AirScape CVK-105 is a bathroom ventilation kit designed to exhaust air from your bathroom quickly, quietly, and efficiently, keeping the space fresh and serene. This unit is ideal for general ventilation and can be used in a variety of applications, including bathrooms, laundry rooms, and other small spaces. The CVK-105 features a powerful fan that can move up to 105 cubic feet of air per minute (CFM), making it ideal for even the largest bathrooms. The fan is also very quiet, operating at just 0.3 sones on the low setting and 1.0 sones on the high setting.

AirScape CVK-105 is a bathroom ventilation kit designed to exhaust air from your bathroom quickly, quietly, and efficiently, keeping the space fresh and serene. This unit is ideal for general ventilation and can be used in a variety of applications, including bathrooms, laundry rooms, and other small spaces. The CVK-105 features a powerful fan that can move up to 105 cubic feet of air per minute (CFM), making it ideal for even the largest bathrooms. The fan is also very quiet, operating at just 0.3 sones on the low setting and 1.0 sones on the high setting.

Bathroom Ventilation Kit
Installation and Operation Manual
CVK-105/210/260/450 & VK-105/210/260/450
AirScape Bathroom Ventilation Kit Installation Manual, 06102015
©AirScape, Inc., 2015. All Rights Reserved.
Page 1
SAFETY INFORMATION
• Switch power to this unit off at the main circuit panel prior to its installation, service or
cleaning.
• Installationandwiringmustbedoneinaccordancewiththismanualandalllocalcodesandstandards.
• DoNOTinstallthisunit’sswitchwhereitcanbereachedfromatuborshower.
• Thisfanisforgeneralventilationonly.It has NOT been designed to exhaust particle-laden and/
or explosive mixtures of air, or for use in re-rated installations, and must NOT be used for
such.
INTRODUCTION
ThankyouforpurchasinganAirScape
®
BathroomVentilationKit.Thisunithasbeendesignedtoexhaust
airfromyourbathroom,quickly,quietlyandefciently,keepingthespacefreshandserene.Pleasetake
thetimetoreadthisentiremanualbeforeproceedingwithinstallation.
AirScape Bathroom Ventilation Kit Installation Manual, 06102015
©AirScape, Inc., 2015. All Rights Reserved.
Page 2
WHAT’S INCLUDED
Beforeproceedingfurther,takeaquickinventoryofeverythingincludedinthiskit.
Table 1: Kit Contents
Model # Fan
Plenum &
Damper
Grille Duct Y-Fitting
Roof Cap /
Wall Hood
Electronic
Timer
Cable
Ties
CVK-105
1qty
1qty,w/6”-
4”reducer
1qty 25ft.x4”
N/A
1qty,4” 1qty 4qty
CVK-210
1qty 1qty 1qty 25ft.x6”
N/A
1qty,6” 1qty 4qty
CVK-260
1qty 2qty 2qty 25ft.x6”
1qty,
6”x6”x6”
1qty,6” 1qty 8qty
CVK-450
1qty
2qty,w/8”-
6”reducer
2qty.
25ft.x6”;
25ft.x8”
1qty,
8”x6”x6”
1qty,8” 1qty 7qty
VK-105
1qty
1qty,w/6”-
4”reducer
1qty
N/A N/A N/A N/A N/A
VK-210
1qty 1qty 1qty
N/A N/A N/A N/A N/A
VK-260
1qty 2qty 2qty
N/A
1qty
6”x6”x6”
N/A N/A N/A
VK-450
1qty
2qtyw/8”-
6”reducer
2qty
N/A
1qty
8”x6”x6”
N/A N/A N/A
CHOOSING A LOCATION
Considerthefollowingwhenselectinglocationsforeachofthisunit’scomponents:
LocatingtheIntake(s)
• Positiontheintake(s)abovethesourcesofodorandmoisturetoexhaust.
• Toensureeffectiveairexchangeandcirculation,chooseapositionawayfromwindowsordoors.
• CVK/VK-260 & -450 ONLY:Theadditionalintake,grill,and
damperincudewiththesemodelsmakesitpossibletoventilate
onelargebathroomortwoadjacentbathroomssimultaneously,
asshowninFigure 1: Dual Intake Options at right.Forthe
latteroption,asecondtimer(soldseperately)isnecessary.
LocatingtheFan
• Choosealocationintheatticthatwillbeaccessibleforservice.
• Aminimumdistanceof8feetbetweenthefanandintake(s)is
recommendedforquietoperation.
• Thelongertheductrun,thequieterthefanwillbe.
• Considerthetotallengthofductprovidedinthekit,beingcarefulnottocomeupshort.
LocatingtheRoofCaporWallHood
• Apartfromaestheticconsiderations,selectalocationincloseenoughproximityforthelengthofduct
includedwithyourkit
Figure 1: Dual Intake Options
INSTALLATION
AirScapeBathroomVentilationKitsaredesignedforquickandeasyinstallation.Onceallofthexedcom-
ponentsaremounted,theyaresimpleconnectedusingtheprovidedex-ductandcableties.Straightfor-
wardwiringtotheincludedelectronicpush-buttontimercompletesthejob.
PlenumBoxInstallation
1. CVK/VK 105 ONLY:Attachthe6”-4”reducertothebackdraftdamper.
2. Checktheclearanceabovethedesiredintakelocation(s)tomakesurethereisroomfortheplenum
andductintheattic.
3. Cuta6”diametercircleoutoftheceilingsheetrock
inthedesiredintakelocation.
4. Placetheplenumboxovertheroughopening.
5. Anchortheplenumtoanatticjoistbydrivingat
least2robustself-tappingmetalscrews(NOTpro-
vided)throughtheplenumwallandintothestud.
Makesuretheweightoftheplenumissupported
bythejoist.Ifthedesiredintakelocationisnotad-
jacenttoajoist,useappropriatelysizedlumberto
frameacross-peicetowhichtoanchortheplenum.
Atright,Figure 2: Plenum & Framingshowshow
theplenumshouldbeattachedtotheframing.
6. Useahigh-qualitylatexcaulkattheroughopening
tomakeasealbetweenthesheetrockandplenum.
7. Attachthegrilletotheplenumfrombelow;adjust
thespringclipswithpliersasneededtoachievea
snugt.
8. CVK/VK 105 ONLY:Repeatthesestepstoattach
thesecondplenum.
FanInstallation
The fan can be mounted in any orientation.
1. Attachthemountingbrackettoframingmemberatappropriatelocation.
2. Attachthefantothemountingbracketusingtheprovidedsheetmetalscrews.
3. ElectricalConnection:Thefancanbepluggedintoanoutletintheatticusingthesupplied3-prong
powercord.Alternatively,thepowercordcanberemovedandthefanhardwireddirectlytothetimer
switch(seeFigure 3: Timer & Fan Wiring).Consultlocalcodesforwiringstandardsand/orcontact
anelectricianforfurtherassistancewithwiring.
FlexDuctInstallation
The individual components are joined together using insulated acoustic ex-duct.
Toattachtheducttoacollar:
1. Pullbacktheouterfoilandinsulationlayerstoexposetheblackpolylinewithspringcoil.
2. Pullthiscoillineoverthecollarandwrapitwithoneoftheprovidedcableties.
3. Pulltheinsulationandfoillayersoverthecollarandwrapthejointwithducttape(NOTprovided)to
makeanairtightseal.
AirScape Bathroom Ventilation Kit Installation Manual, 06102015
©AirScape, Inc., 2015. All Rights Reserved.
Page 3
Figure 2: Plenum & Framing
INSTALLATION,cont.
AirScape Bathroom Ventilation Kit Installation Manual, 06102015
©AirScape, Inc., 2015. All Rights Reserved.
Page 4
TimerInstallation
Theincludeddecora-styleelectronictimerinstallsintoastandardsingle-gangelectricalbox(notincluded).
Asecondtimer(soldseparately)canbewiredtoasinglefanfordual-bathventilation(seebelow).Besure
toshutoffpoweratthecircuitpanelpriortoanyelectricalwiring,andrefertolocalcodesforproperand
approvedmethods.Consultanelectricianifneeded.
1. Runwirefromthefan(oroutlet)intheattictothelocationinthewallwherethetimerwillbeinstalled.
2. Connectleadsusingapprovedmethods,followingtheproperwiringdiagramshownbelow.
NOTE: The following instructions apply ONLY to models CVK-105, -210, and -260:
RoofCap/WallHoodInstallation
*Use caution when walking on roofs and climbing ladders*
1. Atthedesiredlocation,cutthepropersizecircularholeintherooforwall.
2. Useproperandapprovedmethodstoattachtheroofcaporwallhoodandensurealeak-proofseal
aroundtheashing.If needed, consult a roong or siding professional.
Onceinstalled,operationofyourAirScapeBathVentilationKitisassimpleasapushofabutton.Gener-
ally,itisrecommendedtohaveabathfancontinuetorunfor20minutesaftertheconclusionofashower.
Withthe10/20/30/60minuteoperationoftheincludedelectronicpush-buttontimer,thiscanbeachieved
withconvenienceandease.
Sincethefanbearingsarepermanentlylubricatedandsealed,thereisnoperiodicmaintenancenecessary.
Figure 3: Timer & Fan Wiring
OPERATION & MAINTENANCE
SPECIFICATIONS & DIMENSIONS
Fan Specs & Dimensions
CFM “A” “B” “C”
(C)VK-105
105 4” 11” 8”
(C)VK-210
205 6” 12.625” 7.625”
(C)VK-260
260 6” 12.625” 7.625”
(C)VK-450
450 8” 14.75” 8.25”
AirScape Bathroom Ventilation Kit Installation Manual, 06102015
©AirScape, Inc., 2015. All Rights Reserved.
Page 5
Phone:866.448.8187(8:00am–5:00pmPST,M–F)
AirScape,Inc.
625CharlesWay
Medford,OR97501
CONTACT INFORMATION
Problem: Fan will not turn on.
Makesurepoweristurnedonatthebreaker.Checkwiringtofanandtimerswitch.Checkfantoensure
impellercanspinfreely.
Problem: Fan is noisy.
Determinelocationofnoisesource.Checkductforkinks.Checkductconnectionstoensureinnercoilis
notcollapsed.Iffanvibrationisthenoisesource,tryusingrubberizedwashersorgaskettodampenthe
noise,orhangthefanusingmetalstrappingandvibrationabsorbingmaterial.
Problem:Fanruns,butthereislittletonoairow.
Checkductforkinks.Checkbackdraftdamperdirection.Checkductconnectionstoensureinnercoilis
notcollapsed.Checkthatthefanimpellerisspinningfreely.
TROUBLESHOOTING
Plenum Box &
Backdraft Damper
Dimensions
WARRANTY
AirScape Bathroom Ventilation Kit Installation Manual, 06102015
©AirScape, Inc., 2015. All Rights Reserved.
Page 6
Hardware
AirScapewarrantstheoriginalenduser(“Customer”)thatnewAirScapefanproducts,includingallmoving
parts,motors,dampers,anddamperactuatorswillbefreefromdefectsinworkmanshipandmaterials,
undernormaluse,forthree(3)yearsfromtheoriginalpurchasedate.Electronictimersareexcludedand
arewarrantedbythemanufacturer.
Software
AirScapewarrantstoCustomerthattheAirScapefansoftwarewillperforminsubstantialconformanceto
itsprogramspecicationsforaperiodofthree(3)yearsfromthedateoftheoriginalpurchase.
Exclusions
Thiswarrantyexcludes(1)physicaldamagetothesurfaceoftheproduct,includingcracksorscratcheson
theoutsidecasing;(2)damagecausedbymisuse,neglect,improperinstallation,unauthorizedattempts
toopen,repair,ormodifytheproduct,oranyothercausebeyondtherangeofintendeduse;(3)damage,
causedbyaccident,re,powerchanges,otherhazard,oractsofGod;or(4)useoftheproductwithany
unauthorizeddeviceifsuchdevicecausestheproblem.
Exclusive Remedies
ShouldacovereddefectoccurduringthewarrantyperiodandCustomernotiesAirScape,Customer’s
soleandexclusiveremedywillbe,atAirScape’ssoleoptionandexpense,torepairorreplacetheproduct.
Replacementproductsorpartsmaybeneworreconditionedoracomparableversionofthedefective
item.AirScapewarrantsanyreplacedproductorpartforaperiodofninety(90)daysfromshipment,or
throughtheendoftheoriginalwarranty,whicheverislonger.
Obtaining Warranty Service
CustomermustcontactandreturnproducttoAirScape,ProductdealerorInstallerwithintheapplicable
warrantyperiodtoobtainwarrantyservice.Datedproofoforiginalpurchasewillberequired.AirScapewill
notberesponsibleforCustomer’smemorydatacontainedin,storedon,orintegratedwithanyproducts
returnedtoAirScapeforrepair,whetherunderwarrantyornot.
Warranty Exclusive
Theforgoingwarrantiesandremediesareexclusiveandinlieuofallotherwarranties,expressorimplied,
includingwarrantiesofmerchantability,tnessforaparticularpurpose,correspondencewithdescription,
andnon-infringement,allofwhichareexpresslydisclaimedbyAirScapeanditssuppliers.
Disclaimer
NeitherAirScapenoritssuppliersshallbeliableforincidental,consequential,indirect,special,orpunitive
damagesofanykind,ornanciallossarisingoutoforinconnectionwiththesaleoruseofthisproduct,
whetherbasedincontract,tort(includingnegligence)oranyothertheory,evenifAirScapehasbeenad-
visedofthepossibilityofsuchdamagesAirScape’sentireliabilityshallbelimitedtoreplacementorrepair
oftheproduct.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6

AirScape CVK-105 Operating instructions

Type
Operating instructions
This manual is also suitable for

AirScape CVK-105 is a bathroom ventilation kit designed to exhaust air from your bathroom quickly, quietly, and efficiently, keeping the space fresh and serene. This unit is ideal for general ventilation and can be used in a variety of applications, including bathrooms, laundry rooms, and other small spaces. The CVK-105 features a powerful fan that can move up to 105 cubic feet of air per minute (CFM), making it ideal for even the largest bathrooms. The fan is also very quiet, operating at just 0.3 sones on the low setting and 1.0 sones on the high setting.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI