NOTE: Push coupler back until it
clicks to prevent air from escaping
through the quick connect.
2. Plug the power cord into the
correct branch circuit receptacle.
(Refer to Voltage and Circuit
Protection paragraph in the
Installation section of this
manual.)
3. Open the drain valve (counter-
clockwise) fully to permit air to
escape and prevent air pressure
build up in the air tank during the
break-in period.
_Risk from Flying
-- Objects. Always
wear certified safety equipment:
ANSI Z87.1 eye protection (CAN/
CSA Z94.3) with side shields as
debris can be kicked up into face.
4. Move the Auto/Off switch to
"Auto" position. The compressor
will start.
5. Run the compressor for 15
minutes. Make sure the drain
valve is open and there is
minimal air pressure build-up in
tank.
6. After 15 minutes, close the drain
valve by turning clockwise. The
air receiver will fill to "cut-out"
pressure and the motor will
stop.
The compressor is now ready for use.
Before Each Start-Up
1. Place Auto/Off switch to "Off".
2. Pull regulator knob out, turn
counter-clockwise until it stops.
Push knob in to lock in place.
3. Attach hose and accessories.
NOTE: The hose or accessory will
require a quick connect plug if the
air outlet is equipped with a quick
connect.
Risk of unsafe
operation, Firmly
grasp air hose in hand when
installing or disconnecting to
prevent hose whip.
Risk of unsafe
operation, Do not
use damaged or worn accessories.
Too much air
pressure causes a
hazardous risk of bursting. Check
the manufacturer's maximum
pressure rating for air tools and
accessories. The regulator outlet
pressure must never exceed the
maximum pressure rating.
Risk of unsafe
operation.
Compressed air from the unit may
contain water condensation and
oil mist. Do not spray unfiltered air
at an item that could be damaged
by moisture. Some air tools and
accessories may require filtered air.
Read the instructions for the air tools
and accessories.
How to Start
1. Turn the Auto/Off switch to
"On/Auto" and allow tank pres-
sure to build. Motor will stop
when tank pressure reaches "cut-
out" pressure.
2. Pull the regulator knob out and
turn clockwise to increase
pressure. When the desired
pressure is reached push knob in
to lock in place. The compressor
is ready for use.
Risk of fire or
' °-_--explosion, AIways
operate the air compressor in well-
ventilated areas free of gasoline or
other combustible vapors. If the
compressor is being used to operate a
sprayer DO NOT place near the spray
area.
_lf any unusual
__ noise or vibration
is noticed, stop the compressor
immediately and have it checked by
a trained service technician.
The compressor is ready for use.