Mirabelle A7242OMIRBS Installation guide

Type
Installation guide
www.mirabelleproducts.com
INSTALLATION AND OPERATING MANUAL
READ THESE INSTRUCTIONS COMPLETELY BEFORE INSTALLING THE PRODUCT. FOR PRODUCT OR
INSTALLATION QUESTIONS PLEASE CALL CUSTOMER SERVICE AT 1-800-221-3379.
YOU MUST FOLLOW ALL INSTRUCTIONS IN THIS MANUAL: FAILURE TO DO SO WILL RESULT IN YOUR
ASSUMPTION OF LIABILITY AND WILL VOID WARRANTY AND CAN RESULT IN PRODUCT DAMAGE OR
PERSONAL INJURY.
FAILURE TO USE A SUITABLE SETTING COMPOUND WILL VOID THE WARRANTY.
THIS PRODUCT IS DESIGNED TO BE INSTALLED BY A LICENSED TRADESMAN. LICENSED PLUMBERS AND
ELECTRICIANS SHOULD BE EMPLOYED TO INSURE PROPER INSTALLATION. INSTALLERS ASSUME ALL LIABILITY
FOR THE CORRECT INSTALLATION PROCEDURES.
Only accessories authorized by the manufacturer should be used with this product. This product is designed for
residential use and use by healthy individuals.
IMPORTANT SAFETY INSTRUCTIONS: WARNING! WHEN USING THIS PRODUCT, BASIC PRECAUTIONS SHOULD
ALWAYS BE FOLLOWED. READ AND FOLLOW ALL INSTRUCTIONS PERTAINING TO RISK OF FIRE, ELECTRIC
SHOCK, OR INJURY TO PERSONS.
INSTALLER: LEAVE THIS MANUAL FOR HOMEOWNER.
HOMEOWNER: READ THIS MANUAL AND KEEP FOR FUTURE REFERENCE.
TABLE OF CONTENTS
Important Safety Information 1
Recommended Tools and Material 2
Inspection & Testing 2
Electrical Requirements & Information 3
Framing & Installation 5
Rough-in Dimensions 7
Care & Cleaning/Maintenance 9
Operating Instructions 9
Troubleshooting 12
Warranty 12
Cut-Out Templates 13
www.mirabelleproducts.com
www.mirabelleproducts.com
3
IMPORTANT SAFETY INSTRUCTIONS
SAVE THIS MANUAL: RETAIN FOR CONSUMER’S USE. READ THESE INSTRUCTIONS
COMPLETELY BEFORE INSTALLING THE PRODUCT: FOR PRODUCT OR INSTALLATION
QUESTIONS PLEASE CALL CUSTOMER SERVICE AT 1-800-221-3379.
YOU MUST FOLLOW ALL INSTRUCTIONS IN THIS MANUAL: FAILURE TO DO SO WILL RESULT
IN YOUR ASSUMPTION OF LIABILITY AND WILL VOID WARRANTY AND CAN RESULT
IN PRODUCT DAMAGE OR PERSONAL INJURY. FAILURE TO USE A SUITABLE SETTING
COMPOUND WILL VOID THE WARRANTY.
THIS PRODUCT IS DESIGNED TO BE INSTALLED BY A LICENSED TRADESMAN. LICENSED
PLUMBERS AND ELECTRICIANS SHOULD BE EMPLOYED TO INSURE PROPER INSTALLATION.
INSTALLERS ASSUME ALL LIABILITY FOR THE CORRECT INSTALLATION PROCEDURES.
Only accessories authorized by the manufacturer should be used with this product.
This product is designed for residential use and use by healthy individuals.
IMPORTANT SAFETY INSTRUCTIONS
WHEN USING THIS PRODUCT, BASIC PRECAUTIONS SHOULD ALWAYS BE FOLLOWED.
READ AND FOLLOW ALL INSTRUCTIONS PERTAINING TO RISK OF FIRE, ELECTRIC SHOCK,
OR INJURY.
IMPORTANT SAFETY INSTRUCTIONS
INSTRUCTIONS PERTAINING TO A RISK OF FIRE, ELECTRIC SHOCK OR INJURY TO PERSONS
READ AND FOLLOW ALL INSTRUCTIONS!
Risk of personal injury. Do not permit children to use this unit without adult supervision.
Risk of personal injury. Do not operate this unit without the guard over the suction tting.
Risk of electric shock. Do not permit electrical appliances (hair dryer, telephone, radio, etc.)
within 60 inches (1524mm) of this unit.
Risk of hyperthermia and possible drowning. People using medications and/or having adverse
medical history should consult a physician before using this product.
Risk of personal injury. Do not overll unit before entering. Entering tub when lled more than
2/3 can cause overow and slippery conditions. Exercise caution when entering and exiting.
No Food or Alcoholic Beverages. Use of your bathtub immediately after meals is not
recommended. Avoid alcohol consumption before or during bathing. Alcoholic beverages can
cause drowsiness or hyperthermia resulting in loss of consciousness or even drowning.
Pregnancy. If you are or think you may be pregnant, consult your physician before using the
bathtub. Never drop or insert any object into any opening. Use this unit only for its intended use
as described in this manual. Do not use any attachments not recommended by Mirabelle.
This equipment is intended for indoor use only.
WARNING
WARNING
WARNING
WARNING
WARNING
WARNING
WARNING
WARNING
WARNING
WARNING
www.mirabelleproducts.com
4
The unit must be connected only to a supply circuit that is properly protected by a 20 amp ground-fault circuit interrupter (GFCI). Such a GFCI
should be provided by the installer and should be tested on a routine basis. To test the GFCI, push the test button. The GFCI should interrupt
power. Push the reset button. Power should be restored. If the GFCI fails to operate in this manner, the GFCI is defective. If the GFCI interrupts
power to the bathtub without the test button being pushed, a ground current is owing, indicating the possibility of an electric shock. Do not
use this total massage, whirlpool or air bathtub. Disconnect The total massage, whirlpool or air bathtub and have the problem corrected by a
licensed electrician before using.
A pressure wire connector is provided on the exterior of the motor unit to permit connection of a no. 8 AWG solid copper bonding
conductor between this unit and all other electrical equipment and exposed metal in the vicinity, as needed to comply with local
requirements. To reduce the risk of an electric shock, connect this connector to the grounding terminal of your electric service or supply panel
with a conductor equivalent in size to the circuit conductors supplying this unit. Use supply wires that are suitable for 167°F (75°C), including
the temperature rating of the supply conductors to be used. Building materials and wiring should be routed away from the motor/pump or
blower or other heat producing components of this unit.
Recommended Tools and Material
Important Safety Instructions
Silicone sealant
Tape measure
• Pencil
Safety glasses
Pipe wrench
• Level
Conventional woodworking
tools and materials
Drop cloth
2x4’s
• Mortar
Optional: construction adhesive
Inspection and Testing
Each bath arrives ready for installation, completely equipped with the pump and plumbing necessary for operation. However, a drain/
overow kit is required for each bath and it is not included.
The variety of installations for this bath may require framing procedures other than those shown.
Locate studs as required. Ensure roughing-in dimensions (see pg. 11) are proper, plumb, and square.
Inspection:
Remove the bath from the carton. Retain the shipping carton until satisfactory inspection of the product has been made. Do not lift the bath
by the plumbing at any time; handle by the shell only. All bath units are factory tested for proper operation and watertight connections
prior to shipping.
Inspect the shell and bathtub components. Should inspection reveal any damage or defect in the nish or visible damage to any
components, do not install the bathtub. Damage or defect to the nish claimed after the bathtub is installed is excluded from the warranty.
Inspect the tub components for loose ttings.
Testing:
Prior to installation and before enclosing with wallboard, tile, etc., the bath must be lled with water and operated to check for leaks that
may have resulted from shipping damage or mishandling.
It is the responsibility of the installer to thoroughly test the tub prior to completing installation. Place the tub on a level surface, ensure
drain is sealed and ll the bathtub with water to the bottom of the overow. Allow water to sit in tub for at least 5 minutes as a static test. If
installing a system tub, plug in the motor/ pump and turn it on. Conrm all features function correctly. Visually inspect all joints for leaks.
DO NOT install tub if any leaks are detected or system functions do not work properly.
www.mirabelleproducts.com
5
Electrical Requirements and Information
ALL CONNECTIONS MUST BE GFCI (Ground Fault Circuit Interrupted) PROTECTED
1. Whirlpool and Total Massage units require dedicated 20 Amp,
120V service.
2. You must provide a receptacle with a 20-amp conguration.
3. See local codes for proper wire size. If not specied, use #12 Copper only wire.
4. Optional In-Line Heater requires its own dedicated 20 amp service.
The unit must be connected to a circuit interrupter (GFCI) provided by the installer. The (GFCI) breaker should be
tested on a routine basis.
To test the (GFCI) breaker, push the test button. The GFCI should interrupt power. To restore power, push the RESET
button. If the GFCI fails to operate in this manner there is ground current owing, indicating the possibility of an
electrical shock. Do not use the unit. Disconnect the unit and have the problem corrected by a qualied service
representative before using.
DANGER
DANGER
RISK OF ELECTRICAL SHOCK. All pumps and blowers must be connected
to a ground fault circuit interrupter (GFCI) protected outlets. Standard Line
Total Massage units can be operated on a single service. All heaters must be
connected to a ground fault circuit interrupter (GFCI) protected outlets, separate
from the pump and/or blower.
Electrical outlet must be mounted 4” (101mm) above the oor line and 12’’
max (305mm) inside from the edge of the bathtub, or in accordance with local
building and electrical codes.
Risks of component over heat. Do not use electric extension cord to power
the unit. Operating the pump without enough water in bathtub can cause
permanent damage to the pump/motor.
If CFGI unit indicates a malfunction, per manufacturers instructions, turn OFF
power and do not attempt to use the bathtub until the source of the problem
has been identied and corrected.
www.mirabelleproducts.com
6
Electrical Congurations
TOTAL MASSAGE CIRCUIT WITH OPTIONAL HEATER
PUMP FLOW
CONTROLL VALV E
0.5 AMP
BACK OF 6 BTN CONTROL
PIGGY BLOWER
9.5 AMP
TMS - VARIABLE
CONTROL
TMS-P/TIMER
CONTROL
ON / OFF PUMP
9 AMP
OPTIONAL
120V, 60 HZ
20 AMP GFCI
120V / 20AMP
MALE PLUG
GFCI GFCI
ELECTRICAL
FEED
120V, 60 HZ
20 AMP GFCI
HEATER
AIR SPEED WAVE
SPEEDJETS WAVE
WHIRLPOOL CIRCUIT WITH OPTIONAL HEATER
PUMP FLOW
CONTROLL VALV E
0.5 AMP
TMS-P/TIMER
CONTROL
ON / OFF PUMP
9 AMP
OPTIONAL
HEATER
120V, 60 HZ
20 AMP GFCI
120V / 20AMP
MALE PLUG
GFCI GFCI
ELECTRICAL
FEED
120V, 60 HZ
20 AMP GFCI
BACK OF 3 BUTTON CONTROL
AIR MASSAGE CIRCUIT
PIGGY BLOWER
9.25 AMP
TMS - VARIABLE
CONTROL
120V, 60 HZ
20 AMP GFCI
GFCI GFCI
ELECTRICAL
FEED
120V, 60 HZ
20 AMP GFCI
GFCI GFCI
ELECTRICAL
FEED
BACK OF 3 BUTTON CONTROL
120V, 60 HZ
20 AMP GFCI
GFCI GFCI
ELECTRICAL
FEED
120V, 60 HZ
9.25 AMP
HEATER
PIGGY BLOWER
9.5 AMP
AIR SWITCH
ON / OFF PUMP
9 AMP
AIR SWITCH
CONTROL BOX
CONTROL BOX
PIGGY BLOWER
9.5 AMP
PUMP / MOTOR
120V, 60 HZ
20 AMP GFCI
GFCI GFCI
ELECTRICAL
FEED
AIR SWITCH
AIR SWITCH
BRADENTON & PROVINCETOWN TOTAL MASSAGE
CIRCUIT WITH OPTIONAL HEATER
BRADENTON & PROVINCETOWN
AIR BATH CIRCUIT
BRADENTON & PROVINCETOWN WHIRLPOOL
WITH INSTALLED AIR SWITCH
POWER SPEED WAVE
POWER SPEED WAVE
www.mirabelleproducts.com
7
Framing and Installation
Structural measurements should be veried against the actual bath received to ensure proper t.
Never lift the tub by the plumbing. Doing so can result in leaks.
Check if the oor is level and of good quality. An uneven oor may impede proper installation of the tub.
Clean installation area of any debris or trash.
Locate studs as needed. Ensure roughing-in dimensions are proper, plumb and square. Provisions must be made in all installations for an
access opening for servicing the pump and controls on the pump or blower side.
An access opening of at least 18’’ x 24’’ must be provided or warranty service will not be performed. It is strongly recommended that an
additional opening be provided for access to the drain components. The apron should not be used as the primary access opening.
If the suboor is not level, you must level the entire surface prior to installing the bathtub.
Ensure that the entire oor is level and can support a load of 80lbs. per square foot.
The bathtub must remain level in order for it to drain properly and must make contact with the leveling material.
1. Position the tub into the installation opening and level the deck in both directions, shimming the base of the tub if necessary. Mark the nal
position of the underside of the deck by tracing a line on to the studs (see Figure 1).
2. Remove the tub and attach a 1 x 4 stringer to the studs, with the top of the stringer touching the traced line. Never support the tub by its
deck lip or stringers (see gure 2).
3. Install drain components to the tub following the drain installation instructions. Note that this requires a cutout in the oor. Before replacing
your tub for nal installation, bathtubs require a 6’’ x 12’’ oor opening for the 1-1/2” drain and waste & overow kit. The drain/overow of
the bath extends below the bottom of the bath.
The bath must be supported along its entire bottom. Do not remove foam base & pad from the bottom of the tub. Use 1-1/2’’ to 2’’ of mortar
as bedding material (do not use sand or foam). After the mortar has been poured, and before it sets, position tub within recess until the rim is
leveled against the leveling stringers (see below).
FIGURE 1
STRINGER INSTALLATION
TYPICAL DROP-IN TYPE INSTALLATION
REFERENCE FOR DROP-IN INSTALLATION
FIGURE 2
TYPICAL ALCOVE INSTALLATION
18"
(457.2mm)
24"
(609.6mm)
24"
(609.6mm)
LEVELING
STRINGERS
ACCESS PANEL MUST BE LOCAT ED
ON THE SAME SIDE AS THE MOTOR.
ALLOW OPEN FRAMING ON
PUMP MOTOR END FOR SERVICE.
ACCESS PANELS NOT REQUIRED
FOR NON-SYSTEM TUBS.
NOTE:
FRONT EDGE OF BATH
MUST BE SUPPORTED
BY STUD WALL.
HEIGHT
TO LIP
TILE
WALLBOARD
G
CUTOUT
18"
(457.2MM)
AS DESIRED
MOUNTING
SURFACE
WATERPROOF
SEALANT
BATH
AS DESIRED
F
CUTOUT
C
SILICONE
1" X 4" JOIST
STUD
AIR GAP 1/4" OR MORE
UNLESS AS ACCESS OPENING OF AT LEST 18" X 24"
IS PROVIDED, WARRANTY SERVICE WILL NOT BE PERFORMED.
ACCESS PANEL MUST BE LOCAT ED
ON THE SAME SIDE AS THE MOTOR.
ALLOW OPEN FRAMING ON
PUMP MOTOR END FOR SERVICE.
ACCESS PANELS NOT REQUIRED
FOR NON-SYSTEM TUBS.
UNLESS AS ACCESS OPENING OF AT LEST 18" X 24"
IS PROVIDED, WARRANTY SERVICE WILL NOT BE PERFORMED.
E
C
D
W
www.mirabelleproducts.com
8
Allow the mortar material to completely harden before applying weight to the rim or bottom of the bath. Any nish material such as tile or
wall board must be self supporting if it contacts the deck of the bath.
Verify that the product is lever by checking the tub deck surface in all directions.
For system tubs ensure blower and or pump cords are properly plugged into the dedicated 120V/20A GFCI outlet to supply electrical power
to the system (Please reference pg. 6) for electrical requirement information. To test run the bath, ll the tub with water at least 3” above the
highest jet and operate the bath for 5 minutes. Check all bath and piping connections for leaks.
POST INSTALLATION CLEAN-UP
Remove all construction debris from bath. Do not use wire brushes or any other metal implement on bath surface.
Post installation clean-up generally can be completed using warm water and liquid dishwashing detergent.
Stubborn dirt or stains may be removed using granular Spic and Span® mixed with water. Painters Naphtha can be used to remove excess
adhesives and/or wet oil-base paint.
Reference for correct tile ange installation
Use drawing below as a reference guide for rough-in measurements
DRAIN CLEARANCE
11”
12”
PUMP ACCESS
STUD
SUGGESTED WHIRLPOOL/BATH
INSTALLATION METHOD
WATERPROOF DRYWALL
OR CEMENT BOARD
TILE
ROOFING NAIL
SEALANT
TUB
1 X 4 (25mm X 76mm)
WOOD STINGER FULL LENGTH
FIGURE 1
STRINGER INSTALLATION
TYPICAL DROP-IN TYPE INSTALLATION
REFERENCE FOR DROP-IN INSTALLATION
FIGURE 2
TYPICAL ALCOVE INSTALLATION
18"
(457.2mm)
24"
(609.6mm)
24"
(609.6mm)
LEVELING
STRINGERS
ACCESS PANEL MUST BE LOCATED
ON THE SAME SIDE AS THE MOTOR.
ALLOW OPEN FRAMING ON
PUMP MOTOR END FOR SERVICE.
ACCESS PANELS NOT REQUIRED
FOR NON-SYSTEM TUBS.
NOTE:
FRONT EDGE OF BATH
MUST BE SUPPORTED
BY STUD WALL.
HEIGHT
TO LIP
TILE
WALLBOARD
G
CUTOUT
18"
(457.2MM)
AS DESIRED
MOUNTING
SURFACE
WATERPROOF
SEALANT
BATH
AS DESIRED
F
CUTOUT
C
SILICONE
1" X 4" JOIST
STUD
AIR GAP 1/4" OR MORE
UNLESS AS ACCESS OPENING OF AT LEST 18" X 24"
IS PROVIDED, WARRANTY SERVICE WILL NOT BE PERFORMED.
ACCESS PANEL MUST BE LOCATED
ON THE SAME SIDE AS THE MOTOR.
ALLOW OPEN FRAMING ON
PUMP MOTOR END FOR SERVICE.
ACCESS PANELS NOT REQUIRED
FOR NON-SYSTEM TUBS.
UNLESS AS ACCESS OPENING OF AT LEST 18" X 24"
IS PROVIDED, WARRANTY SERVICE WILL NOT BE PERFORMED.
E
C
D
W
Framing and Installation
www.mirabelleproducts.com
9
Series Soaker Air Whirlpool Total Massage L W D H A B
Bradenton MIRBDS6030 (L/R) NA NA NA 59.75" 30" 18.88" 17.88" 11" 12"
Bradenton MIRBDS6032 MIRBDA6032 MIRBDW6032 MIRBDT6032 60" 32" 20" 18.5" 11" 16"
Bradenton MIRBDS6032 (L/R) MIRBDA6032 (L/R) MIRBDW6032 (L/R) MIRBDT6032 L/R) 59.75” 32" 21" 20" 11" 16"
Boca Raton MIRBRS6640V MIRBRA6640V MIRBRW6640V MIRBRS6640V 66" 40" 22" 20.5" 35.75" 10"
Boca Raton MIRBRS7242V MIRBRA7242V MIRBRW7242V MIRBRS7242V 71.5" 42" 22" 20.5" 35.75" 10"
Sitka MIRSKS6030 (L/R) MIRSKA6030 (L/R) MIRSKW6030 (L/R) NA 60" 30" 19.5" 19.25" 8.75" 15"
Sitka MIRSKS6032 (L/R) MIRSKA6032 (L/R) MIRSKW6032 (L/R) NA 60" 32" 19.5" 19.25" 8.75" 16"
Sitka MIRSKS6032 MIRSKA6032 MIRSKW6032 NA 60" 32" 19.5" 18.5" 8.75" 16"
Sitka MIRSKS6036 MIRSKA6036 MIRSKW6036 MIRSKT6036 60" 36" 23" 22" 8.75" 18
Sitka MIRSKS6636 MIRSKA6636 MIRSKW6636 MIRSKT6636 66" 36" 23" 22" 8.75" 18""
Sitka MIRSKS7236 MIRSKA7236 MIRSKW7236 MIRSKT7236 72" 36" 23" 22" 8.75" 18"
Galatia MIRGAS6042 MIRGAA6042 MIRGAW6042 MIRGAT6042 60" 42" 21" 19.5" 10.25" 21"
Galatia MIRGAS7242 MIRGAA7242 MIRGAW7242 MIRGAT7242 72" 42" 21" 19.5" 10.25" 21"
Key West MIRKWS6036 MIRKWA6036 MIRKWW6036 MIRKWT6036 60" 36" 22" 20.5" 9.5" 18"
Key West MIRKWS7236 MIRKWS7236 MIRKWW7236 MIRKWT7236 72" 36" 22" 20.5" 8.25" 18"
Provincetown MIRPRS6032 (L/R) MIRPRA6032 (L/R) MIRPRW6032 (L/R) MIRPRT6032 (L/R) 60" 32" 21" 20" 9" 16"
Provincetown MIRPRS6032 MIRPRA6032 MIRPRW6032 MIRPRT6032 59.75” 32" 20" 18.5" 9" 16"
St. Augustine MIRSAS6042 MIRSAA6042 MIRSAW6042 MIRSAT6042 60" 42" 22" 20.5" 8.75" 30"
St. Augustine MIRSAS7242 MIRSAA7242 MIRSAW7242 MIRSAT7242 70" 42" 22" 20.5" 8.5" 36"
Rough-in Dimensions
www.mirabelleproducts.com
10
Deck-to-oor dimensions are measured through the drain hole to give a more consistent measurement. The dimensions are achieved by
laying a straight edge across the deck; the distance was then measured from the oor at the drain opening to the bottom of the straight
edge. (See illustration below). The lip height is then subtracted to give a more consistent oor to lip height. There may be height dimension
variations of plus minus ¼” from the stated dimension in the table, which is a standard production tolerance. Leave adequate clearance with
framing for side mounted controls.
Use drawing below as a guide for rough-in measurements
Height
to Top
Height
to Deck
Tape Measure
Straightedge or Wood Board
Floor
Measure from
Straightedge to Floor
Through Drain
MEASURE FROM THE
FLOOR TO THE STRAIGHT
EDGE THROUGH THE
DRAIN HOLE TO OBTAIN
A CONSISTENT HEIGHT
TO DECK DIMENSION.
D
B
L
W
A
H
L
L
L
L
L
B
B
B
A
A
A
A
W
W
W
C
W
W
B
D
B
L
W
A
H
L
L
L
L
L
B
B
B
A
A
A
A
W
W
W
C
W
W
B
D
B
L
W
A
H
L
L
L
L
L
B
B
B
A
A
A
A
W
W
W
C
W
W
B
D
B
L
W
A
H
L
L
L
L
L
B
B
B
A
A
A
A
W
W
W
C
W
W
B
www.mirabelleproducts.com
11
Care and Cleaning
The use of bath oils and bath salts is not recommended due to the difculty in cleaning the systems and doing so will void the consumer's
warranty.
Air and Total Massage Baths are equipped with an Automatic Purge Cycle for the air blower only. The air blower has a pre-programmed
purge cycle built in to expel the remaining water in the air channels. It activates within 20 minutes after the Air Bath is turned off and then
blows for about 2 to 3 minutes.
After the cycle is completed it will shut off automatically. There is nothing to be alarmed about if you hear a blowing noise coming from
the tub after the tub has been turned off. The noise you hear is the cleaning cycle in operation. It is recommended to activate the air bath
routinely to purge water from the air channel when tub is used as a soaker or shower only. Purge cycle is only activated when blower has
been used.
Pump and pipe circulation system should be ushed before rst use and on a monthly basis when product is under normal use.
Below are the recommended procedures for cleaning:
DO NOT use powdered cleaners unless cleaner is fully dissolved in water.
DO NOT RUN WHIRLPOOL DRY. Fill the tub with hot water 2-3 inches above the jets and add 2-3 teaspoons of low foaming detergent
such as dish washing machine detergent.
DO NOT use full strength bleach of ammonia cleaning solutions. Chemically active cleaning solution can damage the bath surface.
• Switch on whirlpool and run for 10 minutes.
• Drain tub completely.
• Fill tub with cold water above jets.
• Switch on whirlpool and run for 5 minutes.
• Drain tub completely.
DO NOT USE ABRASIVE CLEANERS as they will scratch and dull the surface of the acrylic and void the consumer warranty. Plaster can
be removed using a sharpened wooden stick.
DO NOT USE METAL SCRAPERS, WIRE BRUSHES OR OTHER HARSH ABRASIVE TOOLS.
Usually a mild detergent will remove construction debris. More stubborn debris may be removed with denatured alcohol, or Clorox Soft
Scrub® cleaner. Light scratches and dulled areas may be restored to original luster by rubbing with an automotive type cleaning compound
such as DuPont White Polishing Compound®.
Note: To restore dull or scratched units: Apply white automotive polishing with a clean rage. Rub scratches and dull areas vigorously. Wipe off
residue. Follow with a coat of white automotive paste wax.
DO NOT wax areas where you walk or stand. For crack and major surface damage, call customer service at 1-800-221-3379 for repair
recommendations.
Operating Instructions
1. Fill the bath to at least 3 inches above the jets before activating the pump. DO NOT turn on whirlpool unless jets are completely
submersed in water.
2. The air bath blower and/or whirlpool pump is activated by pushing the control panel buttons (Provincetown and Bradenton system tubs
air/whirlpool is turned on by depressing the actuator button) . DO NOT repeatedly depress the switch in rapid order if you do not see
the whirlpool function right away, as it may take a few seconds before you can see it fully operating. Please see air bath control or Total
Massage Control instructions on the following page for operation and features.
3. If any factory installed ttings are removed; do not operate the unit. A safety hazard may occur.
4. Do not use bubble bath when you operate the whirlpool pump. This might cause excessive foaming.
5. Bath oils should not be used when you operate the whirlpool. If used while soaking, please drain and clean the tub thoroughly prior to
activating the whirlpool system.
6. The use of bath salts is not recommended and doing so will VOID THE CONSUMER’S WARRANTY.
7. Both air and whirlpool systems are plumbed in a way that water will drain from the plumbing easily.
8. The air system is designed to purge within 20 minutes after use (see details on previous page).
9. There are no user serviceable parts located under the tub. If a problem develops, call 1-800-221-3379
www.mirabelleproducts.com
12
Jet Operation and Adjustment
The jets can be easily adjusted by pointing the jet-nozzle in the
desired direction. The strength of the water ow and air induction
can be regulated through twisting the jet- nozzle. Twisting the
nozzle counter-clockwise will decrease the water ow of that
particular jet. If the nozzle is twisted clockwise then the water ow
will increase up to its maximum ow. Only a 1/4 turn or 90° turn is
required from the lowest ow position to the fully OPEN position.
The jets can be easily adjusted by pointing the jet-nozzle in the
desired direction. The strength of the water ow and air induction
can be regulated through twisting the jet- nozzle. Twisting the
nozzle clockwise will decrease the water ow of that particular jet
If the nozzle is twisted counter-clockwise then the water ow will
increase up to its maximum ow. Only a 1/4 turn or 90° turn is
required from the lowest ow position to the fully OPEN position.
Mirabelle Boca Raton, Bradenton, Galatia, Key West,
Provincetown and St. Augustine jets
Mirabelle Sitka jets
The whirlpool is controlled by a three button control.
1. The rst button switches the water-pump on or off. The other features will not operate unless the pump is turned on.
2. The second button sets the power level of the pump. Holding the button depressed will cycle the pump power from low to high in a
continuous cycle. When the desired level is reached, remove your nger quickly from the button to maintain that power setting.
3. The third button is a three step wave action button. Once activated, the jets expel water in a slow pulsating ow called wave action.
There are 3 levels for wave strength.
a. Level 1: operates the pump at
a steady ow.
b. Level 2: quick wave action.
c. Level 3: slower wave action.
Whirlpool Control Center Features
Whirlpool
POWER SPEED WAVE
www.mirabelleproducts.com
13
The air bath is controlled by a three button control.
1. The rst button switches the blower on or off. The other features will not operate unless the blower is turned on.
2. The second button sets the power level of the blower. Holding the button depressed will cycle the blower power from low to high in a
continuous cycle. When the desired level is reached, remove your nger quickly from the button to maintain that power setting.
3. The third button is a three step wave action button. Once activated, the air holes expel air in a slow pulsating ow called wave action. There
are 3 levels for wave strength.
a. Level 1: operates the blower at a steady ow.
b. Level 2: quick wave action.
c. Level 3: slower wave action.
Air Bath Control Center Features
Air
POWER SPEED WAVE
Total Massage units are a combination of whirlpool and air massages. The left three buttons on the control panel. Operate the whirlpool
and the right three buttons operate the air system. The whirlpool and air massage systems may be used at the same time if desired. The
whirlpool and air bath operations are explained in section above.
Total Massage Control Center Features
Total Massage
AIR JETSPEED SPEEDWAVE WAVE
In-Line heater operation
If your unit has an in-line heater installed, operation is automatic only during the use of the whirlpool function. The in-line heater will maintain
the water temperature only while the whirlpool is in operation.
Operating Instructions for Provincetown and Bradenton
Whirlpool baths: Equipped with on/off air switch actuator. Each depression of the switch will activate the pump. If off, one depression will turn
the pump on. if on, the next depression will turn it off.
Air baths: Equipped with a three-speed air switch actuator. Each depression of the switch will change the ow of air. The forth depression will
turn off the air pump.
Total massage baths: Equipped with both an on/off air switch actuator for whirlpool function and three-speed air switch actuator for air
function. See above for operation details.
www.mirabelleproducts.com
14
PROBLEM CAUSES SOLUTION
Motor will not start - Circuit breaker may be tripped
- Lose/Bad wire connection
- GFCI is tripped
- Incorrect electrical installation
- Jets are closed
- Make sure it is a 20 Amp circuit breaker with nothing else tied to the circuit
- Check for incorrect or lose wire connections, and pump/heater has been
properly grounded
- Reset if necessary
- Insure each motor/ in-line heater uses its own 20 Amp circuit breaker and GFCI
plug
- Make sure that jets are fully operational and water is owing
Motor overheating and
cycling
on and off
- Lose/Bad wire connection
- Incorrect Amp usage
- Air supply to motor
- Check for incorrect or loose wire connections
- Check for low voltage supply
- Make sure motor gets fresh air supply and vents are not clogged
Pump/motor operates
but jets/ air is not fully
function
- Jets are closed
- Suction/ strainer may be clogged
- Air valves are closed
- Open jets fully
- With pump off, remove the suction cover/ strainer and
remove any debris.
- Open all air control valves
Motor makes humming
noise but won’t start
- Jets are closed
- Pump does not have space
to operate
- Debris in pump
- Incorrect Amp usage
- Make sure jets are fully open
- Make sure the motor shaft turns free
- Check for jammed impeller or an obstruction on the
(volute) casing.
- Check for low voltage and undersized wire
Low water ow - Clogged pipe
- Incorrect electrical installation
- Check for clogged plumbing lines
- Check for low voltage
Water leaks - Leak in the plumbing - Check compression ttings (union connections) making sure
they are properly aligned and secured. Hand tighten only.
Do not use any tools.
- Make sure the o-ring is properly seated and not damaged.
Troubleshooting
FIVE-YEAR LIMITED WARRANTY
All Mirabelle Whirlpools and Bathing Systems are warranted in accordance with the following Limited Warranty: Mirabelle Whirlpools and Bathing Systems
are warranted against defects in material and workmanship for a period of ve (5) years from the date of the rst consumer purchase. This Warranty shall
apply to defective acrylic surfaces which crack, fade or blister, and any defect in whirlpool and bathing system components. The Warranty extends to the rst
consumer purchaser and not to subsequent owners, transferees or users other than the rst purchaser. This warranty does not extend to products previously
utilized as display models. This Warranty shall apply to products installed and used only for personal, family or household purposes and which are installed
and maintained in accordance with Mirabelle Whirlpool and Bathing Systems’ recommended installation and maintenance procedures. This Warranty does
not extend to defects or damage caused, in whole or in part, by any unauthorized or unreasonable use. No liability shall exist for incidental or consequential
damages caused in whole or part by any defects in Mirabelle Whirlpools and Bathing Systems. No warranty, expressed or implied, including any warranty of
merchantability or tness for a particular purpose, shall apply after the warranty period described above.
Some states do not allow the exclusion or limitation of incidental or consequential damages or limitations on how long an implied warranty lasts. The above
limitation may not apply to you.
In the event of a defect in material or workmanship of a Mirabelle Whirlpool or Bathing System during the Warranty period, defective products will be
repaired or replaced as Mirabelle, at its sole and absolute discretion, determines. However, Mirabelle shall not be liable for the expense for removing
defective products or installing replacement products. In certain circumstances, some states do not allow the limitation of liability for removal, transportation
and reinstallation expenses. The above limitation may not apply to you.
Only Mirabelle is authorized to perform its warranty obligation. If you wish to obtain performance of the Mirabelle warranty obligation you should contact
Mirabelle, at (800) 221-3379. Other information about performance of the Mirabelle Whirlpool and Bathing Systems’ warranty obligation may be obtained at
the same address and telephone number. This Warranty gives you specic legal rights and you may also have other rights which vary from state to state.
www.mirabelleproducts.com
15
Cut-Out Templates
INSTALLING AN OVAL TUB WITH A TEMPLATE
The back section of the installation manual contains oval cut out instructions. Use pencil and tape measure to plot the coordinates and draw
the cut out. Take special care to place tub carefully in the platform cutout, because the tub might break and the ensuing warranty limitations
would become void. For additional questions on installing your tub read “installation procedures” above or call customer service at 800-221-
3379.
Cutout for Galatia Tubs
DROP-IN
CUT OUT LINE
UNDERMOUNT
CUT OUT LINE
6042 GALATIA TEMPLATE
58.2
54.753
36.891
40.2
DROP-IN
CUT OUT LINE
UNDERMOUNT
CUT OUT LINE
6042 GALATIA TEMPLATE
58.2
54.753
36.891
40.2
DROP-IN
CUT OUT LINE
UNDERMOUNT
CUT OUT LINE
7242 GALATIA TEMPLATE
70
66.729
36.885
39.999
30
39.5
19.75
69.5
R19.75
R19.75
25
37.5
18.75
63.5
R18.75
R18.75
Mirabelle Cut-Out Template
Use for Boca Raton 7242
Mirabelle Cut-Out Template
Use for Boca Raton 6640
DROP-IN
CUT OUT LINE
UNDERMOUNT
CUT OUT LINE
6042 GALATIA TEMPLATE
58.2
54.753
36.891
40.2
DROP-IN
CUT OUT LINE
UNDERMOUNT
CUT OUT LINE
7242 GALATIA TEMPLATE
70
66.729
36.885
39.999
30
39.5
19.75
69.5
R19.75
R19.75
25
37.5
18.75
63.5
R18.75
R18.75
DROP-IN
CUT OUT LINE
UNDERMOUNT
CUT OUT LINE
6042 GALATIA TEMPLATE
58.2
54.753
36.891
40.2
DROP-IN
CUT OUT LINE
UNDERMOUNT
CUT OUT LINE
7242 GALATIA TEMPLATE
70
66.729
36.885
39.999
30
39.5
19.75
69.5
R19.75
R19.75
25
37.5
18.75
63.5
R18.75
R18.75
www.mirabelleproducts.com
05/16 165789
www.mirabelleproducts.com
6
Exigences et renseignements électriques
TOTAL MASSAGE CIRCUIT WITH OPTIONAL HEATER
PUMP FLOW
CONTROLL VALV E
0.5 AMP
BACK OF 6 BTN CONTROL
PIGGY BLOWER
9.5 AMP
TMS - VARIABLE
CONTROL
TMS-P/TIMER
CONTROL
ON / OFF PUMP
9 AMP
OPTIONAL
120V, 60 HZ
20 AMP GFCI
120V / 20AMP
MALE PLUG
GFCI GFCI
ELECTRICAL
FEED
120V, 60 HZ
20 AMP GFCI
HEATER
AIR SPEED WAVE
SPEEDJETS WAVE
WHIRLPOOL CIRCUIT WITH OPTIONAL HEATER
PUMP FLOW
CONTROLL VALV E
0.5 AMP
TMS-P/TIMER
CONTROL
ON / OFF PUMP
9 AMP
OPTIONAL
HEATER
120V, 60 HZ
20 AMP GFCI
120V / 20AMP
MALE PLUG
GFCI GFCI
ELECTRICAL
FEED
120V, 60 HZ
20 AMP GFCI
BACK OF 3 BUTTON CONTROL
AIR MASSAGE CIRCUIT
PIGGY BLOWER
9.25 AMP
TMS - VARIABLE
CONTROL
120V, 60 HZ
20 AMP GFCI
GFCI GFCI
ELECTRICAL
FEED
120V, 60 HZ
20 AMP GFCI
GFCI GFCI
ELECTRICAL
FEED
BACK OF 3 BUTTON CONTROL
120V, 60 HZ
20 AMP GFCI
GFCI GFCI
ELECTRICAL
FEED
120V, 60 HZ
9.25 AMP
HEATER
PIGGY BLOWER
9.5 AMP
AIR SWITCH
ON / OFF PUMP
9 AMP
AIR SWITCH
CONTROL BOX
CONTROL BOX
PIGGY BLOWER
9.5 AMP
PUMP / MOTOR
120V, 60 HZ
20 AMP GFCI
GFCI GFCI
ELECTRICAL
FEED
AIR SWITCH
AIR SWITCH
BRADENTON & PROVINCETOWN TOTAL MASSAGE
CIRCUIT WITH OPTIONAL HEATER
BRADENTON & PROVINCETOWN
AIR BATH CIRCUIT
BRADENTON & PROVINCETOWN WHIRLPOOL
WITH INSTALLED AIR SWITCH
POWER SPEED WAVE
POWER SPEED WAVE
www.mirabelleproducts.com
8
Laissez le mortier durcir complètement avant d’appliquer toute pression sur les bords ou sur le fond de la baignoire. Tout matériau de nition,
comme des carrelages ou des panneaux muraux, doit être xé indépendamment de la baignoire s’il est en contact avec cette dernière.
Vériez que la baignoire est à l’horizontale en vériant le niveau de la surface de la baignoire dans toutes les directions.
Si vous installez une baignoire avec un système à remous, vériez que les cordons de la soufante et de la pompe sont correctement
branchés sur la prise courant 120 V / 20 A protégée par un disjoncteur DDFT dédiée à l’alimentation électrique du système (Reportez-vous
à la page 6) pour les exigences et renseignements électriques. Pour effectuer un test de la baignoire, remplissez la baignoire avec de l’eau
au moins 8 cm (3 po) au-dessus du plus haut jet et actionnez le bain pendant 5 minutes. Inspectez tous les raccords de la baignoire et de la
tuyauterie pour vérier l’absence de fuites.
NETTOYAGE APRÈS INSTALLATION
Nettoyez tous les débris de construction de la baignoire. N’utilisez pas une brosse métallique ou tout autre objet en métal sur la surface de la
baignoire.
Le nettoyage après installation peut généralement se faire en utilisant de l’eau chaude et du détergent liquide pour lave-vaisselle.
Il est possible de faire partir les taches tenaces en utilisant de la poudre Spic and Span® mélangée avec de l’eau. Il est possible d’utiliser du
naphte de pétrole pour nettoyer les traces d’adhésifs ou les taches de peinture à l’huile.
Reference for correct tile ange installation
Use drawing below as a reference guide for rough-in measurements
DRAIN CLEARANCE
11”
12”
PUMP ACCESS
STUD
SUGGESTED WHIRLPOOL/BATH
INSTALLATION METHOD
WATERPROOF DRYWALL
OR CEMENT BOARD
TILE
ROOFING NAIL
SEALANT
TUB
1 X 4 (25mm X 76mm)
WOOD STINGER FULL LENGTH
FIGURE 1
STRINGER INSTALLATION
TYPICAL DROP-IN TYPE INSTALLATION
REFERENCE FOR DROP-IN INSTALLATION
FIGURE 2
TYPICAL ALCOVE INSTALLATION
LEVELING
STRINGERS
ACCESS PANEL MUST BE LOCATED
ON THE SAME SIDE AS THE MOTOR.
ALLOW OPEN FRAMING ON
PUMP MOTOR END FOR SERVICE.
ACCESS PANELS NOT REQUIRED
FOR NON-SYSTEM TUBS.
NOTE:
FRONT EDGE OF BATH
MUST BE SUPPORTED
BY STUD WALL.
HEIGHT
TO LIP
TILE
WALLBOARD
G
CUTOUT
18”
(457.2MM)
24”
(609.6MM)
18”
(457.2MM)
24”
(609.6MM)
AS DESIRED
MOUNTING
SURFACE
WATERPROOF
SEALANT
BATH
AS DESIRED
F
CUTOUT
C
SILICONE
1” X 4” JOIST
STUD
AIR GAP 1/4” OR MORE
UNLESS AS ACCESS OPENING OF AT LEST 18” X 24”
IS PROVIDED, WARRANTY SERVICE WILL NOT BE PERFORMED.
ACCESS PANEL MUST BE LOCATED
ON THE SAME SIDE AS THE MOTOR.
ALLOW OPEN FRAMING ON
PUMP MOTOR END FOR SERVICE.
ACCESS PANELS NOT REQUIRED
FOR NON-SYSTEM TUBS.
UNLESS AS ACCESS OPENING OF AT LEST 18” X 24”
IS PROVIDED, WARRANTY SERVICE WILL NOT BE PERFORMED.
E
C
D
W
Support et installation
www.mirabelleproducts.com
10
Les dimensions entre la surface et le plancher sont mesurées par l’orice de vidange, an d’obtenir une mesure plus cohérente. Les
dimensions ont été obtenues en plaçant une règle droite en travers de la surface de la baignoire et en mesurant la distance entre le plancher
et le bord inférieur de la règle droite, à travers l’orice de vidange. (Voir l’illustration). La hauteur du rebord est ensuite soustraite an de
fournir une hauteur plus cohérente entre le sol et la hauteur du rebord. Les dimensions de hauteur peuvent présenter des variations pouvant
atteindre +/- 6 mm (¼ po) par rapport aux dimensions indiquées dans le tableau, ce qui représente une tolérance de production standard.
Laissez un dégagement sufsant avec le support pour pouvoir installer les commandes à montage latéral.
Use drawing below as a guide for rough-in measurements
Height
to Top
Height
to Deck
Tape Measure
Straightedge or Wood Board
Floor
Measure from
Straightedge to Floor
Through Drain
MEASURE FROM THE
FLOOR TO THE STRAIGHT
EDGE THROUGH THE
DRAIN HOLE TO OBTAIN
A CONSISTENT HEIGHT
TO DECK DIMENSION.
D
B
L
W
A
H
L
L
L
L
L
B
B
B
A
A
A
A
W
W
W
C
W
W
B
D
B
L
W
A
H
L
L
L
L
L
B
B
B
A
A
A
A
W
W
W
C
W
W
B
D
B
L
W
A
H
L
L
L
L
L
B
B
B
A
A
A
A
W
W
W
C
W
W
B
D
B
L
W
A
H
L
L
L
L
L
B
B
B
A
A
A
A
W
W
W
C
W
W
B
www.mirabelleproducts.com
15
Modèles de découpe
INSTALLATION D’UNE BAIGNOIRE OVALE AVEC UN MODÈLE
La section au dos du manuel d’installation contient des instructions de découpe ovale. Utiliser un crayon et d’un ruban à mesurer pour
marquer les coordonnées et dessiner la forme de découpe. Prenez soin de placer soigneusement la baignoire dans la découpe de la
plateforme, parce que la baignoire pourrait se briser et les limitations de validité de la garantie pourraient s’appliquer. Pour toute question
concernant l’installation de votre baignoire, veuillez consulter la section « Procédures d’installation » ci-dessus ou appeler le service à la
clientèle au 800-221-3379.
Cutout for Galatia Tubs
DROP-IN
CUT OUT LINE
UNDERMOUNT
CUT OUT LINE
6042 GALATIA TEMPLATE
58.2
54.753
36.891
40.2
DROP-IN
CUT OUT LINE
UNDERMOUNT
CUT OUT LINE
6042 GALATIA TEMPLATE
58.2
54.753
36.891
40.2
DROP-IN
CUT OUT LINE
UNDERMOUNT
CUT OUT LINE
7242 GALATIA TEMPLATE
70
66.729
36.885
39.999
30
39.5
19.75
69.5
R19.75
R19.75
25
37.5
18.75
63.5
R18.75
R18.75
Mirabelle Cut-Out Template
Use for Boca Raton 7242
Mirabelle Cut-Out Template
Use for Boca Raton 6640
DROP-IN
CUT OUT LINE
UNDERMOUNT
CUT OUT LINE
6042 GALATIA TEMPLATE
58.2
54.753
36.891
40.2
DROP-IN
CUT OUT LINE
UNDERMOUNT
CUT OUT LINE
7242 GALATIA TEMPLATE
70
66.729
36.885
39.999
30
39.5
19.75
69.5
R19.75
R19.75
25
37.5
18.75
63.5
R18.75
R18.75
DROP-IN
CUT OUT LINE
UNDERMOUNT
CUT OUT LINE
6042 GALATIA TEMPLATE
58.2
54.753
36.891
40.2
DROP-IN
CUT OUT LINE
UNDERMOUNT
CUT OUT LINE
7242 GALATIA TEMPLATE
70
66.729
36.885
39.999
30
39.5
19.75
69.5
R19.75
R19.75
25
37.5
18.75
63.5
R18.75
R18.75
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48

Mirabelle A7242OMIRBS Installation guide

Type
Installation guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI