Renac 4G Stick Module enables remote monitoring of power stations through a mobile app. It supports 4G, LTE, and other network types and connects to an inverter via its COM port. With a MicroSIM card and 4G antenna, it establishes a connection between the inverter and the Renac SEC mobile app. The app allows you to add and manage multiple power stations, view real-time data, and monitor historical records. The module features a compact design and an IP65 protection class, making it suitable for outdoor installations.

Renac 4G Stick Module enables remote monitoring of power stations through a mobile app. It supports 4G, LTE, and other network types and connects to an inverter via its COM port. With a MicroSIM card and 4G antenna, it establishes a connection between the inverter and the Renac SEC mobile app. The app allows you to add and manage multiple power stations, view real-time data, and monitor historical records. The module features a compact design and an IP65 protection class, making it suitable for outdoor installations.

Installation instructions
Pull out the 4G PCBA from the enclosure as below figure 1 , and insert the
SIM card into SIM slot, then plug in the 4G enclosure.Plug the 4G-G1
module into the COM port of the inverter.
2
4G-G1 Module User Manual V1.0
3.Click "+” and scan the QR code (inverter serial number) on the device label
to add a device.
Inverter serial number
Technical data
I
1.1 Connecting Inverter
3
1.2 Download mobile APP
There are two ways to download Renac SEC:
a. Download and install <Renac SEC> mobile app by scanning the QR
code below
b. Download <Renac SEC> from Apple Store / Google Play
1.3 Device Registration
1. Open the APP, fill out requirement information to create a new
account, then click “Submit”.
2. Add the power station page, fill in the corresponding information, click
[Add station] at the bottom to add a new power station (If you do not need
to associate the installer account, the "installer" item can be ignored.
with red is required *)
Indicator Description
4. After adding the power station, back to home page, and the newly added
power station will be shown in the station list.
5. On the home page, click "Statistics" to enter into the equipment list.
6. After the device is successfully added, wait for 5 minutes,while the inverter
status is green, means that the 4G monitoring is successful.
422-00011-00
LED Color LED Status Description
Off
Red
Red
Green
Green
Yellow
Off
On
Flashing
On
Flashing
Flashing
Power supply of module is abnormal or damaged
Antenna or SIM card is initializing
Firmware upgrade
Connection fault between module and server
Module works in normal status
Received data from the inverter
Remote Communication Interface
Working Voltage
Working Power
Local Communication
Data Uploading Interval
Memory
SIM Card
Antenna
Working Temperature
Working Humidity
Altitude
Size (LxWxH)
Protection class
Working frequency
4G
DC 5V-12V
<4W
RS485
Default: 5 mins
64M
MicroSIM(25mm*15mm)
4G Small Antenna
-30 +60
0100% RH
≤4000m
103mm*42mm*30mm
IP65
LTE -FDD/LTE-TDD/WCDMA
TD-SCDMA/CDMA/GSM
4G-G1Model
RENAC Power Technology Co., LTD.,
SIM card
Android & iOS
  • Page 1 1

Renac 4G Stick Module User manual

Type
User manual

Renac 4G Stick Module enables remote monitoring of power stations through a mobile app. It supports 4G, LTE, and other network types and connects to an inverter via its COM port. With a MicroSIM card and 4G antenna, it establishes a connection between the inverter and the Renac SEC mobile app. The app allows you to add and manage multiple power stations, view real-time data, and monitor historical records. The module features a compact design and an IP65 protection class, making it suitable for outdoor installations.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI