MULTISPAN MPC-5264 Owner's manual

Type
Owner's manual
OPERATING MANUAL
CLUTCH & BREAK CONTROL
Key Function
999999
99.99
9.99
99.99
9.9
9.9
99
99
2 Amp.
Break Time
Limit
CMS Range
TIME
ON
Time
BATCH Set
Count
Keys are used to increment or decrement the maximum
Break Time limit.
Keys are used to set the active Range of Colour Mark Sensor.
Keys are used to set the ON Time of Batch
cutter Relay.
Keys are used to set the BATCH Count.
To set the delay Time, press reset key & then using on time delay
time can be set.
Technical Specifacation
1). Model : MPC 5264.
2). Display : LCD 16*2
3). Input : Start Proxy NPN
: Batch Cutter Proxy NPN
: Colour Mark Sensor(CMS-01)
4). LED Indication : Clutch
: Break
: Start
: Relay
: Sensor
5).Output : 2 O/P 230V AC TRIACK
: O/P-1 For Batch Cutter Relay
: O/P-2 For Airfilling Relay
Clutch & Break O/P
6).Power Supply : 230V AC + 10%, 50HZ
Page - 1 www.multispanindia.com
CUT
CUT
BREAK
MPC-5264
Working
Running Clutch Time
Break Time Limit
Active Mark Sensor Range
Pouch Total Count
Batch Set Count
DL TM
ON TM
Running Batch Count
1). and keys are used to increment or decrement the parameters.
when the clutch will on the running clutch time will be start.
It is Used to set the length of the pouch when running clutch time achieves
Break time Limit, Clutch will be OFF & Break will be ON.
At each Start Pulse, the Pouch Total count will be incremented. At any instant
of time the Pouch Total Count shows the total no. of Pouch counted after last
reset.
At each Pulse of batch Proxy, the run count will be incremented and delay time
for air filling 230V AC O/P 2 will start. After achieving the Batch set count, Run
Count will be zero.
When run count achieves the Batch Set Count, the Delay time for Batch cutter
230V AC O/P 1 wiil be ON.
The Delay Time is used to set the delay before it turns on. The Range for delay time
is 0 To 9.9 SEC.
The On time is used to set the on time of any relay. The Range for delay time
is 0 To 9.9 SEC.
This time is used to set the time for which the colour mark sensor is to
be considered.
If Break time Limit is set to 50.00 and Active Mark Sensor Range is set to 2.00
Then the CMS would be Active for only last 2.00 of Break time Limit.
During This period if mark is detected then the Clutch will be OFF & Break
will be ON.
2). Initially Break will be ON.
Page - 2 www.multispanindia.com
MPC-5264
PARAMETERS ON LCD DISPLAY :
POUCH
TOTAL
COUNT
SENSOR
RANGE
TIME
DELAY
TIME
RUNNING
BATCH
COUNT
RUNNING
TIME
BREAK
TIME
LIMIT
ON
TIME
SET
BATCH
COUNT
999999
99.99
99.9
99.99
9.9
9.9
99
99
Page - 3 www.multispanindia.com
MPC-5264
www.multispanindia.com
Connection Diagram:
(G)
(G)
(B)
(B)
I/P
CMS-01
230V AC
O/P-1
L
L
N
N
(24 V, 2 AMP)
230V AC
SUPPLY
L
N
Clutch
(-)
Com
(+)
Break
(-)
(R)
(R)
Product improvement and upgrade is a constant procedure. So for more updated operating information and support,
Please contact our helpline : +91-9978991474/76/82 or Email at ser[email protected] Ver: 04-2018
MPC-5264
Page - 4
230V AC
O/P-2
+12V
+12V
START
PROXY
I/P
I/P
GND
GND
BATCH
PROXY
(
(
MadeinIndia
www.multispanindia.com
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

MULTISPAN MPC-5264 Owner's manual

Type
Owner's manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI