page 4
Warranty is provided under the terms of the TEAC warranty conditions.
In case of warranty: www.teac.de/support
Applicable DVDs DVD-ROM and DVD-Video (single and dual layer), DVD-Audio
DVD-R (vers. 2.00), DVD-RW (vers. 1.0+1.1, DVD-RAM is not
supported
Applicable CDs CD-ROM Mode-1/650 MB/700 MB, CD-DA/74 min/79 min,
CD-ROM XA Mode-2 (Form-1)/650 MB/700 MB,
CD-ROM XA Mode-2 (Form-2)/738 MB/795 MB,
Photo-CD (Single und Multisession), CD-I, CD-Text, Video CD, CD-R,
CD-Extra (CD PLUS), CD-RW (AM2, High Speed CD-RW)
Writable DVDs* DVD-R 4.7 GB, DVD-RW 4.7 GB
Writable CDs* 12 cm CD-R /CD-RW
* Specific application programs are required for writing.
An actual list of media recommended by TEAC can be found at TEACs web site under
www.teac.de/support. Please select the menu "CD-Medias".
Disk diameter 12 cm, 8 cm
Write methods
__for DVD-R
__for DVD-RW
__for CD-R and CD-RW
Disk at once, Incremental recording, multi-border recording
Restricted overwriting
Disk at once, Track at once, Session at once, Packet write
Disk rotational speed ca. 7,200rpm max. (32 X CAV)
Rotational speed
(read mode)
12X (CAV): DVD-ROM (single layer);
8X (CAV): DVD-ROM (dual layer);
6X (CAV): DVD-R (4X media), DVD-RW (2X media);
2X (CLV): DVD-R (2X media), DVD-RW (1X media);
32X (CAV): CD-ROM, CD-R, CD-RW, CD-DA (DAE), Video CD (not
Mode-2, Form-2);
10X (CAV): CD-Audio Play; 4X (CLV): Video CD Mode-2 (Form-2)
Rotational speed
(write mode)
DVD-R: 1X/2X/4X (CLV); DVD-RW: 1X/2X (CLV);
CD-R: 4X/8X/12X/16X (CLV); CD-RW: 4X/8X (CLV)
Under some circumstances the maximum write speed may not be achieved due to external
factors (e.g. supported DVD-R/CD-R media speed or data transfer rate of the computer).
Interface USB 1.1 / USB 2.0 (High Speed)
Data rate USB 1.1: 1.5MB/sec = 12Mbit/sec; USB 2.0: 60MB/sec = 480Mbit/sec
Data buffer capacity 2MByte
Audio out Line out: 0,7Vrms±0,1Vrms (at load of 10 kOhm typ.)
ear phone (ø3.5mm stereo mini jack):
0,7Vrms±0,2Vrms (at load of 32 Ohm)
Power consumption primary: 240V/110V 50/60Hz 850mA
secondary: 5V/2.5A, 12V/1.5A
Environmental condition
Place of operation Temperature 5 to 45 °C (within 10°C/hour deviation)
Humidity 5 to 85 % (non condensing, within 10%/hour deviation)
Place of storage Temperature -20 to 60 °C (within 10°C/hour deviation)
Humidity 5 to 90 % (non condensing, within 10%/hour deviation)
Safety standards CE
Dimensions 167 (W) × 55 (H) × 273 (D) mm
Weight 1.85 kg (without AC adapter and interface cable)
Changes in specifications and features may be made without notice or obligation.
Specifications