  • Hello! I am an AI chatbot trained to assist you with the American Weigh Scales AC PRO-200 User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
American Weigh Scales
ACP-200 (200x0.01g)
ACP-500 (500x0.1g)
User Manual
ACPro Series
Copyright © 2010 American Weigh Scales, Inc.
All rights reserved. Rev. 2.0
ACPro Series User Manual
 ThankyouforpurchasingtheAmericanWeigh
ACProSeriesdigitalpocketscale.Pleasereadalloperating
instructionscarefullybeforeuse.Scalesareprecision
measuringdevicesandshouldalwaysbehandledwith
propercare.Toensureyearsofreliableservice,keepthese
simpletipsinmind:
• Donotexceedthescale’smaximumcapacity.
Overloadingyourscalecanpermanentlydamageit!
• Avoidexposuretoextremeheatorcold.Scales
performbestatnormalroomtemperature.If
temperatureshavechangeddramatically,calibration
adjustmentmaybenecessary.
• Allowyourscaletowarmupfor30-60secondsbefore
performingcalibration(ifavailable).
• Storeyourscaleinaclean,drylocation.Dust,dirt,
andmoisturecanaccumulateontheweighing
sensorsandelectronicscausinginaccuracyor
malfunction.
• Avoidusingyourscaleincloseproximitytostrong
radiowaveemittingdevicessuchascomputers,cash
registers,andcordlessphones.
• Alwaysweighonaatandlevelsurface,freefrom
vibrationsanddrafts.Thecornerofaroomisusually
themoststable.
• Gentlyapplyallitemstobeweighed.Donotdrop
itemsontotheweighingplatform.
• Avoiddroppingyourscale.Thewarrantydoesnot
coverdamageduetoroughtreatmentoroverload.
• Checkthebatteriesrstifyouarehavinganytrouble
withyourscale.Thissimplestepcanremedymost
scaleissues.
• Donotdisassembleyourscale.Thisproductcontains
nouserserviceableparts.
ON/OFF MODE TARE PCS
g
ct
I. Part List
1. Scale
2. UserManualandTermsandConditions
3. RemovableCover/ExpansionTray
4. AAABatteries(x2)
II. Key Description
III. Battery Installation
1. Beforeusingthescaleforthersttime,check
thebatterycompartmentandremoveanyplastic
insulationstripsorpackagingthatmaybeinplaceto
preventbatterydrainageduringshipping/storage.
2. Ifyouarereplacingthebatteries,makesurethe
positiveandnegativecontactsareproperlyaligned.
ON/OFF Key
Mode Key
Tare Key
Pcs. Key
ON/OFF MODE TARE PCS
g
ct
ACPro Series User Manual
IV. Operation
1. Placethescaleonaat,levelsurfaceandpressthe
ON/OFFkeytoturnthescaleon.
2. Oncethestart-upprocesscompletesandthescale
goestozero,youarereadytoweigh.
3. Placethequantitytobeweighedontotheweighing
platform.
4. Waitacouplesecondsforthedisplaytostabilize
beforetakingaweightreading.
V. Changing the Unit of Measure
1. PresstheMODEkeytochangethescale’s
displayedunitofmeasure.
2. Ifthescaleisturnedoff,thenbackon,itwilldefault
tothelastunitused.
ACP-200 Units:g(gram) dwt(pennyweight) ct
(carat) gn(grain)
ACP-500 Units:g(gram) oz(ounce) ozt(troy
ounce) dwt(pennyweight)
VI. Using the Tare Feature
Youcanusethisscale’starefeaturetosubtracttheweight
ofanemptycontainerorvesselfornetweightdetermination.
NOTE:Theweightofthecontainerwillsubtractfromthe
availablecapacity.
1. Placetheemptycontainerorvesselontheweighing
platform.
2. PresstheTAREkeyonce.Thedisplaywillthen
resettozero.Ifthecontainerisremoved,it’sweight
willbedisplayedasanegativenumber.
3. Youmaynowllthecontainerwiththequantityto
beweighed.Thedisplaywillshowthenetweightof
thecontents.
4. Toreturntonormalweightdisplay(grossweight),
removeanyitemsfromtheweighingplatformand
pressthe TAREkeyagaintore-zerothescale.
VII. Using the Counting Feature
1. PresstheON/OFFkeytoturnthescaleon.
2. Placeasamplequantityoftheitemsbeingweighed
ontheplatform.Thisquantityshouldeitherbe25,
50,75,or100pieces.
3. Oncetheweightisstable,pressandholdthePCS
keytoentercountingmodesetup.
4. Thecurrentsamplesizewillbedisplayedonthe
bottomrightoftheLCD.
5. PresstheMODEkeytochangeitbetween25,50,
75,or100andpressPCStoconrm.Thecount
willbedisplayedonthebottomrightoftheLCD.
Youmaynowaddmoreitems.Asitemsareremove
itemsandthecountwillupdateautomatically.
VIII. Calibration
Calibrationandadjustmentareperformedatthefactory.
However,theweighingrangecanshiftslightlyduring
shipping.Also,duetochangesinlocalaccelerationofgravity
aroundtheworld,adjustmentisrecommendedwhenmoving
thescalefromonelocationtoanother.Tocheckcalibration:
1. Placetherequiredcalibrationweightonthescale
andnotethedisplayedvalue.
2. Ifthedisplayedvalueisnotwithinacceptable
tolerance(seechartonnextpage),adjustmentis
required.
ACPro Series User Manual
Model Acceptable
Tolerance(±)
Calibration
Weights
Recommended
AccuracyClass
ACP-200 0.02g 100g,200g OIMLM2
ACP-500 0.2g 500g OIMLM2
IX. Calibration Adjustment
1. PresstheON/OFFkeytoturnthescaleon.
2. PressandholdtheMODEkeyforthreeseconds
untilthedisplayshows“CAL”thenrelease.
3. PresstheMODEkeyagain,andtheLCDwillash
therstcalibrationweight.Placetherequiredweight
onthemiddleoftheplatform
4. TheLCDwillashthenashthesecondrequired
calibrationweight.Placetherequiredcalibration
weightonthemiddleoftheplatform.Skipthisstep
formodelACP-500.
5. TheLCDwilldisplay“PASS”andreturntonormal
weighingmode.Calibrationiscomplete!
X. Troubleshooting
• Problem:Scalewillnotturnon
• Solution: Checkthebattery
• Problem: Displayedweightuctuatesrandomly
• Solution: Makesureyourworkspaceisstableand
freeofanyaircurrentsorvibration
• Problem:Displayedweightisinaccurate
• Solution:Performacalibrationadjustment
XI. Error Codes
1. OUTZ-Zerorangehasshifted.Performcalibration
adjustment.Iftheproblempersists,theloadcellmay
bepermanentlydamagedduetooverloading.
2. O-LD-Maximumcapacityexceeded.Removethe
extraweighttoavoiddamagingtheloadcell.
3. LO -Batteriesarelow.Replacethebatteries.
4. UNSE -Thescaleisunstable.Usethescaleina
morestableposition.
ACP-200 ACP-500
Max.Capacity 200g 500g
Readability 0.01g 0.1g
Power 2xAAABatteries
Dimensions 2.8x4.8x0.8in.
PlatformDimensions 2.5x3.0in.
Warranty 10YearLimitedWarranty
/