Hayward XStream CC1000 Owner's manual

Category
Above ground pool accessories
Type
Owner's manual

Hayward XStream CC1000 is a powerful and versatile pool pump, designed to keep your pool water clean and refreshing. With its advanced hydraulic design, the CC1000 delivers exceptional flow rates and energy efficiency, ensuring that your pool water is always crystal clear. The pump is also equipped with a self-priming feature, making it easy to start up and operate, even after extended periods of inactivity. Additionally, the CC1000 is built with durable materials and features a corrosion-resistant finish, ensuring long-lasting performance and reliability.

Hayward XStream CC1000 is a powerful and versatile pool pump, designed to keep your pool water clean and refreshing. With its advanced hydraulic design, the CC1000 delivers exceptional flow rates and energy efficiency, ensuring that your pool water is always crystal clear. The pump is also equipped with a self-priming feature, making it easy to start up and operate, even after extended periods of inactivity. Additionally, the CC1000 is built with durable materials and features a corrosion-resistant finish, ensuring long-lasting performance and reliability.

USE ONLY HAYWARD GENUINE REPLACEMENT PARTS 1
Basic safety precautions s
h
ou
ld
a
l
ways
b
e fo
ll
owe
d
, inc
l
u
d
ing t
h
e fo
ll
owing: Fai
l
ure to fo
ll
ow instructions
can cause severe injury and/or death.
This is the safety-alert symbol. When you see this symbol on your equipment or in this manual, look for
one of the following signal words and be alert to the potential for personal injury.
WARNING warns about hazards that could cause serious personal injury, death or major property
damage and if ignored presents a potential hazard.
CAUTION warns about hazards that will or can cause minor or moderate personal injury and/or property
damage and if ignored presents a potential hazard. It can also make consumers aware of actions that are
unpredictable and unsafe.
The NOTICE label indicates special instructions that are important but not related to hazards.
XStream
Owner’s Manual
MODELS: CC1000, CC1500, and Systems
IMPORTANT SAFETY INSTRUCTIONS
Contents
Product Warnings………….………2
Introduction……….…………..…..…3
Installation……….……………...…..3
Replacement Parts………..…….…7
Warranty & Registration …………8
Hayward Pool Products
620 Division Street, Elizabeth, NJ 07207
Phone: (908) 355-7995
www.ha
y
ward.com
ISCC100
Rev
G
WAR
N
follow ins
t
WA
R
Suction in
s
cause sev
e
Hair Entra
Limb Entr
cracked, m
Body Suc
t
Eviscerati
outlet sum
disembow
e
Mechanic
opening of
WAR
o
W
m
(
3
o D
o D
o T
h
o N
a
t
o R
e
o I
n
C
P
o I
n
WA
R
suction o
u
WA
R
other mat
e
WA
R
replaced
a
CAU
T
their bein
g
or climb o
n
heaters m
u
WAR
during star
Failure to f
o
filter housi
Before ser
v
air relief v
a
system wa
t
starting sy
s
of water (n
o
WAR
N
separation
lock ring.
B
operate po
operate po
Never ope
r
Purging th
e
nearby. U
s
N
ING
-
Rea
d
t
ructions can
c
R
NING
– Suc
s
uction outlets
e
re injury and/
o
pment
- Hair c
a
a
pment
- A lim
b
issing, or not s
t
ion Entrapm
e
on/ Disembo
w
p
or suction ou
e
lment.
a
l Entrapmen
a suction outl
e
NING
- To R
e
W
hen outlets ar
e
m
ust be installe
d
3
’) [1 meter] a
p
ual suction fitt
i
ual suction fitt
i
h
e maximum s
y
ever use Pool
o
t
tached.
e
place damag
e
n
addition two
o
P
SC guidelines
n
stallation of a
v
R
NING
Fail
u
u
tlets can resu
R
NING
Fail
e
rial can resul
t
R
NING
Suc
a
t least every t
e
T
ION
Com
p
g
used as mea
n
n
this product.
u
st be position
e
NING
– Haz
t
up, normal o
p
o
llow safety an
ng and clamp
d
v
icing pool and
a
lve must be in
t
er to return ba
c
s
tem pump, ful
o
t air or air an
d
N
ING
Sep
a
of pump and/
o
B
efore servicin
g
ol and spa circ
u
ol and spa circ
u
r
ate or test th
e
e
system with c
s
e only a low pr
USE ON
L
d
and follo
w
c
ause severe i
n
tion Entrap
m
and/or suctio
n
o
r death due to
a
n become ent
a
b
inserted into
ecurely attach
e
e
nt
- A negative
w
elment
- A n
e
tlet cover whic
h
t
- There is pot
e
e
t cover resulti
n
e
duce the ris
e
small enough
d
. Suction out
l
p
art, as measur
e
ngs shall be pl
ngs shall not b
y
stem flow rate
o
r Spa if any su
c
e
d, broken, cra
c
o
r more suction
, follow all Nati
v
acuum releas
e
u
re to remove
lt in an increa
s
ure to keep su
t
in an increas
tion outlet co
m
e
n years or if
f
p
onents such
n
s of access t
o
Closely superv
i
e
d to prevent c
h
ardous Pres
s
p
eration, and a
f
d operation in
s
d
ue to pressure
spa water circ
u
open position.
c
k to the pool.
ly open filter m
water) is disc
h
a
ration Haza
r
o
r filter compo
n
g
pool and spa
u
lation system
u
lation system
e
circulation s
y
o
mpressed air
essure (below
5
L
Y HAYWARD
G
w
all instru
n
jury and/or d
m
ent Hazard.
n
outlet covers
w
the following e
a
ngled in sucti
o
an opening of
a
e
d can result in
pressure appli
e
gative pressu
r
h
is, damaged,
e
ntial for jewelr
y
n
g in mechanic
a
k of Entrapm
to be blocked
l
ets in the sam
e
e
d from near p
o
aced in such l
o
e located on s
e
shall not exce
e
c
tion outlet co
m
c
ked, missing,
o
outlets per pu
m
onal, State, an
e
or vent syste
m
pressure test
s
e potential f
o
ction outlet c
o
e
potential fo
r
m
ponents hav
e
f
ound to be da
as the filtrati
o
o
the pool by
y
i
se children at
a
h
ildren from us
s
ure.
Pool an
d
f
ter pump shut
s
tructions coul
d
in the system,
u
lation system,
Before startin
g
Do not change
anual air relief
arged.
r
d. Failure to f
o
n
ents. Strainer
circulation sys
t
if a system co
m
unless
f
ilter m
a
y
stem at more
can cause com
5
PSI), high vol
G
ENUINE REP
L
ctions
in thi
eath.
w
hich are, da
m
ntrapment haz
o
n outlet cover
.
a
suction outle
t
a mechanical
b
e
d to a large p
o
r
e applied dire
c
broken, crack
e
y
, swimsuit, ha
a
l entrapment.
ent Hazards:
by a person, a
m
e
plane (i.e. flo
o
o
int to near poi
o
cations and di
s
e
ating areas or
e
d 6 ft/sec in t
h
m
ponent is da
m
o
r not securely
m
p installed in
d Local codes
a
m
, which reliev
e
plugs and/or
p
o
r suction entr
a
o
mponents cl
e
r
suction entra
e
a finite life,
t
maged, broke
n
n system, pu
m
y
oung children
a
ll times. Com
p
ing them as a
m
d
spa water circ
off. Stand cle
a
d
result in viole
which could c
a
all system an
d
g
system pump
filter control v
a
valve. Do not
c
o
llow safety an
cover must be
t
em, filters ma
n
m
ponent is not
a
nual air relief
than 30 PSI.
D
ponents to ex
p
u
me blower w
h
LACEMENT P
A
i
s owner’s ma
n
m
aged, broken,
ards:
.
t
sump or sucti
o
b
ind or swellin
g
o
rtion of the bo
c
tly to the intes
e
d, missing, or
a
ir decorations,
:
minimum of tw
o
r or wall), mu
s
i
nt.
stances to avo
i
on the backre
s
h
e return line.
m
aged, broken,
attached sucti
o
accordance w
i
a
pplicable.
e
s entrapping
s
p
lugs used in
w
a
pment as de
s
e
ar of debris,
s
pment as des
c
t
he cover/grat
n, cracked, mi
m
ps and heate
. To reduce ris
ponents such
a
m
eans of acces
ulation system
a
r of circulation
nt separation
o
a
use property
d
d
pump control
s
p
, all system va
l
a
lve position
w
c
lose filter ma
n
d operation in
s
properly secur
e
n
ual air relief v
a
assembled pr
o
valve body is i
n
Do not purge t
p
lode, with risk
h
en air purging
A
RTS
n
ual and on th
cracked, missi
on outlet cove
r
g
of the limb.
o
dy or limbs ca
n
tines through
a
unsecured can
finger, toe or
k
w
o functioning
s
s
t be installed
a
i
d “dual block
a
s
t for such seat
i
cracked, miss
i
o
n outlet comp
i
th latest ASM
E
s
uction, is reco
w
interization
o
s
cribed above
.
s
uch as leaves
c
ribed above.
e should be i
n
ssing, or not
s
r must be pos
s
k of injury, do
n
a
s the filtration
s to the pool.
s operate und
e
n
system equip
m
o
f the pump ho
u
d
amage, sever
e
s
must be in of
f
l
ves must be s
e
w
hile system pu
n
ual air relief v
a
s
tructions coul
d
ed to pump ho
u
a
lve must be i
n
o
perly, damage
n
locked positi
o
t
he system wit
of severe injur
y
the pump, filte
e equipment.
ng, or unsecur
e
r
that is damag
e
n
result in an e
n
a
n unprotected
result in evisc
e
k
nuckle to be c
a
s
uction outlets
a
minimum of t
h
a
ge” by a user.
i
ng areas.
i
ng, or not sec
u
onents immed
i
E
, APSP Standa
r
mmended.
o
f the pool/sp
.
, dirt, hair, pa
p
n
spected freq
u
s
ecurely attac
h
itioned so as
t
n
ot permit chil
d
system, pump
s
e
r hazardous p
r
m
ent during pu
u
sing and cove
e
personal inju
r
f
position and
f
e
t in a position
mp is running.
a
lve until a ste
a
d
result in viole
u
sing with stra
i
n
open position
d, or missing.
o
n in filter upp
e
h compressed
y
or death to a
n
r, or piping.
Failure to
e
d can
e
d, broken,
n
trapment.
suction
e
ration/
a
ught in an
per pump
h
ree feet
u
rely
i
ately.
r
ds and
a from the
p
er and
u
ently and
h
ed.
t
o prevent
d
ren to use
s
, and
r
essure
mp start up.
r, and/or
r
y, or death.
f
ilter manual
to allow
Before
a
dy stream
e
nt
i
ner cover
. Do not
Do not
e
r body.
air.
n
yone
2
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS 3
WARNING Risk of Electric Shock. All electrical wiring MUST be in conformance with applicable local codes,
regulations, and the National Electric Code (NEC). Hazardous voltage can shock, burn, and cause death or serious property
damage. To reduce the risk of electric shock, do NOT use an extension cord to connect unit to electric supply. Provide a
properly located electrical receptacle. Before working on any electrical equipment, turn off power supply to the equipment.
To reduce the risk of electric shock replace damaged wiring immediately. Locate conduit to prevent abuse from lawn mowers,
hedge trimmers and other equipment. Do NOT ground to a gas supply line.
WARNING Risk of Electric Shock Failure to ground all electrical equipment can cause serious or fatal electrical
shock hazard. Electrical ground all electrical equipment before connecting to electrical power supply.
WARNING Risk of Electric Shock Failure to bond all electrical equipment to pool structure will increase risk for
electrocution and could result in injury or death. To reduce the risk of electric shock, see installation instructions and consult
a professional electrician on how to bond all electrical equipment. Also, contact a licensed electrician for information on local
electrical codes for bonding requirements.
Notes to electrician: Use a solid copper conductor, size 8 or larger. Run a continuous wire from external bonding lug to
reinforcing rod or mesh. Connect a No. 8 AWG (8.4 mm2) [No. 6 AWG (13.3 mm2) for Canada] solid copper bonding wire to the
pressure wire connector provided on the electrical equipment and to all metal parts of swimming pool, spa, or hot tub, and
metal piping (except gas piping), and conduit within 5 ft. (1.5 m) of inside walls of swimming pool, spa, or hot tub.
IMPORTANT - Reference NEC codes for all wiring standards including, but not limited to, grounding, bonding and other general
wiring procedures.
WARNING Risk of Electric Shock . The electrical equipment must be connected only to a supply circuit that is
protected by a ground-fault circuit-interrupter (GFCI). Such a GFCI should be provided by the installer and should be tested on
a routine basis. To test the GFCI, push the test button. The GFCI should interrupt power. Push reset button. Power should be
restored. If the GFCI fails to operate in this manner, the GFCI is defective. If the GFCI interrupts power to the electrical
equipment without the test button being pushed, a ground current is flowing, indicating the possibility of an electrical shock.
Do not use this electrical equipment. Disconnect the electrical equipment and have the problem corrected by a qualified
service representative before using.
CAUTION – HAYWARD® pumps are intended for use with permanently-installed pools and may be used with hot tubs
and spas if so marked. Do not use with storable pools. A permanently-installed pool is constructed in or on the ground or in a
building such that it cannot be readily disassembled for storage. A storable pool is constructed so that it is capable of being
readily disassembled for storage and reassembled to its original integrity.
WARNING Risk of Hyperthermia. To avoid hyperthermia the following “Safety Rules for Hot Tubs” are
recommended by the U.S. Consumer Product Safety Commission.
1. Spa or hot tub water temperatures should never exceed 104°F [40°C]. A temperature of 100°F [38°C] is
considered safe for a healthy adult. Special caution is suggested for young children. Prolonged
immersion in hot water can induce hyperthermia.
2. Drinking of alcoholic beverages before or during spa or hot tub use can cause drowsiness, which
could lead to unconsciousness and subsequently result in drowning.
3. Pregnant women beware! Soaking in water above 100°F [38°C] can cause fetal damage during the first
three months of pregnancy (resulting in the birth of a brain-damaged or deformed child). Pregnant women
should adhere to the 100°F [38°C] maximum rule.
4. Before entering the spa or hot tub, users should check the water temperature with an accurate ther-
mometer; spa or hot tub thermostats may err in regulating water temperatures by as much as 4°F
(2.2°C).
5. Persons taking medications, which induce drowsiness, such as tranquilizers, antihistamines or anti-
coagulants, should not use spas or hot tubs.
6. If the pool/spa is used for therapy, it should be done with the advice of a physician. Always stir pool/ spa
water before entering the pool/spa to mix in any hot surface layer of water that might exceed healthful
temperature limits and cause injury. Do not tamper with controls, because scalding can result if safety
controls are not in proper working order.
7. Persons with a medical history of heart disease, circulatory problems, diabetes or blood pressure
problems should obtain a physician’s advice before using spas or hot tubs.
8. Hyperthermia occurs when the internal temperature of the body reaches a level several degrees above
normal body temperature of 98.6°F [37°C]. The symptoms of Hyperthermia include: drowsiness,
lethargy, dizziness, fainting, and an increase in the internal temperature of the body.
The effects of Hyperthermia include:
1. Unawareness of impending danger.
2. Failure to perceive heat.
3. Failure to recognize the need to leave the spa.
4. Physical inability to exit the spa.
5. Fetal damage in pregnant women.
6. Unconsciousness resulting in danger of drowning.
SAVE THESE INSTRUCTIONS
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS 4
The Hayward®
X
Stream Filtration Series is specifically designed for the demanding requirements of today’s
above-ground swimming pools. The advanced design reduces maintenance requirements while providing
superior performance.
The
X
Stream™ Filtration Series is intended for use on permanently installed above-ground swimming pools and
may also be used with hot tubs and spas if so marked. Do NOT use with storable pools. A permanently installed
pool is constructed in or on the ground or in a building such that it cannot be readily disassembled for storage. A
storable pool is constructed so that it is capable of being readily disassembled for storage and reassembled to its
original integrity.
Model No. CC1000 CC1500
Effective Filtration Area 100 FT² 150 FT²
Design Flow Rate 80 GPM 100 GPM
Maximum Working
Pressure 30 PSI 30 PSI
Required Clearance:
Side 18” 18”
Above 24” 30”
Replacement Hayward
Cartridge CCX1000RE CCX1500RE
Turnover
8
Hours
38,400
GAL
48,000
GAL
12
Hours
57,600
GAL
72,000
GAL
General Information
Introduction
This manual contains information for the proper installation and operation of the Hayward®
X
Stream™
Filtration Series. All XStream™ Filtration models are high performance, above-ground swimming pool
filters. Instructions in this manual MUST be followed precisely.
Product Features
Engineered for easy use with flexible or rigid plumbing.
Sleek, flush mounted pressure gauge.
Extra large dirt capacity.
Quick release, high capacity air relief valve.
Glass reinforced, non-corrosive filter tank will provide years of trouble-free operation.
Easy-Lok™ ring design allows quick access to all internal components in a single turn.
Installation Instructions
Filter Location
This product is designed for outdoor use. It is strongly advised to protect the electrical components from
the weather. Set the filter on firm, level ground. Select a well-drained area, one that will not flood when
it rains. Position the filter so that it may drain by gravity. It requires free circulation of air for cooling. Do
not install in a damp or non-ventilated location. The tank should be positioned for easy access to the
internals, pressure gauge, and air relief valve.
Sta
Plumb
i
To facilit
a
installin
g
Use TFE
t
thoroug
h
plastic c
male fitti
beginnin
The pum
p
fitting pa
hand an
d
is reduc
e
connect
o
connect
o
used, be
All plum
b
male-en
d
tape or p
Screw th
e
using a
w
necessa
r
toleranc
e
only cau
s
are reco
m
Connect
t
skimmer
plumbin
g
filter bo
d
A filter d
r
and is al
l
draining.
aid in th
e
or draini
n
rt-Up & O
New Ins
t
1.
Close dra
i
2. Secure an
W
A
Fa
To
3. Open air
r
4. Open val
v
W
F
a
s
e
s
u
5. Prime an
d
6. Once air
h
valve and
i
ng
a
te servicin
g
g
union conn
t
o seal threa
ly cleaned
b
omponents
ng with one
g at the end
p
suction an
st this stop.
d
then use a
e
d considera
o
r, clean off
o
o
r. Use 1 ½”
sure to inst
a
b
ing connec
t
d
adapters.
A
lastic pipe s
e
fitting into
w
rench, tight
r
y. (NOTE:
A
e
s and ove
r
-
t
s
e damage t
o
m
mended w
h
t
he pool suc
and the pu
m
g
to the OUT
L
y.
r
ain or plug i
l
that is nee
d
A manual
a
e
bleeding o
f
n
g the filter.
peration
t
allation/Se
i
n valve at th
e
d lock Easy-L
o
A
RNING CO
M
ilure to prop
e
prevent co
m
r
elief valve (T
u
v
es (Optional
s
W
ARNING C
O
a
ilure to ope
n
e
vere person
u
ction and o
u
d
start the pu
m
h
as escaped t
h
note the pre
s
USE ON
L
g
of the filter
ections at t
h
ded connec
t
b
efore use.
N
. When app
to two layer
s
of the fittin
g
d outlet por
t
It is only n
e
tool to enga
bly; do NOT
o
ld
T
FE tape,
I.D. flexible
a
ll Hayward
S
t
ions on the
X
A
pply three
(
ealant to th
e
the thread
h
en one mor
e
dapters hav
e
t
ightening w
i
o
the filter.)
h
ere needed
.
tion plumbi
n
m
p. Connect
L
ET port at t
h
s furnished
w
d
ed for com
p
a
ir relief valv
e
f
unwanted
a
asonal Star
e
base of filte
r
o
k™ ring.
M
PONENT S
e
rly secure t
h
m
ponent sep
a
u
rn lever to le
f
s
uction & ret
u
O
MPONENT
S
n
all suction
al injury and
u
tlet valves
b
m
p per manuf
a
h
e filter and
a
s
sure gauge r
e
L
Y HAYWARD
G
system and
h
e suction a
n
t
ions on mol
d
N
OTE: Do N
O
lying TFE ta
p
s
of tape. W
i
g
.
t
s have mol
d
e
cessary to t
i
g
e fitting an
over-tighte
rewrap wit
h
plastic pipe
S
P1500UNP
A
X
Stream™
F
(
3) turns of
T
e
male threa
d
h
and-tight; t
h
e
full turn, if
e
varying
i
th a wrench
Ball type va
l
.
n
g between
t
the pool ret
h
e bottom o
f
w
ith each fil
t
p
lete filter
e
is furnishe
a
ir when sta
r
t-Up
r
.
EPARATION
h
e filter head
a
ration alway
f
t).
u
rn valves).
S
EPARATIO
N
and outlet v
a
/or property
b
efore opera
t
a
cturer’s inst
r
a
steady strea
m
e
ading.
G
ENUINE REP
to allow for
i
n
d outlet po
r
d
ed plastic
c
O
T use Plum
p
e to plastic
i
nd the tape
d
ed-in threa
d
i
ghten fittin
g
additional 1
n fitting or y
o
h
one to two
a
with hose a
d
A
K2 union c
o
F
ilter are 1 ½
T
FE
d
s.
h
en
may
l
ves
t
he
urn
f
the
t
er
d to
r
ting
HAZARD
could caus
e
s turn Easy-
L
N
HAZARD
a
lves before
damage. To
t
ing the filter
r
uctions.
m
of water is
f
LACEMENT P
A
indoor stora
r
ts is recom
m
c
omponents
ber’s Pipe
D
threads, wr
a
clockwise a
d
stops. Do
N
g
s enough t
o
½ turns. U
s
ou may cau
s
a
dditional l
a
dapter fittin
g
o
nnectors fo
r
” N.P.T. Wh
e
e
severe pers
o
L
ok ring until
operating th
e
prevent com
r
system.
f
lowing from
t
A
RTS
ge during th
m
ended.
. All plastic
D
ope as it
m
a
p the entir
e
s you face t
h
N
OT attempt
o
prevent lea
s
e care whe
n
s
e damage.
a
yers of Tefl
o
g
s and hose
r
easy servic
e
n making c
o
onal injury a
n
it is fully lat
c
e
filter syste
m
m
ponent sep
a
t
he air relief
v
e winter mo
n
fittings mus
t
m
ay cause c
r
e
threaded p
o
h
e open end
to force ho
s
kage. Tight
e
n
using
T
FE t
a
If leaks occ
u
o
n tape, and
clamps. If r
ing.
o
nnections,
nd/or prope
r
c
hed into bo
d
m
could cau
s
a
ration open
a
v
alve, close th
n
ths,
t
be new or
r
acking of t
h
o
rtion of the
of the fittin
g
s
e connector
e
n fitting by
a
pe as fricti
o
u
r, remove
re-install
igid PVC is
use plastic
r
ty damage.
d
y.
s
e
a
ll
e air relief
5
h
e
g
,
o
n
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS 6
Filter Disassembly & Assembly
Cleaning/Removing Cartridge Element
NOTICE: An indication that the filter needs cleaning is when the pressure gauge rises 5-7 PSI above its
normal pressure.
1. Shut off the pump.
2. Close valves* (*optional: suction & return valves).
3. Open air relief valve.
4. Open drain plug (located at the base of the filter body).
5. Depress safety latches (located on the underside of the locking ring handles) and unscrew locking ring in a
counter-clockwise direction. Remove lid from filter body.
6. Lift out filter element and clean as instructed in “Preventative Maintenance” section of this manual.
Re-Installing Cartridge Element
1. Clean debris from bottom of filter tank.
2. Replace element evenly on the collector hub in bottom of the filter body.
3. Place lid evenly on filter body and turn Easy-Lok™ ring clockwise until the safety latches engage securely.
4. Close and secure drain plug (located at the base of filter body).
5. Proceed as in “Start-Up & Operation”
Preventative Maintenance
Cleaning Cartridge Filter
NOTICE: Clean the cartridge when filter canister pressure reaches 5-7 PSI above the initial system or new cartridge
starting pressure.
1. Remove the cartridge element from the filter housing following the directions in the “Cleaning/Removing Cartridge
Element” section above.
2. DO NOT Pressure wash. Wash the cartridge element inside and out with the Hayward Jet-action Cleaning Wand
(EC2024) or a garden hose. Work from top-down, holding the nozzle at a 45-degree angle. All dirt and debris may
not be removed with hosing. Brush pleated surface areas and allow to dry.
Vacuuming
Vacuuming can be performed directly into the filter whenever needed. For fastest results, clean the filter before and
after each vacuuming. For heavy spring clean ups, we recommend using a Hayward SP0727 diverter valve to bypass
the filter and accelerate the clean up process. Consult your local Hayward dealer for a detailed explanation.
Winterization
In areas where sub-freezing temperatures can be expected, the filter should be drained and/or removed from its
operating location and stored indoors. Clean the cartridge element at the end of the pool season by using the
Hayward Jet-action Cleaning Wand (EC2024) or a garden hose. (See “Cleaning Cartridge Filter” instructions in this
manual).
TROUBLE SHOOTING
Problem What to Look For Treatment
Dirty, clogged, or abused
element
Dirt, debris, or tear in pleats or folds What to
Look for
Clean or replace element
Oversized pump - Produces
excessive flow rates and/or
pressures
Flattened pleats or folds; Embedded dirt or debris into
the filter material; Breaking of internal core of the
element; Breaking or splitting of the end plates of the
element
Re-size pump
Very dirty pool water Algae buildup on the pool walls
Frequent cartridge cleaning or
replacement; Consult professional
pool company for pool chemistry
instructions.
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS 7
REPLACEMENT PARTS
REF
NO Part No. Description No.
Req
1 ECX27091 Pressure Gauge 1
2 CCX1000l Threaded Adaptor 1
3 CCX1000V Air Relief Assy 1
4 CCX1000D Lock Ring Assy 1
5 CCX1000H Lock Ring Latch 2
6a CCX1000C 100 Filter Lid w/ Lock
Ring
1
6b CCX1500C 150 Filter Lid w/ Lock
Ring
1
7 CCX1000N Adapter Nut 2
8a CCX1000RE Cartridge Element 1
8b CCX1500RE Cartridge Element 1
9 CCX1000B Filter, Lower Body 1
10 SP1480BLK Self Aligning Union
(Black)
1
11 Pump 1
12 CCX1000A Base, Standard 1
13 SP1022CBLK Drain Plug
w/O-ring
1
14 CCX1000G O-ring, Body 1
15 SPX1500W O-ring 1
16 CCX1000Z5 O-Ring set 1
17 SP1500UNP
AK1
Union Connector
(Optional)
1
18 SP1484 Self-Aligning Union,
(Optional)
1
0
2
4
6
8
10
12
14
16
18
20
0 20 40 60 80 100 120 140
Head Loss in Ft of Water
Flow Rate in GPM
Head Loss on XStream Filters
CC1500
CC1000
-----
X
S
Ple
a
Firs
t
Str
e
Cit
y
Pho
E-M
Ser
i
Mo
d
Poo
If y
o
nec
e
Inst
e
seri
a
Ple
Mai
Att
n
Or
R
To
pe
r
Th
e
be
c
un
f
Pr
o
so
l
To
Ha
y
Ha
y
or
r
Th
e
re
s
Th
e
wa
re
s
So
li
m
DATE O
F
Hayward is a re
g
© 2014 Haywa
r
d
DETACH
---------------------
S
tream
a
se Print Clea
r
t
Name____
_
e
et Address_
_
y
__________
_
ne Number_
_
ail Address_
_
i
al Number
d
el Number_
_
l Capacity__
_
o
ur product co
n
e
ssary to com
p
e
ad, complete
a
l number tha
t
ase include me
o
l to: Haywar
d
n
: Warranty D
e
R
EGISTER YOU
original purchas
e
r
iod of ONE (1) y
e
e
limited warrant
c
ome defective
d
f
oreseen delays,
o
of of purchase i
s
l
e determination
obtain warranty
s
y
ward Authorize
d
y
ward shall not
b
repair.
e
Hayward Pool
p
s
pective manufa
c
e
express limite
d
rranties express
e
s
ponsible for any
me states do not
m
itation may not
a
*Superse
Hayward is
© 2015 Ha
y
F
INSTALLA
T
Retain this W
a
g
istered trademark o
f
d
Industries, Inc.
HERE: Fill out
b
---------------------
Cartrid
g
r
ly:
_
__________
_
_
_________
_
_
__________
_
_
_________
_
_
_________
_
___________
_
_
__________
_
n
tains compo
n
p
lete warranty
warranty regi
s
t
is located on
o
n all e-mail com
m
d
Pool Produc
t
e
pt
R WARRANTY
e
rs of this equip
m
e
ar from the date
y
excludes dama
d
uring the warran
without charge.
s
required for wa
r
of the purchase
d
s
ervice, please c
o
d
Service Center
p
b
e responsible fo
p
roducts warrant
y
c
turer will apply.
warranty above
e
d or implied, in
c
consequential,
s
allow a limitatio
a
pply to you. Thi
s
des all previous
a registered tradem
a
y
wa
r
d Industries, Inc
.
USE ON
L
T
ION __
_
a
rranty Certific
f
Hayward Industries
b
ottom portion c
---------------------
-
g
e Filter
R
_
____ Last N
a
_
__________
_
_
_______ St
a
_
_________ P
_
__________
_
_
__________
_
_
(U.S. Gallon
s
n
ents that hav
e
registration f
o
s
tration only f
o
the outside o
f
m
unications reg
a
t
s, 620 Divisi
o
ON-LINE AT
W
HAYWAR
D
m
ent, Hayward P
o
of purchase, wh
e
ge from freezing
,
ty period shall b
e
r
ranty service. In
d
ate.
o
ntact the place
p
lease visit us at
r cartage, remov
a
y
does not apply
t
constitutes the
e
c
luding warrantie
s
pecial or incide
n
n on how long a
n
s
warranty gives
y
publications.
a
rk and XStream is a
t
.
L
Y HAYWARD
G
PRODUC
T
(Retain
_
________
_
ate (upper po
r
, Inc.
ompletely and
m
-
--------------------
-
R
egister onli
n
a
me_______
_
_
__________
_
a
te________
_
urchase Dat
e
_
__________
_
_
__________
_
s
)
e
individual s
e
o
r those indivi
d
o
r the overall
p
f
the product
p
a
rding Hayward®
o
n Street, Eliz
a
W
WW.HAYWA
R
D
®
Pool P
o
ol Products, Inc
.
e
n used in single
,
negligence, im
p
e
repaired or repl
the event proof
o
o
f purchase or t
h
www.hayward.
c
a
l, repair or insta
t
o components
m
ntire warranty of
s of merchantab
i
n
tal damages of
a
n
implied warran
t
y
ou specific lega
t
rademark of Haywa
r
G
ENUINE REP
L
T
REGISTR
A
For Your Recor
d
_
________
r
tion) in a saf
e
m
ail within 10 d
a
-
--------------------
-
n
e at www.h
a
_
__________
_
_
_________
_
_
__ Zip_____
_
e
__________
_
_
_________
_
_
__________
_
e
rial numbers,
d
ual compone
p
roduct, usin
g
p
ackaging.
Equipment or pr
o
a
beth, NJ 07
2
R
D.COM
roducts
L
.
warrants its pro
family residenti
a
p
roper installatio
n
aced, at our opti
o
o
f purchase is n
o
h
e nearest Haywa
c
om.
llation labor or a
m
anufactured by
o
Hayward Pool P
r
i
lity or fitness fo
r
a
ny nature.
t
y lasts, or the ex
c
l rights, and you
r
d Industries, Inc.
L
ACEMENT P
A
A
TION
d
s)
e
and conveni
e
a
ys of purchase
/
-
--------------------
-
W
a
a
yward.com
Y
ea
r
<
1
Pur
c
B
u
Co
m
Add
City
_
Pho
Typ
e
C
o
O
N
Inst
a
I
n
_______
_
______
_
______
_
______
_
______
_
______
it is not
nts.
g
the
o
motions.
2
07
L
imited W
ducts to be free
f
a
l applications.
n
, improper use
o
on, within 90 da
y
o
t available, the
m
a
rd Authorized S
e
ny other such co
s
o
thers. For such
r
oducts with resp
r
a particular pur
p
clusion of incide
may also have o
t
A
RTS
e
nt location fo
/
installation or
r
-
-------------
a
rranty
C
r
s Pool has been
1
year 1-3
c
hased from____
_
u
ilder Retailer
m
pany Name____
_
ress__________
_
_
_____________
_
ne___________
_
e
of Pool:
o
ncrete/Gunite
ther__________
_
ew Installation
a
llation for:
n
Ground A
b
W
arranty
f
rom defects in
m
o
r care or any Ac
t
y
s of the receipt
o
m
anufacturing d
a
e
rvice Center. Fo
r
s
ts incurred in o
b
products, the w
a
p
ect to its’ pool p
r
p
ose. In no event
ntal or conseque
t
her rights, whic
h
r your records
.
r
egister online.
C
ard Reg
in service
4-5 6-10
_
_____________
_
Pool Service
_
_____________
_
_
_____________
_
_
_____ State___
_
_
_____________
_
Vinyl Fi
b
_
_____________
_
Re
p
b
ove Ground
m
aterials and wo
r
t
s of God. Parts t
h
o
f defective prod
a
te of the produc
t
r
assistance on y
o
b
taining warrant
y
a
rranty establish
e
r
oducts and is in
t
shall Hayward P
e
ntial damages, s
h
vary from state
Hayw
a
6
2
Eli
z
.
istratio
n
11-15 >15
_
__________
Internet/Catalo
g
_
_____________
_
_
_____________
_
_
_ Zip_________
_
_
_____________
_
b
erglass
_
____
p
lacement
Spa
r
kmanship for a
h
at fail or
uct, barring
t
will be the
o
ur nearest
y
replacements
e
d by the
lieu of all other
ool products be
s
o the above
to state.
a
rd Pool Products
2
0 Division Street
z
abeth, NJ 07207
8
n
g
_
_
_
_
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

Hayward XStream CC1000 Owner's manual

Category
Above ground pool accessories
Type
Owner's manual

Hayward XStream CC1000 is a powerful and versatile pool pump, designed to keep your pool water clean and refreshing. With its advanced hydraulic design, the CC1000 delivers exceptional flow rates and energy efficiency, ensuring that your pool water is always crystal clear. The pump is also equipped with a self-priming feature, making it easy to start up and operate, even after extended periods of inactivity. Additionally, the CC1000 is built with durable materials and features a corrosion-resistant finish, ensuring long-lasting performance and reliability.

Ask a question and I''ll find the answer in the document