Hornby R406 Colour Light Signal Owner's manual

Type
Owner's manual
Hornby Hobbies Limited, Westwood, Margate, Kent CT9 4JX
4/309D 0200 Printed in China
Safety Notes
This product is not suitable for children under 3 years because of small parts which can present a chok-
ing hazard. Some components have functional sharp edges – handle with care.
Only use this product with the recommended transformer.
This product must not be connected to more than one power supply.
Before cleaning any part, disconnect the transformer from the mains electricity supply. Do not use liquid
for cleaning.
Retain these details for future reference.
COLOUR LIGHT SIGNAL
To operate an R.406 Colour Light Signal, an R.046
(yellow) On-On Lever Switch is required. The
wiring from a suitable train controller is shown in
Fig.1. The bulbs will function from 12-16 volts DC
or AC.
Two or more Colour Light Signals may be operated
from the same supply source as shown in Fig.2.
Only one wire is needed from the power supply to
the Switches as they are designed to interconnect
automatically when banked together.
Please refer to Safety Notes Overleaf.
ON-ON LEVER SWITCH
As well as operating Colour Light Signals, On-On Lever Switches can be
used for other functions. The Switch (Fig.1) has three sockets for wires,
one in the side (E) and two in the back (C and D). When the lever arm is
in position A, a connection is made between C and E. Switching the lever
to B makes contact between D and E. Two examples are shown of uses
for the On-On Switch.
Alternative Circuits
An On-On Switch acting as an alternative circuit
switch can be used to re-direct the electric circuit
from a train controller to a separate section of a
layout, avoiding the need for an extra power source.
Used in a similar manner it can divert current
supply from an overhead catenary system to
the rails or vice versa.
This is a conguration of track on which a lo-
comotive or train can reverse its direction. It
sometimes occurs in a layout without the builder
realising it is there and in such circumstances can
cause electrical problems.
In its simplest form it appears as shown with cor-
rect wiring and switching arrangements.
A locomotive approaching along the straight arm of
the point must stop in the section between
the two R.618 Isolating Rails. When stopped,
the point setting and the On-On Switch must
be changed and then the locomotive can
continue round the loop with the
setting of the train
controller reversed.
Return Loop
12V or 16V
Black
Red
R.046 (yellow)
On-On Switch
Train
Controller
Brown
16 volt AC
terminals
Green
12 volt DC
for train
Track Clip
(optional)
Black
Red
Brown
16 volt AC
terminals
12 volt DC
terminals
Green
AB
E
D
C
Fig.1
Bridged
Bridged
12 volt DC
R965
R965
BA
AB
BA
R046
R046
BA
R618
R607
R607
R607
R600R600
R601
R618
R612
R600
R607
R607
R607
R607
R606
R046
Fig.1
Fig.2
  • Page 1 1

Hornby R406 Colour Light Signal Owner's manual

Type
Owner's manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI