  • Hello! I am an AI chatbot trained to assist you with the Leica Microsystems EM AFS2 Application Note. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Application Note
Cell envelope structure of a thermotolerant y-proteobacterium
Acidithiobacillus sp., strain HV2/2
Material
Research
Life Science
Research
Medical
Research
Industrial
Manufacturing
Natural
Resources
related instrument Leica EM PACT2 / EM AFS2
2
Cell envelope structure of a Gram-negative ther-
motolerant y-proteobacterium
Acidithiobacillus
sp.,
strain HV2/2 and its interaction with pyrite
COURTESY
SAMPLE PREPARATION:
Cells of the the moderately thermophilic
Acidithiobacillus sp.
strain HV2/2, were centrifuged at 20,0009xg
and then cryo-immobilized by high-pressure freezing on gold carriers (EMPact 2, Leica Microsystems
GmbH, Vienna, Austria). Freeze substitution of the samples was performed in the automatic freeze subs-
titution unit Leica EM AFS2 (Leica Microsystems GmbH, Vienna, Austria) according to standard protocols
(9 h at -90°C; 8 h at -60°C; 8 h at -30°C). Two substitution solutions were used: 94.6% ethanol plus 5.4%
H2O, containing 0.5% glutardialdehyde, 1% formaldehyde, and 0.5% uranyl acetate, or acetone with
5% H2O, containing 2% OsO4 and 0.25% uranyl acetate. Finally, samples were washed twice in pure
ice-cold acetone at 0°C, gradually embedded in Epon at room temperature and cured at 60°C for 72 h.
Sections with a nominal thickness of about 50–70 nm were cut using an ultramicrotome (EM UC6, Leica
Microsystems GmbH, Vienna, Austria) with a diamond knife.
They were collected on uncoated copper grids (400 square mesh), and contrasted with 2% uranyl acetate
and lead citrate. Transmission electron microscopy (TEM) was performed on a Philips CM12 (FEI Co.,
Eindhoven, NL) with a LaB6 cathode at 120 keV. The micrographs were recorded with a slow-scan CCD
camera (software EMMENU 4; TVIPS GmbH, Gauting, Germany)
For more details see:
Analysis of the surface proteins of
Acidithiobacillus ferrooxidans
strain SP5/1 and the new, pyrite-oxi-
dizing
Acidithiobacillus
isolate HV2/2, and their possible involvement in pyrite oxidation. Klingl A,
Moissl-Eichinger C, Wanner G, Zweck J, Huber H, Thomm M, Rachel R.
Arch Microbiol. 2011 Dec;193(12):867-82.
Dr. Andreas Klingl
Zellbiologie & Elektronenmikroskopie
AG Prof. Uwe-G. Maier
Philipps Universität Marburg, Marburg
The website of the EM facility is:
http://www.synmikro.com/de/startseite/core-facilities/elektronenmikroskopie.html
LNT Application Note - ACIDTHIOBACILLES STRUCTURE
3
LEGEND FOR IMAGES:
Ultrathin sections of Epon-embedded cells, grown on pyrite crystallites. Freeze substitution was performed
with ethanol containing glutaraldehyde, formaldehyde and uranyl acetate.
(A)
Acidithiobacillus sp.
HV2/2. (B) Higher magnification of the selected area in (A).
Py: pyrite , C: cytoplasm; CM: cytoplasmic membrane; PP: periplasm with peptidoglycan;
OM: outer membrane; SL: S-layer; arrow heads: pili. .Bars: 200 nm (A) and 100 nm (B).
www.leica-microsystems.com
The statement by Ernst Leitz in 1907, With the User, For the User,”
describes the fruitful collaboration with end users and driving force of
innovation at Leica Microsystems. We have developed five brand
values to live up to this tradition: Pioneering, High-end Quality, Team
Spirit, Dedication to Science, and Continuous Improvement. For us,
living up to these values means: Living up to Life.
LIFE SCIENCE DIVISION - NANO TECHNOLOGY LNT
The Leica Microsystems Nano Technology Division’s focus is to
provide the most compehensive product portfolio for the preparation
of biological, medical and industrial samples for investigation in the
Electron and Light Microscope. Excellent Sample Preparation is a
prerequisite for perfect microscopy. Your image starts here!
Leica Microsystems – an international company with a strong network
of worldwide customer services:
Active worldwide Tel. Fax
Australia ∙ North Ryde +61 2 8870 3500 2 9878 1055
Austria ∙ Vienna +43 1 486 80 50 0 1 486 80 50 30
Belgium ∙ Diegem +32 2 790 98 50 2 790 98 68
Canada ∙ Concord/Ontario +1 800 248 0123 847 405 0164
Denmark ∙ Ballerup +45 4454 0101 4454 0111
France ∙ Nanterre Cedex +33 811 000 664 1 56 05 23 23
Germany ∙ Wetzlar +49 64 41 29 40 00 64 41 29 41 55
Italy ∙ Milan +39 02 574 861 02 574 03392
Japan ∙ Tokyo +81 3 5421 2800 3 5421 2896
Korea ∙ Seoul +82 2 514 65 43 2 514 65 48
Netherlands ∙ Rijswijk +31 70 4132 100 70 4132 109
People’s Rep. of China Hong Kong +852 2564 6699 2564 4163
∙ Shanghai +86 21 6387 6606 21 6387 6698
Portugal ∙ Lisbon +351 21 388 9112 21 385 4668
Singapore +65 6550 5999 6773 0628
Spain Barcelona +34 93 494 95 30 93 494 95 32
Sweden Kista +46 8 625 45 45 8 625 45 10
Switzerland ∙ Heerbrugg +41 71 726 34 34 71 726 34 44
United Kingdom ∙ Milton Keynes +44 800 298 2344 1908 246312
USA Buffalo Grove/lllinois +1 800 248 0123 847 405 0164
Leica EM AFS2/Leica EM PACT2 Application Note Acidthiobacilles Structure ∙07/2014 ∙
Copyright © by Leica Mikrosysteme GmbH, Vienna, Austria, 2014. Subject to modifications.
LEICA and the Leica Logo are registered trademarks of Leica Microsystems IR GmbH.
RELATED PRODUCTS
Leica EM PACT2
Leica EM AFS2
/