Aruba FlexFabric 5945 Switch Series Installation guide

Category
Network switches
Type
Installation guide

This manual is also suitable for

HPE FlexFabric 5945 Switch Series
Installation Guide
P
art number: 5200-5401f
Document version: 6W109-20230310
© Copyright 2019, 2023 Hewlett Packard Enterprise Development LP
The information contained herein is subject to change without notice. The only warranties for Hewlett Packard
Enterprise products and services are set forth in the express warranty statements accompanying such
products and services. Nothing herein should be construed as constituting an additional warranty. Hewlett
Packard Enterprise shall not be liable for technical or editorial errors or omissions contained herein.
Confidential computer software. Valid license from Hewlett Packard Enterprise required for possession, use, or
copying. Consistent with FAR 12.211 and 12.212, Commercial Computer Software, Computer Software
Documentation, and Technical Data for Commercial Items are licensed to the U.S. Government under vendor’s
standard commercial license.
Links to third-party websites take you outside the Hewlett Packard Enterprise website. Hewlett Packard
Enterprise has no control over and is not responsible for information outside the Hewlett Packard Enterprise
website.
Acknowledgments
Intel®, Itanium®, Pentium®, Intel Inside®, and the Intel Inside logo are trademarks of Intel Corporation in the
United States and other countries.
Microsoft® and Windows® are trademarks of the Microsoft group of companies.
Adobe® and Acrobat® are trademarks of Adobe Systems Incorporated.
Java and Oracle are registered trademarks of Oracle and/or its affiliates.
UNIX® is a registered trademark of The Open Group.
i
Contents
Preparing for installation ················································································ 1
Safety recommendations ··································································································································· 1
Examining the installation site ···························································································································· 2
Temperature/humidity ································································································································ 2
Cleanliness ················································································································································· 2
Corrosive gas limit ······································································································································ 3
EMI ····························································································································································· 4
Laser safety ················································································································································ 4
Installation tools ················································································································································· 4
Installation accessories ······································································································································ 4
Installing the switch ························································································ 7
Installing the switch in a 19-inch rack················································································································· 8
Rack-mounting procedures at a glance ····································································································· 8
Rack-mounting requirements ····················································································································· 8
Installation accessories ···························································································································· 12
Mounting brackets, chassis rails, and grounding cable installation positions ·········································· 14
Attaching the mounting brackets and chassis rails to the chassis ··························································· 16
Connecting the grounding cable to the chassis ······················································································· 21
Attaching the slide rails to the rack ·········································································································· 22
Mounting the switch in the rack ················································································································ 23
Grounding the switch ······································································································································· 28
Installing/removing fan trays ···························································································································· 29
Installing a fan tray ··································································································································· 29
Removing a fan tray ································································································································· 30
Installing/removing power supplies ·················································································································· 31
Installing a power supply ·························································································································· 31
Removing a power supply ························································································································ 32
Connecting the power cords ···························································································································· 34
Connecting an AC power cord ················································································································· 34
Connecting a DC power cord ··················································································································· 35
Installing/removing expansion cards ················································································································ 36
Installing an expansion card····················································································································· 36
Removing an expansion card ··················································································································· 38
Verifying the installation ··································································································································· 38
Accessing the switch for the first time ·························································· 39
Connecting the switch to a configuration terminal···························································································· 39
Connecting the console cable ·························································································································· 40
Connecting the mini USB console cable ·········································································································· 41
Setting terminal parameters ····························································································································· 42
Powering on the switch ···································································································································· 43
Setting up an IRF fabric ··············································································· 44
IRF fabric setup flowchart ································································································································ 44
Planning IRF fabric setup ································································································································· 45
Planning IRF fabric size and the installation site ······················································································ 45
Identifying the master switch and planning IRF member IDs ··································································· 45
Planning IRF topology and connections··································································································· 46
Identifying physical IRF ports on the member switches ··········································································· 47
Planning the cabling scheme ··················································································································· 48
Configuring basic IRF settings ························································································································· 49
Connecting the physical IRF ports ··················································································································· 49
Accessing the IRF fabric to verify the configuration ························································································· 49
Maintenance and troubleshooting ································································ 51
Power supply failure ········································································································································· 51
ii
Symptom ·················································································································································· 51
Solution ···················································································································································· 51
Fan tray failure ················································································································································· 51
Symptom ·················································································································································· 51
Solution ···················································································································································· 52
Configuration terminal display problems ·········································································································· 52
No display ················································································································································ 52
Garbled display ········································································································································ 52
Appendix A Chassis views and technical specifications ······························· 53
Chassis views ·················································································································································· 53
HPE 5945 48SFP28 8QSFP28 ················································································································ 53
HPE 5945 2-slot ······································································································································· 54
HPE 5945 4-slot ······································································································································· 55
HPE 5945 32QSFP28 ······························································································································ 57
Technical specifications ··································································································································· 58
Appendix B FRUs ························································································ 62
Power supplies ················································································································································· 63
Fan trays ·························································································································································· 64
Expansion cards··············································································································································· 64
Appendix C Ports and LEDs ········································································ 67
Ports ································································································································································· 67
Console port ············································································································································· 67
Management Ethernet port ······················································································································ 67
FE SFP modules ······································································································································ 68
USB port ··················································································································································· 68
SFP port ··················································································································································· 68
QSFP28 port ············································································································································ 69
QSFP+ port ·············································································································································· 73
SFP28 port ··············································································································································· 73
SFP+ port ················································································································································· 76
FC port ····················································································································································· 77
LEDs ································································································································································ 77
System status LED ··································································································································· 77
NOTE: ········································································································· 77
QSFP28 port LED ···································································································································· 78
QSFP+ port LED ······································································································································ 78
SFP28 port LED ······································································································································· 78
SFP+ port LED ········································································································································· 78
SFP port LED ··········································································································································· 79
Management Ethernet port LEDs············································································································· 79
Fan tray alarm LEDs ································································································································ 80
Appendix D Cooling system ········································································· 80
Document conventions and icons ································································ 82
Conventions ····················································································································································· 82
Network topology icons ···································································································································· 83
Support and other resources ······································································· 84
Accessing Hewlett Packard Enterprise Support······························································································· 84
Accessing updates ··········································································································································· 84
Websites ·················································································································································· 85
Customer self repair ································································································································· 85
Remote support ········································································································································ 85
Documentation feedback ························································································································· 85
Index ············································································································ 87
1
Preparing for installation
Table 1 describes the HPE FlexFabric 5945 Switch Series models, and power supplies and fan trays
available for the switch series.
Table 1 HPE FlexFabric 5945 Switch Series models and power supplies
Product code HPE description Alias
HPE FlexFabric 5945 Switch Series
JQ074A HPE FlexFabric 5945 48SFP28 8QSFP28
Switch HPE 5945 48SFP28 8QSFP28
JQ075A HPE FlexFabric 5945 2-slot Switch HPE 5945 2-slot
JQ076A HPE FlexFabric 5945 4-slot Switch HPE 5945 4-slot
JQ077A HPE FlexFabric 5945 32QSFP28 Switch HPE 5945 32QSFP28
Power supplies
JC680A HPE A58x0AF 650W AC Power Supply 650W AC power supply
JH336A HPE FlexFabric Switch 650W 48V Hot Plug
NEBS-compliant DC Power Supply 650W DC power supply
Fan Tray
JH389A HPE X712 Bck(pwr)-Frt(prt) HV2 Fan Tray X712 Bck(pwr)-Frt(prt) HV2 fan
tray
JH388A HPE X711 Frt(prt)-Bck(pwr) HV2 Fan Tray X711 Frt(prt)-Bck(pwr) HV2 fan
tray
JH185A HPE 5930 4-slot B(pwr) F(prt) Fan Tray 5930 4-slot B(pwr) F(prt) Fan Tray
JH186A HPE 5930 4-slot F(prt) B(pwr) Fan Tray 5930 4-slot F(prt) B(pwr) Fan Tray
For regulatory identification purposes, the HPE 5945 switches are assigned Regulatory Model
Number (RMN). The Regulatory Model Number for these products is listed below.
Product code RMN Description
JQ074A BJNGA-AD0075 HPE FlexFabric 5945 48SFP28 8QSFP28 Switch
JQ075A BJNGA-AD0076 HPE FlexFabric 5945 2-slot Switch
JQ076A BJNGA-AD0077 HPE FlexFabric 5945 4-slot Switch
JQ077A BJNGA-AD0078 HPE FlexFabric 5945 32QSFP28 Switch
Safety recommendations
To avoid any equipment damage or bodily injury caused by incorrect use, read the following safety
recommendations before installation. Note that the recommendations do not cover every possible
hazardous condition.
•
Before cleaning the switch, remove all power cords from the switch. Do not clean the switch
with wet cloth or liquid.
2
•
Do not place the switch near water or in a damp environment. Prevent water or moisture from
entering the switch chassis.
•
Do not place the switch on an unstable case or desk. The switch might be severely damaged in
case of a fall.
•
Ensure good ventilation of the equipment room and keep the air inlet and outlet vents of the
switch free of obstruction.
•
Connect the yellow-green protection grounding cable before power-on.
•
Make sure the operating voltage is in the required range.
•
To avoid electrical shocks, do not open the chassis while the switch is operating or when the
switch is just powered off.
•
When replacing field replaceable units (FRUs), including power supplies and fan trays, wear an
ESD wrist strap to avoid damaging the units.
Examining the installation site
The switch must be used indoors.
Mount your switch in a rack and verify the following items:
•
Adequate clearance is reserved at the air inlet and outlet vents for ventilation.
•
The rack has a good ventilation system.
•
Identify the hot aisle and cold aisle at the installation site, and make sure ambient air flows into
the switch from the cold aisle and exhausts to the hot aisle.
•
Identify the airflow designs of neighboring devices, and prevent hot air flowing out of the
neighboring devices from entering the top device.
•
The rack is sturdy enough to support the switch and its accessories.
•
The rack is reliably grounded.
To ensure correct operation and long service life of your switch, install it in an environment that meets
the requirements described in the following subsections.
Temperature/humidity
Maintain appropriate temperature and humidity in the equipment room.
•
Lasting high relative humidity can cause poor insulation, electricity leakage, mechanical
property change of materials, and metal corrosion.
•
Lasting low relative humidity can cause washer contraction and ESD and cause problems
including loose mounting screws and circuit failure.
•
High temperature can accelerate the aging of insulation materials and significantly lower the
reliability and lifespan of the switch.
For the temperature and humidity requirements for the switch, see "Technical specifications."
Cleanliness
Dust buildup on the chassis might cause electrostatic adsorption and dust corrosion, resulting in
poor contact of metal connectors and contact points. This might shorten the device's lifetime and
even cause device failure in the worst case. Table 2 describes the switch requirement for
cleanliness.
3
Table 2 Switch requirement for cleanliness
Substance Particle diameter Concentration limit
Dust particles ≥ 0.5 µm ≤ 1.8 × 107 particles/m3
To maintain cleanliness in the equipment room, follow these guidelines:
•
Keep the equipment room away from pollution sources. Do not smoke, eat, or drink in the
equipment room.
•
Use double-layer glass in windows and seal doors and windows with dust-proof rubber strips.
Use screen doors and window screens for doors and windows open to the outside and make
sure the external windows are air tight.
•
Use dustproof materials for floors, walls, and ceilings and use wallpaper or matt paint that does
not produce powders.
•
Clean the equipment room regularly and clean the air filters of the rack each month.
•
Wear ESD clothing and shoe covers before entering the equipment room, keep the ESD
clothing and shoe covers clean, and change them frequently.
Corrosive gas limit
Corrosive gases can accelerate corrosion and aging of metal components. Make sure the corrosive
gases do not exceed the concentration limits as shown in Table 3.
Table 3 Corrosive gas concentration limits
Gas Average concentration (mg/m3) Maximum concentration (mg/m3)
SO2 0.3 1.0
H2S 0.1 0.5
Cl2 0.1 0.3
HCI 0.1 0.5
HF 0.01 0.03
NH3 1.0 3.0
O3 0.05 0.1
NOX 0.5 1.0
CAUTION:
As a best practice, control the
corrosive gas concentrations in the equipment room at their
average
values
. Make sure the corrosive gas concentrations do not exceed 30 minutes per day at their
maximum values.
To control corrosive gases, use the following guidelines:
•
As a best practice, do not build the equipment room in a place with a high concentration of
corrosive gases.
•
Make sure the equipment room is not connected to sewer, vertical shaft, or septic tank pipelines
and keep it far away from these pipelines. The air inlet of the equipment room must be away
from such pollution sources.
•
Use environmentally friendly materials to decorate the equipment room. Avoid using organic
materials that contains harmful gases, such as sulfur or chlorine-containing insulation cottons,
rubber mats, sound-proof cottons, and avoid using plasterboards with high sulfur concentration.
4
•
Place fuel (diesel or gasoline) engines separately. Do not place them in the same equipment
room with the device. Make sure the exhausted air of the engines will not flow into the
equipment room or towards the air inlet of the air conditioners.
•
Place batteries separately. Do not place them in the same room with the device.
•
Employ a professional company to monitor and control corrosive gases in the equipment room
regularly.
EMI
All electromagnetic interference (EMI) sources, from outside or inside of the switch and application
system, adversely affect the switch in the following ways:
•
A conduction pattern of capacitance coupling.
•
Inductance coupling.
•
Electromagnetic wave radiation.
•
Common impedance (including the grounding system) coupling.
To prevent EMI, use the following guidelines:
•
If AC power is used, use a single-phase three-wire power receptacle with protection earth (PE)
to filter interference from the power grid.
•
Keep the switch far away from radio transmitting stations, radar stations, and high-frequency
devices.
•
Use electromagnetic shielding, for example, shielded interface cables, when necessary.
•
To prevent signal ports from getting damaged by overvoltage or overcurrent caused by lightning
strikes, route interface cables only indoors.
Laser safety
WARNING
!
•
The switch is a Class 1M laser device.
•
Disconnected optical fibers or transceiver modules might emit invisible laser light. Do not stare
into beams or view directly with optical instruments when the switch is operating.
Installation tools
No installation tools are provided with the switch. Prepare the following tools yourself:
•
Phillips screwdriver.
•
ESD wrist strap.
•
Marker.
Installation accessories
Table 4 Installation accessories
Product code Description Quantity Applicable models
5066-0850 1U mounting bracket kit (including one
pair of mounting brackets and eight M4
countersunk screws) 1 kit HPE 5945 32QSFP28
5
Product code Description Quantity Applicable models
5190-0719
1U mounting bracket kit (including one
pair of mounting brackets and eight M4
countersunk screws)
1 kit
• HPE 5945 48SFP28
8QSFP28
• HPE 5945 2-slot
5190-0720
2U mounting bracket kit (including one
pair of mounting brackets and eight M4
countersunk screws)
1 kit HPE 5945 4-slot
5185-8713
1U long slide rail kit (including one pair
of slide rails, one pair of guide rails, and
four M4 countersunk screws)
1 kit
• HPE 5945 48SFP28
8QSFP28
• HPE 5945 32QSFP28
5185-8681
1U short slide rail kit (including one pair
of slide rails and four M4 countersunk
screws)
1 kit • HPE 5950 32QSFP28
• HPE 5945 2-slot
5185-8684
2U short slide rail kit (including one pair
of slide rails and four M4 countersunk
screws)
1 kit HPE 5945 4-slot
N/A M6 screw and floating nut
User
supplied All HPE 5945 switches
5184-6723 Grounding cable 1 All HPE 5945 switches
6
Product code Description Quantity Applicable models
5185-9579 Grounding screw
2 All HPE 5945 switches
5190-1773
Power supply filler module
1 All HPE 5945 switches
5003-2403
Interface module filler module
1 • HPE 5945 4-slot
• HPE 5945 2-slot
5185-8688
5400-0249
DC power cord
The power cord color code scheme is
for illustration only. The cable delivered
for your country or region might use a
different color scheme.
1 650W DC power supply
5185-8748 Removable cable tie
1 All power supplies
5185-8627
Console cable
Optional All HPE 5945 switches
N/A
Mini USB console cable
User
supplied All HPE 5945 switches
5185-8722
SFP/SFP+/SFP28 dust plug
Optional All HPE 5945 switches
5187-9022
QSFP28 dust plug
Optional All HPE 5945 switches
7
Installing the switch
CAUTION:
Keep the tamper
-
proof seal on a mounting screw on the chassis cover intact, and if you want to open
the chassis, contact
Hewlett Packard Enterprise for permission. Otherwise, Hewlett Packard
Enterprise shall not be liable for any consequence caused thereby.
Figure 1 Hardware installation flow
Start
Install the switch
Ground the switch
Connect power cords
Verify the installation
Turn on the circuit
breakers
Operating correctly? Turn off the circuit
breakers
Troubleshoot the
switch
Install expansion
cards?
Yes
Yes
No
No
Install expansion cards
Operating correctly?
Yes
No
Resolve the
problem
End
Install power modules
Install fan trays
8
Installing the switch in a 19-inch rack
Rack-mounting procedures at a glance
Figure 2 Rack-mounting procedure
NOTE:
If a rack shelf is available, you can put the switch on the rack shelf
and slide the switch to a
position
so that the mounting brackets make close contact with the front rack posts. Then use screws to
secure the mounting brackets to the rack.
Rack-mounting requirements
Figure 3 HPE 5945 48SFP28 8QSFP28 chassis width (mounting brackets installed at the port
side)
(1) Power supply handle (2) Mounting bracket
Figure 4 HPE 5945 48SFP28 8QSFP28 chassis width (mounting brackets installed at the
power supply side)
(2) Mounting bracket
Determine the installation
position (near the power
module side or port side )
for the mounting brackets
Attach the chassis
rails to both sides
of the switch
Connect the
grounding cable to
a grounding point
Attach the mounting
brackets to both
sides of the switch
Attach the slide
rails to the rack Install the switch
in the rack
26 mm (1.02 in)
460 mm
(18.11 in)
43.6 mm
(1.72 in)
12
43.6 mm
(1.72 in)
460 mm
(18.11 in)
26 mm
(1.02 in)
12
9
Figure 5 HPE 5945 2-slot chassis width (mounting brackets installed at the port side)
(2) Mounting bracket
Figure 6 HPE 5945 2-slot chassis width (mounting brackets installed at the power supply
side)
(1) Power supply handle (2) Mounting bracket
Figure 7 HPE 5945 4-slot chassis width (mounting brackets installed at the port side)
(2) Mounting bracket
1
26 mm
(1.02 in)
660 mm
(25.98 in)
2
44.2 mm
(1.74 in)
44.2 mm
(1.74 in)
1
26 mm
(1.02 in)
660 mm
(25.98 in)
2
88.1 mm
(3.47 in)
1
90 mm
(3.54 in)
26 mm
(1.02 in)
660 mm
(25.98 in)
3
2
10
Figure 8 HPE 5945 4-slot chassis width (mounting brackets installed at the power supply
side)
(2) Power supply handle
Figure 9 HPE 5945 32QSFP28 chassis width (mounting brackets installed at the port side)
(2) Mounting bracket
Figure 10 HPE 5945 32QSFP28 chassis width (mounting brackets installed at the power
supply side)
(2) Mounting bracket
88.1 mm
(3.47 in)
26 mm
(1.02 in)
660 mm
(25.98 in)
90 mm
(3.54 in)
2
1
3
43.6 mm
(1.72 in)
1
26 mm
(1.02 in)
460 mm
(18.11 in)
2
1
26 mm
(1.02 in)
460 mm
(18.11 in)
2
11
Table 5 Distance requirements between the front and rear rack posts
Switch
model Installation
method Chassis dimensions
Distance
between the
front and rear
rack posts
Rack
requirements
HPE 5945
48SFP28
8QSFP28
Mounting brackets
at the port side or
power supply side
• Height—43.6 mm
(1.72 in)/1 RU
• Width—440 mm
(17.32 in)
• Depth—486 mm
(19.13 in)
ï‚¡ 460 mm (18.11
in) for the
chassis
ï‚¡ 26 mm (1.02 in)
for the power
supply/fan tray
handles
692 to 853 mm
(27.24 to 33.58
in)
• A minimum of
800 mm (31.50
in) in depth
(recommended)
• A minimum of
130 mm (5.12 in)
between the front
rack post and the
front door.
• A minimum of
550 mm (21.65
in) between the
front rack post
and the rear
door.
HPE 5945
2-slot
Mounting brackets
at the port side or
power supply side
• Height—44.2 mm
(1.74 in)/1 RU
• Width—440 mm
(17.32 in)
• Depth—686 mm
(27.01 in)
ï‚¡ 660 mm (25.98
in) for the
chassis
ï‚¡ 26 mm (1.02 in)
for the power
supply/fan tray
handles
519 to 768 mm
(20.43 to 30.24
in)
• A minimum of
1000 mm (39.37
in) in depth
(recommended)
• A minimum of
130 mm (5.12 in)
between the front
rack post and the
front door.
• A minimum of
750 mm (29.53
in) between the
front rack post
and the rear
door.
HPE 5945
4-slot
Mounting brackets at
the port side
• Height—88.1 mm
(3.47 in)/2 RU
• Width—440 mm
(17.32 in)
• Depth—776 mm
(33.55 in)
ï‚¡ 660 mm (25.98
in) for the
chassis
ï‚¡ 26 mm (1.02 in)
for the power
supply/fan tray
handles
ï‚¡ 90 mm (3.54) for
the mounting
brackets
518 to 923 mm
(20.39 to 36.34
in)
• A minimum of
1000 mm (39.37
in) in depth
(recommended)
• A minimum of
130 mm (5.12 in)
between the front
rack post and the
front door.
• A minimum of
750 mm (29.53
in) between the
front rack post
and the rear
door.
Mounting brackets at
the power supply
side
• Height—88.1 mm
(3.47 in)/2 RU
• Width—440 mm
(17.32 in)
• Depth—750 mm
(29.53 in)
ï‚¡
660 mm (25.98
518 to 858 mm
(20.39 to 33.78
in)
12
Switch
model Installation
method Chassis dimensions
Distance
between the
front and rear
rack posts
Rack
requirements
in) for the
chassis
ï‚¡ 90 mm (3.54) for
the mounting
brackets
HPE 5945
32QSFP2
8
Mounting brackets
and long slide rails
(provided)
• Height—43.6 mm
(1.72 in)/1 RU
• Width—440 mm
(17.32 in)
• Depth—486 mm
(19.13 in)
ï‚¡ 460 mm (18.11
in) for the
chassis
ï‚¡ 26 mm (1.02 in)
for the power
supply/fan tray
handles
621 to 853 mm
(33.58 to 24.45
in)
• A minimum of
1000 mm (39.37
in) in depth
(recommended)
• A minimum of
130 mm (5.12 in)
between the front
rack post and the
front door.
• A minimum of
550 mm (21.65
in) between the
front rack post
and the rear
door.
Mounting brackets
and short slide rails
(provided)
401 to 633 mm
(24.92 to 15.79
in)
Installation accessories
Table 6 Installation accessories
Switch model Mounting brackets
(provided) Cable management
brackets Rack mounting rail
kit
HPE 5945 48SFP28
8QSFP28
1U high, one pair. See
Figure 11.
The mounting bracket
with a round hole in the
narrow flange supports
hanging a fixed asset
tag.
N/A 1U high, including one
pair of long slide rails
and one pair of chassis
rails. See Figure 14.
HPE 5945 2-slot
1U high, one pair. See
Figure 11.
The mounting bracket
with a round hole in the
narrow flange supports
hanging a fixed asset
tag.
N/A
1U high, including one
pair of short slide rails
and one pair of chassis
rails (provided). See
Figure 15.
HPE 5945 4-slot 2U high, one pair. See
Figure 12. One pair (provided). See
Figure 12.
2U high, including one
pair of slide rails and one
pair of chassis rails
(provided). See Figure
16.
HPE 5945 32QSFP28
1U high, one pair. See
Figure 13.
The mounting bracket
with a round hole in the
N/A
1U high, including one
pair of long slide rails
and one pair of chassis
rails (provided). See
Figure 14.
13
Switch model Mounting brackets
(provided) Cable management
brackets Rack mounting rail
kit
narrow flange supports
hanging a fixed asset
tag.
1U high, including one
pair of short slide rails
and one pair of chassis
rails (optional). See
Figure 15.
Figure 11 Mounting brackets provided with the HPE 5945 48SFP28 8QSFP28 and HPE 5945
2-slot switches
Figure 12 Mounting brackets provided with the HPE 5945 4-slot switch
(1) Cable management bracket
(2) Mounting bracket
Figure 13 Mounting brackets provided with the HPE 5945 32QSFP28 switch
1 2
14
Figure 14 1U long slide rail and chassis rail
(1) Chassis rail
(2) Long slide rail
Figure 15 1U short slide rail and chassis rail
Figure 16 2U slide rail and chassis rail
(1) Chassis rail
(2) Slide rail
Mounting brackets, chassis rails, and grounding cable
installation positions
The switch has one mounting position near the network ports and one mounting position near the
power supplies for mounting brackets.
The HPE 5945 48SFP28 8QSFP28 switch provides two grounding points: primary grounding point
(with a grounding sign) and auxiliary grounding point, as shown in Figure 17.
The HPE 5945 2-slot switch provides two grounding points: primary grounding point (with a
grounding sign) and auxiliary grounding point, as shown in Figure 18.
The HPE 5945 4-slot switch provides three grounding points: primary grounding point (with a
grounding sign), auxiliary grounding point 1, and auxiliary grounding point 2, as shown in Figure 19.
12
1 2
15
The HPE 5945 32QSFP28 switch provides two grounding points: primary grounding point (with a
grounding sign) and auxiliary grounding point, as shown in Figure 20.
Select installation positions for the mounting brackets, chassis rails, and grounding cable as
required.
Figure 17 Mounting brackets and grounding cable installation positions on the HPE 5945
48SFP28 8QSFP28 switch
(1) Power supply-side mounting position
(2) Primary grounding point
(3) Auxiliary grounding point
(4) Port-side mounting position
Figure 18 Mounting brackets and grounding cable installation positions on the HPE 5945
2-slot switch
(1) Power supply-side mounting position
(2) Primary grounding point
(3) Auxiliary grounding point
(4) Port-side mounting position
1234
1234
16
Figure 19 Mounting brackets and grounding cable installation positions on the HPE 5945
4-slot switch
(1) Auxiliary grounding point 2
(2) Power supply-side mounting position
(3) Primary grounding point
(4) Port-side mounting position
(5) Auxiliary grounding point 1
Figure 20 Mounting brackets and grounding cable installation positions on the HPE 5945
32QSFP28 switch
(1) Power supply-side mounting position
(2) Primary grounding point
(3) Auxiliary grounding point
(4) Port-side mounting position
Attaching the mounting brackets and chassis rails to the
chassis
1. Place the wide flange of the mounting bracket against the chassis side panel. Align the
mounting bracket installation holes with the appropriate screw holes in the chassis. Use M4
123
4
1
5
1234
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92

Aruba FlexFabric 5945 Switch Series Installation guide