Connecting the ‘Y’ Cable
3
Verbinden sie das Kabel nur mit dem vorgesehenen RPS Ausgang. Bei
nicht Beachtung wird das RPS und der SuperStack 3 beschädigt.
Connecting the ‘Y’ Cable
The SuperStack 3 Advanced RPS and its modules can be
“hot-connected” to SuperStack 3 units, that is, you do not need to
remove power from the chassis or other units to connect the cables.
Before connecting the cable, check that the power demand of the
product does not exceed the capacity of the Type 3 Power Module
you are connecting. This information is given in the:
■
Type 3 Power Module Installation Guide (DUA1607-5AAA0X).
■
Advanced RPS Chassis User Guide (DUA1607-0AAA0X).
■
Product user guide.
If you are unable to find the information, or are unsure, please
contact your supplier.
To connect the ‘Y’ cable (3C16077) to your SuperStack 3 unit:
1
Ensure the Type 3 Power Module is in the Advanced RPS chassis
before connecting or disconnecting the optional ‘Y’ DC cable.
CAUTION:
An energy hazard may exist on the Type 3 Power Module
DC connector when the Module is in the Advanced RPS chassis.
2
Check that you are about to connect Type 3 Power Modules
(3C16075) with the Type 3 ‘Y’ cable (3C16077).
3
Connect the male connector to the Redundant Power System socket
on the rear of the SuperStack 3 unit.
4
Connect one female connector to each of two Type 3 Power Module
outlets fitted into the rear of the Advanced RPS chassis.
5
Tighten the screws on all DC cable connectors with a suitable tool.