  • Hello, I'm your chat assistant. I've reviewed the operating manual for the Blue-White Series M4 peristaltic metering pump and I'm ready to help you with any questions you have about its features, installation, maintenance, or its various operating modes. I can provide details on its remote control inputs, safety systems like TFD and FVS, and how to navigate its user interface.
  • What is the purpose of the Tube Failure Detection (TFD) system?
    What is the Flow Verification System (FVS)?
    What kind of remote control inputs does the pump support?
    Can I control the pump remotely using industrial protocols?
Peristaltic Metering Pump
®
Series M4
1.0
Introduction
4
1.1 What’s in the box
5
2.0
Engineering Specifications
6
2.1 Output vs fluid viscosity
7
3.0
Materials of Construction
8
3.1 Wetted Components
8
3.2 Non-Wetted Components
8
4.0
Features
9
4.1 Agency Listings
9
5.0
Installation
10
5.1 Mounting Location
10
5.2 Mounting Dimensions
11
5.3 Input Power Connections
12
5.4 Wiring Terminals and I/O Schematics
13
6.0
Layout
14
6.1 Home Screen Layout / Quick Setting Tab
14
6.2 App Screen Layout
14
6.3 M12 Connectors
15
6.4 IO Connectors
15
6.5 M12 Connectors Description
16
7.0
Startup
18
7.1 Powering On/Off the pump
18
7.2 Welcome Screen
19
8.0
Input Setup
20
8.1 Manual Input
20
8.2 4-20 mA Input
21
8.3 Frequency Input
22
8.4 Pulse Input
23
8.5 Remote Start/Stop (Quick Setting Option)
24
8.6 Flow Verification (FVS) (Quick Setting Opt)
25
8.7 Prime the Pump
26
8.8 Auto Prime the Pump
27
8.9 Time of Day
28
8.10 Revolution Alarm
29
8.11 Passcode
30
8.12 Local Only Mode (via Quick Setting Tab)
31
9.0
Output Setup
32
9.1 4-20 mA Output
32
9.2 Frequency Output
33
9.3 Relay & Contact Output
34
10.0
Industrial Protocols
35
10.1 Control and Status Mapping for Profibus
and EtherNet/IP
35
10.2 Control and Status Mapping for Modbus
TCP
36
10.3 EtherNet/IP
37
10.4 Modbus TCP
38
10.5 Profibus
39
Page 2 ®
FLEXFLO M4 Page 3
®
FLEXFLO M4
READ THE ENTIRE
OPERATING MANUAL PRIOR
TO INSTALLATION AND USE.
+1 (714) 893 - 8529
5300 Business Drive
Huntington Beach, CA 92649
11.0 Tubing
40
11.1 Tube Information
40
11.2 Tube Calibration
41
12.0
Settings
42
12.1 Pump Name
42
12.2 Unit of Volume
43
12.3 Unit of Time
44
12.4 Chemical Name
45
12.5 Language
46
12.6 Pump Rotation Direction
47
12.7 System Time
48
12.8 Resume Operation upon Start-Up
49
12.9 Factory Reset
50
13.0
System
51
13.1 System Information
51
13.2 Firmware Update
52
14.0
Pump Maintenance
53
14.1 Routine Inspection and Maintenance
53
14.2 How to Clean and Lubricate the Pump
53
14.3 Remove Rollers and Tubing Replacement
54
14.4 Pump Head and Roller Exploded Views
55
14.5 TFD (Tube Failure Detection)
56
14.6 Predictive Tube Failure Detection
57
15.0
Replacement Parts
58
15.1 Replacement Parts
58
15.2 Tube Selection Matrix
59
16.0
Accessories
60
17.0
Warranty
63
APPENDIX A: ACRONYMS
64
APPENDIX B: MODEL NUMBER MATRIX
65
1.0
Introduction
1.1 What’s in the box
2.0
Engineering Specifications
2.1 Output vs fluid viscosity
3.0
Materials of Construction
3.1 Wetted Components
3.2 Non-Wetted Components
4.0
Features
4.1 Agency Listings
5.0
Installation
5.1 Mounting Location
5.2 Mounting Dimensions
5.3 Input Power Connections
5.4 Wiring Terminals and I/O Schematics
6.0
Layout
6.1 Home Screen Layout / Quick Setting Tab
6.2 App Screen Layout
6.3 M12 Connectors
6.4 IO Connectors
6.5 M12 Connectors Description
7.0
Startup
7.1 Powering On/Off the pump
7.2 Welcome Screen
8.0
Input Setup
8.1 Manual Input
8.2 4-20 mA Input
8.3 Frequency Input
8.4 Pulse Input
8.5 Remote Start/Stop (Quick Setting Option)
8.6 Flow Verification (FVS) (Quick Setting Opt)
8.7 Prime the Pump
8.8 Auto Prime the Pump
8.9 Time of Day
8.10 Revolution Alarm
8.11 Passcode
8.12 Local Only Mode (via Quick Setting Tab)
9.0
Output Setup
9.1 4-20 mA Output
9.2 Frequency Output
9.3 Relay & Contact Output
10.0
Industrial Protocols
10.1 Control and Status Mapping for Profibus
and EtherNet/IP
10.2 Control and Status Mapping for Modbus
TCP
10.3 EtherNet/IP
10.4 Modbus TCP
10.5 Profibus
Page 2 ®
FLEXFLO M4 Page 3
®
FLEXFLO M4
READ THE ENTIRE
OPERATING MANUAL PRIOR
TO INSTALLATION AND USE.
+1 (714) 893 - 8529
5300 Business Drive
Huntington Beach, CA 92649
11.0 Tubing
40
11.1 Tube Information
40
11.2 Tube Calibration
41
12.0
Settings
42
12.1 Pump Name
42
12.2 Unit of Volume
43
12.3 Unit of Time
44
12.4 Chemical Name
45
12.5 Language
46
12.6 Pump Rotation Direction
47
12.7 System Time
48
12.8 Resume Operation upon Start-Up
49
12.9 Factory Reset
50
13.0
System
51
13.1 System Information
51
13.2 Firmware Update
52
14.0
Pump Maintenance
53
14.1 Routine Inspection and Maintenance
53
14.2 How to Clean and Lubricate the Pump
53
14.3 Remove Rollers and Tubing Replacement
54
14.4 Pump Head and Roller Exploded Views
55
14.5 TFD (Tube Failure Detection)
56
14.6 Predictive Tube Failure Detection
57
15.0
Replacement Parts
58
15.1 Replacement Parts
58
15.2 Tube Selection Matrix
59
16.0
Accessories
60
17.0
Warranty
63
APPENDIX A: ACRONYMS
64
APPENDIX B: MODEL NUMBER MATRIX
65
®
Congratulations on purchasing the M4 FLEXFLO variable speed Peristaltic
Metering Pump.
®
Your FLEXFLO M4 pump is pre-configured for the tubing that shipped with your
metering pump. The tubing assembly has an Identification number printed for
easy re-order.
Please Note: Your new pump has been pressure tested at the factory with
clean water before shipping. You may notice trace amounts of clean water in the
pre-installed tube assembly. This is part of our stringent quality assurance pro-
gram at Blue-White Industries.
For more information please visit us at: www.blue-white.com
For videos and tutorials please visit as at:
https://www.blue-white.com/resources/videos
Page 4 ®
FLEXFLO M4
1.0 Introduction
1.1 What’s In The Box
The following items are included with every M4 peristaltic metering pump:
Page 5
®
FLEXFLO M4 1.0 Introduction
M4 Peristaltic Pump
With 6ft (1.8m) power cord
USB Flash Drive With Instruction Manual
Standard Mounting Brackets
Extended Mounting Brackets
Tube Installation Tool
Spare Tubing
®
Congratulations on purchasing the M4 FLEXFLO variable speed Peristaltic
Metering Pump.
®
Your FLEXFLO M4 pump is pre-configured for the tubing that shipped with your
metering pump. The tubing assembly has an Identification number printed for
easy re-order.
Please Note: Your new pump has been pressure tested at the factory with
clean water before shipping. You may notice trace amounts of clean water in the
pre-installed tube assembly. This is part of our stringent quality assurance pro-
gram at Blue-White Industries.
For more information please visit us at: www.blue-white.com
For videos and tutorials please visit as at:
https://www.blue-white.com/resources/videos
Page 4 ®
FLEXFLO M4
1.0 Introduction
1.1 What’s In The Box
The following items are included with every M4 peristaltic metering pump:
Page 5
®
FLEXFLO M4 1.0 Introduction
M4 Peristaltic Pump
With 6ft (1.8m) power cord
USB Flash Drive With Instruction Manual
Standard Mounting Brackets
Extended Mounting Brackets
Tube Installation Tool
Spare Tubing
2.0 Engineering Specifications
2.1 OUTPUT VERSUS FLUID VISCOSITY
Fluid viscosity and motor RPM both have an effect on fluid output. For your reference the
charts below display the various tubes we offer and their output at different viscosities and
different motor RPM. All testing was conducted with a three foot suction lift.
Tube Material
2.0 Engineering Specifications Page 7
®
FLEXFLO M4
Page 6 ®
FLEXFLO M4
12-1/8”W x 15-1/4”H x 16-1/2”D (30.8W x 38.8H x 41.9D cm)
45.5 lb. (20.64 Kg)
50 lb. (22.68 Kg)
BNH
BNJ
BNL
BNP
MTK
MGK
0
2000
4000
6000
8000
10000
12000
0 25 50 75 100
% Motor Speed
output of water vs. % motor speed
Flow Rate (ml/min)
0
1000
2000
3000
4000
5000
6000
7000
8000
9000
10000
0 25 50 75 100
% Motor Speed
output of 200 cP fluid vs. % motor speed
Flow Rate (ml/min)
0
500
1000
1500
2000
2500
0 25 50 75 100
% Motor Speed
output of 1,700 cP fluid vs. % motor speed
Flow Rate (ml/min)
0
50
100
150
200
250
300
350
0 25 50 75 100
% Motor Speed
output of 12,000 cP fluid vs. motor speed
Flow Rate (ml/min)
115VAC/60Hz, 1ph (3.1 Amp Maximum)
230VAC/60Hz, 1ph (1.6 Amp Maximum)
220VAC/50Hz, 1ph (1.6 Amp Maximum)
240VAC/50Hz, 1ph (1.5 Amp Maximum)
230VAC/50Hz, 1ph (1.5 Amp Maximum)
2.0 Engineering Specifications
2.1 OUTPUT VERSUS FLUID VISCOSITY
Fluid viscosity and motor RPM both have an effect on fluid output. For your reference the
charts below display the various tubes we offer and their output at different viscosities and
different motor RPM. All testing was conducted with a three foot suction lift.
Tube Material
2.0 Engineering Specifications Page 7
®
FLEXFLO M4
Page 6 ®
FLEXFLO M4
12-1/8”W x 15-1/4”H x 16-1/2”D (30.8W x 38.8H x 41.9D cm)
45.5 lb. (20.64 Kg)
50 lb. (22.68 Kg)
BNH
BNJ
BNL
BNP
MTK
MGK
0
2000
4000
6000
8000
10000
12000
0 25 50 75 100
% Motor Speed
output of water vs. % motor speed
Flow Rate (ml/min)
0
1000
2000
3000
4000
5000
6000
7000
8000
9000
10000
0 25 50 75 100
% Motor Speed
output of 200 cP fluid vs. % motor speed
Flow Rate (ml/min)
0
500
1000
1500
2000
2500
0 25 50 75 100
% Motor Speed
output of 1,700 cP fluid vs. % motor speed
Flow Rate (ml/min)
0
50
100
150
200
250
300
350
0 25 50 75 100
% Motor Speed
output of 12,000 cP fluid vs. motor speed
Flow Rate (ml/min)
115VAC/60Hz, 1ph (3.1 Amp Maximum)
230VAC/60Hz, 1ph (1.6 Amp Maximum)
220VAC/50Hz, 1ph (1.6 Amp Maximum)
240VAC/50Hz, 1ph (1.5 Amp Maximum)
230VAC/50Hz, 1ph (1.5 Amp Maximum)
4.1 Agency Listings
Symbol
Description
Warning (Risk of electric shock)
Caution (Refer to the user’s guide)
Ground, Protective Conductor Terminal
ENCLOSURE RATING
NEMA 4X Constructed for either indoor or outdoor use to provide a degree of protection to personnel against incidental
contact with enclosed equipment; to provide a degree of protection against falling dirt, rain, sleet, snow,
windblown dust, splashing water, and hose-directed water; and that will be undamaged by external formation
of ice on enclosure.
IP66 No ingress of dust; complete protection against contact. Water projected in powerful jets against enclosure
from any direction shall have no harmful effects.
!
This pump is ETL listed to conforms to the following: UL Standard 778 as a motor operated water pump.
CSA Standard C22.2 as process control equipment
R
Certified to
NSF/ANSI Standard 61
This pump is certified to NSF/ANSI Standard 61- Drinking Water System Components - Health Effects
Page 9
®
FLEXFLO M4 4.0 Features
3.1 Non-Wetted Components 3.2 Wetted Components
Page 8 ®
FLEXFLO M4
3.0 Materials of Construction
This pump complies to the Machinery Directive 2006/42/EC, BS, EN 60204-1, Low Voltage Directive
2014/35/EU BS EN 61010-1, EMC Directive 2014/30/EU, BS EN 50081-1/BS EN 50082-1.
4.1 Agency Listings
Symbol
Description
Warning (Risk of electric shock)
Caution (Refer to the user’s guide)
Ground, Protective Conductor Terminal
ENCLOSURE RATING
NEMA 4X Constructed for either indoor or outdoor use to provide a degree of protection to personnel against incidental
contact with enclosed equipment; to provide a degree of protection against falling dirt, rain, sleet, snow,
windblown dust, splashing water, and hose-directed water; and that will be undamaged by external formation
of ice on enclosure.
IP66 No ingress of dust; complete protection against contact. Water projected in powerful jets against enclosure
from any direction shall have no harmful effects.
!
This pump is ETL listed to conforms to the following: UL Standard 778 as a motor operated water pump.
CSA Standard C22.2 as process control equipment
R
Certified to
NSF/ANSI Standard 61
This pump is certified to NSF/ANSI Standard 61- Drinking Water System Components - Health Effects
Page 9
®
FLEXFLO M4 4.0 Features
3.1 Non-Wetted Components 3.2 Wetted Components
Page 8 ®
FLEXFLO M4
3.0 Materials of Construction
This pump complies to the Machinery Directive 2006/42/EC, BS, EN 60204-1, Low Voltage Directive
2014/35/EU BS EN 61010-1, EMC Directive 2014/30/EU, BS EN 50081-1/BS EN 50082-1.
nRaise metering pump 4-1/2 inches (11.43 cm) off ground or a surface.
nMade out of tough Stainless Steel.
nProvides a stable mounting surface.
Stainless Steel extended brackets allow the pump to be securely mounted to
most any surface; floor, shelf, or skid. Brackets lift the pump up 4-1/2 inches
(11.43 cm), for easy pump access in hard to reach areas.
Extended Brackets
Front View
Bottom View
Mounting Hole Spacings
(for standard and extended type brackets)
11.5” (29.2 cm)
2.5” (6.35 cm)
Maximum bolt hole size
0.200” diameter (4 places)
Side View
Page 11
®
FLEXFLO M4 5.0 Installation
5.1 Mounting Location
1. Choose an area located near the chemical supply tank, chemical injection point, and electrical supply. Also,
choose an area where the pump can be easily serviced.
2. Finding a secure surface and using the provided mounting hardware, mount the pump close to the injection
point. Keep the inlet (suction) and outlet (discharge) tubing as short as possible. Longer discharge tubing
increases back pressure at pump head.
NOTE: Mounting the pump lower than the chemical container will gravity-feed chemical into it. This “flooded
suction” installation will reduce output error due to increased suction lift. A shut-off valve, pinch-clamp, or
other means to halt gravity-feed to the pump must be installed during servicing.
NOTE: Install a back flow prevention check valve at the discharge side of the pump to prevent the system fluid
from flowing back through pump during tube replacement or during tube rupture.
NOTE: It is recommended to have a pressure relief valve at the discharge side of the of pump to prevent
premature wear and damage to the pump tube, in the event that the discharge line becomes blocked.
NOTE: The does not require back pressure. Keep the discharge pressure as low as possible to maximize pump
the tube life.
All diagrams are strictly for guideline purposes only. Always consult an expert before installing
metering pump on specialized systems. Metering pump should be serviced by qualified persons
only.
Always wear protective clothing, face shield, safety glasses and gloves when working on or near
your metering pump. Additional precautions should be taken depending on solution being
pumped. Refer to MSDS precautions from your solution supplier.
Risk of chemical overdose. Be certain pump does not overdose chemical during backwash and
periods of no flow in circulation system.
Be sure that installation does not constitute a cross connection with drinking water supply.
Check your local plumbing codes.
The pump should be serviced by qualified persons only. If equipment is used in a manner not
specified in this manual, the protection provided by the equipment may be impaired.
The pump should be supplied by an isolating transformer or RCD (operating current less or
equal 30 mA).
!
CAUTION
!
CAUTION
!
CAUTION
!
CAUTION
!
CAUTION
!
CAUTION
Page 10 ®
FLEXFLO M4
5.0 Installation
5.2 Pump Dimensions
nRaise metering pump 4-1/2 inches (11.43 cm) off ground or a surface.
nMade out of tough Stainless Steel.
nProvides a stable mounting surface.
Stainless Steel extended brackets allow the pump to be securely mounted to
most any surface; floor, shelf, or skid. Brackets lift the pump up 4-1/2 inches
(11.43 cm), for easy pump access in hard to reach areas.
Extended Brackets
Front View
Bottom View
Mounting Hole Spacings
(for standard and extended type brackets)
11.5” (29.2 cm)
2.5” (6.35 cm)
Maximum bolt hole size
0.200” diameter (4 places)
Side View
Page 11
®
FLEXFLO M4 5.0 Installation
5.1 Mounting Location
1. Choose an area located near the chemical supply tank, chemical injection point, and electrical supply. Also,
choose an area where the pump can be easily serviced.
2. Finding a secure surface and using the provided mounting hardware, mount the pump close to the injection
point. Keep the inlet (suction) and outlet (discharge) tubing as short as possible. Longer discharge tubing
increases back pressure at pump head.
NOTE: Mounting the pump lower than the chemical container will gravity-feed chemical into it. This “flooded
suction” installation will reduce output error due to increased suction lift. A shut-off valve, pinch-clamp, or
other means to halt gravity-feed to the pump must be installed during servicing.
NOTE: Install a back flow prevention check valve at the discharge side of the pump to prevent the system fluid
from flowing back through pump during tube replacement or during tube rupture.
NOTE: It is recommended to have a pressure relief valve at the discharge side of the of pump to prevent
premature wear and damage to the pump tube, in the event that the discharge line becomes blocked.
NOTE: The does not require back pressure. Keep the discharge pressure as low as possible to maximize pump
the tube life.
All diagrams are strictly for guideline purposes only. Always consult an expert before installing
metering pump on specialized systems. Metering pump should be serviced by qualified persons
only.
Always wear protective clothing, face shield, safety glasses and gloves when working on or near
your metering pump. Additional precautions should be taken depending on solution being
pumped. Refer to MSDS precautions from your solution supplier.
Risk of chemical overdose. Be certain pump does not overdose chemical during backwash and
periods of no flow in circulation system.
Be sure that installation does not constitute a cross connection with drinking water supply.
Check your local plumbing codes.
The pump should be serviced by qualified persons only. If equipment is used in a manner not
specified in this manual, the protection provided by the equipment may be impaired.
The pump should be supplied by an isolating transformer or RCD (operating current less or
equal 30 mA).
!
CAUTION
!
CAUTION
!
CAUTION
!
CAUTION
!
CAUTION
!
CAUTION
Page 10 ®
FLEXFLO M4
5.0 Installation
5.2 Pump Dimensions
Page 13
®
FLEXFLO M4 5.0 Installation
5.3 Input Power Connections
Risk of electric shock – cord connected models are supplied with a grounding
conductor and grounding-type attachment plug. To reduce risk of electric shock, be
certain that it is connected only to a properly grounded, grounding-type receptacle.
WARNING
·Be certain to connect pump to proper supply voltage. Using incorrect voltage will damage
pump and may result in injury. Voltage requirement is printed on pump serial label.
·Input power range is 96VAC to 264VAC 50/60 Hz.
·Voltage Selection is automatically detected and adjusted by power supply. No mechanical
switch necessary.
·Use power cord which is rated for your voltage.
·Power cord models are supplied with a ground wire conductor and a grounding type attach-
ment plug (power cord). To reduce risk of electric shock, be certain that power cord is con-
nected only to a properly grounded, grounding type receptacle.
·Be sure all M12 wiring cable glands are properly installed and sealed.
·Never strap control (input / output) cables and power cables together.
·Power Interruption: This pump has a user programmable auto-restart feature which will can
either restore the pump to the operating state it was in when power was lost or require a user
action to restart.
Note: When in doubt regarding your electrical installation, contact a licensed electrician.
Electrical connections and grounding (earthing) must conform to local wiring codes.
WARNING
Risk of electric shock - Disconnect electricity before removing the wiring
compartment cover.
WARNING
Page 12 ®
FLEXFLO M4
5.0 Installation
5.4 Wiring Terminals and I/O Schematics
INPUT:
4-20 mA
FUNCTION PIN # RATING BLOCK DIAGRAM
(+) POSITIVE
2
3(-) NEGATIVE
(+)
(-)
ACTIVE 4-20mA
TRANSMITTER
SOURCE
(OPTIONAL PUMP #2)
Single or dual pump (series)
input. Loop voltage must not
exceed 24 Volts.
P4
P1
P2
P3
P5
P4
P1
P2
P3
P5
M12 Connector
INPUT #2
INPUT:
FVS SYSTEM
(FLOW VERIFICATION
SENSOR)
FV SENSOR ONLY
(+) POSITIVE
2
3(-) NEGATIVE
P4
P1
P2
P3
P5
INPUT #1
RED (+)
BARE
BLACK (-)
BLUE-WHITE
FVS SENSOR
4SIGNAL
INPUT:
FREQUENCY, AC
SINE WAVE, TTL,
CMOS
(+) POSITIVE
4
5(-) NEGATIVE
(-)
(+)
FREQUENCY TRANSMITTER
SOURCE
P4
P1
P2
P3
P5
INPUT #2
INPUT:
FVS SYSTEM
(FLOW VERIFICATION
SENSOR)
FS or FP MICRO-FLO
FLOWMETER ONLY
INPUT #1
BLUE-WHITE
MICRO-FLO
FLOWMETER
PULSE OUTPUT
P4
P1
P2
P3
P5
SIGNAL
BLACK (-)
(+) POSITIVE
2
3(-) NEGATIVE
4SIGNAL
INPUT:
REMOTE
START/STOP
DRY CONTACT C
PRIMARY
(+) POSITIVE
1
5(-) NEGATIVE
P4
P1
P2
P3
P5
INPUT #1
(+)
(-)
OPEN CIRCUIT
IMPEDANCE MUST
BE GREATER THAN
50K OHM
OUTPUT:
4-20 mA (+) POSITIVE
1
2(-) NEGATIVE
(-)
(+)
P4
P1
P2
P3
P5
OUTPUT #1
4-20mA RECEIVER
600 OHM LOAD MAX.
DIGITAL PULSE
RECEIVER CIRCUIT
1.5K OHM
EXTERNAL SOURCE
6-30V DC
OUTPUT:
FREQUENCY-
OPEN COLLECTOR
(+) POSITIVE
1
2(-) NEGATIVE
(-)
(+)
P4
P1
P2
P3
P5
OUTPUT #2
OUTPUT:
CONTACT
CLOSURE
#1
NORMALLY
OPEN
3
4
P4
P1
P2
P3
P5
OUTPUT #1
NC
C
NO
5COMMON
(GROUND)
SWITCH LOAD
1 AMP MAX @ 125V AC
0.8 AMP MAX @ 30V DC
NORMALLY
CLOSED
OUTPUT:
CONTACT
CLOSURE
#2
NORMALLY
OPEN
3
4
P4
P1
P2
P3
P5
OUTPUT #2
NC
C
NO
5COMMON
(GROUND)
SWITCH LOAD
1 AMP MAX @ 125V AC
0.8 AMP MAX @ 30V DC
NORMALLY
CLOSED
OUTPUT:
CONTACT
CLOSURE
#3
NORMALLY
OPEN
3
4
P4
P1
P2
P3
P5
OUTPUT #3
NC
C
NO
5COMMON
(GROUND)
SWITCH LOAD
1 AMP MAX @ 125V AC
0.8 AMP MAX @ 30V DC
NORMALLY
CLOSED
OUTPUT:
RELAY
6 AMP
NORMALLY
OPEN
3
4
P4
P1
P2
P3
P5
OUTPUT #4
NC
C
NO
5COMMON
(GROUND)
NORMALLY
CLOSED
SWITCH LOAD
6 AMP MAX @ 250V AC
5 AMP MAX @ 30V DC
INPUT:
AUTO-PRIME/
DRY CONTACT C
SECONDARY
(+) POSITIVE
1
5(-) NEGATIVE
P4
P1
P2
P3
P5
INPUT #2
(+)
(-)
OPEN CIRCUIT
IMPEDANCE MUST
BE GREATER THAN
50K OHM
P4
P1
P2
P3
P5
P4
P1
P2
P3
P5
P4
P1
P2
P3
P5
P4
P1
P2
P3
P5
P4
P1
P2
P3
P5
P4
P1
P2
P3
P5
P4
P1
P2
P3
P5
P4
P1
P2
P3
P5
P4
P1
P2
P3
P5
P4
P1
P2
P3
P5
Risk of electric shock - All
wiring must be insulated
and rated 300V minimum.
!
WARNING
KIT-M12 WIRING INSTRUCTIONS
DIAGRAM
PIN #
WIRE
PIN 1
BROWN
PIN 2
WHITE
PIN 3
BLUE
PIN 4
BLACK
PIN 5
GRAY
P4
P1
P2
P3
P5
Shielded cables should be used on all input signal wires.
Excitation voltage = 15V
Page 13
®
FLEXFLO M4 5.0 Installation
5.3 Input Power Connections
Risk of electric shock – cord connected models are supplied with a grounding
conductor and grounding-type attachment plug. To reduce risk of electric shock, be
certain that it is connected only to a properly grounded, grounding-type receptacle.
WARNING
·Be certain to connect pump to proper supply voltage. Using incorrect voltage will damage
pump and may result in injury. Voltage requirement is printed on pump serial label.
·Input power range is 96VAC to 264VAC 50/60 Hz.
·Voltage Selection is automatically detected and adjusted by power supply. No mechanical
switch necessary.
·Use power cord which is rated for your voltage.
·Power cord models are supplied with a ground wire conductor and a grounding type attach-
ment plug (power cord). To reduce risk of electric shock, be certain that power cord is con-
nected only to a properly grounded, grounding type receptacle.
·Be sure all M12 wiring cable glands are properly installed and sealed.
·Never strap control (input / output) cables and power cables together.
·Power Interruption: This pump has a user programmable auto-restart feature which will can
either restore the pump to the operating state it was in when power was lost or require a user
action to restart.
Note: When in doubt regarding your electrical installation, contact a licensed electrician.
Electrical connections and grounding (earthing) must conform to local wiring codes.
WARNING
Risk of electric shock - Disconnect electricity before removing the wiring
compartment cover.
WARNING
Page 12 ®
FLEXFLO M4
5.0 Installation
5.4 Wiring Terminals and I/O Schematics
INPUT:
4-20 mA
FUNCTION PIN # RATING BLOCK DIAGRAM
(+) POSITIVE
2
3(-) NEGATIVE
(+)
(-)
ACTIVE 4-20mA
TRANSMITTER
SOURCE
(OPTIONAL PUMP #2)
Single or dual pump (series)
input. Loop voltage must not
exceed 24 Volts.
P4
P1
P2
P3
P5
P4
P1
P2
P3
P5
M12 Connector
INPUT #2
INPUT:
FVS SYSTEM
(FLOW VERIFICATION
SENSOR)
FV SENSOR ONLY
(+) POSITIVE
2
3(-) NEGATIVE
P4
P1
P2
P3
P5
INPUT #1
RED (+)
BARE
BLACK (-)
BLUE-WHITE
FVS SENSOR
4SIGNAL
INPUT:
FREQUENCY, AC
SINE WAVE, TTL,
CMOS
(+) POSITIVE
4
5(-) NEGATIVE
(-)
(+)
FREQUENCY TRANSMITTER
SOURCE
P4
P1
P2
P3
P5
INPUT #2
INPUT:
FVS SYSTEM
(FLOW VERIFICATION
SENSOR)
FS or FP MICRO-FLO
FLOWMETER ONLY
INPUT #1
BLUE-WHITE
MICRO-FLO
FLOWMETER
PULSE OUTPUT
P4
P1
P2
P3
P5
SIGNAL
BLACK (-)
(+) POSITIVE
2
3(-) NEGATIVE
4SIGNAL
INPUT:
REMOTE
START/STOP
DRY CONTACT C
PRIMARY
(+) POSITIVE
1
5(-) NEGATIVE
P4
P1
P2
P3
P5
INPUT #1
(+)
(-)
OPEN CIRCUIT
IMPEDANCE MUST
BE GREATER THAN
50K OHM
OUTPUT:
4-20 mA (+) POSITIVE
1
2(-) NEGATIVE
(-)
(+)
P4
P1
P2
P3
P5
OUTPUT #1
4-20mA RECEIVER
600 OHM LOAD MAX.
DIGITAL PULSE
RECEIVER CIRCUIT
1.5K OHM
EXTERNAL SOURCE
6-30V DC
OUTPUT:
FREQUENCY-
OPEN COLLECTOR
(+) POSITIVE
1
2(-) NEGATIVE
(-)
(+)
P4
P1
P2
P3
P5
OUTPUT #2
OUTPUT:
CONTACT
CLOSURE
#1
NORMALLY
OPEN
3
4
P4
P1
P2
P3
P5
OUTPUT #1
NC
C
NO
5COMMON
(GROUND)
SWITCH LOAD
1 AMP MAX @ 125V AC
0.8 AMP MAX @ 30V DC
NORMALLY
CLOSED
OUTPUT:
CONTACT
CLOSURE
#2
NORMALLY
OPEN
3
4
P4
P1
P2
P3
P5
OUTPUT #2
NC
C
NO
5COMMON
(GROUND)
SWITCH LOAD
1 AMP MAX @ 125V AC
0.8 AMP MAX @ 30V DC
NORMALLY
CLOSED
OUTPUT:
CONTACT
CLOSURE
#3
NORMALLY
OPEN
3
4
P4
P1
P2
P3
P5
OUTPUT #3
NC
C
NO
5COMMON
(GROUND)
SWITCH LOAD
1 AMP MAX @ 125V AC
0.8 AMP MAX @ 30V DC
NORMALLY
CLOSED
OUTPUT:
RELAY
6 AMP
NORMALLY
OPEN
3
4
P4
P1
P2
P3
P5
OUTPUT #4
NC
C
NO
5COMMON
(GROUND)
NORMALLY
CLOSED
SWITCH LOAD
6 AMP MAX @ 250V AC
5 AMP MAX @ 30V DC
INPUT:
AUTO-PRIME/
DRY CONTACT C
SECONDARY
(+) POSITIVE
1
5(-) NEGATIVE
P4
P1
P2
P3
P5
INPUT #2
(+)
(-)
OPEN CIRCUIT
IMPEDANCE MUST
BE GREATER THAN
50K OHM
P4
P1
P2
P3
P5
P4
P1
P2
P3
P5
P4
P1
P2
P3
P5
P4
P1
P2
P3
P5
P4
P1
P2
P3
P5
P4
P1
P2
P3
P5
P4
P1
P2
P3
P5
P4
P1
P2
P3
P5
P4
P1
P2
P3
P5
P4
P1
P2
P3
P5
Risk of electric shock - All
wiring must be insulated
and rated 300V minimum.
!
WARNING
KIT-M12 WIRING INSTRUCTIONS
DIAGRAM
PIN #
WIRE
PIN 1
BROWN
PIN 2
WHITE
PIN 3
BLUE
PIN 4
BLACK
PIN 5
GRAY
P4
P1
P2
P3
P5
Shielded cables should be used on all input signal wires.
Excitation voltage = 15V
6.3 M12 Connector
Pump (Rear Upper Panel)
M12
Input Connector 2
M12
Input Connector 1
M12
Output Connector 2
M12
Output Connector 3
M12
Output Connector 4
M12
Output Connector 1
6.4 IO Connection
USB-C
Power Supply
ON/OFF
M12
Profibus
Ethernet /
Modbus
Pump (Rear Lower Panel)
Page 15
®
FLEXFLO M4 6.0 Layout
6.1 HOME SCREEN LAYOUT
6.2 APP SCREEN LAYOUT
System Time
Page Indicator (1 of 2)
Tube Info
Blue-White Icon
Home Screen
Page 14 ®
FLEXFLO M4
6.0 Layout
Start/Stop
Tube Info
Quick Setting Tab
Pump Status
Chemical Name
App Drawer
Run Status Settings Tube Calibration
System TimePump Name Run Mode
Run Time /
Revolution Counter
Rotation Direction
Quick Setting Tab - Allow users to quickly
!Activate/Deactivate Local Only Mode
!Activate/Deactivate/Modify Remote Start/Stop function
!Active/Deactivate/Modify FVS function
FVS (Flow Verification Settings)
Remote Start/Stop Settings
Local Only Mode
6.3 M12 Connector
Pump (Rear Upper Panel)
M12
Input Connector 2
M12
Input Connector 1
M12
Output Connector 2
M12
Output Connector 3
M12
Output Connector 4
M12
Output Connector 1
6.4 IO Connection
USB-C
Power Supply
ON/OFF
M12
Profibus
Ethernet /
Modbus
Pump (Rear Lower Panel)
Page 15
®
FLEXFLO M4 6.0 Layout
6.1 HOME SCREEN LAYOUT
6.2 APP SCREEN LAYOUT
System Time
Page Indicator (1 of 2)
Tube Info
Blue-White Icon
Home Screen
Page 14 ®
FLEXFLO M4
6.0 Layout
Start/Stop
Tube Info
Quick Setting Tab
Pump Status
Chemical Name
App Drawer
Run Status Settings Tube Calibration
System TimePump Name Run Mode
Run Time /
Revolution Counter
Rotation Direction
Quick Setting Tab - Allow users to quickly
!Activate/Deactivate Local Only Mode
!Activate/Deactivate/Modify Remote Start/Stop function
!Active/Deactivate/Modify FVS function
FVS (Flow Verification Settings)
Remote Start/Stop Settings
Local Only Mode
Page 17
®
FLEXFLO M4 6.0 Layout
Page 16 ®
FLEXFLO M4
6.0 Layout
6.5 M12 Connector
P4
P1
P2
P5
P1
P4
P5
P3
P2
P3
M12 Input Connector 1
PIN
Function
Specifications
Reference
P1
Remote Start/Stop
No Voltage
P2
FVS (+)
15 VDC @ 60 mA Supply
Power FVS Sensor
P3
FVS (-)
DC GND (0 VDC)
FVS Ground Input
P4
FVS (Signal)
Input Signal
FVS Input Signal
P5
Ground
DC Ground
0 VDC
M12 Input Connector 2
PIN
Function
Specifications
Reference
P1
Auto Prime/
Secondary Input
N.O. Dry Contact Closure
Open= Stop Gnd= Run
P2
4-20mA In (+)
120Ω Impedance Loop Ref. to Ground
Voltage = 15VDC to 24VDC
P3
4-20mA In (-)
DC GND (0 VDC)
P4
Pulse In (+)
0-1000 Hz (AC. Square Wave) Ref. to Ground
P5
Ground
DC GND (0 VDC)
M12 Input/Output Connector M12 Profibus Connector
M12 Profibus Connector
PIN
Function
Specifications
Reference
P1
VP
+5V supply for terminating resisters
P2
RxD/TxD-N
Data line minus (A-line)
P3
DGND
Data ground
P4
RxD/TxD-P
Data line plus (B-line)
P5
Shield
Ground connection
Note:
M12 connectors not included with product.
Input/Output Connectors requires any A-Type M12 connector with 5 position female sockets
Profibus Connectors requires any B-Type M12 connector with 5 position female sockets
If the pump is the last bus device connected to the PROFIBUS cable it must be terminated using terminating resistor
(PROFIBUS standard EN 50170).
M12 Output Connector 1
PIN
Function
Specifications
Reference
P1
4-20mA Out (+)
250Ohm max load
P2
4-20mA Out (-)
DC GND (0 VDC)
P3
N.O.
Contact closure output #1
N.O. Contact 1 Amp @ 125 VAC
.8 Amp Max @ 30VDC
1 Amp @ 125 VAC
P4
N.C.
Contact closure output #1
N.C. Contact
.8 Amp Max @ 30VDC
1 Amp @ 125 VAC
P5
Ground
Contact closure output #1
COM Contact
M12 Output Connector 2
PIN
Function
Specifications
Reference
P1
Pulse Out (+)
0-1000 Hz (AC. Square Wave) Ref. to Ground
P2
Pulse Out (-)
DC GND (0 VDC)
P3
N.O.
Contact closure output #2
N.O. Contact
.8 Amp Max @ 30VDC
1 Amp @ 125 VAC
P4
N.C.
Contact closure output #2
N.C. Contact
.8 Amp Max @ 30VDC
1 Amp @ 125 VAC
P5
Ground
Contact closure output #2
COM Contact
M12 Output Connector 4
PIN
Function
Specifications
Reference
P1
Not Used
P2
Not Used
P3
N.O.
Relay Out, N.O. Contact
6 Amp Max @ 250VAC,
5 Amp MAX @ 30VDC
P4
N.C.
Relay Out, N.C. Contact
6 Amp Max @ 250VAC,
5 Amp MAX @ 30VDC
P5
Ground
Relay Out, COM Contact
M12 Output Connector 3
PIN
Function
Specifications
Reference
P1
Not Used
P2
Not Used
P3
N.O.
Contact closure output #3
N.O. Contact
.8 Amp Max @ 30VDC
1 Amp @ 125 VAC
P4
N.C.
Contact closure output #3
N.C. Contact
.8 Amp Max @ 30VDC
1 Amp @ 125 VAC
P5
Ground
Contact closure output #3
COM Contact
Page 17
®
FLEXFLO M4 6.0 Layout
Page 16 ®
FLEXFLO M4
6.0 Layout
6.5 M12 Connector
P4
P1
P2
P5
P1
P4
P5
P3
P2
P3
M12 Input Connector 1
PIN
Function
Specifications
Reference
P1
Remote Start/Stop
No Voltage
P2
FVS (+)
15 VDC @ 60 mA Supply
Power FVS Sensor
P3
FVS (-)
DC GND (0 VDC)
FVS Ground Input
P4
FVS (Signal)
Input Signal
FVS Input Signal
P5
Ground
DC Ground
0 VDC
M12 Input Connector 2
PIN
Function
Specifications
Reference
P1
Auto Prime/
Secondary Input
N.O. Dry Contact Closure
Open= Stop Gnd= Run
P2
4-20mA In (+)
120Ω Impedance Loop Ref. to Ground
Voltage = 15VDC to 24VDC
P3
4-20mA In (-)
DC GND (0 VDC)
P4
Pulse In (+)
0-1000 Hz (AC. Square Wave) Ref. to Ground
P5
Ground
DC GND (0 VDC)
M12 Input/Output Connector M12 Profibus Connector
M12 Profibus Connector
PIN
Function
Specifications
Reference
P1
VP
+5V supply for terminating resisters
P2
RxD/TxD-N
Data line minus (A-line)
P3
DGND
Data ground
P4
RxD/TxD-P
Data line plus (B-line)
P5
Shield
Ground connection
Note:
M12 connectors not included with product.
Input/Output Connectors requires any A-Type M12 connector with 5 position female sockets
Profibus Connectors requires any B-Type M12 connector with 5 position female sockets
If the pump is the last bus device connected to the PROFIBUS cable it must be terminated using terminating resistor
(PROFIBUS standard EN 50170).
M12 Output Connector 1
PIN
Function
Specifications
Reference
P1
4-20mA Out (+)
250Ohm max load
P2
4-20mA Out (-)
DC GND (0 VDC)
P3
N.O.
Contact closure output #1
N.O. Contact 1 Amp @ 125 VAC
.8 Amp Max @ 30VDC
1 Amp @ 125 VAC
P4
N.C.
Contact closure output #1
N.C. Contact
.8 Amp Max @ 30VDC
1 Amp @ 125 VAC
P5
Ground
Contact closure output #1
COM Contact
M12 Output Connector 2
PIN
Function
Specifications
Reference
P1
Pulse Out (+)
0-1000 Hz (AC. Square Wave) Ref. to Ground
P2
Pulse Out (-)
DC GND (0 VDC)
P3
N.O.
Contact closure output #2
N.O. Contact
.8 Amp Max @ 30VDC
1 Amp @ 125 VAC
P4
N.C.
Contact closure output #2
N.C. Contact
.8 Amp Max @ 30VDC
1 Amp @ 125 VAC
P5
Ground
Contact closure output #2
COM Contact
M12 Output Connector 4
PIN
Function
Specifications
Reference
P1
Not Used
P2
Not Used
P3
N.O.
Relay Out, N.O. Contact
6 Amp Max @ 250VAC,
5 Amp MAX @ 30VDC
P4
N.C.
Relay Out, N.C. Contact
6 Amp Max @ 250VAC,
5 Amp MAX @ 30VDC
P5
Ground
Relay Out, COM Contact
M12 Output Connector 3
PIN
Function
Specifications
Reference
P1
Not Used
P2
Not Used
P3
N.O.
Contact closure output #3
N.O. Contact
.8 Amp Max @ 30VDC
1 Amp @ 125 VAC
P4
N.C.
Contact closure output #3
N.C. Contact
.8 Amp Max @ 30VDC
1 Amp @ 125 VAC
P5
Ground
Contact closure output #3
COM Contact
7.2 Welcome Screen
The first time the pump is powered on, or after a factory reset, the pump will boot up to the
Welcome Screen. Follow the onscreen instructions to configure your M4 pump. Refer to
section 11 of this manual to change any of these options after you have finished the initial
configuration.
Welcome Screen Configuration
1
Local Language
2
Set Time
· Local Date
· Local Time Zone
· Local Time
3
Set Name
· Pump Name
· Chemical Name
4
Set Units
· Unit of Volume
· Unit of Time
5
Set Tube Type
6
Set User Password
Page 19
®
FLEXFLO M4 7.0 Startup
7.1 Powering On The Pump
The M4 is equipped with a rocker switch to power ON/OFF the pump. Ensure that the power
cord is securely plugged into the corresponding power source before powering on the pump.
“I” is pressed to turn on the pump
“O” is pressed to turn off the pump
Page 18 ®
FLEXFLO M4
7.0 Startup
7.2 Welcome Screen
The first time the pump is powered on, or after a factory reset, the pump will boot up to the
Welcome Screen. Follow the onscreen instructions to configure your M4 pump. Refer to
section 11 of this manual to change any of these options after you have finished the initial
configuration.
Welcome Screen Configuration
1
Local Language
2
Set Time
· Local Date
· Local Time Zone
· Local Time
3
Set Name
· Pump Name
· Chemical Name
4
Set Units
· Unit of Volume
· Unit of Time
5
Set Tube Type
6
Set User Password
Page 19
®
FLEXFLO M4 7.0 Startup
7.1 Powering On The Pump
The M4 is equipped with a rocker switch to power ON/OFF the pump. Ensure that the power
cord is securely plugged into the corresponding power source before powering on the pump.
“I” is pressed to turn on the pump
“O” is pressed to turn off the pump
Page 18 ®
FLEXFLO M4
7.0 Startup
To Enable 4-20mA Input:
1
Open the App Drawer
2
Select 4-20mA Input
3
Select Settings to adjust
4-20mA input values
4
Confirm by selecting Save
5
Select Start to enable 4-20mA
Input
8.2 4-20mA Input
This input mode allows the user to set a range of mA input signals to a given motor speed, flow
rate or rpm. Used to remotely control the pump with an incoming 4-20mA signal.
Four points on the slope must be defined:
1) a low mA value
2) an output rate at the low mA value
3) a high mA value
4) an output rate at the high mA value
Default settings: 4mA = 0% motor speed
20mA = 100% motor speed
Option: Stop the pump and select the graph icon to easily adjust sliders to desired settings
Confirm by pressing “Save”
Page 21
®
FLEXFLO M4 8.0 Input Setup
To Enable Manual Speed Adjust:
1
Open the App Drawer
2
Select Manual Speed Adust
3
Select Start to enable Manual
Speed
4
Tap on the feed rate to cycle
through to the option you want
to manually adjust
·Percent motor speed
·RPM
·Flow rate
5
Adjust manual speed by
selecting Increase or Decrease
8.1 Manual Speed Adjust
This input mode allows the user to set a specific speed and the pump will run at that speed
until stopped. There are up and down arrows on the home screen to incrementally adjust the
speed of the motor.
Default: Percent motor speed.
Also Available: Percent motor speed
RPM
Flow rate
Option: Stop pump and select settings to input desired motor speed.
Confirm by pressing “Save”
Page 20 ®
FLEXFLO M4
8.0 Input Setup
/