DEVI 140F1137 Installation guide

Type
Installation guide
www.DEVI.com
Installation Guide
DEVIlink™ RS
Room Sensor
^
^
+
-
+
-
^
^
^
^
^
^
21,5
^
^
^
^
^
^
DEVIlink™ RS is a battery oper-
ated room device. It measures
the ambient room temperature
and allows you to control
heating
Turn the
device
around
Mount in
height of
80-150 cm
IP21
Mount at least 50 cm from
windows/doors that will be
left open occasionally
Remove the
back panel by
gently pressing your
thumbs on the panel
and pull downwards
Fix the back
panel to the
wall
Install the front
by gently letting
it slide on the
back panel again
Adding DEVIlink™ RS to
a system is made from the
DEVIlink™ CC. For further
information, see separate
instruction.
Avoid direct
sunlight to
DEVIlink™ RS
Tamper-proof,
locked
Mount max. 5 to
6m from living
connect®
DEVIlink™ RS
Installation Guide2
Display information
Ambient temperature
Floor temperature
Short green flash Not included in network
Green fast flash Inclusion in progress
Red flash +
for 5 seconds
Inclusion failed
ON
Link test in progress
Red flash +
for 5 seconds
Link test failed
ON + Red LED flash
every 2½ min.
Low battery level
ON + Red LED flash
every 30 seconds
Critical battery level
E5 Floor sensor short circuited
E6 Floor sensor lost
ON
Tamper-proof enabled by
DEVIlink™ CC
Flash
Limited by DEVIlink™ CC
DEVIlink™ RS
3Installation Guide
Technical specifications
Battery Alkaline 2 x AA, 1.5 V
Battery lifetime Up to 4-5 years
Backlight Green LED
Ambient temperature 0 to +40 ˚C
Battery monitoring
The sensor has a built-in moni-
toring circuit, which will detect
low or critical battery level
Transmission frequency 868.42 MHz
Transmission range in normal
buildings
Up to 30 m
Transmission power Max. 1 mW
IP class 21
Dimensions (mm) 75 x 75 x 24
Radio Equipment Directive
SIMPLIFIED EU DECLARATION OF CONFORMITY
Hereby, Danfoss A/S declares that the radio equipment type DEVI-
link™ RS is in compliance with Directive 2014/53/EU
The full text of the EU declaration of conformity is available at the
following internet address: devi.danfoss.com
DEVIlink™ RS
Installation Guide4
DEVIlink™ RS
5Installation Guide
DEVIlink™ RS
Installation Guide6
DEVIlink™ RS
Danfoss A/S
Electric Heating Systems
Ulvehavevej 61
7100 Vejle
Denmark
Phone: +45 7488 8500
Fax: +45 7488 8501
Web: www.DEVI.com
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss
reserves the right to alter its products without notice. This also applies to products already on order provided that
such alterations can be made without subsequential changes being necessary in specifications already agreed. All
trademarks in this material are property of the respective companies. DEVI and the DEVI logo-type are trademarks of
Danfoss A/S. All rights reserved
08095916 & VICKC402 © Danfoss | 07/2017
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

DEVI 140F1137 Installation guide

Type
Installation guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI