Danfoss Oil Pump RSB/K Installation guide

Type
Installation guide
Technical data
Data in brackets are for RSBK
Viscosity range: 2.5 to 200 cSt. (1.3 to 200)
Pump speed: 1400 - 3600 min
-1
Pressure range: 7 – 21 bar (6 to 21 bar)
Factory setting: Minimum pressure
Oil temperature: Max. 120ºC (90°C)
Max. pressure in suction
and return line: 4 bar
Max. recommended
vacuum on suction side: 0.5 bar
Connections, fig. 1
P=Pressure outlet G
1
/
4
S=Suction inlet G
1
/
2
R=Return port G
1
/
2
P
n
= Pressure gauge G
1
/
8
on front.
All connections have spot faced surfaces for
standard washer.
P
1
= Pressure regulator
RSB/RSBK is delivered for 2-pipe application.
Used as 1-pipe pump the 2-pipe screw placed in
the return port must be removed, and the return
port must be plugged, fig. 2.
Installation
A pre-filter must be installed in accordance with
current rules/practice
Media
The pump specification stipulates mineral-based
fuel oil or media of a corresponding or higher
classification.
First-time start
On 2-pipe installations the pumps have automatic
bleed function. For faster venting of the installation,
open the Pressure gauge connection.
Before starting the pumps the following points
must be observed
Check direction of rotation of the pump.
Secure that there is oil in the pump for lubrication
at start; otherwise fill up the pump with oil.
Make sure that all connections and pipes on the
suction side are airtight.
Open all valves on suction side to create minimum
vacuum at start up.
Open the pressure gauge port on the pressure
side, start the motor and bleed the suction line and
the pump until no more air is coming out of the
pump. Close the pressure gauge-port again.
Insert a pressure gauge to adjust the pump to the
wanted pressure.
Make sure that all valves are in position for normal
operation and that the burner is operating
satisfactory.
Stop the pump, remove the pressure gauge and
restart the pump.
Open all valves on suction side to create minimum
vacuum at start-up.
ENGLISH
Tank installation
Make sure that both suction and return pipe are
below the surface of the oil and that suction inlet is
placed at a level where sludge from the tank bottom
is avoided (at least 10 cm. above bottom) and the
return pipe is placed so far away from the suction
pipe that interference is avoided.
Tank and filter producing companies have
guidelines for installation and also the DIN 4755
give information on installations.
Accessories and spare parts
RSB/RSBK pumps can be used as feed/transport
pumps when using a different pressure regulating
spring.
Code number
Spring for pressure 2 to 6 bar 070H0013
Complete pressure regulator
with shut off
070H0006
Complete shaft seal.
Left hand rotation
070H0009
Complete shaft seal.
Right hand rotation
070H0010
Filter set 070H0011
070R9848
070R9848
INSTRUCTIONS
Oil pump
type RSB/(RSBK)
520F0300 DKBD.PI.12.A1.62 02-02
Produced by Danfoss G1 advertising agency 02.02 FO-Bi.LG
Fig. 2
Fig. 1 LH RH
2-pipe screw
2-strengsskrue
2-Strang Schraube
Vis pour installation bitube
Tornillo de 2 tuberías
Vite per bitubo
2-rörs skruv
2-pijpsschroef
2 putkiruuvi
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

Danfoss Oil Pump RSB/K Installation guide

Type
Installation guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI