T-36 Pinspot

EuroLite T-36 Pinspot, T-36 Pinspot PAR36 Chrom, T-36 Pinspot PAR36 Chrome User manual

  • Hello! I am an AI chatbot trained to assist you with the EuroLite T-36 Pinspot User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
©
Copyright
Nachdruck verboten!
Reproduction prohibited!
Für weiteren Gebrauch aufbewahren!
Keep this manual for future needs!
BEDIENUNGSANLEITUNG
USER MANUAL
T-36 Pinspot
00061369.DOC, Version 2.1
2/16
MULTI-LANGUAGE-INSTRUCTIONS
Inhaltsverzeichnis
Table of contents
EINFÜHRUNG................................................................................................................................................... 3
Lieferumfang .................................................................................................................................................. 3
SICHERHEITSHINWEISE................................................................................................................................. 3
BESTIMMUNGSGEMÄßE VERWENDUNG..................................................................................................... 5
INSTALLATION ................................................................................................................................................ 6
Lampeninstallation/Lampenwechsel .............................................................................................................. 6
Pinspotmontage ............................................................................................................................................. 6
Anschluss ans Netz........................................................................................................................................ 8
BEDIENUNG ..................................................................................................................................................... 8
REINIGUNG UND WARTUNG.......................................................................................................................... 8
TECHNISCHE DATEN ...................................................................................................................................... 9
INTRODUCTION ............................................................................................................................................. 10
Delivery includes .......................................................................................................................................... 10
SAFETY INSTRUCTIONS............................................................................................................................... 10
OPERATING DETERMINATIONS.................................................................................................................. 12
INSTALLATION .............................................................................................................................................. 13
Installing/Replacing the lamp ....................................................................................................................... 13
Rigging ......................................................................................................................................................... 13
Connection with the mains........................................................................................................................... 15
OPERATION.................................................................................................................................................... 15
CLEANING AND MAINTENANCE ................................................................................................................. 15
TECHNICAL SPECIFICATIONS..................................................................................................................... 16
Diese Bedienungsanleitung gilt für die Artikelnummern / This user manual is valid for the article numbers:
50800365, 50800410
Das neueste Update dieser Bedienungsanleitung finden Sie im Internet unter:
You can find the latest update of this user manual in the Internet under:
www.eurolite.de
00061369.DOC, Version 2.1
10/16
USER MANUAL
T-36 Pinspot
CAUTION!
Keepthisdeviceawayfromrainandmoisture!
Unplugmainsleadbeforeopeningthehousing!
For your own safety, please read this user manual carefully before you initially start-up.
Every person involved with the installation, operation and maintenance of this device has to
- be qualified
- follow the instructions of this manual
- consider this manual to be part of the total product
- keep this manual for the entire service life of the product
- pass this manual on to every further owner or user of the product
- download the latest version of the user manual from the Internet
INTRODUCTION
Thank you for having chosen a EUROLITE T-36 Pinspot. If you follow the instructions given in this manual,
we are sure that you will enjoy this device for a long period of time.
Delivery includes
1 Device with installed illuminant
1 User manual
Unpack your T-36 Pinspot.
SAFETY INSTRUCTIONS
CAUTION!
Becarefulwithyouroperations.Withadangerousvoltageyoucansufferadangerous
electricshockwhentouchingthewires!
This pinspot has left our premises in absolutely perfect condition. In order to maintain this condition and to
ensure a safe operation, it is absolutely necessary for the user to follow the safety instructions and warning
notes written in this user manual.
Important:
Damages caused by the disregard of this user manual are not subject to warranty. The dealer
will not accept liability for any resulting defects or problems.
00061369.DOC, Version 2.1
11/16
If the pinspot has been exposed to drastic temperature fluctuation (e.g. after transportation), do not switch it
o
n immediately. The arising condensation water might damage your pinspot. Leave the pinspot switched off
until it has reached room temperature.
Please make sure that there are no obvious transport damages. Should you notice any damages on the A/C
connection cable or on the casing, do not take the pinspot into operation and immediately consult your local
dealer.
This pinspot falls under protection-class I. The power plug must only be plugged into a protection class I
outlet. The voltage and frequency must exactly be the same as stated on the pinspot. Wrong voltages or
power outlets can lead to the destruction of the pinspot and to mortal electrical shock.
Always plug in the power plug last. The power plug must always be inserted without force. Make sure that
the plug is tightly connected with the outlet.
Never let the power-cord come into contact with other cables! Handle the power-cord and all connections
with the mains with particular caution! Never touch them with wet hands, as this could lead to mortal
electrical shock.
Never modify, bend, strain mechanically, put pressure on, pull or heat up the power cord. Never operate next
to sources of heat or cold. Disregard can lead to power cord damages, fire or mortal electrical shock.
The cable insert or the female part in the pinspot must never be strained. There must always be sufficient
cable to the pinspot. Otherwise, the cable may be damaged which may lead to mortal damage.
Make sure that the power-cord is never crimped or damaged by sharp edges. Check the pinspot and the
power-cord from time to time.
If extension cords are used, make sure that the core diameter is sufficient for the required power
consumption of the pinspot. All warnings concerning the power cords are also valid for possible extension
cords.
Always disconnect from the mains, when the pinspot is not in use or before cleaning it. Only handle the
power-cord by the plug. Never pull out the plug by tugging the power-cord. Otherwise, the cable or plug can
be damaged leading to mortal electrical shock. If the power plug or the power switch is not accessible, the
pinspot must be disconnected via the mains.
If the power plug or the pinspot is dusty, the pinspot must be taken out of operation, disconnected and then
be cleaned with a dry cloth. Dust can reduce the insulation which may lead to mortal electrical shock. More
severe dirt in and at the pinspot should only be removed by a specialist.
There must never enter any liquid into power outlets, extension cords or any holes in the housing of the
pinspot. If you suppose that also a minimal amount of liquid may have entered the pinspot, it must
immediately be disconnected. This is also valid, if the pinspot was exposed to high humidity. Also if the
pinspot is still running, the pinspot must be checked by a specialist if the liquid has reduced any insulation.
Reduced insulation can cause mortal electrical shock.
There must never be any objects entering into the pinspot. This is especially valid for metal parts. If any
metal parts like staples or coarse metal chips enter into the pinspot, the pinspot must be taken out of
operation and disconnected immediately. Malfunction or short-circuits caused by metal parts may cause
mortal injuries.
During the initial start-up some smoke or smell may arise. This is a normal process and does not necessarily
mean that the Pinspot is defective.
Caution: During the operation, the housing becomes very hot.
Do not switch the Pinspot on and off in short intervals as this would reduce the lamp’s life.
00061369.DOC, Version 2.1
12/16
HEALTHHAZARD!
Neverlookdirectlyintothelightsource,assensitivepersonsmaysufferan
epilepticshock(especiallymeantforepileptics)!
Keep away children and amateurs! Never leave this pinspot running unattended.
Provideforsufficientsplintershield
CAUTION!
OPERATING DETERMINATIONS
This spot is a lighting effect for creating decorative effects. This product is only allowed to be operated with
an alternating voltage of 230 V, 50 Hz and was designed for indoor use only.
This spot is designed for professional use, e.g. on stages, in discotheques, theatres etc.
Lighting effects are not designed for permanent operation. Consistent operation breaks will ensure that the
spot will serve you for a long time without defects.
Do not shake the spot. Avoid brute force when installing or operating the spot.
When choosing the installation-spot, please make sure that the spot is not exposed to extreme heat,
moisture or dust. There should not be any cables lying around. You endanger your own and the safety of
others!
This spot must never be operated or stockpiled in sourroundings where splash water, rain, moisture or fog
may harm the spot. Moisture or very high humidity can reduce the insulation and lead to mortal electrical
shocks. When using smoke machines, make sure that the spot is never exposed to the direct smoke jet and
is installed in a distance of 0.5 meters between smoke machine and spot. The room must only be saturated
with an amount of smoke that the visibility will always be more than 10 meters.
The ambient temperature must always be between -5° C and +45° C. Keep away from direct insulation
(particularly in cars) and heaters.
The relative humidity must not exceed 50 % with an ambient temperature of 45° C.
This spot must only be operated in an altitude between -20 and 2000 m over NN.
Never use the spot during thunderstorms. Over voltage could destroy the spot. Always disconnect the spot
during thunderstorms.
When choosing the installation-spot, please make sure that the spot is not exposed to extreme heat,
moisture or dust. There should not be any cables lying around. You endanger your own and the safety of
others!
The symbol
---m
determines the minimum distance from lighted objects. The minimum distance
between light-output and the illuminated surface must be more than 0.5 meters.
This spot is only allowed for an installation via the mounting bracket. In order to safeguard sufficient
ventilation, leave 50 cm of free space around the spot.
The housing must never touch surrounding surfaces or objects.
Make sure that the area below the installation place is blocked when rigging, derigging or servicing the
fixture.
Always fix the device with an appropriate safety bond.
00061369.DOC, Version 2.1
13/16
The maximum ambient temperature T
a
= 45° C must never be exceeded.
Operate the spot only after having become familiarized with its functions. Do not permit operation by persons
not qualified for operating the spot. Most damages are the result of unprofessional operation!
Never use solvents or aggressive detergents in order to clean the device! Rather use a soft and damp cloth.
Please use the original packaging if the device is to be transported. Make sure that you pack the device in
the original state.
Please consider that unauthorized modifications on the spot are forbidden due to safety reasons!
If this spot will be operated in any way different to the one described in this manual, the product may suffer
damages and the guarantee becomes void. Furthermore, any other operation may lead to dangers like short-
circuit, burns, electric shock, lamp explosion, crash etc.
INSTALLATION
Installing/Replacing the lamp
DANGERTOLIFE!
Onlyinstallthelampwiththedeviceswitchedoff!
Disconnectfrommainsbefore!
Thelamphastobereplacedwhenitisdamaged
ordeformedduetotheheat!
CAUTION!
Before replacing the lamp, unplug mains lead and let the lamp cool down (approx. 5 minutes).
Please follow the lamp manufacturer's notes!
Do not install lamps with a higher wattage! Lamps with a higher wattage generate temperatures the device
was not designed for. Damages caused by non-observance are not subject to warranty.
For the installation, you need one 6 V/30 W PAR-36 lamp. During the operation, the lamp reaches
temperatures of up to 130° C.
Procedure:
Step 1: Please remove the fixation ring by pressing it together.
Step 2: If replacing the lamp, remove the old lamp from the pinspot and loosen the wires.
Step 3: Loosen the screws on the new 6 V/30W PAR-36 lamp with an appropriate screwdriver.
Step 4: Connect the wires with the lamp using an appropriate screwdriver.
Step 5: Tighten the screws.
Step 6: Insert the lamp in the housing.
Step 7: Fix the lamp with the fixation ring.
Rigging
DANGER TO LIFE!
Please consider the EN 60598-2-17and the respective national standards during the installation!
The installation must only be carried out by an authorized dealer!
The installation of the Pinspot has to be built and constructed in a way that it can hold 10 times the weight for
1 hour without any harming deformation.
00061369.DOC, Version 2.1
14/16
The installation must always be secured with a secondary safety attachment, e.g. an appropriate catch net.
This secondary safety attachment must be constructed in a way that no part of the installation can fall down
if the main attachment fails.
When rigging, derigging or servicing the fixture staying in the area below the installation place, on bridges,
under high working places and other endangered areas is forbidden.
The operator has to make sure that safety-relating and machine-technical installations are approved by an
expert before taking into operation for the first time and after changes before taking into operation another
time.
The operator has to make sure that safety-relating and machine-technical installations are approved by an
expert after every four year in the course of an acceptance test.
The operator has to make sure that safety-relating and machine-technical installations are approved by a
skilled person once a year.
Procedure:
The Pinspot should be installed outside areas where persons may walk by or be seated.
IMPORTANT! OVERHEAD RIGGING REQUIRES EXTENSIVE EXPERIENCE, including (but not limited to)
calculating working load limits, installation material being used, and periodic safety inspection of all
installation material and the Pinspot. If you lack these qualifications, do not attempt the installation yourself,
but instead use a professional structural rigger. Improper installation can result in bodily injury and.or
damage to property.
The Pinspot has to be installed out of the reach of people.
If the Pinspot shall be lowered from the ceiling or high joists, professional trussing systems have to be used.
The Pinspot must never be fixed swinging freely in the room.
Caution: Pinspots may cause severe injuries when crashing down! If you have doubts concerning the safety
of a possible installation, do NOT install the Pinspot!
Before rigging make sure that the installation area can hold a minimum point load of 10 times the Pinspot's
weight.
DANGEROFFIRE!
Wheninstallingthedevice,makesurethereisnohighly-inflammable
material(decorationarticles,etc.)withinadistanceofmin.0.5m.
Mount the Pinspot with the mounting-bracket to your trussing system using an appropriate clamp.
1. Truss ing
2. Hook
3. Mounting- brack et
4. Fixation scr ew
5. Fixation ring
6. PAR-36 lam p
7. Pinspot housi ng
8. Safet y bon d h ole
9. Safet y bon d
10.Quick link
00061369.DOC, Version 2.1
15/16
or:
Mount the Pinspot with the mounting-bracket to the desired installation spot.
Do only use an appropriate screw and make sure that the screw is properly connected with the ground.
F
or overhead use, always install an appropriate safety bond.
You must only use safety bonds complying with DIN 56927, quick links complying with DIN 56927, shackles
complying with DIN EN 1677-1 and BGV C1 carbines. The safety bonds, quick links, shackles and the
carbines must be sufficiently dimensioned and used correctly in accordance with the latest industrial safety
regulations (e. g. BGV C1, BGI 810-3).
Please note: for overhead rigging in public or industrial areas, a series of safety instructions have to be
followed that this manual can only give in part. The operator must therefore inform himself on the current
safety instructions and consider them.
The manufacturer cannot be made liable for damages caused by incorrect installations or insufficient safety
precautions!
Pull the safety bond through the hole in the mounting-bracket and over the trussing system or a safe fixation
spot. Insert the end in the quick link with screw cap and tighten the safety screw.
The maximum drop distance must never exceed 20 cm.
A safety bond which already hold the strain of a crash or which is defective must not be used again.
Adjust the desired inclination-angle via the mounting-bracket and tighten the fixation screws.
DANGERTOLIFE!
Beforetakingintooperationforthefirsttime,theinstallationhastobeapprovedbyanexpert!
Connection with the mains
Connect the device to the mains with the power plug. The occupation of the connection cables is as follows:
Cable Pin International
Brown Live L
Blue Neutral N
Yellow/Green Earth
Attention! The earth has to be connected!
If the device will be directly connected with the local power supply network, a disconnection switch with a
minimum opening of 3 mm at every pole has to be included in the permanent electrical installation.
The device must only be connected with an electric installation carried out in compliance with the IEC
standards. The electric installation must be equipped with a Residual Current Device (RCD) with a maximum
fault current of 30 mA.
OPERATION
After you connected the effect to the mains, the T-36 Pinspot starts running.
CLEANING AND MAINTENANCE
The operator has to make sure that safety-relating and machine-technical installations are inspected by an
expert after every four years in the course of an acceptance test.
00061369.DOC, Version 2.1
16/16
The operator has to make sure that safety-relating and machine-technical installations are inspected by a
s
killed person once a year.
T
he following points have to be considered during the inspection:
1) All screws used for installing the devices or parts of the device have to be tighly connected and must not
be corroded.
2) There must not be any deformations on housings, fixations and installation spots (ceiling, suspension,
trussing).
3) The electric power supply cables must not show any damages, material fatigue (e.g. porous cables) or
s
ediments. Further instructions depending on the installation spot and usage have to be adhered by a
skilled installer and any safety problems have to be removed.
Disconnectfrommainsbeforestartingmaintenanceoperation!
DANGERTOLIFE!
We recommend a frequent cleaning of the device. Please use a moist, lint-free cloth. Never use alcohol or
solvents!
The interior of the device should be cleaned at least annually using a vacuum-cleaner or an air-jet.
There are no serviceable parts inside the device except for the lamp. Maintenance and service operations
are only to be carried out by authorized dealers.
Please refer to the instructions under "Installing/Replacing the lamp".
Should you need any spare parts, please use genuine parts.
If the power supply cable of this device becomes damaged, it has to be replaced by authorized dealers only
in order to avoid hazards.
Should you have further questions, please contact your dealer.
TECHNICAL SPECIFICATIONS
Power supply: 230 V AC, 50 Hz ~
Power consumption: 40 W
Fitting lamp: 6 V/30 W PAR-36
Maximum ambient temperature T
a
:45° C
Maximum housing temperature T
C
(steady state): 65° C
Min. distance from flammable surfaces: 0.5 m
Min. distance to lighted object: 0.5 m
Dimensions (LxWxH): 160 x 150 x 170 mm
Weight: 1 kg
Accessories: No.
GE 4515 PAR-36 6,4V/30W VNSP 100h 88061000
OMNILUX PAR-36 6.4V/30W G53 VNSP 200h 88061005
GE 4511 PAR-36 6.2V/30W WFL 300h 88061200
GE H4515 PAR-36 6V/30W halo 100h 88062000
Color wheel with motor for Pinspot T-36 50805090
Stand for Pinspot, black 50800440
Safety bond AG-5 3x600mm up to 5kg 58010360
Please note: Every information is subject to change without prior notice. 21.06.2011 ©
/