Conversion instructions for the multi-function pushbutton
Printed in Germany
2.2 Replacing the power adaptor
Figure 3: Removing the present power adaptor
1. Loosen the connecting screws (3).
2. Disconnect the connecting cable (2) from the connection.
3. Remove the present power adaptor (1) from the bottom part of the housing (4).
4. Make sure that the metal connection jacks (5) remain inserted in the housing.
Figure 4: Inserting the new power adaptor
5. Insert the new power adaptor in the bottom part of the housing.
Important: All 5 pins on the plug (1) must be plugged in the openings of the socket (2).
6. Place the sewing lamp cable into the housing opening (3) and connect it up.
7. Place the connecting cable into the housing opening (4) and connect it up on the board:
• Input cable (brown) to line in (5)
• Neutral conductor cable (blue) to neutral conductor input (6)
• Ground cable (yellow/green) to one of the ground inputs (7)
2.3 Installing the housing
Figure 5: Creating the opening for sewing lamp cable
1. Push in a predetermined breaking point (1) in the adaptor cover using pliers or knife to create
an opening for the sewing lamp cable.
(1) - Power adaptor
(2) - Connecting cable
(3) - Connecting screws
(4) - Bottom part of housing
(5) - Metal connection jacks
(2) - Socket
(3) - Housing opening for sewing lamp cable
(4) - Housing opening for connecting cable
(5) - Line in: L (IN)
(6) - Neutral conductor input: N (IN)
(7) - Ground inputs: PE
(1) - Predetermined breaking point for sewing lamp cable
Retrofit kit 0281 590114
版本 / Edition:
08/2012
修订索引
Rev. index: 00.0
页码:
Sheet: of 122
零件号 / Part No.:
0791 281702
(1) - Board plug