Laufen 9505534 Technical Guide

Type
Technical Guide
KARTELL SHOWER/BATH MIXER
To see the complete LAUFEN range go to
www.reece.com.au/bathrooms
LAUFEN
Disclaimer: Products in this specification manual must by regulation be installed by licensed and registered
trade people. The manufacturer/distributor reserves the right to vary specifications or delete models from
their range without prior notification. Dimensions are nominal measurements only. Dimensions and set-outs
listed are correct at time of publication however the manufacturer/distributor takes no responsibility for
printing errors.
Tech Page Version 1
CLEANING RECOMMENDATIONS
We recommend the use of soapy water or approved cleaners.
This product should not be cleaned with abrasive materials.
Damage caused by any improper treatment is not covered by the product warranty. Refer to Warranty Conditions.
Dimensions are nominal measurements only.
TM
WMK25894
AS/NZS 3718
SPECIFICATIONS
Recommended use Domestic, Hotel and Commercial
Colour availability Chrome
Pressure rating Maximum continuous operating pressure 1000kPa.
As per AS/NZS3500 pressure must be limited to
500kPa on any new home, extension or renovation.
For best performance and longer life we recommend
150-500kPa.
Hot and cold water inlet pressure should be equal.
Temperature rating Maximum continuous working temperature 80°C
Suitable Hot Water
Units
Storage Tank: Yes
Continuous Flow: Yes
Gravity Feed: Not suitable
page 1 of 4
LAUFEN
Plumbers, please ensure a copy of the installation
instructions is left with the end user for future reference
Important Note
Mixer must be installed to the requirements of AS/NZS 3500 by a qualified plumber. Your mixer comes to you already factory
assembled and tested. We do not recommend the dismantling of any internal part of the mixer. The mixers are factory tested and
sealed so as to give the best performance.
KARTELL SHOWER/BATH MIXER
INSTALLATION INSTRUCTIONS
1
2
3
4
5
Turn off the stop-cocks before working on
the elements
Factory setting
Input/Output inverters
page 2 of 4
LAUFEN
Plumbers, please ensure a copy of the installation
instructions is left with the end user for future reference
KARTELL SHOWER/BATH MIXER
2
3
6 Nm
+/- 1 Nm
Tighten the 2 screws parallel (1 turn each side)
Check before installation that all seals are available and at the right place
page 3 of 4
LAUFEN
Plumbers, please ensure a copy of the installation
instructions is left with the end user for future reference
KARTELL SHOWER/BATH MIXER
Before installing the decor, open the valves and check for
water tightness
Only for Simibox Light without stop valves
1
3
2
4
5
Examples of how to fit the decorative elements
page 4 of 4
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

Laufen 9505534 Technical Guide

Type
Technical Guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI