AirScape CVK-105, VK-450 Operating instructions

  • Hello! I am an AI chatbot trained to assist you with the AirScape CVK-105 Operating instructions. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Bathroom Ventilation Kit
Installation and Operation Manual
CVK-105/210/260/450 & VK-105/210/260/450
AirScape Bathroom Ventilation Kit Installation Manual, 06102015
©AirScape, Inc., 2015. All Rights Reserved.
Page 1
SAFETY INFORMATION
• Switch power to this unit off at the main circuit panel prior to its installation, service or
cleaning.
• Installationandwiringmustbedoneinaccordancewiththismanualandalllocalcodesandstandards.
• DoNOTinstallthisunit’sswitchwhereitcanbereachedfromatuborshower.
• Thisfanisforgeneralventilationonly.It has NOT been designed to exhaust particle-laden and/
or explosive mixtures of air, or for use in re-rated installations, and must NOT be used for
such.
INTRODUCTION
ThankyouforpurchasinganAirScape
®
BathroomVentilationKit.Thisunithasbeendesignedtoexhaust
airfromyourbathroom,quickly,quietlyandefciently,keepingthespacefreshandserene.Pleasetake
thetimetoreadthisentiremanualbeforeproceedingwithinstallation.
AirScape Bathroom Ventilation Kit Installation Manual, 06102015
©AirScape, Inc., 2015. All Rights Reserved.
Page 2
WHAT’S INCLUDED
Beforeproceedingfurther,takeaquickinventoryofeverythingincludedinthiskit.
Table 1: Kit Contents
Model # Fan
Plenum &
Damper
Grille Duct Y-Fitting
Roof Cap /
Wall Hood
Electronic
Timer
Cable
Ties
CVK-105
1qty
1qty,w/6”-
4”reducer
1qty 25ft.x4”
N/A
1qty,4” 1qty 4qty
CVK-210
1qty 1qty 1qty 25ft.x6”
N/A
1qty,6” 1qty 4qty
CVK-260
1qty 2qty 2qty 25ft.x6”
1qty,
6”x6”x6”
1qty,6” 1qty 8qty
CVK-450
1qty
2qty,w/8”-
6”reducer
2qty.
25ft.x6”;
25ft.x8”
1qty,
8”x6”x6”
1qty,8” 1qty 7qty
VK-105
1qty
1qty,w/6”-
4”reducer
1qty
N/A N/A N/A N/A N/A
VK-210
1qty 1qty 1qty
N/A N/A N/A N/A N/A
VK-260
1qty 2qty 2qty
N/A
1qty
6”x6”x6”
N/A N/A N/A
VK-450
1qty
2qtyw/8”-
6”reducer
2qty
N/A
1qty
8”x6”x6”
N/A N/A N/A
CHOOSING A LOCATION
Considerthefollowingwhenselectinglocationsforeachofthisunit’scomponents:
LocatingtheIntake(s)
• Positiontheintake(s)abovethesourcesofodorandmoisturetoexhaust.
• Toensureeffectiveairexchangeandcirculation,chooseapositionawayfromwindowsordoors.
• CVK/VK-260 & -450 ONLY:Theadditionalintake,grill,and
damperincudewiththesemodelsmakesitpossibletoventilate
onelargebathroomortwoadjacentbathroomssimultaneously,
asshowninFigure 1: Dual Intake Options at right.Forthe
latteroption,asecondtimer(soldseperately)isnecessary.
LocatingtheFan
• Choosealocationintheatticthatwillbeaccessibleforservice.
• Aminimumdistanceof8feetbetweenthefanandintake(s)is
recommendedforquietoperation.
• Thelongertheductrun,thequieterthefanwillbe.
• Considerthetotallengthofductprovidedinthekit,beingcarefulnottocomeupshort.
LocatingtheRoofCaporWallHood
• Apartfromaestheticconsiderations,selectalocationincloseenoughproximityforthelengthofduct
includedwithyourkit
Figure 1: Dual Intake Options
INSTALLATION
AirScapeBathroomVentilationKitsaredesignedforquickandeasyinstallation.Onceallofthexedcom-
ponentsaremounted,theyaresimpleconnectedusingtheprovidedex-ductandcableties.Straightfor-
wardwiringtotheincludedelectronicpush-buttontimercompletesthejob.
PlenumBoxInstallation
1. CVK/VK 105 ONLY:Attachthe6”-4”reducertothebackdraftdamper.
2. Checktheclearanceabovethedesiredintakelocation(s)tomakesurethereisroomfortheplenum
andductintheattic.
3. Cuta6”diametercircleoutoftheceilingsheetrock
inthedesiredintakelocation.
4. Placetheplenumboxovertheroughopening.
5. Anchortheplenumtoanatticjoistbydrivingat
least2robustself-tappingmetalscrews(NOTpro-
vided)throughtheplenumwallandintothestud.
Makesuretheweightoftheplenumissupported
bythejoist.Ifthedesiredintakelocationisnotad-
jacenttoajoist,useappropriatelysizedlumberto
frameacross-peicetowhichtoanchortheplenum.
Atright,Figure 2: Plenum & Framingshowshow
theplenumshouldbeattachedtotheframing.
6. Useahigh-qualitylatexcaulkattheroughopening
tomakeasealbetweenthesheetrockandplenum.
7. Attachthegrilletotheplenumfrombelow;adjust
thespringclipswithpliersasneededtoachievea
snugt.
8. CVK/VK 105 ONLY:Repeatthesestepstoattach
thesecondplenum.
FanInstallation
The fan can be mounted in any orientation.
1. Attachthemountingbrackettoframingmemberatappropriatelocation.
2. Attachthefantothemountingbracketusingtheprovidedsheetmetalscrews.
3. ElectricalConnection:Thefancanbepluggedintoanoutletintheatticusingthesupplied3-prong
powercord.Alternatively,thepowercordcanberemovedandthefanhardwireddirectlytothetimer
switch(seeFigure 3: Timer & Fan Wiring).Consultlocalcodesforwiringstandardsand/orcontact
anelectricianforfurtherassistancewithwiring.
FlexDuctInstallation
The individual components are joined together using insulated acoustic ex-duct.
Toattachtheducttoacollar:
1. Pullbacktheouterfoilandinsulationlayerstoexposetheblackpolylinewithspringcoil.
2. Pullthiscoillineoverthecollarandwrapitwithoneoftheprovidedcableties.
3. Pulltheinsulationandfoillayersoverthecollarandwrapthejointwithducttape(NOTprovided)to
makeanairtightseal.
AirScape Bathroom Ventilation Kit Installation Manual, 06102015
©AirScape, Inc., 2015. All Rights Reserved.
Page 3
Figure 2: Plenum & Framing
INSTALLATION,cont.
AirScape Bathroom Ventilation Kit Installation Manual, 06102015
©AirScape, Inc., 2015. All Rights Reserved.
Page 4
TimerInstallation
Theincludeddecora-styleelectronictimerinstallsintoastandardsingle-gangelectricalbox(notincluded).
Asecondtimer(soldseparately)canbewiredtoasinglefanfordual-bathventilation(seebelow).Besure
toshutoffpoweratthecircuitpanelpriortoanyelectricalwiring,andrefertolocalcodesforproperand
approvedmethods.Consultanelectricianifneeded.
1. Runwirefromthefan(oroutlet)intheattictothelocationinthewallwherethetimerwillbeinstalled.
2. Connectleadsusingapprovedmethods,followingtheproperwiringdiagramshownbelow.
NOTE: The following instructions apply ONLY to models CVK-105, -210, and -260:
RoofCap/WallHoodInstallation
*Use caution when walking on roofs and climbing ladders*
1. Atthedesiredlocation,cutthepropersizecircularholeintherooforwall.
2. Useproperandapprovedmethodstoattachtheroofcaporwallhoodandensurealeak-proofseal
aroundtheashing.If needed, consult a roong or siding professional.
Onceinstalled,operationofyourAirScapeBathVentilationKitisassimpleasapushofabutton.Gener-
ally,itisrecommendedtohaveabathfancontinuetorunfor20minutesaftertheconclusionofashower.
Withthe10/20/30/60minuteoperationoftheincludedelectronicpush-buttontimer,thiscanbeachieved
withconvenienceandease.
Sincethefanbearingsarepermanentlylubricatedandsealed,thereisnoperiodicmaintenancenecessary.
Figure 3: Timer & Fan Wiring
OPERATION & MAINTENANCE
SPECIFICATIONS & DIMENSIONS
Fan Specs & Dimensions
CFM “A” “B” “C”
(C)VK-105
105 4” 11” 8”
(C)VK-210
205 6” 12.625” 7.625”
(C)VK-260
260 6” 12.625” 7.625”
(C)VK-450
450 8” 14.75” 8.25”
AirScape Bathroom Ventilation Kit Installation Manual, 06102015
©AirScape, Inc., 2015. All Rights Reserved.
Page 5
Phone:866.448.8187(8:00am–5:00pmPST,M–F)
AirScape,Inc.
625CharlesWay
Medford,OR97501
CONTACT INFORMATION
Problem: Fan will not turn on.
Makesurepoweristurnedonatthebreaker.Checkwiringtofanandtimerswitch.Checkfantoensure
impellercanspinfreely.
Problem: Fan is noisy.
Determinelocationofnoisesource.Checkductforkinks.Checkductconnectionstoensureinnercoilis
notcollapsed.Iffanvibrationisthenoisesource,tryusingrubberizedwashersorgaskettodampenthe
noise,orhangthefanusingmetalstrappingandvibrationabsorbingmaterial.
Problem:Fanruns,butthereislittletonoairow.
Checkductforkinks.Checkbackdraftdamperdirection.Checkductconnectionstoensureinnercoilis
notcollapsed.Checkthatthefanimpellerisspinningfreely.
TROUBLESHOOTING
Plenum Box &
Backdraft Damper
Dimensions
WARRANTY
AirScape Bathroom Ventilation Kit Installation Manual, 06102015
©AirScape, Inc., 2015. All Rights Reserved.
Page 6
Hardware
AirScapewarrantstheoriginalenduser(“Customer”)thatnewAirScapefanproducts,includingallmoving
parts,motors,dampers,anddamperactuatorswillbefreefromdefectsinworkmanshipandmaterials,
undernormaluse,forthree(3)yearsfromtheoriginalpurchasedate.Electronictimersareexcludedand
arewarrantedbythemanufacturer.
Software
AirScapewarrantstoCustomerthattheAirScapefansoftwarewillperforminsubstantialconformanceto
itsprogramspecicationsforaperiodofthree(3)yearsfromthedateoftheoriginalpurchase.
Exclusions
Thiswarrantyexcludes(1)physicaldamagetothesurfaceoftheproduct,includingcracksorscratcheson
theoutsidecasing;(2)damagecausedbymisuse,neglect,improperinstallation,unauthorizedattempts
toopen,repair,ormodifytheproduct,oranyothercausebeyondtherangeofintendeduse;(3)damage,
causedbyaccident,re,powerchanges,otherhazard,oractsofGod;or(4)useoftheproductwithany
unauthorizeddeviceifsuchdevicecausestheproblem.
Exclusive Remedies
ShouldacovereddefectoccurduringthewarrantyperiodandCustomernotiesAirScape,Customer’s
soleandexclusiveremedywillbe,atAirScape’ssoleoptionandexpense,torepairorreplacetheproduct.
Replacementproductsorpartsmaybeneworreconditionedoracomparableversionofthedefective
item.AirScapewarrantsanyreplacedproductorpartforaperiodofninety(90)daysfromshipment,or
throughtheendoftheoriginalwarranty,whicheverislonger.
Obtaining Warranty Service
CustomermustcontactandreturnproducttoAirScape,ProductdealerorInstallerwithintheapplicable
warrantyperiodtoobtainwarrantyservice.Datedproofoforiginalpurchasewillberequired.AirScapewill
notberesponsibleforCustomer’smemorydatacontainedin,storedon,orintegratedwithanyproducts
returnedtoAirScapeforrepair,whetherunderwarrantyornot.
Warranty Exclusive
Theforgoingwarrantiesandremediesareexclusiveandinlieuofallotherwarranties,expressorimplied,
includingwarrantiesofmerchantability,tnessforaparticularpurpose,correspondencewithdescription,
andnon-infringement,allofwhichareexpresslydisclaimedbyAirScapeanditssuppliers.
Disclaimer
NeitherAirScapenoritssuppliersshallbeliableforincidental,consequential,indirect,special,orpunitive
damagesofanykind,ornanciallossarisingoutoforinconnectionwiththesaleoruseofthisproduct,
whetherbasedincontract,tort(includingnegligence)oranyothertheory,evenifAirScapehasbeenad-
visedofthepossibilityofsuchdamagesAirScape’sentireliabilityshallbelimitedtoreplacementorrepair
oftheproduct.
/