American Standard 6067.721.002 User manual

Category
Sanitary ware
Type
User manual
L201
© 2012 AS America Inc.
4/12
SELECTRONIC
FloWise
®
EXPOSED
1.28/1.1 GPF DUAL FLUSH TOILET FLUSH VALVE
HARDWIRED AC POWERED, SENSOR OPERATED
MODEL NUMBER:
6067.721.002 HARD-WIRED AC POWERED:
Includes UL-approved Hard-Wired AC transformer
(electrical box by others). 11-1/2" rough-in
6068.721.002 MULTI-AC POWERED:
Includes 10' extension cable. One transformer (sold
separately) can operate up to 15 faucets and/or
ush valves. 11-1/2" rough-in
OPERATING PRESSURE:
Overall Range: 20-125 psi**
Recommended: 25 psi (owing)-80 psi (static)
FLOW REQUIREMENT:
25gpm (94.6 L/min.)
** Water pressure over 80 psi is not recommended
for most plumbing xtures.
ACCESSORIES:
• Cast wall anges (1" & 1-1/2")
• Solid ring pipe supports (2-1/2" & 6" C-E)
• Split ring pipe supports (2-1/2" & 6" C-E)
GENERAL DESCRIPTION:
Exposed, Hardwired AC Powered, Sensor Operated
Selectronic™ Water Closet Flush Valve for
oor-mounted or wall-hung 1-1/2" top spud bowls.
Inlet includes 1" I.P.S. angle stop with back-ow
protection, vandal-resistant cap, sweat solder kit,
cover tube and wall ange.
Outlet includes 1-1/2" vacuum breaker, spud coupling
and ange.
PRODUCT FEATURES:
• Light ush (1.1 gpf: 30% water savings) if user is in detec-
tion zone for 60 seconds or less
• Standard ush (1.28 gpf 20% water savings) if user is in
detection zone for more than 60 seconds
• Electronic ush valve with Selectronic™ proximity system
forHands Free” operation
• Includes UL approved hardwired AC transformer
• Input Voltage: 100 - 250 VAC, 50 / 60 Hz. Output Voltage:
6 VDC.
• Self-Cleaning Piston operation with integral wiper spring
prevents clogging and reduces maintenance
• Piston operation delivers superior ush accuracy and
repeatability
• Adjustable tailpiece
• Chemical resistant EPDM seals are unaffected by
chloramines and ammonia
• Valve remains closed and does not need to be reset after
loss of power or water pressure
• Fully Mechanical Manual Override Button can ush toilet
during a power outage
• Vandal-resistant metal cover plate (for 2-gang electric box
supplied by others) with no visible fasteners
• Sensor & electronic controls are fully enclosed and water
resistant
• Range can be adjusted manually or by remote control
• Sanitary Flush - Valve automatically ushes after 24
hours of non-use to clean xture & maintain trap seal
• No external volume adjustment
• 5 second Arming Delay prevents unintentional ushing
• 3-second Flush Delay
• Can be installed left or right-handed
SUPPLY
DN 25mm
(1" I.P.S.)
115mm - 134mm
(4-1/2" - 5-1/4")
FINISHED WALL
FINISHED
FLOOR
57mm (2-1/4")-
137mm (5-3/8")
409mm
(16-1/8")
TYPICAL WATER CLOSET INSTALLATION:
AFWALL™ TOILET SHOWN
293mm
(11-1/2")
-C-L-
SEE ROUGH-IN
ON BACK
CRITICAL
LEVEL
COVER &
ELECTRICAL
BOX
160mm
(6-1/4")
86mm
(3-3/8")
MEETS THE AMERICANS WITH DISABILITIES ACT GUIDELINES
AND ANSI A117.1 REQUIREMENTS FOR ACCESSIBLE AND
USABLE BUILDING FACILITIES-CHECK LOCAL CODES
RECOMMENDED SPECIFICATION:
Electronic proximity infrared sensor activated toilet flush valve shall feature self-cleaning piston valve. Includes a UL listed hardwired power
supply that provides 6 VDC power to run system. Flush volume is determined by amount of time user is in detection zone. 60 seconds or less:
1.1 gpf/4.2 Lpf. More than 60 seconds: 1.28 gpf/4.9 Lpf. Includes a fully mechanical manual over-ride that can provide a complete ush without
power.
Includes cast brass valve body and metal cover with chrome finish and vandal resistant stop cap. Angle stop with back-flow protection
and vacuum breaker included. Flush valve shall be American Standard Model # 606_.721.002.
L202
© 2012 AS America Inc.
4/12
SELECTRONIC
FloWise
®
EXPOSED
1.28/1.1 GPF DUAL FLUSH TOILET FLUSH VALVE
HARDWIRED AC POWERED, SENSOR OPERATED
Roughing-in Dimensions
Right or Left Hand Installation
*Note: The Critical Line (-C-L-) on Vacuum Breaker
must typically be 6
" min. (152mm) above fixture.
Consult Codes for details.
TOP OF
FIXTURE
409mm
(16-1/8)
152mm
(6 MIN.)
293mm
(11-1/2)
-C-L-
-C-L-
116mm
(4-5/8)
86mm
(3-3/8)
72mm
(2-7/8)
DETECTION ZONE
400mm-800mm
(15-3/4 TO 31-1/2)
2-GANG ELECTRICAL
BOX BY OTHERS
SUPPLY
DN 25mm
(1¨ I.P.S.)
15˚
FINISHED WALL
51mm (2") HOLE
FOR CONDUIT
115mm-134mm
(4-1/2 TO 5-1/4)
FOR 1-1/2" TOP
SPUD FIXTURES
MANUAL
OVERRIDE
BUTTON
*CRITICAL
LEVEL
45
˚
180
˚
305mm
(12 MAX.)
160mm
(6-1/4)
160mm
(6-1/4)
57mm (2-1/4) -
137mm (5-3/8)
LISTINGS:
• ASSE 1037
• ANSI/ASME A112.19.2
• ADA Compliant
1 / 1