Action
1. Amatchorpiezzowillnot
lightthepilot.
A. Maingasshutoffvalveis
closed
1. Makesurethattheshutoffvalvelocatedonthe
incominggaslineisopen.
B. Thereisairinthegasline. 1. Lightamatch.Turnthevalveknobtothe“PILOT”
positionanddepress.Keepthematchnearthepilot
burneruntilitlights.
C. Thevalveknobisinthe
“OFF”position.
1. Turnthevalveknobtothe“PILOT”positionand
depress.Keepthematchnearthepilotburneruntilit
lights.
D. Thepilotoriceisplugged,
notallowinggastoow.
1. Thisrepairrequirestoolsandsomedegreeof
experience.Callaqualiedservicetechnician.
E. Thereisnogassupplyto
thereplace.
1. Checktheplumbingtoensurethereplacehasbeen
hookedupthegassupplyline.
2. Thepropanetankisempty.
2. Thepilotlights,but
willnotstaylitafter
carefullyfollowinglighting
instructions.
A. Thereisaweakpilotame 1. Thepilotamemustengulfthethermocouple.
Cleanand/oradjustthepilotformaximumame
impingementonthethermocouple.
3. Thepilotison,butthereis
nogastothemainburner;
thevalveknobison.
A. Ablockageispreventing
gasow.
1. Inspecttheburneroriceforobstruction.Calla
qualiedservicetechnician.
B. Defectivevalve. 1. Replacethegasvalve.Callaqualiedservice
technician.
7
Troubleshooting
16 Quadra-Fire • Fogata Grande October 2006
Although the frequency of appliance servicing and main-
tenance will depend on use and the type of installation, a
qualied service technician should perform an appliance
check-upannually.
Annual inspection by qualified technician
recommended.
Check:
• Obstructionsofcombustionandventilation
air.
• Conditionoflogs.
• Conditionofburnerassembly.
• Burnerignitionandoperation.
• Burnerairshutteradjustment.
• Gasconnectionsandttings.
Risk of:
Fire
• Delayedignitionorexplosion
• Exposuretocombustionfumes
Odors
WARNING
8
Maintaining and Servicing the Appliance
Risk of injury or property damage
Before servicing:
• Turnoffutilitiestoappliance.
• Ensureapplianceiscompletelycooled.
WARNING
Maintenance and Service Tasks:
Inspect Maintenance Tasks
BurnerAssembly 1 Removelogsandexamineburner.Vacuumandwipeoutdust,cobwebs,debrisorpethair.Usecaution
whencleaningtheseareas.Screwtipsthathavepenetratedthesheetmetalaresharpandshouldbe
avoided.
2 Removeanyforeignobjects
3 Inspectforpaintcondition,warpage,corrosion.Sandandrepaintasnecessary.
4 Verifyunobstructedaircirculation.
Logs 1 Inspectforbroken,damagedormissinglogs.Replaceasnecessary.
2 Verifycorrectlogplacementandnoameimpingementcausingsooting.Correctasnecessary.
3 Verifylogsarecleanandcarbon(soot)free.Logsmaybecleanedwithadrybristlebrushordrycloth.
Handlelogswithcareastheyarefragileandeasilydamaged.
Burnerignitionandoperation
1 Verifyallgasconnectionsaretightandleak-free.
2 Cleanoffburnertopcorrosionordeterioration.Replaceburnerifnecessary.
3 Checkforsmoothlightingandignitioncarryovertoallports.Verifythereisnoignitiondelay.
4 Inspectforliftingorotherameproblems.
5 Inspectoriceforsoot,dirtorcorrosion.
6 Verifymanifoldandinletpressures.Adjustregulatorasrequired.
17 Quadra-Fire • Fogata Grande October 2006
9
Reference Materials
A. Service Parts List
Service Parts
FOGATA GRANDE
# Description of Part Part Number Qty.
1 ValveAssemblyComplete SRV-FG-VA 1
2 Thermopile SRV-FG-THPL 1
3 BurnerAssemblyComplete SRV-FG-BA 1
4 PilotAssembly(withoutThermopile) SRV-FG-PA 1
18 Quadra-Fire • Fogata Grande October 2006
Service Parts
FOGATA GRANDE
# Description of Part Part Number Qty.
1 Log 1 SRV-FG-001 1
2 Log 2 SRV-FG-002 1
3 Log3 SRV-FG-003 1
4 Log 4 SRV-FG-004 1
5 Log5 SRV-FG-005 1
6 Log 6 SRV-FG-006 1
7 Log 7 SRV-FG-007 1
8 Log 8 SRV-FG-008 1
9 Log9 SRV-FG-009 1
Log 1
Log 3
Log 2
Log 4
Log 7
Log 8
Log 9
Log 6
Log 5
B. Logs
19 Quadra-Fire • Fogata Grande October 2006
Service Parts
FOGATA GRANDE
# Description of Part Part Number Qty.
1 Log 10 SRV-FG-010 1
2 Log 11 SRV-FG-011 1
3 Log 12 SRV-FG-012 1
4 Log13 SRV-FG-013 1
4 Log 14 SRV-FG-014 1
5 Log15 SRV-FG-015 1
6 Log 16 SRV-FG-016 1
7 Log 17 SRV-FG-017 1
Log 13
Log 12
Log 11
Log 10
Log 14
Log 15
Log 16
Log 17
B. Logs (continued)
20 Quadra-Fire • Fogata Grande October 2006
C. Limited Lifetime Warranty
Hearth & Home Technologies Inc.
Outdoor Products Limited One Year Warranty
Hearth&HomeTechnologiesInc.extendsthefollowingwarrantyforHearth&HomeTechnologiesoutdoorproducts
usedintheUnitedStatesofAmericaorCanada.DealersandemployeesofHearth&HomeTechnologieshaveno
authoritytomakeanywarrantyorauthorizeanyremediesinadditiontoorinconsistentwiththetermsofthiswarranty.
Thiswarrantygivesyouspeciclegalrights.Youmayalsohaveotherrightsthatvaryfromstatetostate.
Hearth & Home Technologies warrants that this Hearth & HomeTechnologies Outdoor Product (the “Product”) will
befreefromdefectsinmaterialandworkmanshipforaperiodofoneyearfromitsdateofpurchase.Thiswarrantyis
subjecttotheconditions,exclusionsandlimitationsdescribedbelow.
ThiswarrantyappliesonlytotheoriginalowneroftheProductandisnon-transferable.Hearth&HomeTechnologies’
obligation under this warranty does not extend to damages resulting from (1) assembly, operation or maintenance
of the Product not in accordance with the Installation/Assembly Instructions, Operating Instructions and the Listing
AgencyIdenticationLabelfurnishedwiththeProduct;(2)installationorusewhichdoesnotcomplywithlocalbuilding
codesandordinances;(3)shipping,improperhandling,improperoperation,abuse,misuse,accidentorunworkmanlike
repairs;(4)useoffuelsotherthanthosespeciedintheOperatingInstructions;(5)Installationoruseofcomponents
notsuppliedwiththeProductoranyothercomponentsnotexpresslyauthorizedandapprovedinwritingbyHearth&
HomeTechnologies;and/or(6)modicationoftheProductnotexpresslyauthorizedandapprovedinwritingbyHearth
&HomeTechnologies.Anyofthecircumstancesdescribedintheprevioussentencevoidsthiswarranty.Thiswarranty
isvoidiftheProductoranycomponenthasbeenremoved,repaired,orreplacedbeforeHearth&HomeTechnologies
hasbeenaffordedareasonableopportunitytoinspecttheProduct.
Thiswarrantyis limitedtothereplacement orrepairof defectivecomponentsorworkmanship andHearth&Home
Technologies may fully discharge its obligations under this warranty by repairing or replacing, at its discretion, the
defectivecomponents.Hearth&HomeTechnologieswillprovidereplacementpartsatnochargeandwillpayreasonable
andnecessarylaborandfreightcostsrelatedtoreplacingorrepairingdefectivecomponentsunderthiswarranty.The
maximumamountrecoverableunderthiswarrantyislimitedtothepurchasepriceoftheProductand,ifHearth&Home
Technologiesisunabletoprovidereplacementorrepairinanexpedientandcost-effectivemanner,Hearth&Home
TechnologiesmaydischargeallobligationsunderthiswarrantybyrefundingthepurchasepriceoftheProduct.
EXCEPT TO THE EXTENT PROVIDED BY LAW, HEARTH & HOME TECHNOLOGIES MAKES NO EXPRESS
WARRANTIES OTHER THAN THE WARRANTY EXPRESSED HEREIN. THE DURATION OF ANY IMPLIED
WARRANTY IS LIMITED TO THE DURATION OF THE WARRANTY SPECIFIEDABOVE. IN NO EVENT SHALL
HEARTH&HOMETECHNOLOGIESBELIABLEFORANYINCIDENTALORCONSEQUENTIALDAMAGESCAUSED
BYDEFECTSINTHEPRODUCT.Somestatesdonotallowlimitationsonhowlonganimpliedwarrantylasts,ordonot
allowexclusionorlimitationofincidentalorconsequentialdamages,sotheselimitationsmaynotapplytoyou.
To obtain service under this warranty, you must:
1. Sendwrittennoticeoftheclaimedconditionto:TheTechnicalServicesDepartment,Hearth&HomeTechnologies
Inc.,Mt.Pleasant,1915W.SaundersSt.,Mt.Pleasant,IA52641(phone:1-800-927-6841).
2. AfrmthatyouaretheoriginalowneroftheProduct.
3. Provide Hearth & Home Technologies reasonable opportunity to investigate the claim, including reasonable
opportunitytoinspecttheProductpriortoanyrepairorreplacementworkandbeforetheProductoranycomponent
oftheProducthasbeenremoved.
4. ObtainHearth&HomeTechnologies’consenttoanywarrantyworkbeforetheworkisdone.
©2004Hearth&HomeTechnologiesInc. 803-9058/04
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20

Quadra-Fire FG21SP-LP User manual

Category
Fireplaces
Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI