1.
Introduction .................................................................................................................... 6
General Safety Procedures ........................................................................................... 7
Quick Start Guide .......................................................................................................... 10
Generator Components ............................................................................................... 12
Package Contents ......................................................................................................... 14
Introduction
3.
Checking the Oil ........................................................................................................... 20
Check the Fuel Level .................................................................................................... 21
Starting the Generator ................................................................................................. 22
Starting the Generator - Remote Start ...................................................................... 24
Starting the Generator
2.
Adding Oil ...................................................................................................................... 16
Adding Diesel ................................................................................................................. 17
Grounding the Generator ........................................................................................... 18
Generator Setup
4.
AC Usage ......................................................................................................................... 28
Connecting a Load to the Generator ........................................................................... 30
Voltage Selector Switch ................................................................................................ 31
DC Usage ........................................................................................................................ 32
Using the Generator
3
CONTENTS
4
5.
6.
7.
Maintenance Schedule .................................................................................................. 36
Maintenance Log ........................................................................................................... 37
Checking the Oil ............................................................................................................ 38
Changing the Oil ............................................................................................................. 39
Cleaning the Air cleaner ................................................................................................ 40
Specications .................................................................................................................. 42
.......................................................................................................................... 50
Basic Troubleshooting .................................................................................................. 44
Changing / Inspecting the AVR .................................................................................... 46
Maintenance and Care
Warranty
Troubleshooting
8. .................................................................................................. 54
Contact Information
INTRODUCTION
Notice Regarding Emissions
DuroStar has cemented its reputation as one of the markets leading power equipment companies
who are headquartered in the US. All of our products are manufactured to the strictest guidelines
and go through countless testing in all phases of production.
Evolving our strong engine line, DuroStar has complemented its oerings to include Pressure
Washers, Water Pumps, Engines and now oering V-Twin engines. Reliability is the highest
standard we hold ourselves to, whether its powering a heater during a winter storm that knocks
out power, dewatering a ooded property, or washing away a deck for the summer season
Engines that are certied to comply with U.S. EPA emission regulations for SORE (Small o Road
Equipment), are certied to operate on regular diesel, and may include the following emission
control systems: (EM) Engine Modications and (TWC) Three-Way Catalyst (if so equipped).
6
STOP
Please do not return
to store.
Durostar representatives are ready to help you
with any questions, concerns, or issues about your
new product. We can guide you through assembly,
start up, and how to operate your new generator.
We want you to be able to put your new generator
to use right away!
CALL US BEFORE YOU CONSIDER
RETURNING THE PRODUCT!
1-844-DUROMAX
TOLL FREE
SAFETY ALERT SYMBOL
DANGER: This generator produces poisonous carbon monoxide gas when running. This
gas is both odorless and colorless. Even if you do not see or smell gas, carbon monoxide
may still be present. Breathing this poison can lead to headaches, dizziness, drowsiness,
and eventually death.
Use outdoors ONLY in non-conned areas.
Keep several feet of clearance on all sides to allow proper ventilation of the generator.
WARNING: The exhaust from this product contains chemicals known to the State of
California to cause cancer, birth defects, or other reproductive harm.
WARNING: This generator produces heat when running. Temperatures near exhaust can
exceed 150°F (65°C).
Do not touch hot surfaces. Pay attention to warning labels on the generator denoting
hot parts of the machine.
Allow generator to cool several minutes after use before touching engine or areas
which heat during use.
The safety alert symbol is used with one of the safety words (DANGER,
CAUTION, or WARNING) to alert you of hazards. Please pay attention to
these hazard notices both in this manual and on the generator.
GENERAL SAFETY PROCEDURES
7
Please familiarize yourself with the following safety symbols and words:
DANGER: Indicates a hazard that will result in serious injury or death if instructions are not
followed.
WARNING: Indicates a strong possibility of causing serious injury or death if instructions are not
followed.
CAUTION: Indicates a possibility of personal injury or equipment damage if instructions are not
followed.
WARNING: This generator may emit highly ammable and explosive diesel vapors, which
can cause severe burns or even death. A nearby open ame can lead to an explosion
even if not directly in contact with fuel.
Do not operate near an open ame.
Do not smoke near generator.
Always operate on a rm, level surface.
Always turn generator o before refueling.
Allow generator to cool for at least 2 minutes before removing fuel cap. Loosen cap
slowly to relieve pressure in tank.
Do not overll fuel tank. Fuel may expand during operation. Do not ll to the top of
the tank.
Always check for spilled fuel before operating.
Empty the diesel tank before storing or transporting the generator.
Before transporting, turn fuel valve to the o position and disconnect the spark plug.
WARNING: This generator produces a powerful voltage, which can result in electrocution.
ALWAYS ground the generator before using it (see the “Grounding the Generator”
portion of the “PREPARlNG THE GENERATOR FOR USE section).
Generator should only be plugged into electrical devices, either directly or with an
extension cord. NEVER connect to a building electrical system without a qualied
electrician. Such connections must comply with local electrical laws and codes. Failure
to comply can create a backow of power, which may result in serious injury or death
to utility workers.
Use a ground fault circuit interrupter (GFCI) in highly conductive areas such as metal
decking or steel work. GFCls are available in-line with some extension cords.
Do not use uncovered in rainy or wet conditions.
Do not touch bare wires or receptacles (outlets).
Do not allow children or non-qualied persons to operate.
GENERAL SAFETY PROCEDURES
8
In addition to the above safety notices, please familiarize yourself with the safety and
hazard markings on the generator.
GENERAL SAFETY PROCEDURES
9
QUICK START GUIDE
Add diesel
The fuel cap is located on top of the fuel tank. Fill the tank
with fresh diesel uel. The tank is full when you see fuel in
the bottom of the fuel lter cup. DO NOT overll the tank.
2.
Run/Stop Switch
The Run/Stop Switch is located inside the mainentance
door above the oil ll. Flip the switch to the right to allow
the unit to run.
Add oil
The oil ll cap is located on the lower engine block inside
the maintenance door. Remove the oil ll cap and ll with
15w40 diesel oil.
1.
Turn breaker o
The breaker is located on the right side of the front power
panel. Flip the breaker down to prevent accidental load
when starting the generator.
3.
10
4.
Check power indicator
The power indicator is located to the right of the keyswitch.
Ensure the power indicator is lit before powering
appliances.
8.
Connect devices
Connect your devices to the receptacles on the front panel.
Start with the largest loads rst.
10.
Start generator
The key switch is located on the left side of the front power
panel. Insert the key and turn to the start position to start
the generator. Allow the key to return to the run position
once started.
7.
Turn breaker on
The breaker is located on the right side of the front power
panel. Flip the breaker up to allow power to ow to the
receptacles.
9.
11
GENERATOR COMPONENTS
12
8. Battery 5. Oil Fill
4. Air Filter
3. Lifting Ring
2. Fuel Cap
6. Oil Drain
7. Stop / Run
Switch
1. Muer - Reduces engine emissions and reduces noise
2. Fuel Cap - Allows access to ll the diesel tank.
3. Lifting Ring - Use to lift the generator with a truck crane or winch.
4. Air Filter - a removable element that cleans the air going into the engine.
5. Oil Fill and Dipstick - Use to add or check the engine oil.
6. Oil Drain - Use to remove the engine oil during regular oil changes.
7. Stop/Run Switch - To the right for Connect a ground wire here to properly ground the
generator.
8. Battery - 12V DC 7ah Battery that powers the Electric Start System.
9. Engine Switch – 3 Position Switch to “Start”, “Run”, or turn “O” the generator.
10. Low Oil Alert - Will light if the engine shuts down or will not start due to low oil.
11. Volt Meter - Provides reading of voltage output.
11. Power Indicator - Use to conrm the generator has power output before connecting devices.
1. Muer
14. Circuit Breaker
13. Power Boost
12. Voltmeter
11. Power Indicator
10. Low Oil Alert
12. Volt Meter - Provides reading of voltage output.
13. Power Boost – DuroStar exclusive Power Boost doubles the amperage available in “120v Only”
for heavy loads like RV air conditioners.
14. Circuit Breaker - Resettable switch that protects the generator from electrical overload.
15. 12v DC Charging Posts – DC Output for charging batteries or running small DC powered items.
16. Ground Terminal - Connect a ground wire here to properly ground the generator.
17. 120/240v 4-Prong Twist Lock - Use to connect electrical devices that run 120 or 240 Volt, 60Hz,
single phase, AC current (NEMA L14-30).
18. 120v 3-Prong Twist Lock - Use to connect electrical devices that run 120 Volt, 60 Hz, single
phase, AC current (NEMA 6-20).
19. 120v 3-Prong GFCI Receptacle - Use to connect electrical devices that run 120 Volt, 60 Hz,
single phase, AC current (NEMA 5-20).
13
9. Engine
Switch
19. 120V
3-Prong
Receptacle
18. 120V 3-Prong
Twist Lock
17. 120/240
4-Prong Twist
Lock
16. Ground
Terminal
15. 12V DC
Charging Posts
PACKAGE CONTENTS
Your generator comes with the items listed below. Please check to see that all of the following
items are included with your generator.
Note: Actual tools may dier in appearance or design from image shown.
Double Sided
Screw Driver
Oil Funnel w/ hose
Spanner
DC Charge Cables
Spark Plug Wrench
Plug Ends
Phillips and slot blade
screwdriver used for generator
maintenance.
Used to add oil to the
generator without messy spills.
Assorted wrenches used in
generator maintenance and
assembly. Commonly 8mm,
10mm, 13mm, and 15mm.
Used in conjunction with the
charging posts to charge 12v
automotive style batteries or
small DC appliances.
Used in spark plug
maintenance, inspection, and
installation.
Plug heads for the receptacles
found on the generator are
included to make or rewire
your own cords.
14
GENERATOR SETUP
Proper setup of your generator will get you going as soon as possible while making sure you and
your equipment are safe and cared for.
-20 20 40 60 800 100 F
-30-40 -10 0 10 20 30
-20 40 C
30
10W-30
ENVIRONMENTAL TEMPERATURE
5W-30
SAE
GENERATOR SETUP
Add oil
The generator requires engine oil to operate properly. The generator, when new from the package
contains no oil in the crankcase*. You must add the proper amount of oil before operating the
generator for the rst time. This amount is equal to the oil capacity of the engine crankcase:
WARNING: Do not apply engine oils with additives or 2-stroke engine oils. They don’t have
enough lubrication, and may shorten the engine’s service life.
a. Make sure the generator is on a level surface.
b. Unscrew the oil ller/dipstick cap from the engine .
c. Using a funnel, add the appropriate amount of oil
into the crankcase. You will know the crankcase is
full when the oil level has reached the lower lip of
the opening you have just poured the oil into.
d. Replace oil ller cap.
1.
Step 1 - Adding Oil
Engine oil recommended: SAE 15W-40. Viscosity varies with
regions and temperatures. Choose your oil viscosity using the
chart to the left.
* A small amount of oil from factory testing may be present on
arrival.
Model Number DS7000Q
Engine Oil Capacity 54 . oz (1.6L)
16
WARNING: DO NOT overll the crankcase. This
may damage the motor and shorting overall life
of your generator.
WARNING: Diesel and fuel fumes are highly ammable.
Do not ll tank near an open ame.
Do not overll. Always check for fuel spills.
17
Step 2 - Adding Diesel
Add Diesel
a. Make sure the generator is on a level surface.
b. Unscrew fuel cap and set aside (NOTE: the fuel cap
may be tight and hard to unscrew).
c. Slowly add diesel to the fuel tank. Be careful not
to overll.
d. The fuel gauge on the top of the fuel tank indicates
how much diesel is in the generator fuel tank.
e. Replace fuel cap and wipe up any spilled diesel
with a dry cloth.
NOTE: Fuel can expand. Do not ll the fuel tank
to the very top. Leave a minimum of 1.5 in of open
space.
IMPORTANT:
Never use an oil/diesel mixture. Never use old fuel.
Avoid getting dirt or water in the fuel tank.
Fuel can age in the tank and make it hard to start up
the generator in the future.
Never store generator for extended periods of time
with fuel in the tank.
2.
Model Number DS7000Q
Fuel Tank Capacity 3.8 US Gallons (14.5L)
WARNING: DO NOT overll the crankcase. This
may damage the motor and shorting overall life
of your generator.
GENERATOR SETUP (CONTINUED)
Attach grounding wire
a. Ground the generator by tightening the grounding
nut against a grounding wire.
b. Connect the other end to a copper or brass
grounding rod that’s driven into the earth.
A generally acceptable grounding wire is a No. 12 AWG
(American Wire Gauge) stranded copper wire.
Grounding codes can vary by location. Please contact a local
electrician to check the grounding regulations for your area.
1.
Step 3 - Grounding the Generator
WARNING: Failure to properly ground the generator can result in electrocution.
18
19
STARTING THE GENERATOR
If this is not your rst time using the generator there are still steps you should take to prepare it for
operation each time you use it.
IMPORTANT: At this point you should be familiar with the procedures described in the rst
portion of this section entitled “GENERATOR SETUP” If you have not yet read this section, go
back and read it now.
Step 1 - Check the oil
Check the oil
The generator is equipped with an automatic shuto to
protect it from damage due to low oil. Nonetheless, you
should check the oil level of the engine before each use to
ensure that the engine crankcase has a sucient amount.
To check the oil level:
a. Make sure the generator is on a level surface.
b. Unscrew the oil ller/dipstick cap.
c. With a dry cloth, wipe the oil o of the stick on the
inside of the cap.
d. Insert the dipstick as if you were replacing the
cap and then remove again. There should now be
oil on the stick. If there is no oil on the stick, or oil
only at the very end of the stick, you should add
oil until the engine crankcase is lled (see “Adding
Oil” portion of the “Maintenance” section).
e. Be sure to replace the cap when nished checking
oil.
NOTE: The oil capacity for your generator can be found in
the “Specications” section of this manual.
1.
20
BEFORE YOU START YOUR GENERATOR
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56

DUROMAX DS7000Q Owner's manual

Category
Power generators
Type
Owner's manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI