SkyLink M9 User manual

Category
Numeric keypads
Type
User manual
2in1 Alert/Alarm System
Model: M9
Protect your Home the Smart Way!
Quick Guide
1. Safety Information
4 x Door/
Window Sensor
Security Keypad
Mounting Accessories
Power Adapter
1. Plug in the power adapter to the Main Console and rotate the
antenna to the upright position for the best signal reception.
2. Insert 4 x AAA-Batteries in the Main Console for backup power
in case of power outage. (Optional)
2. Use a coin to open the Motion Sensor and insert an AA Battery.
Arm Home
Enter PIN number and press
Arm Home” to protect
while you’re at home. This
mode deactivates motion
sensors but leaves other
sensors activated.
Arm Away / Exit Away
Enter PIN number and press
the “Arm Away” to protect your
home when you’re away. This
mode activates or triggers the
alarm after a default set of time,
giving you enough time to get
in and out of your house to
arm/disarm the alarm system.
Disarm
Enter PIN number and tap the
Button to disarm the alarm
system.
Panic Button
Press the Panic Button to activate the alarm.
Main Console
2 x Motion Sensor
www.skylinkhome.com
NOTE: 9 x AAA and 2 x AA-Batteries are required to setup the
Alert/Alarm System. (AA/AAA Batteries are not included.)
2. Package Content 3. Setup the Main Console
This device complies with Part 15 of the FCC Rules. Operation
is subject to the following two conditions: (1) This device may
not cause harmful interference, and (2) This device must
accept any interference received, including interferences that
may cause undesired operation.
Changes or modifications to this unit not expressly approved by
the party responsible for compliance could void the users
authority to operate the equipment.
This equipment complies with the requirements relating to
electromagnetic compatibility, EN 301489-1, EN301489-3,
EN300220-1, EN300220-2 and EN60950-1. This equipment
conforms to the essential requirement of the 1999/5/EC
R&TTE Directive.
Warning:
CE Declaration of Conformity
7. Main Console Overview
(FRONT)
(BACK)
AC Adapter
Input Jack
Mute Button
To disable the beep sound temporary
.
Learn Button
To program and erase sensors.
Alert Notification Switch
Select the type of audio alert signal.
OFF | CHIME | ALERT
Antenna
LED Armed Indication
Shows if the Alarm System
is armed or disarmed.
LED Zone Indication
Shows the status of the sensors in
that zone or the status when
programming.
Power LED
Steady green is normal and flashing green indicates
low backup battery status.
1. Push the both sides in and open the cover of the Door/Window Sensor
to insert an AAA Battery.
4. Insert Batteries in the Sensors
9. Security Keypad Overview
NOTE: The backlight will turn on when pressing the buttons. The factory
default Pin is 0,0,0,0.
Arm Home
Select “Arm Home” to protect while
you’re at home. This mode
deactivates motion sensors but
leaves other sensors activated
with instant alarm.
Arm Away / Exit Away
Select “Arm Away” to protect your
home when you’re away. This mode
gives you 45 seconds exit delay to
leave the house. It will also give you
30 seconds entry delay to disarm the
system when you are back.
Disarm
Tap the Button to disarm
the alarm system.
Panic Button
Press and hold the Panic Button
for 3 sec. to activate the alarm.
8. Keychain Remote Overview
LED
Security Keychain
Remote
3. Undo the screw on the bottom side of the Security Keypad to remove the
back plate and insert an AAA Battery.
5. Testing the Door/Window Sensor
1. Slide the switch at the back of
the Main Console to alert mode.
2. Activate the Sensor by
separating the magnetic
contact of the sensor.
4. Move the magnetic contact
back to the sensor and the
alert sound will stop.
3. The Main Console will continue
beeping and the Zone LED
will flash if the door is open.
3. The main console will
beep continuously and flash
the Zone 1 LED if the
door is open.
6. Testing Motion Sensor
* As an energy saving feature, the motion sensor will not be triggered again unless
there is no motion detected for 15 seconds. In this case, the red LED will only flash
once indicating the motion is detected, but no signal is sent to the Internet Hub.
1. Slide the switch at the back of
the Main Console to alert mode.
2. Move in front of the motion
sensor to trigger the sensor.
The red LED on the sensor will
flash multiple times.
3. The Main Console will continue
beeping and the Zone 2 LED
will flash if a motion is detected.
4. The Main Console will stop
beeping and flashing the LED
after 15 seconds.
LED
10. Change passcode and install the Keypad
Place the sensor in the appropriate location:
Mount the Door/Window Sensor on your door or window
with double sided tape.
11. Install the Door/Window Sensor
1. Input current PIN [factory default 0 0 0 0] and press button.
2. Input the new PIN number followed by button.
3. Input the new PIN again and press button.
NOTE: The factory default passcode is 0,0,0,0. The passcode can be 2-8 digits
long and with a combination of buttons from 0-6.
If the Keypad emits 2 beep, your pin has been successfully changed.
If it emits a long error beep, start from step 1 again.
Back
Plate
1. Undo the screw on the bottom of the Keypad and remove the back plate.
2. Mount the back plate with the included Screws.
3. Attach the Keypad on the back plate and tighten the screw on the
bottom of the Keypad.
Screw
LED
NOTE: The Door/Window Sensors are factory preset in Zone 1.
NOTE: The Motion Sensors are factory preset in Zone 2.
When chime mode is enabled
and your Skylink Alarm System
is disarmed, the Main Console will
beep every time a sensor gets
triggered.
When alert mode is enabled
and your Skylink Alarm System
is disarmed, the Main Console will
beep continously when a window/
door is opened or motion is detected
until the sensor is deactivated.
Chime Mode Alert Mode
14. Enable Chime or Alert Mode
23. Warranty / Customer Service20. Sensor Failure/Battery Indication 21. FAQ
This product is guaranteed to be free of defects in materials and
workmanship for 1 year from the date of purchase. If this product
is defective, call 1-800-304-1187 for repair or replacement parts.
Guarantee does not include normal wear and tear or batteries.
If you have any questions, problems or missing parts, please call:
Skylink Customer Support
1-800-304-1187
9:00am – 5:00pm EST, Monday-Friday.
Or e-mail us at suppor[email protected]
www.skylinkhome.com
P/N:101Y184
- You must program the sensor or keypad to zone 1 of the main
unit before they can work together.
- Ensure to input the correct password on the Keypad.
- Ensure to input the correct password if enable the password
feature in keychain remote.
The Main Console does not respond to the sensor, keychain remote
or Keypad Control?
- You must erase all the sensors/remotes in that zone and then
program the remote you want to keep.
Can I erase just one sensor or remote from a zone?
- You need to test each remote/keypad/sensor individually.
I have multiple remotes in a zone and the zone LED keep flashing
that is a remote failure, how do I know which sensor/remote
is having the problem?
- It is recommended to power up the control panel with AC adapter.
Install batteries to the Control Panel so it can continue to operate
during power failure.
Can I only use battery to power up the Control Panel?
If the signal is lost between the sensor and the Main Console,
or if the battery in the sensor is low, the zone LED light will
start blinking fast.
Take the following steps to troubleshoot the problem:
1. Check if the sensor is located where it should be, and whether
there is any physical damage to the sensor.
2. If the failed sensor is not physically damaged, try to activate the
sensor and see if the Main Console reacts to the activation.
3. If not, try to remove the sensor from its location, and bring it
closer to Main Console and then activate the sensor. It is possible
that the sensor is installed too far from the Main Console and it
cannot establish a steady communication with the Main Console.
If this is the case, please install the sensor closer to the
Main Console.
4. Replace the battery of the sensor in that zone if the Main Console
does not respond even when the sensor is near the Main Console.
NOTE: If you have multiple sensors in a zone, you may test the function
of each sensor to identify which sensor is having a problem.
1. Slide the switch at the back of the Main Console to enable Chime
or Alert Mode.
15. Alert Notication
The motion sensor can be mounted with a double
sided tape or screws in a corner, straight wall, ceiling or
stand freely by itself.
22. Erasing the Sensors/Remote from the Main Console
1. Remove the power adapter from the Main Console.
2. Press and hold the Learn Button and plug in the power
adapter back in the Main Console.
3. Release the learn button when the red LED are flashing on
the Main Console.
4. You have successfully erased all sensors and remotes from the
Main Console.
NOTE: To erase any sensors or remote from the Main Console, you need
reset the Main Console and learn the sensors/remotes you wish to keep.
LEDAC Adapter
Learn Button
Arm Home
Arm Away
13. Operation of Alarm System
1. Arm your alarm system by
pressing the “Arm Away” or
Arm Home” button on
the Security Keychain Remote or
by entering your PIN number
followed by the “Arm Home” or
Arm Away” button on the
Security Keypad Console.
2. When a sensor get triggered,
the main console will sound a
siren and the corresponding
zone LED will flash for 3 minutes.
Arm Away
Arm Away
Arm Home
3. Press the “Disarm Button” on
your Keychain Remote or enter
the PIN number and press
the “Disarm Button on the
Keypad Console to deactivate the
alarm system.
12. Install the Motion Sensor
Place the sensor in the appropriate location:
ZONE 1 SENSORS - 1 Beep , Pause , 1 Beep , Pause ... etc.
ZONE 2 SENSORS - 2 Beep , Pause , 2 Beep , Pause ... etc.
ZONE 3 SENSORS - 3 Beep , Pause , 3 Beep , Pause ... etc.
ZONE 4 SENSORS - 4 Beep , Pause , 4 Beep , Pause ... etc.
When the Alert Mode is activated, you can identify the
zone number by the number of beeps.
The beeping will continue until the sensor is deactivated. When the
Main Console receives a signal from the motion sensor, the Main
Console will beep and the LED will flash on the corresponding zone
for 15 seconds.
Press the MUTE button if you want to temporarily disable the
beeping sound.
Disarm
Disarm
17. Program W/D Sensor to Main Console
1. Press and hold the “Learn”
button for 3 seconds, until
the Zone 1 red LED flash.
2. Zone 1 is selected. Press the
learn button to select the Zone
you want to program the sensor.
3. Activate the Sensor
by separating the magnetic
contact of the sensor.
4. Once the sensor is programmed,
the Main Console will beep once and
the corresponding zone red LED
will be off.
you want to program the sensor.
18. Program Motion Sensor to Main Console
1. Press and hold the “Learn”
button for 3 seconds, until
the Zone 1 red LED flash.
2. Zone 1 is selected. Press the
learn button to select the Zone
you want to program the sensor.
3. Open the Motion Sensor
cover with a coin and press
the learn button.
4. Once the sensor is programmed,
the Main Console will beep once
and the corresponding zone red
LED will be off.
you want to program the sensor.
19. Zone Settings
16. Program Security Remote/Keypad Console
1. Press and hold the “Learn”
button for 3 seconds, until
the Zone 1 LED is flash.
3.
Once the Security Keychain
Remote or Keypad Console is
programmed, the Main Console
will beep once and the
corresponding zone LED will be
off.
2. Press any button to program the
Security Keychain Remote or enter
the PIN number followed by the
“Disarm Button” to program
the Security Keypad Console.
NOTE: The Keychain Remote must be programmed in Zone 1. You can
program up to 4 Remotes or Keypads with the Main Console.
Refer to the chart below for the 2 zone operation modes. The unit
is currently set at Default Zone Setting Mode.
Change between Default Zone and All Alert Zone Mode:
1. Power up the Main Console.
2. Press and hold the “Learn” and “Mute” button simultaneously
for 5 seconds, until you hear the beep.
3. If you hear one beep, you are in “All Alert Zone Setting” and if
you hear 2 beeps, you are in “Default Zone Setting”.
4. Release both button.
Zone Setting
Default Zone SettingZone
Zone
1 & 2
Special Zone Setting Suggestion Application
Zone 3
Zone 4
Alert when disarmed,
Alarm when armed.
Alert when disarmed,
Alarm when armed.
Alert when disarmed,
Alarm when armed.
Alert when disarmed,
Alarm when armed.
No alert when disarmed,
but will alarm when armed.
Alert Only,
No Alarm.
For outdoor sensor.
Indoor motion sensor in
a high traffice area.
Most sensor, except for sensors
in outdoor or high traffic area.
NOTE: You can program up to 4 sensors in each Zone.
NOTE: You can program up to 4 sensors in each Zone.
Repeat the above steps to change between 2 operation modes.
  • Page 1 1
  • Page 2 2

SkyLink M9 User manual

Category
Numeric keypads
Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI