GE AGM06LHG1 Owner's manual

Type
Owner's manual
ge.com
©
©
Safety Instruc_tions ........ 2, 3
Operating Instructions
Control Knob Models ...... 6, 7
Touch Pad Models ......... 4, 5
Care and Cleaning
Air Fil ter .................. 8
Grille and Case ............. 8
Outdoor Coils .............. 8
Installation Instruc_tions
Preparing to Install the
Air Conditioner ............. 9
Window Installation ...... 10-14
Troubleshooting Tips ...... 15
Normal Operating Sounds . . .16
Consumer Support
Consumer Support ......... 20
Product Registration ..... 17, 18
_¢\.wranty ................. 19
A GM06
A GM08
Acqos
A G V08
A GM l 0
A(z)j o
AGWO
A GM 12
A(;oj2
AGVI2
Ac;qz4
AGVI4
©
Write the model and serial numbers here:
Model #
Serial #
Find these ntm_bers on a label on the
side of the air conditione_:
3828A2fO31E 49-7521 11-05JR
iMPORTANTSAFETYiNFORMATiON.
READALLiNSTRUCTiONSBEFOREUSING.
For your safeN the information in this manual must be followed to minimize the risk of fire, electric shock
or personal injury.
SAFETYPRECAUTIONS
_{_:Use this appliance only %r its intended
i)mj)ose as described in tilts )wner s
Manual.
_{::This air conditioner must be properly
installed in accordance with the Installation
Instructions before it is used.
_::Nexer unplug your air conditioner by pulling
on the power cord. Always grip plug firmly
and pull straight out flom the receptacle.
_: Replace immediamlv all electric service
cords dmt haw become flaved or odlerwise
damaged. A damaged power supply cord
must be replaced with a new power supply
cord obtained flom the manufi_CtUler and
not repaired. Do not use a cord that shows
cracks or abrasion damage along its length
or at either die plug or connector end.
qT{_:Turn the unit OFFand unplug your air
conditioner before making any repairs
or cleaning.
NOTE,"Westronglyrecommendthat anyservicing
be performedbya qualified individual.
_:;For your safety...do not store or use
combustible materials, gasoline or other
flammable vapors or liquids in the vicinity
of this or any other appliance.
E:,:All air conditioners contain refl_igerants,
which under federal law must be removed
prior to product disposal. If you are g>tfing
rid of an old product with refl-igerants, check
with the company handling disposal about
what to do.
HOWTOCONNECTELECTRICITY
Do not, under any circumstances, cut or remove
the third (ground) prong from the power cord. For
personal safe_ this appliance must be properly
grounded.
The power cord of dfis appliance is equipped
with a 3-prong (grounding) plug which mates
with a standard 3-piong (grounding) wall
outlet m minimize the possibility of electric
shock hazard flom this appliance.
Power cord includes a ctlnent intenupter
device. A test and reset button is provided on
the plug case. The device should be tested on a
periodic basis by first pressing the rESrbutton
and then the RESErbutton. If the TESrbutton
does not uip or if file RESErbutton will not
stay engaged, discontinue use of the air
conditioner and contact a qualified
service technician.
VO_ere a 9-prong wall outlet is encountered,
it is your persona] responsibility and obligation
to have it replaced with a properly grounded
3-prong wall outlet.
The air conditioner should always be
plugged into its own individual electrical
outlet which has a xoltage rating that matches
the rating plate.
This proxqdes the best perfommnce and also
prexents overloading house wiring circuits
which could cause a fire hazard flom
oxerheated wires.
See the Installation Instructions, Electrical
Requirements section for specific electfica]
connection requirements.
Hme the wall out]et and circuit checked by a
qualified electrician to make sure the outlet is
properly grounded.
2
go.corn
WARNING!
USEOFEXTENSIONCORDS--115-Voltmodelsonly
Because ofpotential safety hazards under certain..ACAUTION:
conditions, we strongly recommend against the
use of an extension cord.
Howexei; if you must use an exmnsion cord,
it is absolutely necessai T that it be a UiAismd,
14 gauge, 3-wire grounding type appliance
extension cord having a grounding type plug
and outlet and that the elecuJcal rating of file
cord be 15 amperes (nfinimum) and 195 x_lts.
DO NOT use an extension cord with any ofthe
230/208 voltmodels.
USEOFADAPTERPLUGS--115-Voltmodelsonly
Because of potential safety hazards under certain
conditions, we strongly recommend against the use
of an adapter plug.
Howe\>i; if yon must use an adaptei; where
local codes i)ermit, a temporaryconnection may
be made to a i)roperly grounded 21)rong wall
on0et 1)yuse of a UiAismd adaptor available
at nlost local hardware stores.
Tile larger slot ill tile adaptor must be alig_led
x_4thfile larger slot in tile wall outlet to provide
proper polarity ill the connection of the
power cord.
When disconnecting fl)e power cold flom tile
adaptei; alwws hold the adapter ill place with
one hand while I)ulling tile I)ower cord I)lug
with the other hand. If this is not done, tile
adaptor ground ml_ninal is x_U liken to bleak
with rei)eated use.
If tile adapter ground tem_inal breaks, DO NOT
USEtile air conditioner until a proper ground
has been established.
Attachingthe adaptergroundterminalto a waftoutlet
coverscrewdoesnotgroundtheapplianceunlessthe
coverscrewis metal,andnotlesulated,andthe waft
outlet is groundedthroughthehousewiring. Youshould
havethecircuitcheckedbya quafifiedelectricianto
makesuretheoutlet is properlygrounded.
READANDFOLLOWTHISSAFETYINFORMATIONCAREFULLY.
SAVETHESEINSTRUCTIONS
Aboutthe controlsontheair conditionermmodels with touchpads.
Features and appearance will vary.
Coolon -
Fanon
Energy
Saveror
Energy
Savored
OR
Coolon 0
@
FAN SPEED
<2Z;_
liNER NODE
E_ERGYSAVER
@
O
@
Air ConditionerControls Remote Control
Controls
O ON/OFF Pad
TtlFIIS air coilditioilei" oi1 aIld ()_.
Oisplav
Shows tile set temperature or time remaining
011 tiIlleI:
O MODE
Use to set tile air conditioner to COOLor
/:AN mode.
Increase •/Decrease Pads
Use to set temperature when in COOLmode.
O FAN Pad
Use to set the fire speed to LOW(FI), MED (F2)
or HIGH (F3).
O ENERGYSAVER(on some models)
Controls tile tim.
ON--The tim and compressor cycle on and
off. This results in wider \m'iations of room
temperature and humidity. Nommllv used
when the room is tmoccupied. NOTE"Thefan
will continuetorun for a shortt/meafter the
compressorcyciesoff.
OFF--The tim rtms all tile time, while tile
compressor cycles on and off.
This fi_atm'e must be set at O/:/:in order to
use tile tim settings (on tile mode control).
NOTE"Onsomemodels,the ENERGYSAVERfeature
cannotbe set on the air conditioner /t mustbe setusing
theremote control.
O CIRCUIJllRE (on some models)
For EOlltiIltlOt/S side-to-side air circulation
(cool settings only), set tile Circulaire switch
to ON.
For fixed side-to-side air direction, mrn ON
tmtil tile desired air direction is obt;fined,
then turn it OFF.
O TIMER Pad
ON--'_._hen tile air conditioner is off, it can be
set to automatically come on in 1 to 12 hours
or 1 to 24 hem's (depending on model) at its
previous setting. Each touch of tile TIMER pad
or tile INCREASE •/DECREASE• pads
(depending on model) will set tile timer
in hours.
OFFi\'_llen tile air conditioner is on, it can be
set to automatically tun_ off in 1 to 12 hem's or
1 to 24 hom_ (depending on model). Each
touch of tile TIMER pad or tile INCREASE /
DECREASE• pads (depending on model) will
set tile till/er ill hotlI_.
Tocancel the timer, press tile 77MERpad /mfil
tile display time disappears.
O Remote Control Signal Receiver
4
Remote Control
::Ji::To ensm'e proper operation, aim tile remote
control at the signal receiver on tile air
Collditiollei:
iJi::Tile remote control signal has a range of
up to 21 feet.
::Ji::Make sure nothing is between tile air conditioner
and the remote control that could block the
signal,
::Ji::Make sure batteries are fl'esh and installed
correctly as indicated on tile remote control.
ge.com
Lights next to the touch pads on the air conditioner
control panel indicate the selected settings.
COOtMode
[)se the COOL mode with HIGH(F3),MED(F2)or
LOW(FI) fm_fiw cooling. Use die/NCREASEA/
BECREASEVpads to settile desired temperature
between 60°F m_d 86°F in 1°F increments.
An electronic thennostnt is used to maintain the
room temperatm'e. The compressor will cyde on
and off to kee I) the room at the set level ot COl/l%II,
Set die theimostat at a lower number and the indoor
air will become coolel; Set the themlostat at a higher
number and the indoor air will become wm reel:
NOTE.."If the air conditioner/L_off and /L_then turnedon
whi/eset to a COOLsett/bg or if turnedfroma fansett/bg
toa COOt sett/bg it wi// takeapprox/nTate/y3 m/butes
forthe compressortostart and coo//bgto beg/b,
Cooling Descriptions
For Nonnal Cooling--Select tile COOL mode and
HIGH(F3)or MEO(F2)fimwith amiddle set
te_//per;fftll'e,
For Maximum Cooling--Select the COOL mode
and HIGH(F3)tim with a lower set temperature.
For Quieter& Nighttime Coolftlg----Select the
COOL m ode and LOW (1:1}fire with a middle set
temperature.
NOTE:If youswitchfroma COOLsett/bgtoOFFertoa fan
sett/bg,waitat least3m/butesbeforeswitch/bgbacktoa
COOLsett/bg.
FAN Mode
Use the FAN at HIGH (1:3),MED (F2)or LOW(FI)to Since tim only settings do not provide cooling,
provide air circulation and filtering without cooling, a temperature setting will not be displayed.
Power Outage Recovery Feature
In the case of a power outage or interruption, the
unit will automatically re-start in the settings last
used alter the power is restored. If the TIMER
teatm'e was set, it will resume its countdown.
_4:,t:lmay need to set a new time if' desired.
Vent Control
The vent control is located above the control
panels.
When set at CLOSE, only the air inside the room
will be circulated and conditioned. _\'hen set at
OPEN,some inside air is exhausted outside.
Toopen the vent, puff the lever toward you.
Toclose it,push it in.
Air Direction--Side-to-Side
The side-to-side air direction is a(!i usted by moving
the lever to the leli or right.
Air Direction--Up and Down
Fingertip pressure on the horizontal louvers
ac!iusts the air direction up or down.
(on some models)
5
Aboutthecontrolson theairconditionermmode/swith controlknobs.
Features and appearance will vary.
OFF
HIGHQcIIGH
FAN OOL
LOW' MED
FAN COOL
LOW
COOL
OFF
FAN OOL
LOW LOW
FAN COOL
MODECONTROLS
Yourmodel will have one of the above type controls.
3 98 2 7 2 5
TEMPCONTROLS
Yourmodel will have one of the above type controls.
Controls
!1
Mode Controls
HIGHCOOL,MED COOLand LOWCOOL
provide cooling with different tim speeds.
FANsettings provide air circulation and
filtering without cooling.
NOTE: If you move the mode control from a cool settlbg
to OFF or to a fan setting,wait at least 3 mlbutes
before switchlbgback to a cool setting.
Cooling Descriptions
ForNormal Cooling--Select HIGHCOOLor MED
COOLwith the temp control at midpoint.
For Maximum Cooling-Select HIGH COOL with the
temp control at the highest nmnber available on
VOIII" knob.
ForQuieter& NighttimeCooling--Select LOW COOL
with the temp control at midpoint.
TempControls
The temp control is used to maim;fin the
room teml)eratm'e. The compressor will c)'cle
on and off to kee I) the room at the same level
of comfort. '_A]_en wm tuYn the knob to a
higher numbex; the indoor air will become
coole_: Tm'n the knob to a lower nmnber and
the indoor air will become wam_e_:
ge.com
Additional controls and important information.
Energy Saver (on some models)
The energy saver switch controls the tim.
0/_-The tim and compressor cycle on and off
together: This results in wider \m_iations of room
temperature and humidity. Nominally used when
the room is unoccupied.
OFF The tim runs all the time, while the
compressor cycles on and off.
This switch must be set at OFFin order to use the
tim settings (on the mode control).
Vent Control
The vent control is located above the
control knobs.
_]_en set at CLOSE,only the air inside the room
will be circtdated and conditioned. _._]/ell set at
OPEN, some inside air is exhausted outside.
Toopenthevent,pullll?elevertowardyou.
Tocloseit,pushit h?.
Air Direction--Side-to-Side
On some models, the side-t(>side air direction is
a(!justed by moving the lever to the left or right.
CIRCULAIRE(on some models)
For fixed side-to-side air direction, set the
Circulaire switch to ON until the desired air
direction is obtained, then move it to OFF.
For continuous side-to-side air drculation (cool
settings only), set the Circulaire switch u) O/V.
CIRCULAIRE
OFF ON
Air Direction--Up and Down
Fingertip pressure on the horizontal lou\'e_ a(!justs
the air direction up or down.
(onsomemodels)
7
Careand cleaning oftheair conditioner.
Grille and Case
Turn the air conditioner ott and remo_,e the To clean, use water and a mild deter ,ent Do not
_lu,, from the wall outlet before cleanin , use bleach or abrasixes.
Outdoor Coils
The coils on the outdoor side of the air conditioner
should be checked regularly: ]f they are dogged
with dirt or soot, they may be protessionally
cleaned.
Air Filter
The _dr filter behind the fi'ont g_ille should be
checked and cleaned at least e\w)' 30 da}'s or
l/]ore o_i_en [_ necessm)'.
Toremove:
I _ ()lit
] Open the inlet grille upward bx _ullino the
bottom of the inlet grille.
] Using the t'd) )tdl u _slighth on the filter
to release it and pull it do_n.
Clean the filter with warm, soapy water= Rinse and
let the filter (by beibre replacing it.
CAUTiON:DoNor
conditioner without a f//terbecausedirt and//nt w///c/og it
andreduceperformance.
8
Installation
Instructions
Air Conditioner
I _-_ Questions? Call 800.GE.CARES (800.432.2737) or Visit our Website at: ge.com
BEFORE YOU BEGIN
Read these instructions completely
and carefully.
IMPORTANT - Savethese
instructions for local inspector's use.
IMPORTANT - Observeall
governing codes and ordinances.
Note to Installer - Be sure to leave these
instructions with the Consumer.
Note to Consumer - Keep these
instructions for future reference.
Skill level - Installation of this appliance
requires basic mechanical skills,
Completion time - Approximately 1 hour
We recommend that two people install
this product.
Proper installation is the responsibility
of the installer.
Product failure due to improper installation
is not covered under the Warranty.
(_ ELECTRICAL REQUIREMENTS
Some models require a 115/120-volt a.c.,
60 Hz grounded outlet protected with a
15-amp time delay fuse or circuit breaker.
The 3-prong grounding plug minimizes the
possibility of electric shock hazard. If the wall
outlet you plan to use is only a 2-prong outlet,
it is your responsibility to have it replaced with
a properly grounded 3-prong wall outlet.
©
Some models require 230/208-volt a.c.,
protected with a time delay fuse or circuit
breaker. These models should be installed
on their own single branch circuit for
best performance and to prevent
overloading house or apartment wiring
circuits, which could cause a possible
fire hazard from overheating wires.
CAUTION:
Do not, under any circumstances, cut or
remove the third (ground) prong from the
power cord.
Do not change the plug on the power cord
of this air conditioner.
Aluminum house wiring may present special
problems--consult a qualified electrician.
TOOLS YOU WILL NEED
Phillips head screwdriver
Flat-blade screwdriver
Pencil Ruler or tape measure
Level Scissors or knife
Power cord includes a current interrupter
device. A test and reset button is provided on
the plug case. The device should be tested on a
periodic basis by first pressing the TEST button
and then the RESET button, If the TEST button
does not trip or if the RESET button will not stay
engaged, discontinue use of the air conditioner
and contact a qualified service technician.
I
9
Installation Instructions
PARTS INCLUDED
(Appearance may vary)
Left
accordion Top
panel mounting
seal strip Top
mounting
rail
Foam top
window gasket
Window
Frame guide (2)
_--Sill support (2)
Window locking
bracket
Right
accordion
panel
Type A (16)
Type B (3)
Type C(5)
Nut(2)
Bolt(2)
10
Installation instructions
[] WINDOW REQUIREMENTS
These instructions are for a standard
double-hung window. You will need to
modify them for other types of windows.
The air conditioner can be installed
without the accordion panels if needed
to fit in a narrow window. See the
window opening dimensions.
All supporting parts must be secured
to firm wood, masonry or metal.
The electrical outlet must be within
reach of the power cord.
6,000, 8,000 and 10,000 BTU models
(See last illustration for AGM 10 dimensions)
[ J
B===8
14" iTdn.
22" to36"
(Withaccordionpanels)
i
J
19"loin.
(Withoutaccordionpanels)
AGM 10, 12,000 and 14,000 BTU models
16"rain.
27" to39"
(Withaccordionpanels)
[
,I P
24" mio.
(Withoutaccordionpanels)
[]
STORM WINDOW REQUIREMENTS
A storm window frame will not allow the
air conditioner to tilt toward the outside,
and will keep it from draining properly.
To adjust for this, attach a piece of wood
to the stool.
WOOD PIECES-
WIDTH: 2"
LENGTH: Long enough to fit inside the
window frame.
THICKNESS: To determine the thickness,
place a piece of wood on the stool to
make it 1/2" higher than the top of the
storm window frame.
Attach securely with nails or screws
provided by the installer.
+
1/2" hi
than frame Stool
Storm
window
fra me
11
Installation Instructions
[] REMOVE THE AIR CONDITIONER
FROM THE CASE
IAq Remove the 2 shipping screws from the
L_J
back of the case.
FSq Remove the 2 screws on each side of the
L_J
case. Keep these for later use.
Shippingscrews
[] Slide the air conditioner from the case by
gripping the base pan handle and pulling
forward while bracing the case.
[] PREPARE THE WINDOW AND
THE CASE
[] Cut the window sash seal to the proper
length. Peel off the backing and attach the
seal to the underside of the window sash.
[] PREPARE THE WINDOW AND
THE CASE (CONT.)
[] Carefully insert the plastic frame guides
into the bottom of the case on each side.
Bottom 0[ case /,,_,_
\
_ Frameguide
[] Remove the backing from the top mounting
rail seal strip and attach it to the bottom of
the top mounting rail.
[]
Install the top mounting rail with 3 type A
screws on the inside of the case. Insert the
frames for the accordion panels into the top
mounting rail and the frame guides. Attach
the accordion panels to the side of the case
using 4 type A screws on each side.
Topmountingrail
guides
12
Installation Instructions
[] INSTALL THE CASE IN THE
WINDOW
[] Open the window and mark the centerline
of the window stool.
[] Carefully place the case on the window
stool and align the center mark on the
bottom front with the centerline of the stool.
[]
Pull the window down behind the top
mounting rail.
NOTE: Do not shut the window so tightly that
movement of the accordion panels is
restricted.
[] Loosely assemble the sill supports.
INDOOR OUTDOOR
Sillsupport
[]
Select the position that will place the sill
supports near the outermost point on the
sill. Attach the sill supports to the case track
hole in relation to the selected position
using 2 type A screws in each support.
Frameguide
[] INSTALL THE CASE IN THE
WINDOW (CONT.)
[] Adjust the bolt and the nut in each support
so that the case is installed with a slight tilt
to the outside. Use a level; about 1/3 bubble
will be the correct case slant to the outside.
[] Secure the case to the window stool by
using 3 type B screws.
[] Pull the accordion panels to each window
sash track. Attach them on each side to the
window sash and the window stool using
4 type C screws.
13
Installation Instructions
[] INSTALL A SUPPORT BRACKET
AND THE FOAM TOP WINDOW
GASKET
[] Attach a support bracket with a Type C
screw.
[] Cut the foam top window gasket to the
window width.
[] Stuff the foam between the glass and the
window to prevent air and insects from
getting into the room.
/
[] INSTALL THE AIR CONDITIONER
IN THE CASE
I_q Slide the air conditioner into the case.
Inl
Reinstall the 2 screws removed earlier on
each side of the case.
[] Before installing the front grille, pull out the
vent control lever located above the unit
control knobs, as shown.
[]
Attach the front grille to the case by inserting
the tabs on the grille into the slots on the
front of the case. Push the grille in until it
snaps into place.
[]
Guidethe lever carefully
flTroughflTegrille as you
push it in.
Lift the inlet grille and secure the front
frame with a type A screw through the
front grille. Lower the inlet grille back into
place.
14
TroubleshootingTips. re.corn
Troubleshooting -tips.Save time and money! Review the chart below
first and you may not need to carl for service.
Possible Causes What ToDo
Airconditioner
doesnotstart
The air conditioner
is unplugged.
Make sure the air conditioner plug is pushed completely
into the outlet.
The fuse is blown/circuit Check the house fllse/circuit breaker box and replace
breaker is tripped, the fllse (1i"reset the breakei:
Power failure. The unit will automatically re-start in the settings last
used after the power is restored.
There is a protective time delay (approximately
3 minutes) to prevent tripping of the compressor
overload. For this reason, the unit may not start
normal cooling fin" 3 minutes alter it is turned
back on.
The current interrupter Press the RESETbutton located on the power cord plug.
device is tripped. If the RESffrbuttou will not stay euml,red discoutiuue
use ot the air conditioner and contact a qualified selMce
tech nicia n.
Air conditioner does not Airflow is restricted. Make st11"ethere are no curtaius, blinds o1"flu'uiture
cool as it should bh)cking the ti'(mt of the air c(mditionel:
The temp control may not On models with touch pads:/n COOLmode, press the
be set correctly. DECREASEVl)a d.
On models with control knobs, turn the temperature
knob to a higher ut/Illbel:
The air Filter is dirt,i. Clean the filter at least evel]' 30 days.
See the Operating Instructions section.
The room may have been hot. _A]mn the air conditioner is filet turned on, you need to
allow tiule tot the 1"oo1//to COO1 dowu.
Cold air is escaping. Check ti)r open flU'hate floor registels and cold air l'ettwus.
Set the air conditioner's vent to the closed position.
Cooling coils have iced up. See "Air conditioner freezing up" below.
Air conditioner Ice blocks the air flow and On models with control knobs, set the mode control at
freezing up stops the air conditioner HIGHFANor HIGH COOLwith the tern 1)at I or 2.
from cooling the room. On models with t(>uch pads, set the c(mtr(>ls at
HIGH (F3)FAN or HIGH (F3)COOLand set the them, ostat
to a higher temperature.
The remote control The batteries are hzserted Check the l)osifion of the batteries. They should be
is not working incorrectly, inserted in the opposite (+) and (-) direction.
The batteries may be dead. Replace the batteries.
Water drips outside Excessively hot and This is n(mnal.
hmnid weather.
Water drips indoors The air conditioner is not For l)roper water disposal, make sure the air conditioner
tilted to the outside, slants slightly t]'oul the case ti'ont t(> the rein:
Water collects in Moisture is removed from This is nom, al tiw a short period in areas with little
base pan indoor air and drahls into htunidity; nomml for a hmger pelJod in re1T humid areas.
rear of a cabinet where a fml
blows it against the outdoor
condenser coil.
TIMERfeature not A power outage or interruption In the case of a power outage o1"interruption, the unit
working properly occurred. HMER ti_ature toll reset to the original setting. _A)u may
need to set a uew time if desired.
/5
Troubleshootingtips.
Normal Operating Sounds
_: Ym may hear a pinging noise caused by water being
picked up and thrown against tile condenser on rainv
days or when tile humidi V is high. This design teatm'e
helps remove moistm'e and improve efficiency.
::Ji::Ym may hear the them/ostat click when the compressor
cycles on and off.
!i?:X4_Ker will collect in tile base pan dufin(*_ high, hmniditv
or on rain) days. The water inav oxerflow and drip fl'om
tile outdoor side of tile trait.
iJi::Tile lilil ill}l] i'[in exen when tile COilll)i'essoi" does not,
16
GE Service Protection Plus 'M
GE, a name recognized _,_orldwide for quality and dependability; o£%rs yon
Service Protection Plns'_'--comprehensive protection on all y'om appliances--
No Matter What Brand!
Benefits Include:
. Backed by GE
. All brands covered
* Unlimited service calls
o All parts and labor costs included
o No out-of-pocket expenses
o No hidden deductibles
* One 800 number to call
We 71 Cover Any Appliance.
Anywhere. Anytime.
You will be completel} satisfied with ore" service protection or ",ou ma} request yore" mone} back
on the remaining value of)our contract. No questions asked. IVs that simple.
Protect yoltr refrigerator, dishwasher, washer and dryer, range, TV; VCR and much more--any brand!
Plus there's no extra charge tor emexgency service and low monthly financing is available. Even icemaker
coverage and toed spoilage protection is offered. You can rest easy, knowing that all your valuable
household products are protected against expensive repairs.
Place ,,our confidenre in (liE and call us in the IJ.S. toll-free at _UU,OZ_,ZZZz]:
for n/ore inforI//atioll.
,M1 brands (o_erecl, tip to 20 years old, in the (ontinem d U.S.
_ (]tll hel-e
Please place in envelope and mail to:
General Electric Company
Warranty Registration Department
EO. Box 32150
Louisville, KY 40232-2150
77
Consumer Product Ownership Registration
Dear Customer:
Thank you tbr purchasing our product and thank you for placing your confidence in tts.
VVeare proud to haxe you as a customer'.
Follow these three steps to protect your new appliance investment:
Complete and mail
your Consumer
Product Ownership
Registration today.
ttavc tim peace ot
mind of knowing we
C_lll COllt_lct VOll ill
the tmlikel_ e_ent of a
sat_w modification.
LMtel- mailing tile
registration below,
store this (l()clllllell_
in a salb place. It
contains inf_)rmation
you will need should
you require selwice.
Our serxice nmnber is
800.GE.CARES
(800.432.2737).
Read your Owner's
Manual carefillly.
It will help you
operate yore- new
appliance properl>
Model Number Serial Number
I I I
Important: If you did not get a registration card with your
product, detach and return the form below to
ensure that your product is registered, or register
online at ge.com.
,_Cm h(r(
Consumer Product Ownership Registration
Model Number Serial Number
Mr. Ms. M*s. Miss
Fil"q I I L_slI
Naln( I I I I I I I I I Nalne I I I I I I I I I I I I
Str(!el [
Addr( ss I I I I I I I I I I I I I I I I I I I I I I I I
Apt. # [ [ [ [ [ I I I [ E-lnail Address:
1)m('Placed t)holle
'"_'_1 , I ,,_,,I , I _,,_,rl, I _.m,er II , , II , , ' IMonth I I
/8
GE Consumer & Industrial
Appliances
General Electric Compan U
Louisville, KY40225
ge.com
* Please provide your e-mail address to receive, via e-mail, discounts, special ottk,p, and other
important communications trom (;E Appliances (GEA).
[ Check here if vou do not want to receive communications ti-om GEA's careflflly selected
p_lrt llers.
FAILI HZE T() COMPI.ETE AND RE'F[ RN Tt tIS CARD DOES NOT DIMINISII YOI JR
"_,I\RRAN'V'; RIGIITS.
For intk)rmation about GEA's pri_acy and data usage polic% go to ge.com and click on 'Pri_acy
Policy" or call 800.626.2224.
GEAir ConditionerWarranty.
Aft warranty service provided by our Factory Service Centers,
or an authorized Customer Care®technician. Toschedule service,
on-line, 24 hours a day, visit us at ge.com, or carl 800.GE.CARES
(800.432.2737).Please have serial number and model number
available when calling for service.
Staple your receipt here.
Proof of the original purchase
date is needed to obtain service
under the warrantz
Fromthedateof the
eriginalpurchase
Fromthedateof the
originalpurchase
GEWill Replace:
Anypart of the air conditioner which flfils due to a defect in materials or workmanship.
During this lim#ed one-year warranty, (;E will also proxide, free of charge, all labor and related
serxice to replace the (lefectixe part,
Any part ofthe sealed refrigerating system (the compressor; condenser; evaporator and
all com_ecting tubing) which tifils due to a delbct in materials or workananship. During this
four-year limited additional warranty, GE will also pr()vide, free of charge, all labor and related
service to replace the delbcti\'e part.
_: Service trips to your home to teach you how to
use the product.
iJi_:hnproper h_staJlation, delivery or maintenance. If you
have ml installation problem, or if the air conditioner
is of improper cooling capacity for the intended use,
contact your dealer or installer. You m'e responsible
for providing adequate electrical cmmecth_g facilities.
::Ji_:Failure of the product resuith_g from modifications to
the product or due to mlreasonable use including failure
to provide reasonable and necessary mah_tenm_ce.
::Ji_:In commercial locations labor necessary to move the
mlit to a location where it is accessible for service
by an individual technician.
!i_Replacement of house fuses or resetting of circuit
breakers.
::Ji::FaJhtre due to corrosion on models not corrosion-
protected.
_: Dmnage to the product caused by hnproper power supply
voltage, accident, fire, floods or acts of God.
::Ji::Incidental or consequential damage caused by possible
defects with this air conditioner.
!i_Dmnage caused after delivery.
iJi::Product not accessible to provide required service.
EXCLUSION OFIMPLIED WARRANTIES--Your sole and exclusive remedy is product repa# as provided in this
Limited Warranty. Any implied warranties, including the implied warranties of merchantability or fitness for a
particular purpose, are limited to one year or the shortest period allowed by law.
This warranty is extended to the original purchaser and any succeeding owner for products purchased for home
use within the USA. If the product is located in an area where service by a GE Authorized Servicer is not available,
you may be responsible for a trip charge or you may be required to bring the product to an Authorized GEService
location for service. In Alaska, the warranty excludes the cost of shipping or service calls to your home.
Some states do not allow the exclusion or limitation of incidental or consequential damages. This warranty gives
you specific legal rights, and you may also have other rights which vary from state to state. Toknow what your
legal rights are, consult your local or state consumer affairs office or your state's Attorney General
Warrantor: General Electric Company. Louisville, KY 40225
19
ConsumerSupport.
I GEAppliancesWebsite ge.com
Hale a question o_ need assistance xdth }our appliance? %'7 tlle (;E Appliances _ ebsite 24 hom_ a day,
, , , )" i /all_ (lax ( f tile xeaA': For greater conxelliellce alld [hster service, Xo/A can llOW downlotd ()WlleA's ]\/lallH/Is,
o " s i.
order parts, cat, dogs, or exen schedule service on-line. You can also ",_sk Ore" Team f Expell.
}our questions, alld so n/Hch In(we...
ScheduleService
Expexl GE repair service is onl} one step awa} flx)m }our dotm Get on-line and schedule xotu" serx]ce at
xotn', convenience 24 hom_ an} da} of the }ear! Or call 800.(;E.(;,_RES (800.432.2737) dining noHnal
BHsilIess llOHl_.
go,corn
RealLifeDesignStudio ge.com
GE suppolnrs tile IJnixvl_al Design concept--products, services and environments their can be used bv
people (d all ages, sizes and capabilities. We recognize the need to design tiw a wide range Aftphysical and
mental abilities and impaim_ents. For derails of GE's Llnivel_al Design applications, including ldtchen
design ideas fiw people with disabilities, check out our Website today. For the heating impaired, please call
800.TDD.GEAC (800.833.4322).
ExtendedWarranties
go.corn
Purchase a GE extended warrant} and learn about special discounts that are available while }our warrant}
00 "_ " __
is still in effect. You can pro'chase it on-line am'time or call 8 .626.2224 dmJng normal business hours.
GE Consumer Home Services will still be there after }our _arrant} expires.
PartsandAccessories
go.corn
Individuals qualified to service their own appliances call have pails or accessories sent directly to their
homes (VISA, MasterCard and Disco\ er cards are accepted). Order on-line toddle, 24 ll(_tn_ e\vl)' clay
Or 1)} r phone at 800.626.2002 during n(mnal business horn's.
Instructions contained in this manual cover procedures to he performed by any user. Other servicing generally
should he referred to qualified service personnel. Caution must he exercised, since impreper servicing may cause
unsafe operation.
ContactUs
go.corn
If you are not satisfied with the service you recei;v fl'om GE, contact us on our Website with all tile details
including yore" phone numbeA; or write to: General ManageA; Customer Relations
GE Appliances, Appliance Park
Ix_uisville, KY 40225
q RegisterYourAppliance
Register your new appliance oil-lille--at your coilvenieilce! Timel} product registration will allow fiw
' enhanced commtmication and prompt serxice trader the temls of }our x_arranty, should tile need alJse.
You max also mail in tile pre-plinted registration card included in tlle l)acldng, mateAial.
go.corn
20 Printed in China
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20

GE AGM06LHG1 Owner's manual

Type
Owner's manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI