3 Bentone
Table of contents
1. General Information ............................................................5
1.1 Delivery inspection ........................................................................5
1.2 Safety ................................................................................................ 5
1.3 What to do if you smell gas .........................................................6
2. Technical data .......................................................................7
2.1 Dimensions Pro 450i M ................................................................7
2.3 Gas categories, approved gases ................................................8
2.2 Capacity range ................................................................................ 8
2.4 Technicalspecication ..................................................................9
2.5 Workingeld ................................................................................... 9
2.6 Components .................................................................................10
2.7 Skeleton diagram .........................................................................12
3. Electric equipment ............................................................. 13
3.1 Safety system ...............................................................................13
3.2 Components .................................................................................13
3.3 Wiring diagram ...........................................................................14
4. Automatic control unit LMV37 .........................................15
4.1 System structure/Function description ...................................15
4.2 General information ....................................................................16
4.3 Technical data Basic unit LMV37.4... ........................................16
4.4 Connection and internal diagram ............................................21
5. Operation ........................................................................... 23
5.1 LMV37 automatic control unit ...................................................23
5.2 List of phase displays ..................................................................25
5.3 Automatic control unit levels ..................................................... 26
5.4 Setting the automatic control unit ...........................................30
5.5 Backup and restore .....................................................................49
5.6 Fault status message, display of errors and info ..................53
5.7 Dispaly message of info .............................................................57
5.8 Resetting the automatic control unit .......................................58
5.9 Manual output ..............................................................................59
6. Parameter list .....................................................................60
7. Error code list .....................................................................70
8. Installation ..........................................................................85
8.1 General instructions ....................................................................85
8.2 Instructions ...................................................................................85
8.3 Inspection and maintenance.....................................................85
8.4 Preparation for assembly .......................................................... 85
8.5 Gas supply .....................................................................................85
8.6 Electric connection ......................................................................85
8.7 Handling and lifting instruction ................................................86
9. Mounting ............................................................................87
9.1 Gas nozzle .....................................................................................88
9.2 De-aerating ...................................................................................89
9.3 Leakage control ............................................................................89
9.4 Calculate prepurge time, Industrial applications .................90
9.5 Calculationofgasow ...............................................................91
10. Settings ...............................................................................92
10.1 Brake plate adjustment ..............................................................92
10.2 Setting the air damper ................................................................92
10.3 Setting the gas damper ..............................................................92
10.4 Startup ............................................................................................93
10.5 Control of combustion ...............................................................93
10.6 Settingtheairpressureswitch .................................................94
10.7 Settingthegaspressureswitch,min. .....................................95
10.8 Settingthegaspressureswitchmax/
overloadprotectionswitch ........................................................96
10.9 SettingthegaspressureswitchVPS .......................................97
11. Gas valve VGD20… SKP15/25 ............................................98
11.1 Technicalspecication ................................................................98
11.2 Overview ........................................................................................99
11.3 Installation position .................................................................. 100
11.4 Adjusting the gas valve ............................................................ 100
11.5 Actuator SKP15 .......................................................................... 100
11.6 Actuator SKP25 .......................................................................... 100
11.7 Gas damper VKG ....................................................................... 102
11.8 SQM Damper motor ................................................................. 103
12. Service ...............................................................................104
12.1 Burner Service Schedule, Gas ................................................ 104
12.2 Component replacement intervals ....................................... 104
12.3 Combustion device ................................................................... 105
12.4 Air damper .................................................................................. 106
12.5 Replacement of damper motor, air ....................................... 107
12.6 Replacement of damper motor, gas ..................................... 108
12.7 Fan ............................................................................................... 109
12.8 Vibrations .................................................................................... 110
12.9 Kontrollavamövervakningochjoniseringsström ........... 111
12.10 Replacement of electrical components................................ 112
13. Handing over of the installation ....................................113
14. Troubleshooting ............................................................... 114
15. Service- and inspection protocol ................................... 116