2, 4, 6, 8 & 10
4602-065-A-9-17
ON
ON
REVERSE
SENSITIVITY
REVERSE
LOOP
EXIT
LOOP
FULL OPEN
DOORKING
4602-010
SW1 SW2
OPEN
TIMER
NC
NO
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
1
2
3
4
5
6
7
8
9
10
UL 325 Terminal and LEDs
115 VAC Convenience
Outlets
1 - OPEN Beam
2 - Common
3 - CLOSE Beam
4 - Common
5 - 24 VAC
6 - Common
7 - OPEN Edge
8 - Common
9 - CLOSE Edge
10 - Common
UL 325 Terminal Description
Closed Gate
Wall / Fence
Open Beam
Wall / Fence
Filler Post if necessary
Closed Gate
Wall / Fence
Close Beam
Closed Gate
Wall / Fence
CLOSE Beam Photo Sensor: Obstructed
closing-direction
photo beam will stop the gate during the closing-
direction only. Gate will resume the close cycle when the
obstructed photo beam has been cleared.
Closed Gate
Low Voltage Common: Common terminals for all entrapment protection device inputs: 2, 4, 6, 8, 10.
CLOSE Edge Reversing Edge: Obstructed closing-direction reversing edge will stop, then reverse the gate to the open position, during the
closing-direction only.
• After the gate reverses to the open position, the timer will
automatically close the gate (if it is turned on). If the
closing-direction reverse edge is activated a second time prior to the gate reaching the
close position, the operator will stop and enter a soft shutdown condition.
• When the closing-direction reversing edge gets obstructed and the gate is traveling back to the open
position and the opening-direction revering edge gets obstructed, the gate will stop and enter a soft shutdown condition.
7
9
1
OPEN Beam Photo Sensor: Obstructed
opening-direction photo beam will stop the gate
during the opening-direction only. Gate will
resume the open cycle when the obstructed photo
beam has been cleared.
OPEN Edge Reversing Edge: Obstructed opening-direction reversing edge will stop, then reverse the gate to the close position during the
opening-direction only.
• After the gate reverses to the full close position, any
opening input will cycle the gate again. Note: If the gate is
opening by a time clock and an opening-direction reversing
edge gets obstructed, the gate will return to the closed
position and another input (automatic exit loop, reverse loop. etc.) is needed to cycle the gate open
again.
• When the opening-direction reversing edge gets obstructed and the gate is traveling back to the close position and
the closing-direction reversing edge gets obstructed, the gate will stop and enter a soft shutdown condition.
Opening Edges
Close Edge
Entrapment Area
Entrapment Area
Entrapment Area
Entrapment Area
WARNING
MOVING GA
T
E CAN
CAU
SE
O
perat
e
g
a
t
e onl
y
whe
n
g
a
te
a
r
e
a
i
s
i
n
s
i
g
ht
a
n
d
f
ree
o
f
p
e
o
pl
e
a
n
d o
bs
t
r
u
c
ti
ons.
Do
n
ot
a
ll
ow
c
h
i
l
d
ren
to
p
l
a
y in g
a
t
e
area
o
r
o
perat
e
g
ate
.
D
o
n
ot
sta
n
d
i
n
g
a
t
e
pa
t
h o
r
w
a
l
k
t
h
r
ou
gh
p
a
t
h
w
hil
e
g
ate
is
movi
ng
.
R
ea
d
ow
ne
r
’s
man
ual
and saf
e
ty
i
n
s
t
r
u
c
t
i
on
s
.
SER
IO
U
S I
NJ
URY
O
R
D
E
ATH
C
L
A
SS
C
E
R
T
IF
IED TO
C
A
N
/
C
S
A
C
22.
2
N
O.
24
7
C
ON
F
ORMS
T
O
A
N
S
I
/
U
L-
3
2
5
VE
HICULAR
GA
TE
O
P
ER
A
TO
R
HP
5
3
382
MO
DE
L
S
E
R
I
A
L
V
O
L
T
S
P
H
A
SE
A
MP
S
6
0 Hz
MA
X
G
AT
E LOAD
Do
o
r
Ki
n
g
,
I
nc.
,
In
g
l
e
w
oo
d
,
C
A
ON
ON
REVERS
E
S
ENS
I
T
I
VIT
Y
REVERS
E
LOOP
EX
I
T
LO
OP
KE
Y S
W
ITC
H
D
OORK
I
NG
4
602
-0
10
SW1
S
W2
OPEN
T
I
MER
N
C
1
2
3
4
5
N
O
Use this control board on pre-2016 9100 and 9150 gate operators only.
In addition to the inherent reversing sensor system, this control board has a UL 325 terminal for the connection of photo sensors-Type B1
and/or reversing edges-Type B2 entrapment protection required by UL 325 standards. External entrapment protection devices MUST be
installed in BOTH directions of gate travel. Install these devices where the risk of entrapment or a safety hazard exists while the gate is
moving. Specific installations will vary. 115 VAC Convenience outlets can be used to power external devcies when necessary.
UL 325 LEDs:
LED ON: Connected device has been activated.
LED remains off during normal operation.
3