LSI MegaRAID LSIiBBU09 Intelligent Battery Backup Unit User guide

Type
User guide

LSI MegaRAID LSIiBBU09 Intelligent Battery Backup Unit protects the integrity of the cached data on a MegaRAID RAID controller for up to 48 hours (depending on the derated retention time selected) in case of a complete AC power failure or a brief power outage.

The LSIiBBU09 unit connects either directly or remotely to your RAID controller, depending on which RAID controller you have. It connects directly to the MegaRAID SAS 9266-4i RAID controller and the MegaRAID SAS 9266-8i RAID controller.

LSI MegaRAID LSIiBBU09 Intelligent Battery Backup Unit protects the integrity of the cached data on a MegaRAID RAID controller for up to 48 hours (depending on the derated retention time selected) in case of a complete AC power failure or a brief power outage.

The LSIiBBU09 unit connects either directly or remotely to your RAID controller, depending on which RAID controller you have. It connects directly to the MegaRAID SAS 9266-4i RAID controller and the MegaRAID SAS 9266-8i RAID controller.

MegaRAID® LSIiBBU09 Intelligent Battery
Backup Unit
Quick Installation Guide
49760-00, Rev. B
August 2012
49760-00B
LSI, the LSI Design logo, and MegaRAID are registered trademarks of LSI Corporation or its subsidiaries. All other brand and product names may be trademarks of their respective companies.
LSI Corporation reserves the right to make changes to the product(s) or information disclosed herein at any time without notice. LSI Corporation does not assume any responsibility or liability arising out of
the application or use of any product or service described herein, except as expressly agreed to in writing by LSI Corporation; nor does the purchase, lease, or use of a product or service from LSI Corporation
convey a license under any patent rights, copyrights, trademark rights, or any other of the intellectual property rights of LSI Corporation or of third parties. LSI products are not intended for use in life-support
appliances, devices, or systems. Use of any LSI product in such applications without written consent of the appropriate LSI officer is prohibited.
Corporate Headquarters Website
Milpitas, CA www.lsi.com
800-372-2447
Document Number: 49760-00, Rev. B
Copyright © 2012 LSI Corporation
All Rights Reserved
MegaRAID LSIiBBU09 Intelligent Battery Backup Unit Quick Installation Guide
June 2012
Revision History
Version and Date Description of Changes
49760-00 Rev. B, August 2012 Updated the list of RAID controllers that support the LSIiBBU09 unit.
49760-00 Rev. A, January 2011 Initial release of the document.
LSI Corporation
- 3 -
MegaRAID LSIiBBU09 Intelligent Battery Backup Unit Quick Installation Guide
August 2012
Product Overview
Direct Connection
MegaRAID® LSIiBBU09 Intelligent Battery Backup Unit
Thank you for purchasing the LSI® MegaRAID® LSIiBBU09 intelligent battery backup unit (iBBU). Before you install and
connect the LSIiBBU09 unit, please take a few minutes to read this quick installation guide. This guide explains how to
connect the LSIiBBU09 unit to your MegaRAID SAS RAID controller.
If you need more information about any topic covered in this guide, refer to the related documents on your MegaRAID
Universal Software Suite CD.
Product Overview
The LSI MegaRAID LSIiBBU09 product is an iBBU based on Lithium ion (LiON) battery cell technology. The LSIiBBU09
unit protects the integrity of the cached data on a MegaRAID RAID controller for up to 48 hours (depending on the
derated retention time selected) in case of a complete AC power failure or a brief power outage. You can connect the
LSIiBBU09 unit either directly or remotely to your RAID controller, depending on which RAID controller you have.
LSI provides a family of MegaRAID iBBUs for use with its high-performance MegaRAID RAID controllers. The LSI
MegaRAID iBBUs provide an inexpensive alternative to using an uninterruptible power supply (UPS) and a second
level of fault tolerance when used with a UPS.
Direct Connection
The LSIiBBU09 unit connects directly to the following MegaRAID SAS RAID controllers:
MegaRAID SAS 9266-4i RAID controller
MegaRAID SAS 9266-8i RAID controller
See Attaching a LSIiBBU09 Unit Directly to a MegaRAID SAS 9266 RAID Controller for instructions on how to attach the
LSIiBBU09 unit directly to these controllers.
Remote Connection
The LSIiBBU09 unit connects remotely to the following MegaRAID SAS RAID controllers:
MegaRAID SAS 9265-8i RAID controller
MegaRAID SAS 9266-4i RAID controller
MegaRAID SAS 9266-8i RAID controller
MegaRAID SAS 9285-8e RAID controller
The LSIiBBU09 unit connects remotely by cable to the MegaRAID SAS 9266-4i RAID controller and the MegaRAID SAS
9266-8i RAID controller.
The LSIiBBU09 unit connects remotely to a TMM02® transportable memory module that is attached to the MegaRAID
SAS 9265-8i RAID controller and the MegaRAID SAS 9285-8e RAID controller. You have two ways to connect the
remote LSIiBBU09 unit by cable to a TMM02 transportable memory module on these two controllers:
Connect the LSIiBBU09 unit by cable to the TMM02 module on the RAID controller and then mount the LSIiBBU09
unit on the system chassis (see Connecting a Remote LSIiBBU09 Unit on the System Chassis to a TMM02 Module
on a RAID Controller on page 11 for the instructions).
LSI Corporation
- 4 -
MegaRAID LSIiBBU09 Intelligent Battery Backup Unit Quick Installation Guide
August 2012
Top View and Bottom View of the LSIiBBU09 Unit
Remote Connection
Connect the LSIiBBU09 unit on a remote mounting board by cable to the TMM02 module on the RAID controller
(see Connecting a LSIiBBU09 Unit on a Remote Mounting Board to a TMM02 Module on a RAID Controller on
page 13 for the instructions).
Top View and Bottom View of the LSIiBBU09 Unit
The following figure shows the top view and the bottom view of the LSIiBBU09 unit. The top view is the side that
you can see after you install the LSIiBBU09 unit on the system chassis or when the unit is installed on a remote
mounting board.
Figure 1 Top View and Bottom View of the LSIiBBU09 Unit
1. Board-to-Board Connector
2. Remote Cable Connector
WARNING The battery used in this device might present a fire or chemical burn hazard if mistreated. Do
not disassemble, heat above 100 °C (212 °F) or incinerate. Dispose of used battery correctly. Keep it away
from children.
NOTE Record your controller serial number in a safe location in case you need to contact LSI.
LSI CORP. © 2010 ALL RIGHTS RESERVED
Pb e1
ASSEMBLED
IN CHINA
RoHS
AsRPCB
E248037
94V0
Li Ion
Model: BAT1S1P-A
BBU P/N: L4-25407-00
BBU S/N: SAYWWSSSSSss
Contains:
Sony US454261A8T Cell
Rechargeable Li-Polymer
Battery Pack
Rating:
3.7V; 1.59 Ah; 5.9Wh
Finished in China
WARNING: The battery used in this
device may present a risk of fire or
chemical burn if mistreated. DO NOT
disassemble, heat above 60C, crush or
puncture, short circuit external contacts,
or dispose of in fire or water.
MH29577
Li-ion
!
L3-25407-00A
Top View
Bottom View
85083-00
1
2
LSI Corporation
- 5 -
MegaRAID LSIiBBU09 Intelligent Battery Backup Unit Quick Installation Guide
August 2012
Attaching a LSIiBBU09 Unit Directly to a MegaRAID SAS 9266 RAID Controller
Removing the RAID Controller from the Computer
Attaching a LSIiBBU09 Unit Directly to a MegaRAID SAS 9266 RAID Controller
This section describes how to connect the MegaRAID LSIiBBU09 unit directly to a MegaRAID SAS 9266-4i RAID
controller or a MegaRAID SAS 9266-8i RAID controller.
Perform the following tasks described in this section to attach the LSIiBBU09 unit directly to the MegaRAID SAS 9266
RAID controller.
1. Remove the RAID controller from the computer. See Removing the RAID Controller from the Computer.
2. Attach the LSIiBBU09 unit directly to the RAID controller. See Attaching the LSIiBBU09 Unit to the RAID Controller.
3. Reinstall the RAID controller on the motherboard. See Reinstalling the RAID Controller on the Motherboard on
page 6.
Removing the RAID Controller from the Computer
Follow these steps to remove the RAID controller from the computer.
1. Turn off the power, and unplug the power cords.
2. Ground yourself, and make sure that the system is grounded.
3. Remove the cover from the computer, according to the instructions in the system users manual, to permit access
to the controller.
4. Unplug all cables from the controller, remove the screw that attaches the bracket to the computer chassis, and
carefully remove the controller from the slot.
5. Place the controller on a flat, clean, static-free surface, and continue with the next procedure.
Attaching the LSIiBBU09 Unit to the RAID Controller
Follow these steps to attach the LSIiBBU09 unit directly to the front of the RAID controller.
1. Ground yourself, and make sure that the system is grounded.
2. Remove the LSIiBBU09 unit from the package.
3. Place the LSIiBBU09 unit front-side-up on a flat, clean, static-free surface.
4. Place the RAID controller front-side-up on a flat, clean, static-free surface.
5. Hold the LSIiBBU09 unit so that the top of the battery is facing upward, and the J1 connector lines up with the
J1A3 BBU connector on the RAID controller, as the following figure shows.
WARNING The battery used in this device might present a fire or chemical burn hazard if mistreated. Do
not disassemble, heat above 100 °C (212 °F) or incinerate. Dispose of used battery correctly. Keep it away
from children.
CAUTION Electrostatic discharge (ESD) can damage the LSIiBBU09 unit and the RAID controller. Make
sure that you install the LSIiBBU09 unit at an ESD-safe workstation that meets the EIA-625 standard. When
you install the LSIiBBU09 unit, follow the ESD-recommended practices in the latest revision of the
IPC-A-610 standard.
WARNING There is danger of an explosion if the battery is incorrectly replaced. Replace the battery only with
the same or equivalent type recommended by the manufacturer. Dispose of used batteries according to the
manufacturers instructions.
LSI Corporation
- 6 -
MegaRAID LSIiBBU09 Intelligent Battery Backup Unit Quick Installation Guide
August 2012
Attaching a LSIiBBU09 Unit Directly to a MegaRAID SAS 9266 RAID Controller
Reinstalling the RAID Controller on the Motherboard
Figure 2 Attaching the LSIiBBU09 Unit to the RAID Controller
6. Carefully press the LSIiBBU09 unit onto the RAID controller so that the two connectors are firmly joined.
7. Secure the LSIiBBU09 unit to the RAID controller with the screws and the standoffs in the three screw holes.
The standoffs are threaded at both ends, and a screw goes into each end. The screw threads from the back of the
controller board into the board-to-board standoffs on the bottom of the LSIiBBU09 unit.
Center the screwdriver carefully to avoid stripping the screw heads. Do not over-tighten the screws.
Reinstalling the RAID Controller on the Motherboard
Follow these steps to reinstall the RAID controller on a motherboard.
1. Make sure that the power to the chassis is still turned off, the power cords are unplugged, and the chassis is
grounded and has no AC power.
2. Install the RAID controller in a PCI Express slot on the motherboard, as the following figure shows.
3. Press down gently, but firmly, to seat the card correctly in the slot.
4. Secure the controller to the computer chassis.
NOTE Some PCI Express slots support only PCI Express graphics cards. If a RAID controller is installed in
one of these slots, the controller will not function. Refer to your computer documentation for information
about the PCI Express slot.
3_00896-00
J1A3
LSIiBBU09
LSI Corporation
- 7 -
MegaRAID LSIiBBU09 Intelligent Battery Backup Unit Quick Installation Guide
August 2012
Connecting a Remote LSIiBBU09 Unit to a MegaRAID SAS 9266 RAID Controller
Reinstalling the RAID Controller on the Motherboard
Figure 3 Reinstalling the RAID Controller
5. Replace the computer cover, and reattach the power cords.
6. Turn on the power to the computer.
Connecting a Remote LSIiBBU09 Unit to a MegaRAID SAS 9266 RAID Controller
The procedures in this section show how to connect a remote LSIiBBU09 unit by cable to your MegaRAID SAS 9266-4i
RAID controller or a MegaRAID SAS 9266-8i RAID controller.
To connect a remote LSIiBBU09 unit to your RAID controller, perform the following tasks.
1. Remove the RAID controller from the computer. See Removing the RAID Controller from the Computer on page 8.
2. Connect the cable between the RAID controller and the remote LSIiBBU09 unit. See Connecting the Cable
Between the RAID Controller and the Remote LSIiBBU09 Unit on page 8.
3. Reinstall the RAID controller in the computer. See Reinstalling the RAID Controller in the Computer on page 9.
Edge of
Motherboard
PCI Express
Bracket
Screw
Press
Here
Press
Here
3_00891a-00
LSI Corporation
- 8 -
MegaRAID LSIiBBU09 Intelligent Battery Backup Unit Quick Installation Guide
August 2012
Connecting a Remote LSIiBBU09 Unit to a MegaRAID SAS 9266 RAID Controller
Removing the RAID Controller from the Computer
Removing the RAID Controller from the Computer
Follow these steps to remove the RAID controller from the computer.
1. Turn off the power, and unplug the power cords.
2. Ground yourself, and make sure that the system is grounded.
3. Remove the cover from the computer, according to the instructions in the system users manual, to permit access
to the controller.
4. Unplug all cables from the controller, remove the screw that attaches the bracket to the computer chassis, and
carefully remove the controller from the slot.
5. Place the controller on a flat, clean, static-free surface, and continue with the next procedure.
Connecting the Cable Between the RAID Controller and the Remote LSIiBBU09 Unit
Follow these steps to connect the cable between the RAID controller and the LSIiBBU09 unit.
1. Place the controller on a flat, clean, static-free surface.
2. Ground yourself, and make sure that the system is grounded.
3. Remove the cable included in the Remote Battery Kit (sold separately).
4. Insert one end of the cable into the 20-pin cable connector on the LSIiBBU09 unit and the other end of the cable
into the 20-pin J3L1 cable connector on the back of the RAID controller, as the following figure shows.
5. Align the black triangles on the connectors to make sure that the connectors are connected correctly.
Figure 4 Connecting the Remote LSIiBBU09 Unit by Cable to the RAID Controller
LS I CORP . © 2010 AL L R IG HTS R E SERVED
Pb e1
AS SE MB LE D
IN CH INA
Ro HS
AsRP CB
E248037
94V 0
L
i
I
on
M
o
d
el: B
AT1S
1P-A
BB
U
P
/N
:
L
4
-2
54
0
7-
0
0
BBU
S
/
N
:S
AYWW
S
S
SSSs
s
Co
n
t
ai
ns:
So
ny U
S
4
54
2
61
A
8T Ce
ll
Recha
r
g
e
ab
l
eL
i-
Po
lyme
r
Batte
r
y
Pa
ck
Rating
:
3.7V
;1
.5
9
Ah
;
5
.
9
Wh
F
i
n
i
sh
ed
in
Ch
in
a
WA
RN
I
NG
:T
h
e
b
a
t
te
r
y
used
i
nthi
s
d
e
v
ic
em
a
yp
resent
a
r
i
sk
o
f
f
ire
o
r
c
h
em
ical
b
u
r
n
i
f
m
istr
e
a
te
d
.D
O
N
O
T
d
i
sa
ssembl
e,
h
ea
t
ab
o
ve
6
0
C
,c
rush
o
r
p
u
n
ct
ure
, s
ho
rt
c
i
rc
ui
te
xt
e
r
n
a
l
c
on
ta
c
ts
,
o
r
d
i
s
p
o
s
eo
fi
nf
ire or
w
a
te
r
.
MH
2
9
57
7
Li-i
on
!
L
3
-
2
5
407
-
0
0A
3_00897-00
LSI Corporation
- 9 -
MegaRAID LSIiBBU09 Intelligent Battery Backup Unit Quick Installation Guide
August 2012
Connecting a Remote LSIiBBU09 Unit to a MegaRAID SAS 9266 RAID Controller
Reinstalling the RAID Controller in the Computer
Reinstalling the RAID Controller in the Computer
Follow these steps to reinstall the RAID controller in the computer.
1. Mount the LSIiBBU09 unit to the chassis of your computer based on the location and the type of
mounting option.
2. Make sure that the power to the chassis is still turned off, the power cords unplugged, and the chassis is grounded
and has no AC power.
3. Insert the RAID controller in a PCI Express slot on the motherboard, as the following figure shows.
4. Press down gently, but firmly, to seat the controller correctly in the slot.
5. Secure the controller to the computer chassis.
NOTE Because server and workstation chassis vary from vendor to vendor, no standard mounting option
exists for the LSIiBBU09 unit that is compatible with the various system configurations. Authorized
resellers and chassis manufacturers can customize the location of the battery backup unit to provide the
most flexibility within various environments. The BBU-BRACKET-05 remote mount board is an option,
because it has holes appropriate for mounting MegaRAID BBU units.
NOTE Some PCI Express slots support only PCI Express graphics cards. If a RAID controller is installed in
one of these slots, the controller will not function. Refer to your computer documentation for information
about the PCI Express slot.
LSI Corporation
- 10 -
MegaRAID LSIiBBU09 Intelligent Battery Backup Unit Quick Installation Guide
August 2012
Connecting a Remote LSIiBBU09 Unit to a MegaRAID SAS 9266 RAID Controller
Reinstalling the RAID Controller in the Computer
Figure 5 Reinstalling the RAID Controller
6. Reinstall the computer cover, and reattach the power cords.
7. Turn on the power to the computer.
Refer to the MegaRAID SAS Software User Guide for information about running the RAID configuration utility and
installing the software drivers.
LS I CORP . © 2010 AL L R IG HTS R E SERVED
Pb e1
AS SE MB LE D
IN CH INA
Ro HS
AsRP CB
E248037
94V 0
L
i
I
on
M
o
d
el:B
AT1S
1P-A
BB
U
P
/N
:
L
4
-2
54
0
7-
0
0
BBU
S
/
N
:S
AYWWSS
SSSs
s
Con
t
ai
ns:
So
ny
U
S
4
54
2
61
A
8T
Ce
ll
Recha
r
g
e
ab
l
eL
i-
Po
lyme
r
Batt
e
r
y
Pack
Rating
:
3.7
V
;1.5
9
Ah
;
5
.9
Wh
F
i
n
i
sh
ed
in Ch
in
a
WA
RN
ING
:T
h
e
b
a
t
te
r
y
used
i
nthi
s
d
e
v
ic
em
a
yp
resent
a
r
i
sk
o
f
f
ire
o
r
c
h
em
ical
b
u
r
n
i
f
m
istr
e
a
te
d
.D
O
N
O
T
d
i
sassemble,
h
ea
t
ab
o
ve
6
0
C
,c
rush
o
r
p
u
n
ct
ur
e
, s
ho
rt
c
i
rcui
te
xte
rn
a
l
c
onta
c
ts
,
o
r
d
i
s
p
o
s
eo
fi
nf
ire o
r
w
a
te
r
.
MH
2
9
57
7
L
i
-ion
!
L
3
-
2
5407
-
0
0
A
Edge of
Motherboard
PCI Express
Bracket
Screw
Press
Here
Press
Here
3_00898-00
LSI Corporation
- 11 -
MegaRAID LSIiBBU09 Intelligent Battery Backup Unit Quick Installation Guide
August 2012
Connecting a Remote LSIiBBU09 Unit on the System Chassis to a TMM02 Module on a
RAID Controller
Removing the RAID Controller from the Computer
Connecting a Remote LSIiBBU09 Unit on the System Chassis to a TMM02 Module on a
RAID Controller
The procedures in this section show how to connect a remote LSIiBBU09 unit on the system chassis to a MegaRAID
SAS 9265-8i RAID controller. You can connect the LSIiBBU09 unit to a MegaRAID SAS 9285-8e RAID controller in the
same way.
To connect a remote LSIiBBU09 unit to your RAID controller, perform the following tasks in order.
1. Remove the RAID controller from the computer. See Removing the RAID Controller from the Computer.
2. Connect the cable between the TMM module on the RAID controller and the remote LSIiBBU09 unit. See
Connecting the Cable Between the TMM02 Module on the RAID Controller and the Remote LSIiBBU09 Unit.
3. Reinstall the RAID controller in the computer. See Reinstalling the RAID Controller in the Computer on page 12.
Removing the RAID Controller from the Computer
Follow these steps to remove the RAID controller from the computer.
1. Turn off the power, and unplug the power cords.
2. Ground yourself, and make sure that the system is grounded.
3. Remove the cover from the computer, according to the instructions in the system users manual, to permit access
to the controller.
4. Unplug all cables from the controller, remove the screw that attaches the bracket to the computer chassis, and
carefully remove the controller from the slot.
5. Place the controller on a flat, clean, static-free surface, and continue with the next procedure.
Connecting the Cable Between the TMM02 Module on the RAID Controller and the Remote
LSIiBBU09 Unit
Follow these steps to connect the cable between the TMM02 module on the RAID controller and the LSIiBBU09 unit.
1. Mount the LSIiBBU09 unit to the chassis of your computer based on the location and the type of
mounting option.
2. With the controller on a flat, clean, static-free surface, ground yourself, and make sure that the system
is grounded.
3. Remove the cable included in the Remote Battery Kit (sold separately).
4. Insert one end of the cable into the 20-pin cable connector on the LSIiBBU09 unit and the other end into the
20-pin J1L1 cable connector on the TMM02 module, as the following figure shows.
Align the black triangles on the connectors to make sure that the connectors are connected correctly.
NOTE Because server and workstation chassis vary from vendor to vendor, no standard mounting option
exists that is compatible with the various system configurations. The LSIiBBU09 battery kit, in
combination with the Remote Battery Kit, includes the battery, daughtercard, cable, and screws. This
combination enables authorized resellers and chassis manufacturers to customize the location of the
remote battery to provide the most flexibility within various environments.
NOTE The cable connectors are polarized and can be inserted into the cable connectors on the TMM02
module and the LSIiBBU09 unit only if the rails on the cable connectors align with the slots on the other
connectors. Do not force the cable into the 20-pin connectors. The cable end inserts into the connector
with minimal resistance.
LSI Corporation
- 12 -
MegaRAID LSIiBBU09 Intelligent Battery Backup Unit Quick Installation Guide
August 2012
Connecting a Remote LSIiBBU09 Unit on the System Chassis to a TMM02 Module on a
RAID Controller
Reinstalling the RAID Controller in the Computer
Figure 6 Connecting the LSIiBBU09 Unit on the System Chassis to the TMM02 Module on the RAID Controller
Reinstalling the RAID Controller in the Computer
Follow these steps to reinstall the RAID controller in the computer.
1. With the power to the chassis still turned off and the power cords unplugged, make sure that the chassis is
grounded and has no AC power.
2. Insert the RAID controller in a PCI Express slot on the motherboard, as the following figure shows.
3. Press down gently, but firmly, to seat the controller correctly in the slot.
NOTE Some PCI Express slots support only PCI Express graphics cards. If a RAID controller is installed in
one of these slots, the controller will not function. Refer to your computer documentation for information
about the PCI Express slot.
85083-01
LSI CORP.© 2 010 ALL RIGHTS RESERVED
Pb e1
ASSEMBLED
IN CHINA
RoHS
AsRPCB
E248037
94V0
Li Ion
Model: BAT1S1P-A
BBU P/N: L4-25407-00
BBU S/N: SAYWWSSSSSss
Contains:
Sony US454261A8T Cell
Rechargeable Li-Polymer
Battery Pack
Rating:
3.7V; 1.59 Ah; 5.9Wh
Finished in China
WARNING: The battery used in this
device may present a risk of fire or
chemical burn if mistreated. DO NOT
disassemble, heat above 60C, crush or
puncture, short circuit external contacts,
or dispose of in fire or water.
MH29577
Li-ion
!
L
3
-
25
4
0
7
-
0
0
A
LSI Corporation
- 13 -
MegaRAID LSIiBBU09 Intelligent Battery Backup Unit Quick Installation Guide
August 2012
Connecting a LSIiBBU09 Unit on a Remote Mounting Board to a TMM02 Module on a
RAID Controller
Reinstalling the RAID Controller in the Computer
Figure 7 Reinstalling the RAID Controller
4. Secure the controller to the computer chassis with the bracket screw.
5. Reinstall the computer cover, and reattach the power cords.
6. Turn on the power to the computer.
Refer to the MegaRAID SAS Software User Guide for information about running the RAID configuration utility and
installing the software drivers.
Connecting a LSIiBBU09 Unit on a Remote Mounting Board to a TMM02 Module on a
RAID Controller
This section describes how to connect the LSIiBBU09 unit on the remote mounting board to your MegaRAID SAS RAID
controller. A cable connects the remote LSIiBBU09 unit on the remote mounting board to the TMM02 module on the
RAID controller.
The procedures in this section show how to connect the LSIiBBU09 unit on the remote mounting board to the
MegaRAID SAS 9265-8i RAID controller. You can connect the LSIiBBU09 unit on the remote mounting board to the
MegaRAID SAS 9285-8e RAID controller in the same way.
85083-02
Screw
PCI Socket
Edge of
Motherboard
Press
Here
Press
Here
LSI CORP.© 2 010 ALL RIGHTS RESERVED
Pb e1
ASSEMBLED
IN CHINA
RoHS
AsRPCB
E248037
94V0
Li Ion
Model: BAT1S1P-A
BBU P/N: L4-25407-00
BBU S/N: SAYWWSSSSSss
Contains:
Sony US454261A8T Cell
Rechargeable Li-Polymer
Battery Pack
Rating:
3.7V; 1.59 Ah; 5.9Wh
Finished in China
WARNING: The battery used in this
device may present a risk of fire or
chemical burn if mistreated. DO NOT
disassemble, heat above 60C, crush or
puncture, short circuit external contacts,
or dispose of in fire or water.
MH29577
Li-ion
!
L
3
-
25
4
0
7
-
0
0
A
LSI Corporation
- 14 -
MegaRAID LSIiBBU09 Intelligent Battery Backup Unit Quick Installation Guide
August 2012
Connecting a LSIiBBU09 Unit on a Remote Mounting Board to a TMM02 Module on a
RAID Controller
Removing the RAID Controller from the Computer
To connect a LSIiBBU09 unit on a remote mounting board to your RAID controller, perform the following tasks
in order.
1. Remove the RAID controller from the computer. See Removing the RAID Controller from the Computer.
2. Connect the cable between the TMM module on the RAID controller and the remote LSIiBBU09 unit. See
Connecting the Cable Between the TMM02 Module on the RAID Controller and the LSIiBBU09 Unit on the Remote
Mounting Board.
3. Reinstall the RAID controller in the computer. See Reinstalling the RAID Controller in the Computer on page 15.
4. Installing the remote mounting board in the computer. See Installing the Remote Mounting Board in the
Computer on page 16.
Removing the RAID Controller from the Computer
Follow these steps to remove the RAID controller from the computer.
1. Turn off the power, and unplug the power cords.
2. Ground yourself, and make sure that the system is grounded.
3. Remove the cover from the computer, according to the instructions in the system users manual, to permit access
to the controller.
4. Unplug all cables from the controller, remove the screw that attaches the bracket to the computer chassis, and
carefully remove the controller from the slot.
5. Place the controller on a flat, clean, static-free surface, and continue with the next procedure.
Connecting the Cable Between the TMM02 Module on the RAID Controller and the LSIiBBU09 Unit on
the Remote Mounting Board
Follow these steps to connect the cable between the TMM02 module on the RAID controller and the LSIiBBU09 unit
on the remote mounting board.
1. With the controller on a flat, clean, static-free surface, ground yourself, and make sure that the system
is grounded.
2. Remove the cable included in the Remote Battery Kit (sold separately).
3. Insert one end of the cable into the 20-pin cable connector on the LSIiBBU09 unit on the remote mounting board
and the other end into the 20-pin J1L1 cable connector on the TMM02 module, as the following figure shows.
Align the black triangles on the connectors to make sure that the connectors are connected correctly.
NOTE The cable connectors are polarized and can be inserted into the cable connectors on the TMM02
module and the LSIiBBU09 unit only if the rails on the cable connectors align with the slots on the other
connectors. Do not force the cable into the 20-pin connectors. The cable end inserts into the connector
with minimal resistance.
LSI Corporation
- 15 -
MegaRAID LSIiBBU09 Intelligent Battery Backup Unit Quick Installation Guide
August 2012
Connecting a LSIiBBU09 Unit on a Remote Mounting Board to a TMM02 Module on a
RAID Controller
Reinstalling the RAID Controller in the Computer
Figure 8 Connecting the LSIiBBU09 Unit on the Remote Mounting Board to the TMM02 Module on the RAID Controller
Reinstalling the RAID Controller in the Computer
Follow these steps to install the RAID controller in the computer.
1. With the power to the chassis still turned off and the power cords unplugged, make sure that the chassis is
grounded and has no AC power.
2. Insert the RAID controller in a PCI Express slot on the motherboard, as the following figure shows.
3. Press down gently, but firmly, to seat the controller correctly in the slot.
NOTE Some PCI Express slots support only PCI Express graphics cards. If a RAID controller is installed in
one of these slots, the controller will not function. Refer to your computer documentation for information
about the PCI Express slot.
85083-04
LSI CORP.© 2 010 ALL RIGHTS RESERVED
Pb e1
ASSEMBLED
IN CHINA
RoHS
AsRPCB
E248037
94V0
Li Ion
Model: BAT1S1P-A
BBU
P
/N
: L4-25407-00
BBU
S
/N
:SAYWWS
S
SSSss
Con
tains:
Sony US
4
54261A8T Cell
Rechargeable Li-Polymer
Battery Pack
Rating:
3.7V; 1.59 Ah; 5.9Wh
F
in
i
shed in China
WARNING: The bat
tery used inthis
de
v
ice m
a
y prese nt a
ri
sk of fire or
chemical burn if mistreated. D
O
N
O
T
disassemble, heat above
60C, crush or
puncture, short circuit external contacts,
or dispo
se of in fire or w
a
ter.
MH29577
Li-ion
!
L3
-
2540
7-00A
LSI Corporation
- 16 -
MegaRAID LSIiBBU09 Intelligent Battery Backup Unit Quick Installation Guide
August 2012
Connecting a LSIiBBU09 Unit on a Remote Mounting Board to a TMM02 Module on a
RAID Controller
Installing the Remote Mounting Board in the Computer
Figure 9 Reinstalling the RAID Controller
4. Secure the controller to the computer chassis with the bracket screw.
Installing the Remote Mounting Board in the Computer
Follow these steps to install the remote mounting board in the computer.
1. With the power to the chassis still turned off, and the power cords unplugged, make sure that the chassis is
grounded and has no AC power.
2. Insert the remote mounting board in a PCI Express slot on the motherboard, as the following figure shows.
3. Press down gently, but firmly, to seat the board correctly in the slot.
NOTE Some PCI Express slots support only PCI Express graphics cards. If the remote mounting board is
installed in one of these slots, the board will not function. Refer to your computer documentation for
information about the PCI Express slot.
LSI Corporation
- 17 -
MegaRAID LSIiBBU09 Intelligent Battery Backup Unit Quick Installation Guide
August 2012
Connecting a LSIiBBU09 Unit on a Remote Mounting Board to a TMM02 Module on a
RAID Controller
Installing the Remote Mounting Board in the Computer
Figure 10 Installing the Remote Mounting Board
4. Secure the remote mounting board to the computer chassis with the bracket screw.
5. Reinstall the computer cover, and reattach the power cords.
6. Turn on the power to the computer.
Refer to the MegaRAID SAS Software User Guide for information about running the RAID configuration utility and
installing the software drivers.
85083-06
LSI CORP.© 2 010 ALL RIGHTS RESERVED
Pb e1
ASSEMBLED
IN CHINA
RoHS
AsRPCB
E248037
94V0
Li Ion
Model: BAT1S1P-A
BBU
P
/N
: L4
-25407- 0
0
BBU
S
/N
:SAYWWS
S
SSSss
Con
t
ains:
Sony US
4
54261A8T Cell
Rechargeable Li-Polymer
Battery Pack
Rating:
3.7V; 1.59 Ah; 5.9Wh
F
in
i
shed in China
WARN
I
NG: The battery used inthis
d
ev
ice m
a
y prese nt a
ri
sk of fire o
r
chemical burn if mistreated. D
O
N
O
T
disassemble, heat above 60
C
, crush or
puncture, short circuit external contacts,
or dispo
se of in fire or wa
ter.
MH29577
Li-ion
!
L3-25407-00A
Press
Here
Press
Here
Screw
LSI Corporation
- 18 -
MegaRAID LSIiBBU09 Intelligent Battery Backup Unit Quick Installation Guide
August 2012
Technical Support
Installing the Remote Mounting Board in the Computer
Technical Support
For assistance in installing, configuring, or running the LSIiBBU09 unit, contact your LSI Technical
Support representative.
Click the following link to access the LSI Technical Support page for storage and board support:
http://www.lsi.com/support/storage/tech_support/index.html
From this page, you can send an email or call Technical Support, or submit a new support request and view its status.
Support Request:
http://www.lsi.com/support/support_form.html
Telephone Support:
http://www.lsi.com/support/storage/phone_tech_support/index.html
NOTE Record your controller serial number in a safe location in case you need to contact LSI about your RAID
controller.
NOTE The international toll-free number does not require country-specific access codes.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20

LSI MegaRAID LSIiBBU09 Intelligent Battery Backup Unit User guide

Type
User guide

LSI MegaRAID LSIiBBU09 Intelligent Battery Backup Unit protects the integrity of the cached data on a MegaRAID RAID controller for up to 48 hours (depending on the derated retention time selected) in case of a complete AC power failure or a brief power outage.

The LSIiBBU09 unit connects either directly or remotely to your RAID controller, depending on which RAID controller you have. It connects directly to the MegaRAID SAS 9266-4i RAID controller and the MegaRAID SAS 9266-8i RAID controller.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI