Honeywell HCM-5300E Operating instructions

Category
Humidifiers
Type
Operating instructions
ULTRASONIC HUMIDIFIER
USER INSTRUCTIONS
GB
ULTRASCHALL-LUFTBEFEUCHTER
GEBRAUCHSANWEISUNG
DE
HUMIDIFICATEUR D’AIR À ULTRASONS
MANUEL D’UTILISATION
FR
ULTRASONE LUCHTBEVOCHTIGER
BEDIENINGSHANDLEIDING
NL
HUMIDIFICADOR ULTRASÓNICO
MANUAL DEL USUARIO
ES
UMIDIFICATORE AD ULTRASUONI
ISTRUZIONI D'USO
IT
HUMIDIFICADOR ULTRA-SÓNICO
MANUAL DO UTILIZADOR
PT
ULTRALJUDSLUFTFUKTARE
ANVÄNDARINSTRUKTIONER
SE
ULTRALYDS-LUFTFUKTER
BRUKERVEILEDNING
NO
ULTRALYDLUFTBEFUGTER
BRUGSVEJLEDNING
DK
ULTRAÄÄNI-ILMANKOSTUTIN
KÄYTTÖOHJEKIRJA
FI
ULTRADŹWIĘKOWY NAWILŻACZ POWIETRZA
INSTRUKCJA OBSŁUGI
PL
ULTRASON‹K HAVA NEMLEND‹R‹C‹S‹
KULLANIM TAL‹MATLARI
TR
ULTRAHANGOS PÁROLOGTA
HASZNÁLATÍ ÚTMUTA
HU
ULTRASONIČNI OVLAŽIVAČ ZRAKA
UPUTE ZA UPORABU
HR
ULTRAZVUKOVÝ ZVLHČOVAČ VZDUCHU
VOD PRO U
Ž
IVATELE
CZ
NADZVOČNI VLAŽILNIK
NAVODILO ZA UPORABO
SI
УЛЬТРАЗВУКОВОЙ УВЛАЖНИТЕЛЬ ВОЗДУХА
ИНСТРУКЦИИ ПО ЭКСПЛУАТАЦИИ
RU
Ταλαντευµενς επιτραπέις ανεµιστήρας
∆ΗΓΙΕΣ ΡΗΣΗΣ
GR
SA
HCM-5300E
2
ENGLISH
5
GB
DEUTSCH
10
DE
FRANÇAIS
16
FR
NEDERLANDS
22
NL
ESPAŇOL
28
ES
ITALIANO
40
IT
PORTUGUÊS
34
PT
SVENSKA
46
SE
NORSK
52
NO
DANSK
56
DK
SUOMI
61
FI
POLSKI
66
PL
TÜRKÇE
73
TR
MAGYAR
83
HU
HRVATSKI
89
HR
ČESKY
77
CZ
SLOVENSKO
94
SI
РУССКИЙ
99
RU
ΛHNIKA
106
GR
113
SA
CONTENTS
INHALTSVERZEICHNIS
SOMMAIRE
INHOUDSOPGAVE
INDICE
INDICE
INDICE
INNEHÅLLSFÖRTECKNING
INNHOLTSFORTEGNELSE
INDHOLDSFORTEGNELSE
SISÄLLYSLUETTELO
SPIS TREŚCI
FIHRIST
TARTALOMJEGYZÉK
OBSAH
SADRŽAJ
VSEBINA
СОДЕРЖАНИЕ
ΠΕΡΙΕΜΕΝΑ
5
ENGLISH
IMPORTANT SAFETY INSTRUCTIONS
Read through all the instructions before operating
the humidier. Keep these instructions safely for
future use.
1. Keep out of reach of children.
2. Do not operate the humidier outdoors; do not
place in direct sunlight, high-temperature areas
or near computers or sensitive electronic
equipment.
3. The humidier must only be used to humidify
the room.Inappropriate use can lead to hazards
and damages for which no liability is assumed.
4. Place the humidier on a level, rm, non-metallic
and waterproof surface.Make sure it is in a
stable position, so that it cannot fall over or fall
down.Water can damage furniture and oors.
5. Unravel the cord before use.Failure to do so
could cause overheating and possible re hazard.
6. Do not use an extension cord or a solid-state
speed-control device. Doing so could cause
overheating, re hazard or electric shock.
7. Only connect the humidier to a single-phase AC
supply to the voltage shown on the rating plate.
8. Always disconnect the cord at the wall plug
before removing the unit, lling, touching, moving
or cleaning or when it not in use.Do not tug at
when disconnecting it. Do not touch the
power cable with wet hands.
9. Do not add any substances into the water
(e.g.inhalant, aromatic substances etc.).This
can cause health hazards to humans.
10. Do not touch the Ultrasonic Nebulizer (17) when
the humidier is operating.Doing so could
cause burns.
11. Do not direct the mist outlet (4) directly at
people, walls or any objects.
12. Do not remove the lled Water Tank (3) when
the humidier is in operation.Do not operate
the humidier without water or when the Water
Tank (3) is empty. Doing so could damage the
humidier.
13. Do not operate the humidier without the
demineralization cartridge (13) and do not use
an exhausted cartridge. In areas where the
water is very hard there might be an output
of minerals, noticeable as white dust.
14. Do not immerse the humidier in water or
other liquids and do not pour water or other
liquids over the humidier or into the Mist
Outlet (4) or Air Inlet (21).
15. Ventilate the room regularly.When a humidier
is used in closed or small rooms, excessive
humidity can condense on furniture, walls and
oors.It is also possible to reduce the output
with the Intensity Control (5) and with the
Humidistat (6).
16. Clean the humidier regularly following the
Cleaning Instructions.
17. If the Power cable (20) is damaged, it must be
replaced by the manufacturer, a service agent
or an authorized person to avoid any risk.
18. Do not operate the humidier if it is damaged,
faulty or is not working properly. Disconnect it
from the electricity supply.
PARTS IDENTIFICATION
1
Directional Mist Nozzle
2 Carrying Handle
3 Water Tank 7.7 litres
4 Mist Outlet
5 Power Switch and Intensity Control
6 Humidistat Switch and Humidity Control
7 Power Indicator Light
8 Humidity Indicator Light
9 Tank Cap
10 Tank Water Valve
11 Base
12 Water Tray
13 Demineralization Cartridge AC-819E
14 Cartridge Water Valve
15 Reservoir
16 Water Sensor
17 Ultrasonic Nebulizer
18 Ultrasonic Nebulizer Cover
19 Automatic Shut-Off Function
20 Power cable and Plug
21 Air Inlet
Accessories*
22 Test strips for water hardness
23 Cleaning brush
24 Disinfectant Dimanin A
*These accessories can be purchased.
6
ENGLISH
FIRST TIME OF USE
1.
Read through all the instructions before using
the humidier.
2. Unpack the humidier, the Power cable (20),
the Water Tank (3), the Directional Mist Nozzle
(1), the Base (11) and the Demineralization
Cartridge (13); remove all packaging material
and discard.Packaging material can be recycled.
3. Place the humidier on a level, rm, non-metallic
and waterproof surface.Make sure it is in a
stable position, so that it cannot fall over or fall
down.Water can damage furniture and oors.
A safety distance of at least 1.20 m from any
objects must be kept.
4. Soak the Demineralization Cartridge (13) in
cool tap water for two hours prior to use in
order to achieve best lter results.
5. Check your water hardness.
DEMINERALIZATION
CARTRIDGE AC-819E
1.
The durability and performance of the AC-819E
Cartridge (13) depends on the mineral content
of the water.It can be used for a water hardness of
up to 15°dH.Its lifetime for 0-10°dH is approx.ve
months and for 10-15° dH approx.three months.
Ask your local water supplier for information
about the water hardness in your area.
2. When using the humidier under normal
conditions the Cartridge (13) should be repla-
ced every three to ve months at the latest.
3. If the humidier has not been used for a longer
period of time (e.g. over the summer season),
the Cartridge (13) must be replaced by a new
one.Soak the Demineralization Cartridge (13)
in cool tap water for two hours prior to use in
order to achieve the best lter results.
4. Replacement AC-819E Cartridges (13) are
available where you purchased your humidier.
5. Do not operate the humidier without the
Demineralization Cartridge (13) and do not
use an exhausted Cartridge. In areas, where
water is very hard, there might be an output
of minerals, noticeable as white dust
(see extra lters).
EXTRA FILTERS
In areas where the water is very hard there might
be an output of minerals, noticeable as white dust.
In order to determine the hardness of the water you
may ask your local waterworks.
KF-520E K-Filter
1.
If the water is extremely hard the cold tap water
should be ltered with the KF-520E K-Filter
before lling it into the Water Tank (3).
2. The KF-520E K-Filter reduces the calcium
carbonate content of the water.
3. The KF-520E K-Filter can be regenerated and
therefore has a long lifetime.
4. For using the KF-520E K-Filter, please read
and follow carefully the special instructions
included in each lter package.
SF-530E A-Filter
1.
The SF-530E A-Filter should be used when salt
is added to the water by use of a water softening
plant. If the water has an extremely high salt
content the cold tap water should rst be ltered
with the SF-530E lter.
2. Then lter the water with the KF-520E K-Filter.
The water, ltered twice, can now be lled into
the Water Tank (3).
3. The SF-530E A-Filter can be regenerated and
therefore has a long lifetime.
4. For using the SF-530E A-Filter, please read
and follow carefully the special instructions
included in each lter package.
FILLING THE WATER TANK
1.
Check that the Power Switch (5) is in the Off
position and that the plug is not in the socket.
2. Remove the Directional Mist Nozzle (1) from
the Water Tank (3).
3. Remove the Water Tank (3) from the Base (11)
and turn it upside down. Open the Tank Cap
(9) by turning it counter-clockwise.
4. Fill the Water Tank (3) only with clean, cool
tap water (approx. 7,7 litres). Do not use warm
or hot water.This can damage the Cartridge
(13) and the Ultrasonic Nebulizer (17) and
void the warranty.
5. Do not add any substances into the Water
Tank (3), the Reservoir (15) or onto the
Cartridge (13) (e.g. inhalant, aromatic sub-
stances etc.). This can cause health hazards
to people.
6. Close the Water Tank (3) with the Tank Cap (9)
by turning it clockwise.
7. Make sure the Demineralization Cartridge (13)
is properly located and secured in the reservoir
(15) with the water tray (12) located on top.
7
ENGLISH
Place the water tray (12) carefully onto the
Cartridge Water Valve (14) and press down
until it sits properly on the Cartridge (13).
8. Turn the Water Tank (3) upright.Make sure that
the Tank Cap (9) is in place and check it for leaks.
9. Replace the lled Water Tank (3) on the Base
(11) and the Directional Mist Nozzle (1) into
the Water Tank (3).Wait for approx. 15 minutes
before operating the humidier, so that the
water can run through the Cartridge (13).
EXPLANATION OF THE
CONTROL PANEL
1. Humidistat (6)
for continuous adjustment of the desired humidity.The
optimum value between 40 % and 60 % is additionally
marked in blue.Once the humidity level exceeds the
set level, the unit will turn off and the blue humidity
indicator light (8) will illuminate.Once the humidity falls
below the set level, the unit will turn back on and the
humidity indicator light (8) will turn off.
2. Intensity Regulator (5)
for the precision regulation of the emission of mist
marked by blue drops.The associated Power Indicator
Light (7) will glow green when the unit is powered on.
OPERATING INSTRUCTIONS
1.
Check that the Water Tank (3) is lled and that
the Cartridge (13) and the Ultrasonic Nebulizer
Cover (18) are in place.
2. Check that the Power Switch (5) is in the Off-
position.Plug the power cable into the outlet.Do
not touch the power cable with wet hands.
3. Turn the Power Switch (5) to the desired output
level.The green Power Indicator Light (7) will
illuminate.Turn the Power Switch (5) clockwise
to increase mist output;turn it counter-clockwise
to decrease mist output.
4. Use the Humidistat Switch (6) to select the desired
humidity level.To increase humidity turn the
switch clockwise.When the desired humidity
level is reached, the humidier will shut off and
the blue humidity light (8) will illuminate.The
humidistat will automatically turn the humidier
back on and off again to maintain the humidity
level, with the humidity light (8) indicating
accordingly.
5. Direct the Mist Nozzle (1) away from people,
objects or walls.
6. If surplus humidity condenses on furniture,
walls or oors in closed or small rooms, turn
the Power Switch (5) counter-clockwise to
decrease mist output and open the door to the
room. If this does not solve the problem turn
the Power Switch (5) to the Off-position and
unplug the humidier.
7. Before removing the humidier or lling the
Water Tank (3) turn the Power Switch (5) to
the Off-position and unplug the humidier.
CLEANING, CARE AND STORAGE
We recommend cleaning the humidifier frequently.
In order to not impair the performance of the humi-
difier, follow the instructions for Cleaning,Care
and Storage.
Daily Cleaning
1.
Before cleaning, turn the Power Switch (5) to
the Off-position and unplug the unit.
2. Remove the Directional Mist Nozzle (1) from
the Water Tank (3) and remove the Water Tank
(3) from the Base (11).
3. Remove the Water Tray (12), the Ultrasonic
Nebulizer Cover (18) and the Cartridge (13)
from the Base (11). Do not wash or clean the
Cartridge (13).
4. Carefully wipe the end of the Water
Sensor (16) with white spirit to remove any
deposits that may have collected.Do not
attempt to remove or in any other way modify
the Water Sensor (16). Even touching it
can damage the delicate Sensor (16).
5. Empty excess water from the Base (11) only
via the side opposite to the Water Sensor
(16) and make sure that water does not enter
into the Air Inlet (21).
6. Open the Tank Cap (9) by turning it counter-
clockwise and drain any water from the Water
Tank (3).
7. Rinse the Water Tank (3) thoroughly with
lukewarm water.
8. Wipe the outer surfaces of the Water Tank (3)
with a clean, damp cloth.
9. To operate the humidier follow the instructions
under Filling the Water Tankand
Operating Instructions.
8
ENGLISH
Weekly Cleaning
1.
Follow the instructions under Daily Cleaning,
gures 1. to 6.
2. Clean the Water Tray (12), the Tank Cap (9) and
the Ultrasonic Nebulizer Cover (18) with a
commercially available washing liquid.To assist
the cleaning process, use a cleaning brush.
Afterwards thoroughly rinse these parts sever-
al times in lukewarm water.
3. Fill the Water Tank (3) approx.half-full with
lukewarm water.To assist the cleaning action
we recommend that you add approx. 10 drops
of Dimanin A*.Do not add soap or detergents.
Use a cleaning brush. Afterwards thoroughly
rinse the Water Tank (3) several times in luke-
warm water.Wipe the outer surfaces of the
Water Tank (3) with a clean, damp cloth.
*Dimanin A is a chlorine-free disinfectant that
is also used in swimming pools. It can be
purchased as an accessory.
Caution: Keep out
of reach of children. Do not swallow. Avoid
direct eye contact.In the recommended dilution it
is not harmful to skin or eyes.
4. Clean the inside of the Base (11) only with
lukewarm water.Do not touch the Water Sensor
(16) or the Ultrasonic Nebulizer (17).Make sure
that water does not enter into the Air Inlet (21).
Do not immerse the Base (11) in water.
5. To operate the humidier follow the instructions
under Filling the Water Tankand
Operating Instructions.
Disinfecting
1.
Every fortnight, after cleaning, you should
additionally disinfect these parts of the humidi-
er: Water Tank inside (3), Base inside
(11),Water Tray (12) and Ultrasonic
Nebulizer Cover (18).
2. Use a commercially available alcohol-based
disinfectant or high-proof alcohol.This disinfec-
tant is an alcohol mixture available at pharma-
cies and drug stores. Follow the disinfectant
manufacturers written instructions.Neither
substance will harm the plastic parts but
these should be rinsed thoroughly in water
after disinfecting.
3. Dry all inner surfaces with a soft tissue and
wipe all outer surfaces with a soft, dry cloth.
4. Every six weeks remove the Demineralization
Cartridge (13) from the Base (11). Put it briey
in hot, but not boiling water of approx.70 °C in
order to counteract any formation of germs.
5. To operate the humidier follow the instructions
under
Filling the Water Tankand
Operating Instructions.
Care and Storage
1.
Follow the Weekly Cleaninginstructions when
the humidier is not used for a longer period
(one week or more).
2. Let the humidier and all its parts dry completely.
3. Remove the Cartridge (13) from the Base (11)
and discard.
4. Do not store the humidier with a lled Water
Tank (3) nor with a used Cartridge (13).
5. Store the humidier in a cool, dry place.
ACCESSORIES
Test strips for checking the water hardness
1. To check your water hardness (total hardness)
you can make use of test strips (22), which can
be purchased as an accessory.
2. Dip a test strip (22) with all its test zones into a
glass lled with fresh tap water.Do not hold under
running water. After two minutes you can deter-
mine the degree of hardness of your tap water
according to the following table:
No. of test zones Total hardness
green violet
4 0 below 3° dH
31 4 7° dH
22 8 15° dH
1 3 16 22° dH
0 4 over 23° dH
Cleaning Brush and Disinfectant
To assist the cleaning action we recommend that
you use Dimanin A* (24) and the cleaning brush
(23), which can be purchased as accessories.
*Dimanin A is a chlorine-free disinfectant that is
also used in swimming pools.
Caution: Keep out of
reach of children. Do not swallow. Avoid direct eye
contact. In the recommended dilution it is not harm-
ful to skin or eyes.
9
ENGLISH
CONDITION OF SALE
As a condition of sale, the purchaser assumes
responsibility for the proper use and care of this
appliance in accordance with these printed instructions.
The purchaser or user must judge himself or herself
when to use the appliance and the length or use.
Our oral and written indications are based on
extensive tests. Our advice is given to the best of
our present knowledge, but without obligation
inasmuch as the use of the unit is beyond our direct
inuence.No liability can be assumed for any damages
caused by improper use (such as inadequate
cleaning, decalcifying lter exchanged too late, free
discharge of humidity impeded atomization of
chemical additives or liquids other than pure tap
water etc.).No additives must be put in the water
as the unit could suffer damage and health risks
could not be excluded as well.
NOTE: IF YOU EXPERIENCE A PROBLEM
WITH YOUR HUMIDIFIER PLEASE SEE
WARRANTY FOR INSTRUCTIONS. PLEASE
DO NOT ATTEMPT TO REPAIR THE HUMI-
DIFIER YOURSELF. DOING SO WILL VOID
THE WARRANTY AND COULD CAUSE
DAMAGE OR PERSONAL INJURY.
Technical specications are subject to change.
Solution
1.
Plug the humidier in.
2. Check the circuits and fuses
or ask a specialist.
1. Fill the Water Tank (3).
2. Place the humidier on a rm,
level surface.
3. Empty the water tank (3) and
rinse thoroughly with warm
water.
4. Carefully clean or disinfect
Water Sensor (16) and
Nebulizer (17).
5. Ensure water in Reservoir
(15) is adequate to immerse
Water Sensor (16).
6. Replace used Cartridge with
a new one (13).
7. Ask a specialist and follow
the instructions in the
warranty manual.
1. Follow the Operating
Instructions.
1. Follow the instructions under
Demineralization Cartridge
AC-819Eand use the extra
lter KF-520E.
2. Replace the exhausted Car-
tridge (13) with a new one.
Possible Cause
1.
The plug is not plugged in.
2. There is no power at the
outlet.
1. No water in Tank (3).
2. The unit is not placed on a
rm, level surface.
3. The Water Tank (3) was
washed with a washing liquid
and not rinsed thoroughly.
4. Mineral deposits on Water
Sensor (16) or Nebulizer (17).
5. Blower not operating (10).
6. Cartridge (13) is clogged.
7. Nebulizer not functioning.
1. The relative humidity in the
room is too high.
1. The water is too hard.
2. The Cartridge (13) is
exhausted.
Problem
The Power Switch is in the on-
position.The Pilot Light (7)
does not illuminate.
The humidier produces only litt-
le or no mist.
Humidity condenses on
furniture, walls or oors.
White dust
TROUBLE SHOOTING
The Honeywell trademark is used by Kaz, Inc.
under licence from Honeywell Intellectual Properties, Inc.
www.kaz.com / KAZ Hausgeräte GmbH,
Westerhaar 54, D-58739 Wickede, Phone: +49(0)23 77- 9 28 90
HCM-5300E-OM//0//2004-08-13
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108
  • Page 109 109
  • Page 110 110
  • Page 111 111
  • Page 112 112
  • Page 113 113
  • Page 114 114
  • Page 115 115
  • Page 116 116
  • Page 117 117
  • Page 118 118
  • Page 119 119
  • Page 120 120
  • Page 121 121

Honeywell HCM-5300E Operating instructions

Category
Humidifiers
Type
Operating instructions

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI