Manual resca
n
When a ser ver configured with MultiPulse first boots, MultiPulse automatically recognizes up to four
physical paths and associates them with the sam e virtual device. However, after the initial configuration,
MultiPulse does not recognize a new physical path that comes online to an already configured LUN.
To enable MultiPulse to recognize the new physical path, you must per form a manual rescan using
the hp_rescan utility.
To manually
rescan:
1. Ensure that the fibreutils RPM is installed on your system.
2. Enter the following comma nd:
hp_rescan –
a
New default per LUN queue depth
For new installations, the default per LUN queue depth for Emulex HBAs on Linux systems h as been
changed to 16. Note that this affects new installations only, and does not affect upgrades. For upgrades,
the current setting for queue de pth is retained.
Restrictions
This section d escribes MultiPulse restrictions.
• MultiPul
se does not support older firmware on HP storage arrays. These storage arrays are
known as
active-passive storage arrays since not all paths are active on the fabric at the same
time. These arrays include:
• MSA1000 and MSA1500 running 4.x or 5.x firmware
•EVA3000
and EVA5000 running VCS 3.x
• If using MultiPulse 2.1.x, you can have a maximum of four physical paths to a LUN. More than
four paths can cause improper failure.
• If using MultiPulse 2.2.x, you can have a maximum of eight physical paths to a LUN. More
than eight paths can cause improper failure.
• Multi
Pulse can coexist with multipathing products such as QLogic
®
failover driver, Secure Path, or
Device Mapper. However, note that MultiPulse only works with Emulex-based H BAs; it will not
configure multiple paths for other HBAs in the system.
• When u
sing MultiPulse with SUSE Linux systems in Boot from SA N configurations, HP recommends
that
you use the Udev utility to ensure that your system successfully boots. For detailed information
about this procedure, see "Using the Udev utilit y with SUSE Linux systems" in the B ooting
Itanium Linux systems from a storage area network application notes, available on the website
h
ttp://h18006.www1.hp.com/storage/saninfrastructure.ht ml.
• XP LUN s presented to Linux hosts must start with LUN 0.
• HP r
ecommends that you implement zoning with HBA, as described in the HP StorageWorks SAN
de
sign reference guide, available on the websiteh
ttp://h18006.www1.hp.com/products/
st
orageworks/san/documentation.html
• HBAnyware:
• Emulex HBAs may not appear in HBAnyware due to a conflict between library entries in
/
etc/hba.conf. After installing HBAnyware, run the following script from the HP driver
kit to correct the problem:
/opt/hp/hp-lpfc/remove_lpfc_hbaconf_entry.sh
MultiPulse failover driver for Linux application notes
7