iKey HP-PM-FSR-NI Technical Drawing

Type
Technical Drawing

iKey HP-PM-FSR-NI efficiently combines 3 mouse buttons and a force-sensing resistor pointing device in a durable stainless steel case. It carries the FM Approvals Non-Incendive Certification, making it suitable for hazardous locations and ensuring safe operation. The device has also passed the rigorous testing of ANSI/ISA 61010-1:2012, demonstrating its ability to withstand harsh industrial environments.

With precise pointing capabilities and responsive mouse buttons, iKey HP-PM-FSR-NI enhances user interaction in hazardous areas. It seamlessly connects to the PS2-IS-BARRIER, providing a stable and reliable connection between the keyboard and the host system.

iKey HP-PM-FSR-NI efficiently combines 3 mouse buttons and a force-sensing resistor pointing device in a durable stainless steel case. It carries the FM Approvals Non-Incendive Certification, making it suitable for hazardous locations and ensuring safe operation. The device has also passed the rigorous testing of ANSI/ISA 61010-1:2012, demonstrating its ability to withstand harsh industrial environments.

With precise pointing capabilities and responsive mouse buttons, iKey HP-PM-FSR-NI enhances user interaction in hazardous areas. It seamlessly connects to the PS2-IS-BARRIER, providing a stable and reliable connection between the keyboard and the host system.

Part Number:
Drawing Title:
Date:
CW
Drawing Number: MKT0440
Revision: 2.0
05.14.19
Voice: (512) 837-0283
Fax: (512) 927-8530
Key
iKey, Ltd.
2621 Ridgepoint Dr. Suite 235
Austin, Texas 78754
Voice: (512) 837-0283
Fax: (512) 927-8530
©2019 iKey,Ltd.
Key
PROPRIETARY AND CONFIDENTIAL
HP-PM-FSR-NI
HP-PM-FSR-NI-MKT
CERTIFICATION AND OPERATING SPECIFICATIONS:
DESCRIPTION: The HP-PM-FSR-NI combines a Force Sensing
Resistor pointing device with 3 mouse buttons in a ruggedized
stainless steel case carrying the FM Approvals Non-Incendive
Certification.
USE: The HP-PM-FSR-NI is designed for use in Hazardous
Locations as detailed below. The keyboard must be used in
combination with the iKey PS2-IS-BARRIER.
MAINTENANCE: There are no serviceable parts on this assembly.
NON-INCENDIVE:
Class I, Division 2, Groups A/B/C/D
TEMPERATURE CLASS:
T4 (-40°C ≤ T4 ≤ +75°C)
ENCLOSURE TYPE:
Type 4X
STANDARDS FOR US APPROVAL:
FM3600:2018, FM3610:2018, FM3611:2018, FM3810:2018, ANSI/UL
60079-0:2013 (Group IIB), ANSI/ISA 12.12.0:2015, ANSI/ISA
61010-1:2012, NEMA250:2014
POWER:
Reference Drawing Number HL0069 for Power Requirements
WEIGHT:
1.25 lbs +/- 0.10 lbs (0.57 kg +/- 0.05 kg)
6.00"
6.00"
0.75"
1.12"
DATE
CHANGES
REV
06.14.18 1.0Original
INTL
ALH
HP-PM-FSR-NI
Sheet: 1 OF 3
No revision to drawing
w/o prior FM approval
07.31.18 1.1
Added isolation barrier to wiring concept
ALH
09.13.18 1.2
Removed isolation barrier, added Nonincendive Field Wiring to concept
ALH
01.08.19 1.3
Added Pepperl & Fuchs Isolation Barrier
ALH
05.14.19 2.0
Added PS2-IS-BARRIER removed Pepperl & Fuchs barrier
CW
BEZEL OUTLINE
4.25"
4.25"
CUT OUT
4.25" x 4.25"
0.000"
0.000"
0.365"
0.625"
3.625"
4.615"
4.250"
0.365"
0.625"
3.625"
4.250"
4.615"
3/16" DIA. THROUGH-HOLE
(8 PLACES)
NOTE:
-PCB COMPONENTS REQUIRE 0.25"
CLEARANCE FROM BACK
Part Number:
Drawing Title:
Date:
Sheet: 2 OF 3
CW
Drawing Number: MKT0440
Revision: 2.0
05.14.19
Voice: (512) 837-0283
Fax: (512) 927-8530
Key
iKey, Ltd.
2621 Ridgpoint Dr. Suite 235
Austin, Texas 78754
Voice: (512) 837-0283
Fax: (512) 927-8530
©2019 iKey,Ltd.
Key
PROPRIETARY AND CONFIDENTIAL
HP-PM-FSR-IS
HP-PM-FSR-IS-MKT
INSTALLATION: The HP-PM-FSR-NI and the PS2-IS-BARRIER should only be installed in Hazardous
Locations as detailed in the Certification and Operating Specifications section. Installation shall be in
accordance with NEC, Article 501, ANSI, NFPA 70, reference Drawing Number HL0069. Ensure all
directions detailed below are followed:
1. Place the HP-PM-FSR-NI in the mounting cutout, see diagram below.
2. Hand tighten locking hexnuts over all (8x) 8-32 x 0.75" studs.
3. Tighten with a torque wrench to 15in/lb in order shown on diagram.
NOTE: Installed gasket (RED) should be compressed against mounting surface to ensure NEMA 4X rating.
Hexnuts
MOUNTING SURFACE
GASKET
PCB
No revision to drawing
w/o prior FM approval
Part Number:
Drawing Title:
Date:
CW
Drawing Number: MKT0440
Revision: 2.0
05.14.19
Voice: (512) 837-0283
Fax: (512) 927-8530
Key
iKey, Ltd.
2621 Ridgepoint Dr. Suite 235
Austin, Texas 78754
Voice: (512) 837-0283
Fax: (512) 927-8530
©2019 iKey,Ltd.
Key
PROPRIETARY AND CONFIDENTIAL
HP-PM-FSR-NI
HP-PM-FSR-NI-MKT
Sheet: 3 OF 3
No revision to drawing
w/o prior FM approval
.615" DIA X .580"
D-SHAPED THRU HOLE
DETAIL A
PS/2 CABLE
LENGTH 6ft
PS/2 CABLE
LENGTH 6ft
PS2-IS-BARRIER
Hazardous (Classified) Location
Non Hazardous (Unclassified) Location
PS/2 CABLE
LENGTH 5ft
PS/2 CABLE
LENGTH 6ft
PS/2 ADAPTERS
LENGTH 8in
BULKHEAD PANEL
DUSTCAP
0.615"
0.580"
0.330"
DETAIL A
ASSEMBLING AND DISMANTLING: The HP-PM-FSR-NI keyboard must be
assembled with the PS2-IS-BARRIER as shown in the connection diagram below
and in accordance with Drawing Number HL0069. There are no serviceable parts in
this assembly.
  • Page 1 1
  • Page 2 2
  • Page 3 3

iKey HP-PM-FSR-NI Technical Drawing

Type
Technical Drawing

iKey HP-PM-FSR-NI efficiently combines 3 mouse buttons and a force-sensing resistor pointing device in a durable stainless steel case. It carries the FM Approvals Non-Incendive Certification, making it suitable for hazardous locations and ensuring safe operation. The device has also passed the rigorous testing of ANSI/ISA 61010-1:2012, demonstrating its ability to withstand harsh industrial environments.

With precise pointing capabilities and responsive mouse buttons, iKey HP-PM-FSR-NI enhances user interaction in hazardous areas. It seamlessly connects to the PS2-IS-BARRIER, providing a stable and reliable connection between the keyboard and the host system.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI